• Title/Summary/Keyword: PMMA(Polymethyl methacrylate)

Search Result 159, Processing Time 0.025 seconds

Electric and Electrochemical Characteristic of PMMA-PEO Gel Electrolyte for Rechargeable Lithium Battery

  • 박수길;박종은;이홍기;이주성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.768-772
    • /
    • 1998
  • The new type polymer electrolyte composed of polymethyl methacrylate(PMMA) - polyethy leneoxide(PEO) contain $LiClO_4$ -EC/PC was developed for the weightless and long or life time of lithium polymer batery system with using polyaniline electrode. the gel type electrolytes were prepared by PMMA with PEO at different lithium salts in the glove box. The minimum thickness of PMMA-PEO gel electrolyte for the slim type is about(400~450$\mu\textrm{m}$. These gel electrolyte showed good compatibility with lithium electrode. The test cell Li/polymer electrolyte/polyaniline solid state cell which was prepared by different lithium salt was researched by electrochemical technique.

  • PDF

Dielectric Characteristics of PMMA-Ni-PZT Composite (PMMA-Ni-PZT 복합체의 유전 특성)

  • Jung, Won-Chae;Lee, Hee-Young;Kim, Jeong-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.343-343
    • /
    • 2006
  • 집적회로기판의 소형화 추세에 따라 커패시터, 인덕터, 저항과 같은 수동소자를 PCB 기판내부에 임베딩하는 연구가 국내외에서 활발하게 진행되고 있다. 본 논문에서는 polymer-metal-ceramic의 3상 복합체 구조를 가지는 임베디드 커패시터에서 Bimodal PZT분말에 따른 유전 특성에 대하여 고찰하였다. 매트릭스를 형성하는 고분자 재료로는 PMMA(polymethyl methacrylate)를 사용하였으며, 충분히 혼합된 분말을 고온에서 프레싱하여 시편을 제조하였다. 유전특성은 임피던스분석기 및 LCZ 미터를 이용하여 측정하였으며, 실험결과는 혼합법칙과 Percolation 이론을 이용하여 해석하였다.

  • PDF

Influence of Loading Position and Reaction Gas on Etching Characteristics of PMMA in a Remote Plasma System (Remote 플라즈마에서 위치 및 반응기체에 따른 PMMA의 식각 특성 분석)

  • Ko, Cheonkwang;Lee, Wongyu
    • Korean Chemical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.483-488
    • /
    • 2006
  • Etching process of PMMA (Polymethyl Methacrylate) on glass surface was investigated by dry etching technique using remote plasma. To determine the etching characteristics, the remote plasma etching was conducted for various process parameters such as plasma power, reaction gas and distance from plasma generation. As the distance from the plasma generation was increased, the etch rate of PMMA was linearly decreased by radical density in plasma. PMMA has removed by reactive radicals in the plasma. The etch rate increased with plasma power because of more reactive radicals. The etch rate and surface roughness of PMMA increased with $O_2$ concentration in the etchant.

A Study on the Resolution Analysis of Digital X-ray Images with increasing Thickness of PMMA (조직 등가물질 두께 증가에 따른 디지털 엑스선 영상의 해상도 분석에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • Scattered x-ray generated by digital radiography systems also have the advantage of increasing signals, but ultimately detectability is reduced by decreasing resolution and increasing noise of x-ray images transmitted objects. An indirect method of measuring scattered x-ray in a modulation-transfer function (MTF) for evaluating resolution in a spatial-frequency domain can be considered as a drop in the MTF value corresponding to zero-frequency. In this study, polymethyl methacrylate (PMMA) was used as a patient tissue equivalent, and MTFs were obtained for various thicknesses to quantify the effect of scattered x-ray on resolution. X-ray image signals were observed to decrease by 35 ~ 83% with PMMA thickness increasing, which is determined by the absorption or scattering of x-rays in PMMA, resulting in reduced MTF and increased scatter fraction. The method to compensate for MTF degradation by PMMA resulted in the MTF inflation without considering the optical spreading generated by the indirect-conversion type detector. Data fitting or zero-padding are needed to compensate for MTF more reasonably on edge-spread function or line-spread function.

Percutaneous Vertebroplasty in the Treatment of Vertebral Body Compression Fracture with Osteoporosis - Preliminary Report - (골다공증을 동반한 척추체 압박골절에 대한 경피적 척추 성형술 - 예비보고 -)

  • Lee, Sang-Gu;Yoo, Chan-Jong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.5
    • /
    • pp.615-622
    • /
    • 2000
  • Objective : Percutaneous vertebroplasty is an effective and minimally invasive procedure consisting of the injection of a PMMA(polymethyl methacrylate) into the vertebral body compression fracture with osteoporosis. Matherials and Methods : Twenty-eight procedures were performed for vertebral body compression fractures with osteoporosis in 25 patients(22 women, 3 men). The mean age was 65.9 years old. The inclusion criteria for percutaneous vertebroplasty were 1) acute vertebral body compression fracture with osteoporosis, 2) expected high operative morbidity in old age, 3) no neurologic deficits, 4) no or minimal canal enchroachment, 5) patient refusal of invasive surgery. All patients underwent MR images before the procedure. Under local anesthesia, after the percutaneous needle puncture of the involved vertebra via a transpedicular approach and venography using the water soluble contrast material, PMMA injection was introduced into the fractured vertebral body. Results : The procedure was technically successful in all patients. All patients experienced excellent pain relief (complete pain relief ; 10, marked pain relief ; 14). One patient experienced marked pain relief, however, the patient died during the follow-up period due to stomach cancer. There were twelve paravertebral tissue leaks, twelve paravertebral venous plexus leaks, four epidural leaks and one intradiskal leak, but no clinically significant complications occurred in all patients. Conclusion : Percutaneous vertebraoplasty is a valuable procedure in the treatment of vertebral body compression fracture with osteoporosis, providing immediate pain relief and early mobilization. MRI is the most reliable diagnostic tool for identifying painful fractured vertebral body.

  • PDF

Manufacturing of Flexible Patterned Cover Film for Solar Cell by Solution Coating (용액 코팅을 이용한 태양전지용 고분자 유연 패턴필름 제조)

  • Park, Chanwook;Kang, Ho-Jong
    • Polymer(Korea)
    • /
    • v.37 no.5
    • /
    • pp.656-662
    • /
    • 2013
  • The flexible patterned cover film was made by a simple solution coating process using polymethyl methacrylate (PMMA) solution with glass beads. The effect of patterned cover film on the efficiency of solar cell has been investigated. It was found that the relative solar cell efficiency increased up to 3.4% with the incident light angle between $0-90^{\circ}$ by the sphere shape of glass bead coated on the film surface. This was understood that the loss of transmittance and scattering due to the light directional dependency on solar cell were minimized because the light entered glass beads normal to its surface regardless of incident light angle. The maximum relative solar cell efficiency was achieved when glass bead shape on the film is hemisphere and the relative efficiency increased with increasing the amount of glass bead on the film surface. However, too much glass beads on the film surface resulted in the lower relative solar cell efficiency due to the lowering of transmittance as well as the occurring of light interference.

Effect of polymerization temperature on the mechanical properties of provisional prosthesis resins (중합 온도가 임시 보철용 수지의 기계적 성질에 미치는 영향)

  • Hong, Min-Ho;Ha, Jung-Yun;Kwon, Tae-Yub
    • Korean Journal of Dental Materials
    • /
    • v.44 no.4
    • /
    • pp.311-318
    • /
    • 2017
  • The purpose of this study was to examine the effects of the curing sequence and polymerization temperature on the flexural strength and microhardness of two provisional resins (Bis-acryl resin composite and polymethyl methacrylate (PMMA)). Polymerization was carried out under various conditions, in air at $25^{\circ}C$ (control) and in hot water (40, 50, 60, 70, and $80^{\circ}C$). The flexural strength test was conducted according to ISO-4049. The Knoop hardness was measured. For the Bis-acryl resin, the temperature up to $50^{\circ}C$ did not increase the flexural strength nor the hardness of the bis-acryl resin composite (p>0.05) but higher temperatures increased the strengths. For the PMMA resin, flexural strength increased with temperatures up to $70^{\circ}C$ and then decreased slightly. Bis-acryl resin composite had higher mechanical properties than the PMMA resin. The effect of heat was more pronounced in the bis-acryl resin composite than in the PMMA resin (p<0.05).

Evaluation of Physical Properties of Resin Containing Zinc Nanoparticle. (아연나노입자함유 교정용 레진의 물리적 특성 평가)

  • Jo, Jeong-Ki
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.373-379
    • /
    • 2019
  • Polymethyl methacrylate (PMMA), a self-polymerizing resin for removable orthodontic devices, has been used as a dental orthodontic device for many years because of its advantages such as color stability, volume stability, and tissue compatibility. However, such a removable orthodontic device has a disadvantage that the longer the use in the oral cavity due to the low strength of the PMMA fracture of the orthodontic device resin in use. In this study, zinc nanoparticles (ZNP) were mixed with orthodontic PMMA to introduce strength effect. Rectangular samples ($1.4{\times}3.0{\times}19.0mm$) of orthodontic PMMA (0, 0.5, 1.0, 2.0 and 4.0%) containing ZNP were prepared. The finished specimen was tested for three-point bending strength at a speed of 1 mm / min, and the Vickers hardness was measured three times using a hardness tester. The surface roughness was measured with a surface roughness. As a result, the 3-point bending strength did not change significantly (p>0.05). Surface energy increased significantly. As a result, we successfully synthesized ZNP in this study and prepared the dispersed resin specimen for calibration. It will be possible to develop high-density dental orthodontic resins.

Optimization Study of Digital X-ray Imaging with Dual Energy Subtraction Method (듀얼 에너지 감산기법을 이용한 디지털 X-ray 영상 최적화에 관한 연구)

  • Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.138-142
    • /
    • 2016
  • Dual-energy digital radiography (DEDR) has been used for detecting lesions within the body using energy subtraction methods. The purpose of this study was to acquire optimal bone and tissue image by changing physical factors such as Tube voltage (kVp) and add filters, and then we compared with the predicted values using SRS-78 program and experimental results. For that purpose, we acquired images according to changes in physical parameters of various materials since we had to acquire the optimal bone and tissue image using energy subtraction. Used phantom consists of aluminum and polymethyl methacrylate (PMMA) and a comparison of image optimization was measured by contrast-to-noise ratio (CNR). In results, first of all, we confirmed that a subtraction image from 50 kVp image and 120 kVp image is optimal bone and tissue image. Also when we added a 10 mm Aluminum add filter, we expected it is a result of the optimal bone and tissue image. Besides, we confirmed these results are consistent with the predicted optimized condition by SRS-78 program.. In conclusion, we indicated that we can acquire optimal bone and tissue image by controling physical factors such as kVp, add filters through this study. Also we expected that DEDR will contribute to the field of medical imaging technology.

Nanometer-Scale Surface Analysis of Polymers Using Laser Ablation Spectroscopy (레이저 애벌레이션 분광을 이용한 고분자 표면의 나노미터 스케일 표면 분석)

  • Kim, Min-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1334-1336
    • /
    • 2001
  • In this study, laser ablation atomic fluorescence (LAAF) spectroscopy has been applied for a nanometer-scale surface analysis of Na-doped polymethyl methacrylate (PMMA). LAAF spectroscopy is a new sensitive element detection technique which involves atomizing of a sample by the laser ablation and detection of ablated plume by laser-induced fluorescence (LIF) spectroscopy. Using this technique in the detection of Na atoms with Na-doped PMMA, a detection limit is obtained as 36 fg for single laser shot. Further, the depth distribution in the sample is measured with a very high spatial resolution using a two-layer PMMA sample by observing the shot-by-shot LIF intensity from the Na atoms.

  • PDF