• 제목/요약/키워드: PV Industry

검색결과 117건 처리시간 0.029초

태양광 발전 시스템을 위한 유비쿼터스 네트워킹 기반 지능형 모니터링 및 고장진단 기술 (Ubiquitous Networking based Intelligent Monitoring and Fault Diagnosis Approach for Photovoltaic Generator Systems)

  • 조현철;심광열
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1673-1679
    • /
    • 2010
  • A photovoltaic (PV) generator is significantly regarded as one important alternative of renewable energy systems recently. Fault detection and diagnosis of engineering dynamic systems is a fundamental issue to timely prevent unexpected damages in industry fields. This paper presents an intelligent monitoring approach and fault detection technique for PV generator systems by means of artificial neural network and statistical signal detection theory. We devise a multi-Fourier neural network model for representing dynamics of PV systems and apply a general likelihood ratio test (GLRT) approach for investigating our decision making algorithm in fault detection and diagnosis. We make use of a test-bed of ubiquitous sensor network (USN) based PV monitoring systems for testing our proposed fault detection methodology. Lastly, a real-time experiment is accomplished for demonstrating its reliability and practicability.

국내외 건물 적용 태양광발전 보급 프로그램 현황 (Status of Photovoltaic(PV) Distribution Programs for Applied Buildings)

  • 박경은;유권종;김준태;강기환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1486-1488
    • /
    • 2004
  • The global photovoltaic(PV) market is increasing at an annual rate of about $30\%$. A major share of the market has been taken up by building integrated photovoltaic. This paper presents an overview about status of the PV distribution programs for appling to building in the domestic and Japan, USA and Europe which have been playing a leading part in photovoltaic industry. From the results of this paper, we will intend to suggest a suitable future course for domestic PV distribution.

  • PDF

프레넬 렌즈를 이용한 집광 시 단결정 실리콘 태양전지의 전기적 특성 (Electrical Characteristics of Mono Crystalline Silicon Solar Cell for Concentrating PV System using Fresnel Lenses)

  • 강경찬;강기환;유권종;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.218-219
    • /
    • 2007
  • Silicon feed stock shortage have acted as major restraints for growth of photovoltaic industry. Concentrating photovoltaic (CPV) system will reduce the use of silicon PV materials. This paper presents the application possibility of mono-crystalline silicon solar cell, which has increased in market share, for PV concentrator. We measured the power of solar cell using sun simulator and I-V curve tracer and compared the results. The comparison of results showed that the concentrated solar cell generated the power more approximately 7 times than without concentration in spite of non-heat sink. If CPV technology included heat sink combines already developed PV tracking system, it will have a merit economically.

  • PDF

매설지선 방식을 적용한 에너지 자립마을용 수상 태양광 발전 시스템의 접지저항 분석 (Analysis of Grounding Resistance for Zero Energy Town Floating PV System Using Underground Wiring)

  • 고재우;임종록;;차혜림;김시한;이창구;안형근
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.303-306
    • /
    • 2016
  • Floating PV system is installed on the water such as artificial lake, reservoir, river for the purposes of zero energy town and/or large scale of PV station. There are electrical gains from cooling effect by water and reflection of water surface. Particularly, floating PV power station with high efficiency solar cell modules receives a lot of attention recently. Floating PV system is installed on the water, which means grounding method to the frame of solar cell and electrical box such as connector band and distribution panelboard should be applied in different way from grounding method of PV system on land. The grounding resistance should be 10[${\Omega}$] in case the voltage is over 400[V] in accordance with Korean Standard. The applicable parameters are the resistivity of water in various circumstances, depth of water, and length of electrode in order to meet 10[${\Omega}$] of grounding resistance. We calculated appropriate length of the electrode on the basis of theoretical equation of grounding resistance and analyzed the relation between each parameters through MATLAB simulation. This paper explains grounding system of floating PV power station and presents considerations on grounding design according to the resistivity of water.

국내 태양광발전용 마이크로 인버터 기술기준에 관한 연구 (A Study on the Technical Standard of Micro-Inverter for Domestic Photovoltaic Power Generation)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.175-180
    • /
    • 2019
  • 스트링 인버터의 정격전력이 낮은 단점을 보완하기 위하여 전력변환장치(PCS: Power Conditioning System)를 마이크로 인버터를 사용하여 기존 PCS와 비교하여 마이크로 인버터의 필요성과 향후의 발전 방향을 고찰하고자 한다. 현재 가정용 태양광발전 시스템에서는 스트링 인버터를 사용해 왔으며 유럽을 시작으로 스트링 인버터의 단점을 보완할 수 있는 마이크로 인버터(PV-MIC)의 연구 및 보급률이 확장 되고 있는 실정이다. 그러나 국내 태양광인버터 업계에서는 태양광발전용 마이크로 인버터(PV-MIC)에 대한 정확한 기술기준 및 시험 측정 장비 및 관련 시험방법 부재가 제품 개발에 걸림돌이 되고 있다. 따라서 본 논문에서는 마이크로 인버터(PV-MIC)의 특성을 고려하여 시험측정 장비 및 관련 기술기준 연구를 통해 선진기술 변화에 뒤쳐지지 않도록 경쟁력을 갖출 수 있는데 목적을 둔다.

Global Transcriptome Profiling of Xanthomonas oryzae pv. oryzae under in planta Growth and in vitro Culture Conditions

  • Lee, So Eui;Gupta, Ravi;Jayaramaiah, Ramesha H.;Lee, Seo Hyun;Wang, Yiming;Park, Sang-Ryeol;Kim, Sun Tae
    • The Plant Pathology Journal
    • /
    • 제33권5호
    • /
    • pp.458-466
    • /
    • 2017
  • Xanthomonas oryzae pv. oryzae (Xoo), the causative agent of bacterial blight, is a major threat to rice productivity. Here, we performed RNA-Seq based transcriptomic analysis of Xoo transcripts isolated under in planta growth (on both susceptible and resistant hosts) and in vitro culture conditions. Our in planta extraction method resulted in successful enrichment of Xoo cells and provided RNA samples of high quality. A total of 4,619 differentially expressed genes were identified between in planta and in vitro growth conditions. The majority of the differentially expressed genes identified under in planta growth conditions were related to the nutrient transport, protease activity, stress tolerance, and pathogenicity. Among them, over 1,300 differentially expressed genes were determined to be secretory, including 184 putative type III effectors that may be involved in Xoo pathogenicity. Expression pattern of some of these identified genes were further validated by semi-quantitative RT-PCR. Taken together, these results provide a transcriptome overview of Xoo under in planta and in vitro growth conditions with a focus on its pathogenic processes, deepening our understanding of the behavior and pathogenicity of Xoo.

태양광 발전시스템의 신뢰성 향상을 위한 태양전지의 PID 저감 기술의 타당성 검토 (A Study on Validity of Anti-PID Technology of Solar Cell for the High Reliability of Photovoltaics System)

  • 백성선;백승엽;정태욱;조진형
    • 산업경영시스템학회지
    • /
    • 제36권2호
    • /
    • pp.32-38
    • /
    • 2013
  • In recent years, anti-PID (Potential Induced Degradation) technologies have been studied and developed at various stages throughout the solar value chain from solar cells to systems in an effort to enhance long-term reliability of the photovoltaics (PV) system. Such technologies and applications must bring in profits economically for both manufacturers of solar cell/module and investors of PV systems, simultaneously for the development of the PV industry. In this study two selected anti-PID technologies, ES (modification of emitter structure) and ARC (modification of anti-reflective coating) were compared based on the economic features of both a cell maker with 60MW production capacity and an investor of 1MW PV power plant. As a result of this study, it is shown that ARC anti-PID technology can ensure more profits over ES technology for both the cell manufacturer and the investor of PV power plant.

태양광발전소 운영유지보수를 위한 이기종 장비 지원 모니터링 시스템 (Heterogeneous Equipment Support Monitoring System for Operation and Maintenance of Solar power plant)

  • 임수창;홍석훈;박철영;조현욱;송법성;김종찬
    • 한국멀티미디어학회논문지
    • /
    • 제23권9호
    • /
    • pp.1171-1180
    • /
    • 2020
  • The number of the PV systems installed in south korea has been gradually increasing. Interest of operation & management of PV System is rising up as PV System installation trends to increase. The vital function of operation & management is the monitoring system. Most monitoring systems are only available for equipment of suppliers and manufacturers. In this study, a monitoring system was implemented to support multi-domain equipment (inverter, junction box, water distribution board, environmental sensors) that are not limited to specific manufacturers. Monitoring system includes a visualization function, which makes it easy for users to check the power generation and the operation status of the equipment of PV System. In the future, this monitoring system will be utilized as an operation & maintenance foundation element in the PV system industry.

LabVIEW를 이용한 철도 선로전환기 융설용 태양광-풍력 발전 모니터링 시스템의 적용 방법 (The Application of Monitoring System Methods of Photovoltaic-Wind Power Generation for Railway Switching Point Heating Using LabVIEW)

  • 김대년;김덕현;최정원
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.9-14
    • /
    • 2013
  • The monitoring system is an absolutely required system for improving a performance to consider the situation for the hybrid generation of the photovoltaic (PV) and wind power (WP) energy experimental research complex. This system is to monitor with the railroad switching point heating system using LabVIEW to the hybrid generation of the PV and WP. The monitoring system of this paper is a program monitoring the hour, day and total of the voltage and current that made from the hybrid generation of PV and WP. In experiment, we acquired the power data according to time at the day of PV and WP. We have confirmed the possibility of the real time monitoring system using LabVIEW with the railroad switching point heating system as the hybrid generation of the PV and WP.

태양광 발전 시스템의 시공간적 잠재성 평가 소프트웨어 개발 (Assessment of Distributed and Dynamic Potential of Photovoltaic Systems in Urban Areas)

  • 최요순
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.59.2-59.2
    • /
    • 2011
  • This study presents a new method for coupling ArcGIS (popular GIS software) with TRaNsient SYstems Simulation (TRNSYS, reference software for researchers and engineers around the world) to use capabilities of the 4 and 5-parameter PV array performance models within the ArcGIS environment. Using the validated and industry-proven solar energy simulation models implemented in TRNSYS and other built-in ArcGIS functionalities, dynamic characteristics of distributed PV potential in terms of hourly, daily or monthly power outputs can be investigated with considerations of diverse options in selecting and mounting PV panels. In addition, the proposed method allows users to complete entire procedures in a single framework (i.e., a preliminary site survey using 3D building models, shading analyses to investigate usable rooftop areas with considerations of different sizes and shapes of buildings, dynamic energy simulation to examine the performances of various PV systems, visualization of the simulation results to understand spatially and temporally distributed patterns of PV potential). Therefore tedious tasks for data conversion among multiple softwares can be significantly reduced or eliminated. While the programming environment of TRNSYS is proprietary, the redistributable executable, simulation kernel and simulation engine of TRNSYS can be freely distributed to end-users. Therefore, GIS users who do not have a license of TRNSYS can also use the functionalities of solar energy simulation models within ArcGIS.

  • PDF