• Title/Summary/Keyword: PSCAD

Search Result 741, Processing Time 0.067 seconds

Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System (계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가)

  • Seol, Jae-Woong;Jang, Jae-Jung;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1687-1688
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic (PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that tan occur in the grid-connected PV system from aspect of power quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD). The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

Development of User-defined Components for Dynamic Test of Distance Relay Models Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 거리계전기 동특성 시험에 관한 컴포넌트 모델 개발)

  • Lee, Hong-Hak;Lee, Tae-Young;Kim, Ho-Pyo;Nho, Jang-Hyun;Kang, Kun-Soo;Jang, Sung-Hoon;Lee, Jae-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.242-244
    • /
    • 2003
  • The functional test of protection relays is divided into two kind of test types; the steady-state test and dynamic test. Because the steady-state test is comparatively easy, this test is used to test the characteristics of the relaying elements, operating values, resetting values and etc. using equipment such as Doble. But the dynamic test has to be performed on the test environment with RTDS(real time digital simulator) because of the dynamic characteristics of real protection relays. Therefore, it is not usually easy to perform dynamic test of relays using power system simulation tool based on PC(personal computer) such as PSCAD/EMTDC. This paper discusses how to develop and implement a test model and user-defined components that can be performed dynamic test using PSCAD/EMTDC.

  • PDF

Development of PSCAD Simulation Model for Doubly-fed Induction-type Wind Power Generation System (이중여자 유도형 풍력 발전기의 PSCAD 시뮬레이션 모델 개발)

  • Jeong, Byoung-Chang;Kim, Hee-Jung;Chung, Yong-Ho;Jeon, Young-Soo;Kwak, No-Hong;Song, Seung-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.261-264
    • /
    • 2006
  • In this paper, doubly-fed induction-type wind power generation system simulation model for grid connection is developed. The simulation model is based on PSCAD/EMTDC and consists of rotor-blade, blade controller, generator power converter and generator controller Blade controller controls the blade pitch angle for starting, peak power limiting and emergency condition. Generator controller controls the generator output power to maximize the system efficiency. Simulation results are shown for the variable wind speed conditions. The simulation model can be utilized for study of actual interaction between wind turbine and grid for reliable operation and protection of power system.

  • PDF

The Comparison of the Current Unblance Factor According to the Cable Array Method using PSCAD/EMTDC and FEA (PSCAD/EMTDC와 FEA를 이용한 케이블 배열 방법에 따른 전류 불균형률의 비교)

  • Shin, Ho-Jeon;Kim, Ji-Ho;Kang, Gab-Suk;Kim, Jae-Chul;Lee, Hyang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.2
    • /
    • pp.72-78
    • /
    • 2013
  • In this study, samples from the site where there occurred unbalanced current when cable routing were analyzed, and the simulation program for electric power system analysis, PSCAD/EMTDC, was used to calculate the current unbalance on cable routing. Based on electromagnetic finite element analysis(FEA), electromagnetic parameters enabled the interlocking with COMSOL for the calculation of allowable current ampacity and magnetic filed distribution. This then led to modeling unbalanced current between common modes using the unbalanced current analysis program, thereby comparing and discussing the results from both. The analyzed model is a common mode 2 parallel circuit, which is a basic model for cable routing, and by arranging cables in various ways, the arrangement with the least current unbalance was suggested, which would, in the future, prevent earth faults and extend life for the whole cable.

Analysis and Design for Simulator of Test Devices of New Energy Sources Based on the PSCAD/EMTDC (PSCAD/EMTDC에 의한 분산전원용 계통연계 시뮬레이터의 설계 및 분석)

  • Son, Jun-Ho;Park, Hyen-Seok;Kim, Chang-Hyeok;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.842-845
    • /
    • 2009
  • 본 연구에서는 신 에너지전원(태양광)이 배전계통에 연계되어 운용되는 것을 상정하여, 정상상태와 비상(사고)상태, 전력품질(순시), 스마트배전설비 등에 대한 배전계통의 특성 및 신 에너지전원의 특성을 시험하고 분석할 수 있는 분산전원용 계통연계 시뮬레이터를 제작하고 평가하기 위하여, 배전계통 전용해석 S/W인 PSCAD/EMTDC를 이용하여 사전 시뮬레이션을 수행하여 설계를 수행하고, 시험결과를 분석하였다. 본 연구에서 제작한 시뮬레이터는 배전용변전소(154/22.9KV)의 주변압기와 3상 4선식 22.9KV 고압배전선로의 2개 선로 및 부하를 축약형태(약 1/100)로 모의한 것이지만, 주상변압기(13,200/380/220V) 이하의 저압 배전선로는 실계통과 거의 동일한 상태로 모의한 것이다. 이상의 구성요소 데이터를 산출하기 위하여 PSCAD/EMTDC를 이용하여 사전 시뮬레이션을 수행하여 설계 및 제작을 수행하고 그 효용성을 확인하였다.

  • PDF

A Study on the Characteristics of New Frequency Controller According to Changing the Frequency Measurement Position of HVDC System (HVDC 시스템의 주파수 신호검출 위치 변경에 따른 새로운 주파수 제어기 특성 연구)

  • Kim Chan-Ki;Han Byoung-Sung;Park Jong-Kwang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.457-467
    • /
    • 2005
  • This paper deals with the new frequency controller of the HVDC scheme linking Haenam to Cheju Island. The primary aim of the study is to develop and evaluate a new frequency controller after the removing of the present synchronous compensators. The simulation methods are the mix of PSCAD/EMTDC and PSS/E, the main system studies are done for the transient state analysis using PSCAD/EMTDC. The study cases are completed involving 3 phase, single phase trip and load tripping events and study plots presented. In conclusion, the new frequency measurement from the AC network gives effective frequency control and dynamic performance.

A Study of the AC/DC Interconnected system Using the Cheju-Haenam HVDC PSCAD/EMTDC Model (PSCAD/EMTDC 제주-해남 HVDC(High-Voltage Direct Current)시스템 해석모델을 이용한 교직연계계통 분석)

  • Oh, Kwan-Il;Yoon, Jong-Su;Jeon, Young-Soo;Chang, Byung-Hoon;Lim, Sung-Joo;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.158-160
    • /
    • 2001
  • 본 논문은 PSCAD/EMTDC프로그램을 이용한 제주-해남 HVDC시스템의 해석모델 개발과 해석모델을 이용한 제주-해남 HVDC시스템의 운전특성에 대한 분석 내용을 기술하였다. 제주-해남 HVDC의 안정적인 운용을 위해서는 HVDC시스템의 이해와 함께 제주교류계통의 계통특성도 같이 고려되어야 한다. 이를 위해서는 제주-해남 HVDC와 제주교류계통을 포함하는 시뮬레이션 모델을 개발하여 다양한 상황에서의 시뮬레이션을 수행하여야 한다. 본 논문에서는 AC계통과 DC 계통의 상호작용에 의한 영향 분석과 교직연계계통의 계통운용 특성에 대해서 EMTDC 제주-해남 HVDC모델과 제주 AC계통 등가축약 모델을 이용하여 분석한 결과를 설명하였다. PSCAD/EMTDC는 EMTP와 더불어 전력시스템의 과도현상 해석을 위한 신뢰성 있는 프로그램이다.

  • PDF

Analysis on the Short Circuit Current of a Low Voltage Direct Current(DC) Distribution System using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 저전압 직류 배전 시스템의 단락 고장 전류 분석)

  • Ahn, Jae-Min;Jeon, Jeong-Chay;Lim, Young-Bae;Bae, Seok-Myeong;Byeon, Gil-Sung;Lee, Kyoung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.473-476
    • /
    • 2010
  • In this paper, we analyzed the short circuit current of a low voltage direct current distribution system. For the analysis, we performed the modeling of the low voltage direct current distribution system with a 6-pulse three-phase thyristor rectifier using the PSCAD/EMTDC, surveyed impedance of sources, transformers and distribution lines to run a simulation. A result of the simulation is that short circuit currents of the direct current distribution system with the rectifier decreased due to a thyristor-ON-resistance(Ron). But in case of the low thyristor-ON resistance, output fault current of the rectifier increased over three-phase short circuit current of an AC power system without a rectifier by regular ratio of the rectifier. Because the output fault current of the rectifier can increase over interrupting the capacity of circuit breakers, studying short circuit currents of a low voltage direct current distribution system with a rectifier is necessary for introducing the direct current distribution systems.

A study on the SMES component modeling using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 SMES Component modeling에 관한 연구)

  • Kim, Jin-Gun;Kim, Jae-Ho;Jung, Hee-Yeol;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1998-1999
    • /
    • 2007
  • Before applying the HTS(High Temperature Superconductor) power devices to a real utility network, system analysis should be carried out by some simulation tools. PSCAD/EMTDC simulation tool is one of the most popularized useful analysis tools for electrical power system. Unfortunately the model component for HTS coil is not provided in PSCAD/EMTDC simulation tool. In this paper, EMTDC model component for HTS coil has been developed considering real characteristics of HTS coil like critical current, temperature and magnetic field. The developed model component of HTS coil could be used for power system application. Using the developed model component for HTS coil, we can easily do the simulation of HTS power devices application test in utility with the various inductance, quench current, inner magnetic field, and temperature values, for instances; SMES(Superconducting Magnetic Energy Storage) system, superconducting motor, transformer, and FCL(Fault Current Limiter)

  • PDF

Time domain Simulation of a Secondary Voltage Regulation Model to the Jeju Power System (제주 전력계통 2차 전압제어 모델 구축 및 시모의)

  • Yang, Byeong-Mo;Song, In-Jun;Kim, Yong-Hak;Kwark, No-Hong;Kang, Ji-Won;Jang, Tae-In;Song, Hwa-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.469-470
    • /
    • 2007
  • There are many power system simulation software tools for time-domain performance in power system. This paper reports the results of time-domain simulation for the Jeju Power system with a secondary voltage regulation (SVR) model, developed with both TSAT and PSCAD/EMTDC and evaluates them, which are commercial software tools used for digital simulation of power system. TSAT has not been yet verified because of deficient modelling of components in the time domain performance of KEPCO power system. But PSCAD/EMTDC has been enough verified in our system. So, we need to compare and evaluate TSAT with PSCAD/EMTDC in small power system like Jeju. This paper showed that the results simulated by both TSAT and PSCAD/EMTDC is very similar to each other, so TSAT is able to apply for our KEPCO large power system.

  • PDF