A Study on the Resolution Analysis of Digital X-ray Images with increasing Thickness of PMMA  

Kim, Junwoo (Center for Advanced Medical Engineering Research, Pusan National University)
Publication Information
Journal of the Korean Society of Radiology / v.15, no.2, 2021 , pp. 173-179 More about this Journal
Abstract
Scattered x-ray generated by digital radiography systems also have the advantage of increasing signals, but ultimately detectability is reduced by decreasing resolution and increasing noise of x-ray images transmitted objects. An indirect method of measuring scattered x-ray in a modulation-transfer function (MTF) for evaluating resolution in a spatial-frequency domain can be considered as a drop in the MTF value corresponding to zero-frequency. In this study, polymethyl methacrylate (PMMA) was used as a patient tissue equivalent, and MTFs were obtained for various thicknesses to quantify the effect of scattered x-ray on resolution. X-ray image signals were observed to decrease by 35 ~ 83% with PMMA thickness increasing, which is determined by the absorption or scattering of x-rays in PMMA, resulting in reduced MTF and increased scatter fraction. The method to compensate for MTF degradation by PMMA resulted in the MTF inflation without considering the optical spreading generated by the indirect-conversion type detector. Data fitting or zero-padding are needed to compensate for MTF more reasonably on edge-spread function or line-spread function.
Keywords
PMMA; Scattered X-ray; MTF;
Citations & Related Records
연도 인용수 순위
  • Reference
1 H. K. Kim, M. K. Cho, T. Achterkirchen and W. Lee, "Radiation Effects on the Performance of CMOS Photodiode Array Detectors and the Role of Gain-Offset Corrections", IEEE Transactions on Nuclear Science, Vol. 56, No. 3, pp. 1179-1183, 2009. http://dx.doi.org/10.1109/TNS.2009.2014232   DOI
2 J. W. Coltman, "The Specification of Imaging Properties by Response to a Sine Wave Input", Journal of the Optical Society of America, Vol. 44, No. 6, pp. 468-471, 1954. http://dx.doi.org/10.1364/JOSA.44.000468   DOI
3 H. P. Chan, K. Doi, "Investigation of the performance of antiscatter grids: Monte Carlo simulation studies", Physics in Medicine & Biology, Vol. 27, No. 6, pp. 785-803, 1982. http://dx.doi.org/10.1088/0031-9155/27/6/002   DOI
4 M. Sandborg, D. R. Dance, G. A. Carlsson, J. Persliden, M. J. Tapiovaara, "A Monte Carlo study of grid performance in diagnostic radiology: task-dependent optimization for digital imaging", Physics in Medicine & Biology, Vol. 67, No. 793, pp. 1659-1676, 1994. http://dx.doi.org/10.1088/0031-9155/39/10/010   DOI
5 E. Shaheen, F. Zanca, F. Sisini, G. Zhang, J. Jacobs, and H. Bosmans, "Simulation of 3D objects into breast tomosynthesis images", Radiation Protection Dosimetry, Vol. 139, No. 1-3, pp. 108-112, 2010 https://doi.org/10.1093/rpd/ncq084   DOI
6 G. T. Barnes, "Contrast and scatter in x-ray imaging", Radiographics, Vol. 11, No. 2, pp. 307-323, 1991. https://doi.org/10.1148/radiographics.11.2.2028065   DOI
7 A. K. Carton, H. Bosmans, C. Van Ongeval, G. Souverijns, F. Rogge, A. Van Steen, and G. Marchal, "Development and validation of a simulation procedure to study the visibility of micro calcifications in digital mammograms", Medical Physics, Vol. 30, No. 8, pp. 2234-2240, 2003. https://doi.org/10.1118/1.1591193   DOI
8 G. Wu, J. G. Mainprize, J. M. Boone, and M. J. Yaffe, "Evaluation of scatter effects on image quality for breast tomosynthesis", Medical Physics, Vol. 36, No. 10, pp. 4425-4432, 2009. https://doi.org/10.1118/1.3215926   DOI
9 E. Samei, M. J. Flynn, D. A. Reimann, "A method for measuring the presampled MTF of digital radiographic systems using an edge test device", Medical Physics, Vol. 25, No. 1, pp. 102-113, 1998. https://doi.org/10.1118/1.598165   DOI
10 J. M. Boone, J. A. Seibert, "Monte Carlo simulation of the scattered radiation distribution in diagnostic radiology", Medical Physics, Vol. 15, No. 5, pp. 713-720, 1988. https://doi.org/10.1118/1.596185   DOI
11 S. N. Friedman and I. A. Cunningham, "Normalization of the modulation trasnfer function: the open-field approach", Medical Physics, Vol. 35, No. 10, pp. 4443-4449, 2008. https://doi.org/10.1118/1.2977536   DOI
12 A. L. C. Kwan, J. A. Seibert, J. M. Boone, "An improved method for flat-field correction of flat panel x-ray detector", Medical Physics, Vol. 33, No. 2, pp. 391-393, 2006. https://doi.org/10.1118/1.2163388   DOI