• 제목/요약/키워드: PZT-based

검색결과 296건 처리시간 0.024초

비스무스계 무연 압전 세라믹스의 상전이 거동 및 전기 기계적 변형 특성에 대한 La2O3 도핑 효과 연구 (Effects of La2O3 Doping on Phase Transition Behavior and Electromechanical Strain Properties in Bismuth-Based Lead-Free Piezoelectric Ceramics)

  • 강은서;형성재;강유빈;박민성;즈엉 짱 안;이재신;한형수
    • 한국전기전자재료학회논문지
    • /
    • 제37권4호
    • /
    • pp.457-463
    • /
    • 2024
  • (Bi1/2Na1/2)TiO3(BNT) piezoelectric ceramics are one of the promising materials that can replace Pb(Zr, Ti)O3(PZT) piezoelectric ceramics due to the high electromechanical strain properties. However, it is still difficult to use practical applications because the required electric field for inducing electromechanical strain is relatively higher than that of PZT ceramics. To overcome this problem, it has been intensively studied on doping impurity or modifying other ABO3 for BNT-based piezoelectric ceramics. Therefore, this study investigated the effects of La2O3 doping on the phase transition behavior and electromechanical strain properties in BNT-SrTiO3 (BNT-ST) lead-free piezoelectric ceramics. In the case of the temperature-dependent dielectric properties, it was confirmed that a phase transition from ferroelectrics to relaxors is induced with increasing La2O3 content. As a result, the electromechanical strain properties of BNT-ST ceramics were improved. The highest Smax/Emax value corresponding to 300 pm/V was obtained at 2 mol% La2O3-dopped BNT-ST ceramics. Accordingly, this study successfully demonstrated that La2O3 doping is effective on the inducing phase transition from ferroelectrics to relaxors and the improving electromechanical strain properties of BNT-ST lead-free piezoelectric ceramics.

On time reversal-based signal enhancement for active lamb wave-based damage identification

  • Wang, Qiang;Yuan, Shenfang;Hong, Ming;Su, Zhongqing
    • Smart Structures and Systems
    • /
    • 제15권6호
    • /
    • pp.1463-1479
    • /
    • 2015
  • Lamb waves have been a promising candidate for quantitative damage identification for various engineering structures, taking advantage of their superb capabilities of traveling for long distances with fast propagation and low attenuation. However, the application of Lamb waves in damage identification so far has been hampered by the fact that the characteristic signals associated with defects are generally weaker compared with those arising from boundary reflections, mode conversions and environmental noises, making it a tough task to achieve satisfactory damage identification from the time series. With awareness of this challenge, this paper proposes a time reversal-based technique to enhance the strength of damage-scattered signals, which has been previously applied to bulk wave-based damage detection successfully. The investigation includes (i) an analysis of Lamb wave propagation in a plate, generated by PZT patches mounted on the structure; (ii) an introduction of the time reversal theory dedicated for waveform reconstruction with a narrow-band input; (iii) a process of enhancing damage-scattered signals based on time reversal focalization; and (iv) the experimental investigation of the proposed approach to enhance the damage identification on a composite plate. The results have demonstrated that signals scattered by delamination in the composite plate can be enhanced remarkably with the assistance of the proposed process, benefiting from which the damage in the plate is identified with ease and high precision.

비스무스계 무연 압전세라믹스의 저전계 변형특성 향상을 위한 세라믹/세라믹 복합소재 기술 (A Brief Review of Enhancing Incipient Piezostrains: Approach by Ceramic/Ceramic Composites)

  • 한형수;즈엉 짱 안;안창원;조욱;이재신
    • 세라미스트
    • /
    • 제23권1호
    • /
    • pp.89-100
    • /
    • 2020
  • Abnormally large electromechanical strain properties have been reported in bismuth-based piezoelectric ceramics, which cast a promise for replacing the market-dominating PZT-based piezoelectric ceramics in actuator applications. In spite of these large strains in bismuth-based piezoelectric ceramics, there still remains a critical issue for its safe transfer to practical applications, representatively, a relatively high operating field required to obtain the large strain properties. To overcome the challenge, much attention has been paid to so-called 0-3(or 3-0) type ceramic/ceramic composite approach to better tailoring the strain properties of bismuth-based piezoelectric ceramics. The approach turns out to be highly effective, leading to a drastic decrease in the operating electric field for these materials. Besides, both extensive and intensive search for the related mechanism revealed that the reduction in the operating electric field is largely due to the contribution from polarization coupling or strain coupling model between two different ceramics. This article reviews the status of the art in the development of novel ceramic/ceramic composites to make large incipient piezostrains in bismuth-based lead-free piezoelectric ceramics practical.

Piezoelectric nanocomposite sensors assembled using zinc oxide nanoparticles and poly(vinylidene fluoride)

  • Dodds, John S.;Meyers, Frederick N.;Loh, Kenneth J.
    • Smart Structures and Systems
    • /
    • 제12권1호
    • /
    • pp.55-71
    • /
    • 2013
  • Structural health monitoring (SHM) is vital for detecting the onset of damage and for preventing catastrophic failure of civil infrastructure systems. In particular, piezoelectric transducers have the ability to excite and actively interrogate structures (e.g., using surface waves) while measuring their response for sensing and damage detection. In fact, piezoelectric transducers such as lead zirconate titanate (PZT) and poly(vinylidene fluoride) (PVDF) have been used for various laboratory/field tests and possess significant advantages as compared to visual inspection and vibration-based methods, to name a few. However, PZTs are inherently brittle, and PVDF films do not possess high piezoelectricity, thereby limiting each of these devices to certain specific applications. The objective of this study is to design, characterize, and validate piezoelectric nanocomposites consisting of zinc oxide (ZnO) nanoparticles assembled in a PVDF copolymer matrix for sensing and SHM applications. These films provide greater mechanical flexibility as compared to PZTs, yet possess enhanced piezoelectricity as compared to pristine PVDF copolymers. This study started with spin coating dispersed ZnO- and PVDF-TrFE-based solutions to fabricate the piezoelectric nanocomposites. The concentration of ZnO nanoparticles was varied from 0 to 20 wt.% (in 5 % increments) to determine their influence on bulk film piezoelectricity. Second, their electric polarization responses were obtained for quantifying thin film remnant polarization, which is directly correlated to piezoelectricity. Based on these results, the films were poled (at 50 $MV-m^{-1}$) to permanently align their electrical domains and to enhance their bulk film piezoelectricity. Then, a series of hammer impact tests were conducted, and the voltage generated by poled ZnO-based thin films was compared to commercially poled PVDF copolymer thin films. The hammer impact tests showed comparable results between the prototype and commercial samples, and increasing ZnO content provided enhanced piezoelectric performance. Lastly, the films were further validated for sensing using different energy levels of hammer impact, different distances between the impact locations and the film electrodes, and cantilever free vibration testing for dynamic strain sensing.

Structural health monitoring of high-speed railway tracks using diffuse ultrasonic wave-based condition contrast: theory and validation

  • Wang, Kai;Cao, Wuxiong;Su, Zhongqing;Wang, Pengxiang;Zhang, Xiongjie;Chen, Lijun;Guan, Ruiqi;Lu, Ye
    • Smart Structures and Systems
    • /
    • 제26권2호
    • /
    • pp.227-239
    • /
    • 2020
  • Despite proven effectiveness and accuracy in laboratories, the existing damage assessment based on guided ultrasonic waves (GUWs) or acoustic emission (AE) confronts challenges when extended to real-world structural health monitoring (SHM) for railway tracks. Central to the concerns are the extremely complex signal appearance due to highly dispersive and multimodal wave features, restriction on transducer installations, and severe contaminations of ambient noise. It remains a critical yet unsolved problem along with recent attempts to implement SHM in bourgeoning high-speed railway (HSR). By leveraging authors' continued endeavours, an SHM framework, based on actively generated diffuse ultrasonic waves (DUWs) and a benchmark-free condition contrast algorithm, has been developed and deployed via an all-in-one SHM system. Miniaturized lead zirconate titanate (PZT) wafers are utilized to generate and acquire DUWs in long-range railway tracks. Fatigue cracks in the tracks show unique contact behaviours under different conditions of external loads and further disturb DUW propagation. By contrast DUW propagation traits, fatigue cracks in railway tracks can be characterised quantitatively and the holistic health status of the tracks can be evaluated in a real-time manner. Compared with GUW- or AE-based methods, the DUW-driven inspection philosophy exhibits immunity to ambient noise and measurement uncertainty, less dependence on baseline signals, use of significantly reduced number of transducers, and high robustness in atrocious engineering conditions. Conformance tests are performed on HSR tracks, in which the evolution of fatigue damage is monitored continuously and quantitatively, demonstrating effectiveness, adaptability, reliability and robustness of DUW-driven SHM towards HSR applications.

유도파에 대한 푸리에 및 웨이브렛 변환을 이용한 록볼트의 건전도 평가 (Guidedwave-induced rockbolt integrity using Fourier and wavelet transforms)

  • 이인모;김현진;한신인;이종섭
    • 한국터널지하공간학회 논문집
    • /
    • 제9권4호
    • /
    • pp.403-413
    • /
    • 2007
  • 터널과 같은 지하공간 구조물에 있어서 록볼트는 숏크리트와 함께 주요 지보재 중의 하나이며, 그러므로 록볼트 시공품질 정도에 따라 이러한 지중구조물의 안정성에 큰 영향을 미치게 된다. 본 연구의 목적은 록볼트를 따라 전파되는 유도파에 대하여 푸리에 및 웨이브렛 변환을 이용하여 록볼트의 건전도를 평가하는데 있다. 각기 다른 결함비율을 가진 다섯 개의 록볼트 시험체를 제작하여 콘크리트 블록에 매설한 후, PZT($Pb[Zr_xTi_{1-x}]O_3$: lead zirconate titanate) 엘리먼트로 유도파를 발생시키고 AE(acoustic emission) 센서를 이용하여 신호를 측정하였다. 수집된 신호는 푸리에 변환을 이용하여 주파수 영역에서 분석하였고, 가버 웨이브렛을 사용한 웨이브렛 변환을 이용하여 시간-주파수영역에서 분석하였다. 푸리에 변환을 이용하여 얻은 스펙트럼을 분석하면 록볼트의 결함비율이 증가함에 따라 고주파 대역 에너지의 비율이 증가하는 것을 알 수 있다. 또한, 시간-주파수 영역에서의 각 파군별 최대 에너지가 나타나는 지점의 시간차는 각 반사파군 간의 이동 시간차를 나타내며, 이를 통해 계산된 유도파의 에너지 속도는 록볼트의 공동결함비율이 증가함에 따라 증가하는 것으로 나타났다. 본 연구는 스펙트럼 비와 에너지 속도가 록볼트의 건전도 평가에 있어서 하나의 지표가 될 수 있음을 보여준다.

  • PDF

도로용 압전발전체 시험모듈 설계를 위한 기초 실험 연구 (A Fundamental Study for Design of Electric Energy Harvesting Device using PZT on the Road)

  • 이재준;류승기;문학룡;권수안
    • 한국도로학회논문집
    • /
    • 제13권4호
    • /
    • pp.159-166
    • /
    • 2011
  • 국제 사회는 산업경제의 발달과 더불어 온실가스 배출량이 날로 증가하고 있으며, 이로 인한 기후 변화 피해가 날로 심각해지고 있는 상황에서 온실가스 배출량을 줄이기 위해 전세계가 노력을 하고 있다. 정부는 온실가스 배출량을 감축하여 지구온난화를 막기 위해 "저탄소 녹색성장"의 국가정책 하에서 신재생에너지와 같은 친환경적인 녹색산업에 많은 관심과 투자에 집중하고 있다. 신재생에너지 분야는 태양력, 풍력, 수력, 조력 등 자연에너지를 활용하는 기술에 투자하면서 관련 핵심 부품 및 소재기술은 기술적으로 발전하고 있다. 반면에, 도로 공간에 존재하는 다양한 미활용 에너지를 이용하는 기술에 대한 연구는 세계적으로도 미흡한 실정인데, 본 논문에서는 이러한 도로 공간에서의 미활용 에너지를 통해 전기를 수확하는 기술에 대한 기초적인 실험방법과 결과를 제시하였다. 도로 공간에서의 미활용 에너지는 다양한 자원이 있을 수 있는데, 예를 들면 도로 주행 차량의 압력 및 충격 에너지, 도로 포장면의 복사열, 도로 소음 및 파동 등이다. 본 논문은 도로를 주행하는 차량으로부터 전기를 수확하기 위한 압전체 형상을 제안하였으며, 이를 검증하는 몇 가지의 기초 실험을 실시하였다. 즉, 압력을 전기로 변환하는 압전기술을 활용한 것으로 국내에서 쉽게 생산하는 PZT 세라믹을 이용하여 충격하중에 따라 발생하는 전압을 측정하였고, 아스팔트 및 콘트리트 포장 조건에 따른 압전 발전 실험을 실시하여 에너지 수확 성능을 비교 분석하였다.

입자 크기가 PZT계 압전 후막의 물성에 미치는 영향 (Effects of Particle Size on Properties of PZT -Based Thick Films)

  • 김동명;김정석;천채일
    • 한국세라믹학회지
    • /
    • 제41권5호
    • /
    • pp.375-380
    • /
    • 2004
  • 알루미나 기판 위에 Pb(Ni$_{1}$3/Nb$_{2}$3/)O$_3$-PbZrO$_3$-PbTiO$_3$ 후막을 스크린 인쇄한 후 800∼100$0^{\circ}C$에서 소결하여 압전 후막을 제조하였다. 마모 밀과 볼 밀 분쇄법을 이용하여 입자 크기가 서로 다른 압전 분말을 제조하였으며, 압전 분말의 입자 크기가 후막의 미세구조와 전기적 성질에 미치는 영향을 조사하였다. 마모 밀링한 분말의 평균 입자 크기는 0.44 $\mu\textrm{m}$로 볼 밀링한 분말의 평균 입자 크기, 2.87 $\mu$m 보다 훨씬 작았다. 후막을 80$0^{\circ}C$에서 소결하였을 때는 마모 밀링한 분말로 제조한 후막의 입자 크기가 볼 밀링한 분말로 제조한 후막의 입자 크기보다 더 작았으며, 소결 온도가 증가함에 따라 그 차이가 점차 감소하였다. 그리고, 전체 소결 온도 구간에서 마모 밀링한 분말로 제조한 후막이 볼 밀링한 분말로 제조한 후막보다 균일하고 치밀한 미세구조를 보였다. 소결 온도가 90$0^{\circ}C$ 이상일 때, 마모 밀링한 분말로 제조한 후막이 볼 밀링한 분말로 제조한 후막보다 우수한 전기적 성질을 가졌다. 90$0^{\circ}C$에서 소결한 마모 밀링한 분말로 제조한 후막의 유전상수($\varepsilon$$_{r}$), 잔류분극(P$_{r}$), 항전계(E$_{c}$)는 각각 559, 16.3 $\mu$C/$cm^2$, 51.3 kV/cm이었다.다..

마이크로 BGA 패키지의 볼 형상 시각검사를 위한 모아레 간섭계 기반 3차원 머신 비젼 시스템 (Three-dimensional Machine Vision System based on moire Interferometry for the Ball Shape Inspection of Micro BGA Packages)

  • 김민영
    • 마이크로전자및패키징학회지
    • /
    • 제19권1호
    • /
    • pp.81-87
    • /
    • 2012
  • 본 논문에서는 마이크로 BGA 패키지 내외부의 마이크로 볼의 3차원 형상을 측정하는 광학 측정 시스템을 제안하고 이를 구현한다. 대부분의 시각 검사 시스템은 마이크로 볼의 복잡한 반사 특성 때문에 검사에 어려움을 겪고 있다. 정확한 형상의 측정을 위해서, 특별히 설계된 시각 센서 시스템을 제안하고, 위상이송 모아레 간섭계의 측정원리에 기반한 형상측정 알고리즘을 제안한다. 센서 시스템은 4개의 서브시스템을 보유한 패턴 투사 시스템과 영상획득 시스템으로 구성된다. 패턴 투사용 서브시스템은 공간상으로 서로 상이한 투사 방향을 가지며, 이는 측정 물체에 각기 다른 입사 방향을 가지는 패턴 조명이 투사될 수 있도록 하는 것을 목적으로 한다. 위상이송 모아레 간섭계의 구현을 위한 정밀 위상이송을 위해서, 각 서브시스템의 패턴 격자는 PZT 구동기를 이용하여 일정 간격으로 이송한다. 최종적으로 측정되는 마이크로 볼의 경면반사와 그림자 영역을 효과적으로 제거하기 위해서, 다중 패턴 투사 시스템과 영상획득 시스템을 구현하고, 이를 테스트한다. 특히, 다중 프로젝션을 이용하여 획득되는 다중 높이 정보를 효과적으로 융합하기 위하여, 베이지안 센서 융합 이론을 기반으로한 센서 융합 알고리즘이 제안된다. 제안되는 시스템의 원리검증과 성능확인을 위해, 마이크로 BGA볼과 기판 범프의 측정대상물에 대해서, 측정 반복성을 중심으로 실험이 수행되었으며, 획득된 실험 결과를 분석하고 논의한다.

Quad Chip 외관 불량 검사를 위한 2D/3D 광학 시스템 (2D/3D Visual Optical Inspection System for Quad Chip)

  • 한창호;이상준;박철근;이지연;유영기;고국원
    • 한국산학기술학회논문지
    • /
    • 제17권1호
    • /
    • pp.684-692
    • /
    • 2016
  • LQFP/TQFP(Low-profile Quad Flat Package/Thin Quad Flat Package) 패키지 공정에서는 높은 수준의 품질 관리를 위해 3차원 형상 측정 방법을 도입하고 있어 본 연구에서는 최종 외관 불량 검사를 위하여 projection moire 방식의 3D 영상 검사를 위한 광학 시스템과 영상처리 알고리즘을 개발하였다. LQFP/TQFP칩에서 발생하는 불량들은 2D 불량항목과 3D 불량 항목으로 구분하여 불량 항목을 상세히 정의하였다. 광학계를 설계함에 있어서 2D 측정 광학계는 돔 조명을 사용하여 일정한 광분포도를 갖도록 설계하고, 3D 측정 광학계는 PZT를 이용하여 모아레 패턴이 90도씩 정확한 위상을 갖도록 이송을 위한 기구적 메커니즘을 설계한다. 물체의 모아레 측정시 위상 변화에서 나타나는 $2{\pi}$ 모호성을 해결하기 위해 측정된 모아레 무늬를 비교하여 $2{\pi}$ 위상의 모호성이 발생하는 부분에서 수정된 다른 위상을 참고하는 알고리즘을 적용하였다. 개발된 검사 시스템은 LQFP/TQFP 외관 검사 공정에 적용하였으며, 실험에서 최대 높이의 측정 오차는 $1.34{\mu}m$ 이내로, 3차원 외관형상 불량 검사 조건을 만족할 만한 성능을 보였다.