• Title/Summary/Keyword: Parallel Beam

Search Result 311, Processing Time 0.039 seconds

Evaluation of Nd:YAG Laser Beam Quality in Unstable Rosonators (불안전형 공진기를 갖는 Nd:YAG 레이저에서의 beam quality 평가)

  • 김광석;김정묵;김철중;이종민
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.60-66
    • /
    • 1994
  • First, the beam waist size of TE$M_{00}$ Nd:YAG laser mode with Positive Branch Unstable Resonator was calculated. and then, the output power, fundamental mode and multimode beam quality factor of PBUR were measured and compared with thouse of reference resonator with plane pallalel mirrors. In characterizing the beam quality, the $M^2$ concept was used. The focusability of laser beam in unstable resonators was discussed with this $M^2$.

  • PDF

A Study on the Rational Shear Model by interpretation of Stuttgart Beam Shear Test (Stuttgart 콘크리트 보 전단실험의 재해석을 통한 합리적 전단모델 연구)

  • 김우;모귀석;정제평
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.884-889
    • /
    • 2003
  • Based on the reinterpretation of the well-known relationship between shear and the rate of change of bending moment in a reinforced concrete beam subject to combined shear and moment loads, the shortcomings of present truss models are discussed. The core of the theory is that a new perspective on the shear strength can be gained by viewing the internal stress filed in terms of the superposition of two base components of shear resistance; arch action and beam action. The arch action can be designed using the simple truss having curved compression chord, while the beam action between the two chords can be modeled using a parallel chord truss with MCFT or RA-STM. The compatibility of deformation associated to the two action is taken into account by employing a characteristic factor a. The new model was examined by the Stuttgart beam shear tests, and the results show that the present approach provides good estimates of stirrup contribution and concrete contributions.

  • PDF

Development of Multi-channel Fiber Laser and Beam Alignment Method (다채널 광섬유 레이저 및 다중 빔 정렬 기술 개발)

  • Kim, Youngchan;Ryu, Daegeon;Noh, Young-Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.245-251
    • /
    • 2022
  • We have developed a multi-channel fiber laser for tiled laser beam combining and a laser output array system for multi-beam alignment. The fiber laser is a master oscillator power amplifier configuration that has a common seed, a preamplifier, and a 7-channel amplifier. The output power of each channel is more than 10 W. The laser output array system is a packed cylindrical configuration for a high fill-factor, and it has capabilities for collimation and tilt control with built-in PZT. Multi-beam alignment to a target is successfully implemented using PZT controlled with a stochastic parallel gradient descent (SPGD) algorithm.

A Two-Axis Ultra-precision Stage Using Flexure-type Parallel Linear Guide Mechanism (플렉셔 구조의 병렬형 선형 안내기구를 이용한 2 축 초정밀 스테이지)

  • Choi Kee-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.1 s.178
    • /
    • pp.129-135
    • /
    • 2006
  • In this study, a two-axis ultra-precision stage driven by piezoelectric elements is presented. The stage has a flexure-type parallel linear guide mechanism consisting of quad-symmetric simple parallel linear springs and quad-symmetric double compound linear springs. While the simple parallel linear springs guide the linear motion of a moving plate in the stage, the double compound linear springs follow the motion of the simple parallel linear spring as well as compensate the parasitic motions caused by the simple parallel linear springs. The linear springs are designed by rectangular beam type flexures that are deformed by bending deflection rather than axial extension, because the axial extension is smaller than the bending deflection at the same force. The designed guide mechanism is analyzed by finite element method(FEM). Then two-axis parallel linear stage is implemented by the linear guide mechanism combined with piezoelectric elements and capacitance type displacement sensors. It is shown that the manufactured ultra-precision stage achieves 3 nm of resolution in x- and y-axis within 30 ${\mu}m$ of operating range.

Study on Absorbed Dose Determination of Electron Beam Quality for Cross-calibration with Plane-parallel Ionization Chamber (평행평판형이온함의 교차교정 시 전자선 선질에 따른 흡수선량 결정에 대한 연구)

  • Rah, Jeong-Eun;Shin, Dong-Oh;Park, So-Hyun;Jeong, Ho-Jin;Hwang, Ui-Jung;Ahn, Sung-Hwan;Lim, Young-Kyung;Kim, Dong-Wook;Yoon, Myong-Geun;Shin, Dong-Ho;Lee, Se-Byeong;Suh, Tae-Suk;Park, Sung-Yong
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2009
  • Absorbed dose to water based protocols recommended that plane-parallel chambers be calibrated against calibrated cylindrical chambers in a high energy electron beam with $R_{50}$>7 $g/cm^2$ (E${\gtrsim}$16 MeV). However, such high-energy electron beams are not available at all radiotherapy centers. In this study, we are compared the absorbed dose to water determined according to cross-calibration method in a high energy electron beam of 16 MeV and in electron beam energies of 12 MeV below the cross-calibration quality remark. Absorbed dose were performed for PTW 30013, Wellhofer FC65G Farmer type cylindrical chamber and for PTW 34001, Wellhofer PPC40 Roos type plane-parallel chamber. The cylindrical and the plane-parallel chamber to be calibrated are compared by alternately positioning each at reference depth, $Z_{ret}=0.6R_{50}-0.1$ in water phantom. The $D_W$ of plane-parallel chamber are derived using across-calibration method at high-energy electron beams of 16, 20 MeV. Then a good agreement is obtained the $D_W$ of plane-parallel chamber in 12 MeV. The agreement between 20 MeV and 12 MeV are within 0.2% for IAEA TRS-398.

  • PDF

Growth and Characterization of ZnO Thin Films on R-plane Sapphire Substrates by Plasma Assisted Molecular Beam Epitaxy (R-면 사파이어 기판 위에 플라즈마 분자선 에피탁시법을 이용한 산화아연 박막의 성장 및 특성평가)

  • Han Seok-Kyu;Hong Soon-Ku;Lee Jae-Wook;Lee Jeong-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.923-929
    • /
    • 2006
  • Single crystalline ZnO films were successfully grown on R-plane sapphire substrates by plasma-assisted molecular beam epitaxy. Epitaxial relationship between the ZnO film and the R-plane sapphire was determined to be $[-1101]Al_2O_3{\parallel}[0001]ZnO,\;[11-20]Al_2O_2{\parallel}[-1100]ZnO$ based on the in-situ reflection high-energy electron diffraction analysis and confirmed again by high-resolution X-ray diffraction measurements. Grown (11-20) ZnO films surface showed mound-like morphology along the <0001>ZnO direction and the RMS roughness was about 4 nm for $2{\mu}m{\times}2{\mu}m$ area.

Multiple-Mode Structural Vibration Control Using Negative Capacitive Shunt Damping

  • Park, Chul-Hue;Park, Hyun-Chul
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1650-1658
    • /
    • 2003
  • This paper deals with a novel shunt circuit, which is capable of suppressing multimode vibration amplitudes by using a pair of piezoceramic patches. In order to describe the characteristic behaviors of a piezoelectric damper connected with a series and a parallel resistor-negative capacitor branch circuit, the stiffness ratio and loss factor with respect to the non-dimensional frequency are considered. The mechanism of the shunt damper is also described by considering a shunt voltage constrained by shunt impedance. To obtain a guideline model of the piezo/beam system with a negative capacitive shunting, the governing equations of motion are derived through the Hamilton's principle and a piezo sensor equation as well as a shunt-damping matrix is developed. The theoretical analysis shows that the piezo/beam system combined with a series and a parallel resistor-negative capacitor branch circuit developed in this study can significantly reduce the multiple-mode vibration amplitudes over the whole structural frequency range.

The vibration control of Flexible Manipulator using Parallel Fuzzy controller and Reference Trajectory Command (병렬퍼지 제어기와 기준궤적신호를 이용한 유연한 매니퓰레이터의 진동제어)

  • 박양수;박윤명
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.1
    • /
    • pp.61-66
    • /
    • 2002
  • A fuzzy control strategy is described which is utilized to control the joint angle and tip deflection in single flexible manipulator. In this paper, an existing model for a single flexible manipulator is used for the initial development of an FLC. One FLC is designed to govern the joint angle of the manipulator as it is rotated from one position to another, and the second FLC is designed to attenuate the tip deflection which result from joint angle body motion. Reference Trajectory Command is an important method to reduce vibration in flexible beam. This paper presents a very simple command control shaping which eliminates multiple mode residual vibration in a flexible beam combined parallel fuzzy controller. The effectiveness of proposed scheme is demonstrated through computer simulation.

  • PDF

A Study of Polarity Effect of Parallel Plate Type ionization Chamber with Different Volume (평행평판형 전리함의 두 전극간의 거리에 따른 극성효과 연구)

  • 윤형근;신교철
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.69-73
    • /
    • 2002
  • Exposure measurement data with parallel plate ionization chambers were known to depend on the polarity ($k_{pol}$) effect. In this work, the polarity effect were investigated for three parallel plate ionization chambers with different volume. The ionization chamber was fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far were 0.9, 1.9, and 3.1 co. High voltage generator was fabricated using the conventional 9 V batteries to apply the high voltage (300-500 V) to the electrode of the parallel plate ionization chamber. The gap between two electrodes ranged from 3, 6, and 10mm. As the result of our experiment, the polarity effect was within 0.5% in photon beam and 1% to 3.5% in the electron beams. Among electron beams, 16 MeV beam, which had highest energy, showed less polarity effect than electron beams with other energies.

  • PDF

Analysis of Cantilevered Structure Rotating on an Eccentric Axis (외팔보형 구조물의 편심축 회전운동 해석)

  • 조지현;윤신일;한상보
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.115-120
    • /
    • 2001
  • A gyroscope is a rotating body possessing one axis of symmetry and whose rotation about the symmetry axis is relatively large compared with the rotation about any other axis. Tuning fork is this type of structure that various modem gyro-sensors are based on. In this paper, dynamic behavior of a cantilevered beam subjected ta a base rotation with respect to the eccentric axis that is parallel to the beam axis is analyzed. The final equations of motion in terms of generalized coordinates can be solved with numerical scheme with various values of angular velocities and angular accelerations of the rotating axis. In contrast to the case of rotating cantilever beam like helicopter blade, the rotational motion with respect to the beam axis has effect to decrease the stiffness of the beam and has unstable region depending on the magnitude of the rotational angular velocity and angular acceleration.

  • PDF