Testing of Load Capacity of a Foil Thrust Bearing

  • Kim, Choong Hyun;Park, Jisu
    • Tribology and Lubricants
    • /
    • v.34 no.6
    • /
    • pp.300-306
    • /
    • 2018
  • In this study, the performance of foil thrust bearings was investigated by performing bearing take-off and load capacity tests, using an in-house designed and manufactured vertical bearing test rig. The mean take-off rotational speed and maximum load capacity of the bearing specimen were ~18,000 rpm and ~80 kPa, respectively. The vertical bearing test rig was observed to yield higher coefficients of friction and frictional torques than a horizontal bearing test rig under identical test conditions. This was a result of its structural characteristics, in that the bearing specimen is placed atop the thrust runner, which keeps it from being separated from the runner after the bearing take-off. In addition, bearing take-off was observed at a higher runner rotational speed as this structure keeps air from flowing between the top foil and runner surfaces, which requires a higher runner speed. The parallel alignment between the bearing specimen and runner surfaces can be maintained within a certain range more easily in a vertical test rig than in a horizontal test rig. Because of these advantages, Korean Industrial Standard, KS B 2060, recommends a vertical bearing test rig as the standard test device for foil thrust bearings.

Interfacial Reaction on Heat Treatment of Roll-bonded STS304/Al1050/STS439 Clad Materials and its Effect on the Mechanical Properties (압연 제조된 STS439/Al1050/ STS304 Clad소재의 열처리에 따른 계면 반응과 기계적 특성에서의 계면 반응 효과)

  • Song, Jun-Young;Kim, In-Kyu;Lee, Young-Seon;Hong, Sun Ig
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.11
    • /
    • pp.910-915
    • /
    • 2011
  • The microstructures and mechanical properties of roll-bonded STS439/Al1050/STS304 clad materials were investigated after an annealing process at various temperatures. Interfacial layer was developed at the STS439/Al1050 and Al1050/STS304 interfaces at $550^{\circ}C$. STS439/Al1050/STS304 clad metals fractured suddenly in a single step and the fracture decreased with increasing annealing temperatures at $450^{\circ}C$. After annealing at $550^{\circ}C$, samples fractured in three steps with each layer fracturing independently. Interfacial layers formed at $550^{\circ}C$ with a high Vickers microhardness were found to be brittle. During tensile testing, periodic parallel cracks were observed at the interfacial reaction layer. Observed micro-void between Al1050 and the interfacial layer was found to weaken the Al1050/reaction layer interface, leading to the total separation between Al1050 and the reaction layer.

Deep Learning Method for Improving Contamination Dectection of Xoray Inspection System (X-ray 이물검출기의 이물 검출 향상을 위한 딥러닝 방법)

  • Lim, Byung Hey;Jeong, Seung Su;Yu, Yun Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.460-462
    • /
    • 2021
  • Food basically must have nutrition and safety. Recently, a number of symptoms of food poisoning occurred in a kindergarten in Ansan, where food safety was suspected. Therefore, the safety of food is more demanding. In this paper, we propose a method to inprove the detector to secure food safety. The proposed method is to learn through the network of convolution neural network (CNN) and Faster region-CNN (Faster R-CNN) and test the images of normal and foreign products. As a result of testing through a deep learning model, the method that used Faster R-CNN in parallel with the existing foreign body detector algorithm showed better detection rate than other methods.

  • PDF

A Case Study on the Promotion of Instructional Design Competencies Among Preservice Home Economics Teachers in Class Using the Metaverse (예비 가정과교사의 메타버스를 활용한 교수설계 역량 증진을 위한 수업 사례연구)

  • Seong Youn Choi
    • Human Ecology Research
    • /
    • v.62 no.1
    • /
    • pp.81-100
    • /
    • 2024
  • This paper presents a case study in which a lesson was designed and applied to enhance preservice home economics teachers' instructional design competence using the metaverse. For 15 weeks from March 6 to June 14, 14 students enrolled on the course 'Multimedia Home Economics Education' for preservice home economics teachers used the metaverse to engage in problem-based learning to solve instructional design problems in home economics classes. In accordance with the ADDIE design model, in the analysis stage, we assessed preservice home economics teachers' level of knowledge of lessons using the metaverse, and their perceptions of the possibility, necessity, and usefulness of using the metaverse in home economics lessons. In the design and development stage, lesson plans, questions for problem-based learning, assessment tools, and teaching and learning materials were developed. The implementation was conducted in parallel with training on understanding multimedia and the metaverse, and instructional design competence was evaluated through pre- and post-testing and reflection journals. The results revealed that the preservice home economics teachers acquired a good understanding of lessons using the metaverse, learned how to design lessons for self-directed learning by applying the metaverse to their home and classroom, and gained confidence in applying it to their teaching practice or in-service work. It is expected that the results of this study will be used as support materials for prospective and current home economics teachers to design home economics lessons using the metaverse, thereby expanding the horizons of home economics education.

Double-Gauss Optical System Design with Fixed Magnification and Image Surface Independent of Object Distance (물체거리가 변하여도 배율과 상면이 고정되는 이중 가우스 광학계의 설계)

  • Ryu, Jae Myung;Ryu, Chang Ho;Kim, Kang Min;Kim, Byoung Young;Ju, Yun Jae;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2018
  • A change in object distance would generally change the magnification of an optical system. In this paper, we have proposed and designed a double-Gauss optical system with a fixed magnification and image surface regardless of any change in object distance, according to moving the lens groups a little bit to the front and rear of the stop, independently parallel to the direction of the optical axis. By maintaining a constant size of image formation in spite of various object-distance changes in a projection system such as a head-up display (HUD) or head-mounted display (HMD), we can prevent the field of view from changing while focusing in an HUD or HMD. Also, to check precisely the state of the wiring that connects semiconductor chips and IC circuit boards, we can keep the magnification of the optical system constant, even when the object distance changes due to vertical movement along the optical axis of a testing device. Additionally, if we use this double-Gauss optical system as a vision system in the testing process of lots of electronic boards in a manufacturing system, since we can systematically eliminate additional image processing for visual enhancement of image quality, we can dramatically reduce the testing time for a fast test process. Also, the Gaussian bracket method was used to find the moving distance of each group, to achieve the desired specifications and fix magnification and image surface simultaneously. After the initial design, the optimization of the optical system was performed using the Synopsys optical design software.

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.

A Study on Built-In Self Test for Boards with Multiple Scan Paths (다중 주사 경로 회로 기판을 위한 내장된 자체 테스트 기법의 연구)

  • Kim, Hyun-Jin;Shin, Jong-Chul;Yim, Yong-Tae;Kang, Sung-Ho
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.2
    • /
    • pp.14-25
    • /
    • 1999
  • The IEEE standard 1149.1, which was proposed to increase the observability and the controllability in I/O pins, makes it possible the board level testing. In the boundary-scan environments, many shift operations are required due to their serial nature. This increases the test application time and the test application costs. To reduce the test application time, the method based on the parallel opereational multiple scan paths was proposed, but this requires the additional I/O pins and the internal wires. Moreover, it is difficult to make the designs in conformity to the IEEE standard 1149.1 since the standard does not support the parallel operation of data shifts on the scan paths. In this paper, the multiple scan path access algorithm which controls two scan paths simultaneously with one test bus is proposed. Based on the new algorithm, the new algorithm, the new board level BIST architecture which has a relatively small area overhead is developed. The new BIST architecture can reduce the test application time since it can shift the test patterns and the test responses of two scan paths at a time. In addition, it can reduce the costs for the test pattern generation and the test response analysis.

  • PDF

A Study of Parallel Test Among Three ADVIA 2120 System (3대의 ADVIA 2120 System 평행시험에 대한 연구)

  • Chang, Sang-Wu;Cho, Eun-Hae;Kim, Nam-Yong;Chu, Kyung-Bok;Lee, Suk-Jong;Hong, Sung-No;Oh, Jong-Do
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.1
    • /
    • pp.16-21
    • /
    • 2006
  • Parallel testing means ordering a number of tests at the same time so abnormalities in any of the tests can be found quickly and used in making the diagnosis. This is a good medical strategy to eliminate diseases and it is relatively inexpensive if all the tests are potential sources of information and performed on the same analyzer. In regression, the equation for the straight line is recast as y = bx + a. This change in terminology leads to confusion. Here a is the y-intercept or constant and b is the coefficient or slope of the line. A few more words of caution about regression - as in all of statistics there are certain assumptions: the x value is a true measure, both X and Y distributions are normal, and homoscedasticity, i.e., the variance of y is the same for each value of x. In this study the linearity classification made by different scientists were always in agreement. Typical examples of curves that were considered linear are presented in Fig. 1-5. Because these automated procedures values were usually within five percent of each other the curvature could be easily detected. The plot of the WBC, RBC, hemoglobin, hematocrit and platelet concentrations from approximately 74.4 to $0{\times}10^3/{\mu}L$ and $80.4-0{\times}10^3/{\mu}L$, $5.6-0{\times}10^6/{\mu}L$ and $6.1-0{\times}1106/{\mu}L$, 18.3-0 g/dL and 19.0-0 g/dL, 54.1-0% and 56.8-0% and 642.0 to $0.03{\times}10^3{\mu}L$ and $754.0-0{\times}10^3/{\mu}L$ on the ADVIA 2120 C Versus and A and B typical of an acceptable linear study as shown in Fig. 1-5. The grand mean of R2, intercept and slope is 0.99898, 0.99459 and 1.54626.

  • PDF

Evaluate efficacy of fermented soybean(Bio-Peptone)cream in pruritus : Randomized, double-blinded, placebo-controlled, parallel-group clinical experiment study (피부 가려움증에 대한 대두(大豆) 발효물(Bio-Peptone)크림의 유효성 평가 : 무작위 배정, 양측 눈가림, 위약크림 대조, 평행 설계 연구)

  • An, Jae-Hyun;Jung, Hyun-A;Kim, Eun-Ju;Kim, Ae-Jung
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.33 no.3
    • /
    • pp.27-44
    • /
    • 2020
  • Objectives : The authors conducted randomized, Double-blinded, and placebo-controlled parallel-group clinical experiment study to evaluate efficacy of fermented soybean(Bio-Peptone)cream in pruritus. Methods : The research had been conducted for 4 months from the date of IRB approval(May 26 in 2017) to Sept 2017. The experiment started by randomly distributing 25 subjects with pruritus into experimental group and control group, respectively. The experimental group applied fermented soybean(Bio-Peptone)cream twice a day, in the morning and evening, for one week on itchy area. The effect of the product was evaluated by comparing the PSS(Patient subjective score), moisture level by measuring skin moisture content(Corneometer) and transepidermal water loss(Tewameter), and the Korean version of Skindex-29(index of quality of life improvement) before applying the cream, after applying the cream for one week and after stop applying the cream for one week. The control group conducted identical experiment with the experimental group, except the control group applied placebo instead of the fermented soybean(Bio-Peptone)cream. Results : Pruritus, criterion of the first validation testing, indicates fermented soybean(Bio-Peptone)cream tend to reduce pruritus compare to placebo, although the result is not statistically noticeable. Significant difference in reduction of prutitus, the second validation test was not discovered in both groups. Corneometer and life quality tend to be improved with soy cream than placebo, but not statistically effective and both groups did not show any difference in terms of Tewameter measurement. Conclusions : The result of clinical experiment didn't prove that the fermented soybean(Bio-Peptone)cream is more effective in reducing pruritus than placebo, statistically. The clinical use of soybean product for pruritus requires further studies to be verified.

True Triaxial Physical Model Experiment on Brittle Failure Grade and Failure Initiation Stress (취성파괴수준과 파괴개시시점에 관한 진삼축 모형실험연구)

  • Cheon, Dae-Sung;Park, Chan;Park, Chul-Whan;Jeon, Seok-Won
    • Tunnel and Underground Space
    • /
    • v.17 no.2 s.67
    • /
    • pp.128-138
    • /
    • 2007
  • At low in-situ stress, the continuity and distribution of natural fractures in rock mass predominantly control the failure processes. However at high in-situ stress, the failure process are affected and eventually dominated by stress-induced fractures preferentially growing parallel to the excavation boundary. This fracturing is often observed in brittle type of failure such as slabbing or spatting. Recent studies on the stress- or excavation-induced damage of rock revealed its importance especially in a highly stressed regime. In order to evaluate the brittle failure around a deep underground opening, physical model experiments were carried out. For the experiments a new tue triaxial testing system was made. According to visual observation and acoustic emission detection, brittle failure grades were classified under three categories. The test results indicate that where higher horizontal stress, acting perpendicular $(S_{H2})$ and parallel $(S_{H1})$ to the axis of the tunnel respectively, were applied, the failure grade at a constant vertical stress level (Sy) was lowered. The failure initiation stress was also increased with the increasing $S_{H1}\;and\;S_{H2}$. From the multi-variable regression on failure initiation stress and true triaxial stress conditions, $f(S_v,\;S_{H1},\;S_{H2})$ was proposed.