• Title/Summary/Keyword: PUI

Search Result 38, Processing Time 0.027 seconds

3D Physical User Interface System using a Dominant Eye and an Index Fingertip (주시안과 검지 끝 점을 이용한 3차원 물리 사용자 인터페이스 시스템)

  • Kim, Kyung-Ho;Ahn, Jeeyun;Lee, Jongbae;Kwon, Heeyong
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.2
    • /
    • pp.138-146
    • /
    • 2013
  • In this paper, we propose a new 3D PUI(Physical User Interface) system in which the index fingertip points and moves a mouse position on a given monitor screen. There are two 3D PUI schemes to control smart devices like smart TVs remotely, the relative pointing one and the absolute pointing one. The former has a problem in that it does not match the human perception process, and the latter requires excessive movement of the body. We combined the relative one and the absolute one, and develop a new intuitive and user-friendly pointing method, 3D PUI. It requires an establishment of a pyramid shape visible area (view volume) to point a mouse position on a screen with the dominant eye. In order to maintain the real-time view volume, however, it requires large computation depending on the movement of the dominant eye. We optimized the computation of the view volume in which it determines the internal and external position on the screen. In addition, Kalman filter is applied with tracing of the mouse pointer position to stabilize the trembling of the pointer and offers the user ease of use.

Ergonomic Improvement of Operation Console for Pilot Aptitude Research Equipment (조종적성 검사/연구 장비 운용 Console의 인간공학적 개선)

  • Kim, Sungho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.42-49
    • /
    • 2018
  • Pilot Aptitude Research Equipment (PARE) is a simulator developed to measure or research pilot aptitude and train for student pilots. Design of an ergonomic PARE operation console is required to operate the equipment effectively. This study carried out five steps : (S1) operator questionnaire survey, (S2) anthropometric design formula development, (S3) usability evaluation, (S4) improvement design, and (S5) validation considering both Physical User Interface (PUI) and Graphic User Interface (GUI) of PARE operation console. The operator questionnaire surveyed needs for each PUI and GUI part of the console from two PARE actual operators. In terms of PUI, the anthropometric design formula was developed by using design variables, body dimensions, target population characteristics, and reference posture related to the PARE console. In terms of GUI, the usability evaluation was conducted by three usability testing experts with a 7-point scale (1 : very low, 4 : neutral, 7 : very high) on GUI of the PARE operation console by seven usability criteria. The improved PARE operation console was designed to reflect the optimal values of design variables calculated from design formula, the results from usability testing, and the operator's needs. The improvement effect was observed by 20 people who had experience with the PARE operation console. As a result of the validation, monitor visibility and cockpit visibility for the improved PUI design and visibility and efficiency for the improved GUI design were significantly increased by more than 90% respectively. The improved design of the PARE operation console in this study can contribute to enhance operation performance of the PARE.

Effect of three different irrigation solutions applied by passive ultrasonic irrigation

  • Llena, Carmen;Forner, Leopoldo;Cambralla, Raquel;Lozano, Adrian
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.143-148
    • /
    • 2015
  • Objectives: This study evaluated the maximum depth and percentage of irrigant penetration into dentinal tubules by passive ultrasonic irrigation (PUI). Materials and Methods: Thirty extracted human teeth were instrumented and divided into three groups. According to final irrigation regimen, 5.25% sodium hypochlorite (Group A, NaOCl), 2% chlorhexidine (Group B, CHX) and saline solution (Group C, control group) were applied with Irrisafe 20 tips (Acteon) and PUI. Irrigant was mixed with 0.1% rhodamine B. Sections at 2 mm, 5 mm, and 8 mm from the apex were examined with confocal laser scanning microscopy (CLSM). The percentage and maximum depth of irrigant penetration were measured. Kruskal-Wallis test and Mann-Whitney test were performed for overall comparison between groups at each level and for pairwise comparison, respectively. Within a group, Wilcoxon test was performed among different levels. p values less than 0.05 were considered significant. Results: In all groups, highest penetration depth and percentage of penetration were observed at the 8 mm level. At 2 mm level, Groups A and B had significantly greater depths and percentages in penetration than Group C (p < 0.05), but there were no significant differences between Groups A and B. At 5 mm level, penetration depths and percentage of penetration was not significantly different among the groups. Conclusions: NaOCl and CHX applied by PUI showed similar depth and percentage of penetration at all evaluated levels.

Smear layer removal by passive ultrasonic irrigation and 2 new mechanical methods for activation of the chelating solution

  • Ricardo Machado ;Isadora da Silva;Daniel Comparin;Bianca Araujo Marques de Mattos ;Luiz Romulo Alberton ;Ulisses Xavier da Silva Neto
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.1
    • /
    • pp.11.1-11.11
    • /
    • 2021
  • Objectives: The aim of this study was to compare smear layer removal by conventional application (CA), passive ultrasonic irrigation (PUI), EasyClean (EC), and XP-Endo Finisher (XPF), using 17% ethylenediaminetetraacetic acid (EDTA) after chemomechanical preparation, as evaluated with scanning electron microscopy (SEM). Materials and Methods: Forty-five single-rooted human mandibular premolars were selected for this study. After chemomechanical preparation, the teeth were randomly divided into 5 groups according to the protocol for smear layer removal, as follows: G1 (control): CA of distilled water; G2 (CA): CA of 17% EDTA; G3 (PUI): 17% EDTA activated by PUI; G4 (EC): 17% EDTA activated by EC; and G5 (XPF): 17% EDTA activated by XPF. SEM images (×1,000) were obtained from each root third and scored by 3 examiners. Data were evaluated using the Kruskal-Wallis and Dunn tests (p < 0.05). Results: In the apical third, there were no statistically significant differences among the groups (p > 0.05). In the cervical and middle thirds, the experimental groups performed better than the control group (p < 0.05); however, G2 presented better results than G3, G4, and G5 (p < 0.05), which showed no differences among one another (p > 0.05). Conclusions: No irrigation method was able to completely remove the smear layer, especially in the apical third. Using CA for the chelating solution performed better than any form of activation.

Fostering Mathematical Thinking and Creativity: The Percent Problem

  • Foong, Pui Yee
    • Research in Mathematical Education
    • /
    • v.14 no.1
    • /
    • pp.51-65
    • /
    • 2010
  • Open-ended problems can foster deeper understanding of mathematical ideas, generating creative thinking and communication in students. High-order thinking tasks such as open-ended problems involve more ambiguity and higher level of personal risks for students than they are normally exposed to in routine problems. To explore the classroom-based factors that could support or inhibit such higher-order processes, this paper also describes two cases of Singapore primary school teachers who have successfully or unsuccessfully implemented an open-ended problem in their mathematics lessons.

Dentinal tubule penetration of sodium hypochlorite in root canals with and without mechanical preparation and different irrigant activation methods

  • Renata Aqel de Oliveira;Theodoro Weissheimer;Gabriel Barcelos So ;Ricardo Abreu da Rosa ;Matheus Albino Souza;Rodrigo Goncalves Ribeiro ;Marcus Vinicius Reis So
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.1
    • /
    • pp.1.1-1.11
    • /
    • 2023
  • Objectives: This study evaluated the dentinal penetration depth of 2.5% sodium hypochlorite (NaOCl) in root canals with and without preparation and different irrigant activation protocols. Materials and Methods: Sixty-three bovine mandibular incisors were randomly allocated to 6 groups (n = 10): G1, preparation + conventional needle irrigation (CNI); G2, preparation + passive ultrasonic irrigation (PUI); G3, preparation + Odous Clean (OC); G4, no preparation + CNI; G5, no preparation + PUI; G6, no preparation + OC; and CG (negative control; n = 3). Samples were filled with crystal violet for 72 hours. Irrigant activation was performed. Samples were sectioned perpendicularly along the long axis, 3 mm and 7 mm from the apex. Images of the root thirds of each block were captured with a stereomicroscope and analyzed with an image analysis software. One-way analysis of variance, followed by the Tukey post hoc test, and the Student's t-test were used for data analysis, with a significance level of 5%. Results: The NaOCl penetration depth was similar when preparation was performed, regardless of the method of irrigation activation (p > 0.05). In the groups without preparation, G6 showed greater NaOCl penetration depth (p < 0.05). The groups without preparation had a greater NaOCl penetration depth than those with preparation (p = 0.0019). Conclusions: The NaOCl penetration depth was similar in groups with root canal preparation. Without root canal preparation, OC allowed deeper NaOCl penetration. The groups without preparation had greater NaOCl penetration than those undergoing root canal preparation.

Impact of different agitation methods on smear layer cleaning of mesial canals with accentuated curvature

  • Abel Teves Cordova;Murilo Priori Alcalde;Michel Espinosa Klymus;Leonardo Rigoldi Bonjardim;Rodrigo Ricci Vivan;Marco Antonio Hungaro Duarte
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.2
    • /
    • pp.12.1-12.10
    • /
    • 2024
  • Objectives: This study evaluated the impact of different methods of irrigant agitation on smear layer removal in the apical third of curved mesial canals of 3 dimensionally (D) printed mandibular molars. Materials and Methods: Sixty 3D-printed mandibular second molars were used, presenting a 70° curvature and a Vertucci type II configuration in the mesial root. A round cavity was cut 2 mm from the apex using a trephine of 2 mm in diameter, 60 bovine dentin disks were made, and a smear layer was formed. The dentin disks had the adaptation checked in the apical third of the teeth with wax. The dentin disks were evaluated in environmental scanning electron microscope before and after the following irrigant agitation methods: G1(PIK Ultrasonic Tip), G2 (Passive Ultrasonic Irrigation with Irrisonic- PUI), G3 (Easy Clean), G4 (HBW Ultrasonic Tip), G5 (Ultramint X Ultrasonic tip), and G6 (conventional irrigation-CI) (n = 10). All groups were irrigated with 2.5% sodium hypochlorite and 17% ethylenediaminetetraacetic acid. Results: All dentin disks were 100% covered by the smear layer before treatment, and all groups significantly reduced the percentage of the smear layer after treatment. After the irrigation protocols, the Ultra-X group showed the lowest coverage percentage, statistically differing from the conventional, PIK, and HBW groups (p < 0.05). There was no significant difference among Ultramint X, PUI-Irrisonic, and Easy Clean (p > 0.05). None of the agitation methods could remove the smear layer altogether. Conclusions: Ultramint X resulted in the most significant number of completely clean specimens.

Damping Properties and Transmlission Loss of Polyurethane. II. PU Layer and Copolymer Effect

  • Yoon, kwan-Han;Kim, Ji-Gon;Bang, Dae-Suk
    • Fibers and Polymers
    • /
    • v.4 no.2
    • /
    • pp.49-53
    • /
    • 2003
  • Polyurethane (PU) layer and copolymer consisted of the different molecular weights (1000 and 2000 g/mol) of poly(propylene glycol) (PPG) were prepared. The damping and mechanical properties of these materials were compared with PU 1000 made by PPG having the molecular weight of 1000 g/mol. The optimum composition of PU2000 used for PU layer and copolymer was diphenylmethane diioscynate (MDI)/propylene glycol (PPG)/butanediol (BD) (1/0.3/0.7) based on the damping and mechanical properties. The damping peak of PU copolymer was higher than those of PU layer and PUI 1000 in low temperature range (-30- $10^{\circ}C$). For application in noise reduction, the transmission loss of the mechanical vibration through solid structure was measured. PU layer and copolymer were used as a damping layer. The transmission loss of PU copolymer was more effective than those of PU layer and PU 1000 in the experimental frequency range.

Realistic Interaction Technology for Virtual Reality (실감형 가상현실 상호작용 기술동향)

  • Kim, Y.W.;Jo, D.S.;Kim, Y.H.;Kim, H.M.;Kim, K.H.
    • Electronics and Telecommunications Trends
    • /
    • v.27 no.3
    • /
    • pp.62-72
    • /
    • 2012
  • IT 기술과 콘텐츠 기술이 융합된 가상현실 기술은 최근 산업, 의료, 엔터테인먼트, 교육, 문화 체험, 국방, 건축 등 적용이 널리 증가되고 있다. 본고에서는 실감형 가상현실 상호작용 기술의 동향과 활용 사례를 통하여, 핵심기술 요소와 시장 활용성 및 향후 응용 분야를 제시한다. 특히, Physical User Interface(PUI) 센서, depth 센서(혹은 RGB-D 센서) 등 3D 인터페이스를 통해 사용자의 위치 추적 및 사용자의 의도를 실시간으로 분석하고, 주변 환경에 대한 그래픽적인 표현 및 시각화에 의해 콘텐츠와 그래픽적인 표현 및 시각화에 의해 콘텐츠와 자연스럽게 상호작용하는 기법에 관한 동향을 중심으로 소개한다.

  • PDF