• Title/Summary/Keyword: PM32

Search Result 3,771, Processing Time 0.045 seconds

Monitoring the Sugar Content and Intake in School Meals from Incheon and Chuncheon (인천, 춘천 지역 학교급식 메뉴의 당 함량 및 당 섭취량 실태조사)

  • Kim, Hee-Yun;Park, Se-Jong;Chung, So-Young;Choi, Seon-Hee;Oh, Sun-Woo;Lee, Jin-Sook;Choi, In-Sun;Shin, Min-Su;Song, Jae-Sang
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.58-64
    • /
    • 2011
  • The purpose of this study was to analyze the content and consumption of total sugar from school lunches at Incheon and Chuncheon. The samples were collected from eight elementary schools and eight middle schools in Incheon and Chuncheon for 15 days. The analysis of total sugar content was performed for 1334 main dishes, side dishes, and desserts, which were supplied by elementary and middle school foodservices. Total sugar content was extracted from various types of food with 50% ethanol after defatting. We simultaneously analyzed sugars such as fructose, glucose, sucrose, maltose, and lactose by a high performance liquid chromatography with refractive index detector. The average lunch intake for elementary school and middle school students was $372.6{\pm}72.2g$ and $449.2{\pm}81.1g$, respectively. The total sugar content in desserts was $7.21{\pm}6.32g/100g$, $1.69{\pm}2.44g/100g$ in side dishes, and $0.32{\pm}0.77g/100g$ in main dishes. Among side dishes, fried foods, stir-fried foods, and sauces contained the highest amounts of total sugar. The total sugar intake was $4.63{\pm}5.11g$ in desserts, $0.64{\pm}1.01g$ in side dishes, and $0.55{\pm}1.48g$ in main dishes. Main and side dishes with a high total sugar intake included cooked rice with seasoning, fried foods, stir-fried foods, and preserved foods. The average total sugar intake per meal for elementary school, middle school, and all students was $4.03{\pm}3.67g$, $6.97{\pm}6.59g$, and $5.50{\pm}5.53g$, respectively. We have provided useful information to decrease the intake of total sugar in school lunches. It is recommended that total sugar intake be continuously monitored.

Immediate Effect of Cigarette Smoking on Exercise (흡연이 운동에 미치는 단기 효과)

  • Choe, Kang-Hyeon;Choi, Cheol-Jun;Kim, Yong-Tae;Lim, Chae-Man;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.6
    • /
    • pp.511-516
    • /
    • 1992
  • Background: It is well known that cigarette smoking is the risk factor of lung cancer, chronic obstructive pulmonary disease and ischemic heart disease. But there are few reports about the immediate effect of cigarette smoking on the cardiopulmonary functions. The serum level of carbon monoxide increases during cigarette smoking. It is known that carbon monoxide increases respration rate, heart rate and cardiac output, with decrease in maximal oxygen consumption. So we have studied to determine the immediate effects of cigarette smoking on the cardiopulmonary function during exercise. Method: Thirteen healthy smoking male subjects were included in this study. Each subject was undertaken pulmonary function test and incremental exercise test on two separate days, one without smoking (control) and the other after smoking three cigarettes per hour for five hours. The order of the two tests was randomized. Results: 1) The mean age of the subjects was $25{\pm}4.9$ year-old and the mean smoking history was $6{\pm}5$ pack years. 2) The mean blood level of carbon monoxide on the smoking day was higher than that on the nonsmoking day ($5.97{\pm}1.34%$ vs. $1.45{\pm}0.83%$; p<0.01). 3) The mean maximal oxygen consumption on the smoking day was lower than that on the nonsmoking day ($2.09{\pm}0.32$ L/min vs. $2.39{\pm}0.32$ L/min; p<0.05). 4) The mean anaerobic threshold on the smoking day was lower than that on the nonsmoking day ($1.33{\pm}0.24$ L/min vs. $1.53{\pm}0.20$ L/min; p<0.05). 5) The mean heart rate at rest on the smoking day was higher than that on nonsmoking day ($84.38{\pm}11.06$ beats/min vs. $75.46{\pm}5.83$ beats/min; p<0.05). But the means of maximal heart rate on both days were not different. 6) The pulmonary function tests were similar on both days. Conclusion: There was no change in pulmonary function test, but the maximal oxygen consumption and anaerobic threshold were decreased on the smoking day. So it was concluded that cigarette smoking impaired the cardiovascular functions immediately during exercise.

  • PDF

Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map (서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발)

  • Lee, Eun-Sun;Park, Min-Bin;Lee, Tae-Jung;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

Usefulness of a Functional Tracheobronchial Phantom for Interventional Procedure (중재 시술용 기능성 기관-기관지 팬텀의 유용성)

  • Kim, Tae-Hyung;Lim, Cheong-Hwan;Kim, Jeong-Koo;Kim, Myeong-Soo;Choi, Won-Chan;Lim, Jin-Oh;Lee, Kwang-Jong;Park, In-Ae;Kim, Mi-Ok;Jung, Eun-Mi;Shin, Ryung-Mi;Jung, Seung-Ki;Youn, Sun-Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.27-32
    • /
    • 2003
  • To evaluate usefulness of a functional tracheobronchial phantom for interventional procedure. The functional phantom was made as a actual size with human normal anatomy used silicone and a paper clay mold. A tracheobronchial-shape clay mold was placed inside a square box and liquid silicone was poured. After the silicone was formed, the clay was removed. We measured film density and tracheobronchial angle at the human, animal and phantom, respectively. The film density of trachea part were 0.76(${\pm}0.011$) in human, 0.97(${\pm}0.015$) in animal, 0.45(${\pm}0.016$) in phantom. The tracheobronchial bifurcation part measured 0.51(${\pm}0.006$) in human, 0.65(${\pm}0.005$) in animal, 0.65(${\pm}0.008$) in phantom. The right bronchus part measured 0.14(${\pm}0.008$) in human, 0.59(${\pm}0.014$) in animal and 0.04(${\pm}0.007$) in phantom. The left bronchus were 0.54(${\pm}0.004$) in human, 0.54(${\pm}0.008$) in animal and 0.08(${\pm}0.008$) in phantom. At the stent part were 0.54(${\pm}0.004$) in human, 0.59(${\pm}0.011$) in animal and 0.04(${\pm}0.007$) in phantom, respectively. The tracheobronchial angle of the left bronchus site were $42.6({\pm}2.07)^{\circ}$ in human, $43.4({\pm}2.40)^{\circ}$ in animal and $35({\pm}2.00)^{\circ}$ in phantom, respectively. The right bronchus site were $32.8({\pm}2.77)^{\circ}$ in human, $34.6({\pm}1.94)^{\circ}$ in animal and $50.2({\pm}1.30)^{\circ}$ in phantom, respectively. The phantom was useful for in-vitro testing of tracheobronchial interventional procedure, since it was easy to reproduce.

  • PDF

차세대 위성용 탑재컴퓨터 설계

  • Kwon, Ki-Ho;Kim, Day-Young;Choi, Seung-Woon;Lee, Yun-Ki;Lee, Jong-In;Kim, Hak-Jung
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.79-87
    • /
    • 2005
  • This paper describes a new on-board computer design for the next generation satellite. The new on-board computer utilizes centralized processing architecture with MCMERC325C CPU based on functional modular design concepts. The on-board computer consists of PM32 Module, TC-TM Module, IO Module and Power module. The IEEE-1355 DS/DE, or SpaceWire, provides a standard communication interface between module. It also provides simple cross-strap design for redundancy management and increases re-usability of the modules.

  • PDF

Digital Infrared Thermographic Imaging(DITI) analysis by micro-magnetic stimulation for muscle fatigue recovery and muscle pain control (근피로 회복 및 근통증 완화를 위한 미약 자기장 자극에 대한 체열변화 분석)

  • Kim, Soo-Byung;Lee, Na-Ra;Lee, Seung-Wook;Lee, Kyong-Joung;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.7
    • /
    • pp.1653-1660
    • /
    • 2010
  • In this study, change of body surface temperature was measured using Digital Infrared Thermographic Imaging(DITI) to check muscle fatigue recovery & muscle pain control by magnetic stimulations. For clinical trials, subjects were divided into 3 groups : non stimulation group(NSG), electrical stimulation group(ESG) and micro magnetic stimulation group(MSG). In result, temperature differences between left and right arm surfaces were measured as much as $0.86{\pm}0.43^{\circ}C$(n=96) after the exercise, $0.78{\pm}0.12^{\circ}C$ after the electrical stimulation and $0.1{\pm}0.39^{\circ}C$ after the micro magnetic stimulation. Also after 3days, temperature differences between left and right arm surfaces were measured as much as $0.3{\pm}0.14^{\circ}C$ in the NSG, $0.05{\pm}0.21^{\circ}C$ in the ESG and $0.03{\pm}0.21^{\circ}C$ in the MSG. These data showed that the lowest temperature difference between left/right body surface was measured in MSG.

Reproductive Characteristic of Transgenic Massachusetts General Hospital Miniature Pigs for Xenotransplantation (Massachusetts General Hospital 미니돼지 유래 이종이식용 형질전환 돼지의 번식 특성 분석)

  • Ji, Soo-Jeong;Lee, Gunsup;Park, Sang Hyoun;Kim, Kyung Woon;Byun, Sung-June;Ock, Sun A;Hwang, Seongsoo;Woo, Jae-Seok;Oh, Keon Bong
    • Journal of Embryo Transfer
    • /
    • v.32 no.3
    • /
    • pp.165-170
    • /
    • 2017
  • Pigs have been extensively used as mediators of xenotransplantation research. Specifically, the Massachusetts General Hospital (MGH) miniature pig was developed to fix major histocompatibility antigens for use in xenotransplantation studies. We generated transgenic pigs for xenotransplantation using MGH pigs. However, it has not been studied yet whether these pigs show similarity of reproductive physiological characteristics to wild types of MGH miniature pig. In this study we analyzed the estrous cycles and pregnancy characteristics of wild type (WT) and transgenic MGH miniature pigs, which were ${\alpha}1,3$-galactosyltransferase (GalT) heterozygous and homozygous knock-out, and membrane cofactor protein (MCP) inserted in its locus, $GalT^{-MCP/+}$ and $GalT^{-MCP/-MCP}$ pigs. Estrous cycles of WT, $GalT^{-MCP/+}$ and $GalT^{-MCP/-MCP}$ pigs were $20.9{\pm}0.74$, $20.1{\pm}1.26$, and $17.3{\pm}0.87days$, respectively, and periods of estrous were $3.2{\pm}0.10$, $3.1{\pm}0.12$, and $3.1{\pm}0.11days$. The periods of gestation of WT, $GalT^{-MCP/+}$ and $GalT^{-MCP/-MCP}$ pigs were $114.2{\pm}0.37$, $113.3{\pm}0.67$, and $115.4{\pm}0.51days$, respectively. Litter sizes of WT, $GalT^{-MCP/+}$ and $GalT^{-MCP/-MCP}$ pigs were $4.8{\pm}0.35$, $4.8{\pm}1.11$ and $3.0{\pm}0.32$ respectively. There were no significant differences on estrous cycle, periods of estrous and gestation, and litter size among WT, $GalT^{-MCP/+}$ and $GalT^{-MCP/-MCP}$ pigs, meaning that GalT knock-out and additional expression MCP of the MGH miniature pig did not effect on reproduction traits. These results provide relevant information to establish breeding system for MGH transgenic pig, and for propagation of $GalT^{-MCP/-MCP}$ pig to supply for xenotransplantation research.

Comparison of Litter Production and Nutrient returned to Forest Floor according to Forest Fire Type and Recovery (산불유형과 회복정도에 따른 낙엽생산량과 임상으로 이입되는 영양염류 함량)

  • Kim, Jung-Sup;Yang, Keum-Chul
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • This study has compared the different types of forest fire sites and the unburned site at Samcheuk-si Gangwon-do by assessing the amount of litter production, nutrient concentration returned to forest floor from July 2007 through October 2010. The research showed that the average amounts of litterfall produced in the unburned site, the crown fire site(C-1), the crown fire site(C-3) and the ground fire site(G-2) were $7.74{\pm}2.56$, $1.17{\pm}0.67$, $2.97{\pm}0.44$ and $2.92{\pm}0.42ton{\cdot}ha^{-1}{\cdot}yr^{-1}$, respectively. In the unburned site, the average amounts of total nitogen(T-N), total phosphorus(T-P), potassium(K), calcium(Ca) and magnesium(Mg) returned to the forest floor were $22.20{\pm}12.43$, $1.16{\pm}0.46$, $2.68{\pm}1.44$, $16.22{\pm}4.69$ and $1.36{\pm}0.32 kg{\cdot}ha^{-1}{\cdot}yr^{-1}$, respectively whereas those in the crown fire site(C-1) were $3.73{\pm}2.31$, $0.10{\pm}0.09$, $0.27{\pm}0.20$, $2.75{\pm}2.58$ and $0.24{\pm}0.27 kg{\cdot}ha^{-1}{\cdot}yr^{-1}$, respectively. This study showed that the nutrient content returned to forest floor was higher in the following order: unburned site(Un) > crown fire site(C-3) > ground fire site(G-2) > crown fire site(C-1).

The Assessment of the Breath Hold and the Free Breath Methods about the Blood Flow Evaluation by Using Phase Contrast MRI (위상대조도 자기공명영상을 이용한 심장 혈류평가에 있어서 호흡정지 기법과 비 호흡정지 기법의 비교평가)

  • Kim, Seong-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.149-156
    • /
    • 2016
  • Measurement of cardiac blood flow using the magnetic resonance imaging has been limited due to breathing and involuntary movements of the heart. The present study attempted to improve the accuracy of cardiac blood flow testing through phase contrast magnetic resonance imaging by presenting the adequate breathing method and imaging variables by comparing the measurement values of cardiac blood flow. Each was evaluated by comparing the breath hold retrospective 1NEX and non breath hold retrospective 1-3NEX in the ascending aorta and descending aorta. As a result, the average blood flow amount/velocity of the breath hold retrosepctive 1NEX method in the ascending aorta were $96.17{\pm}19.12ml/sec$, $17.04{\pm}4.12cm/sec$ respectively, which demonstrates a statistically significant difference(p<0.05) with the non-breath hold retrospective method 1NEX of $72.31{\pm}13.27ml$ and $12.32{\pm}3.85$. On the other hand, the average 2NEX blood flow and mean flow velocity is $101.90{\pm}24.09$, $16.84{\pm}4.32$, 3NEX $103.06{\pm}25.49$, $16.88{\pm}4.19$ did not show statistically significant differences(p>0.05).The average blood flow amount/ velocity of the breath hold retrospective 1NEX method in the descending aorta were $76.68{\pm}19.72ml/s$, and $22.23{\pm}4.8$, which did not demonstrate a significant difference in comparison to non-breath hold retrospective method 1-3 NEX. Therefore, the non breath hold retrospective method does not significantly differ in terms of cardiac blood flow in comparison with the breath hold retrospective method in accordance with the increase of NEX, so pediatric patients or patients who are not able to breathe well must have the diagnostic value of their cardiac blood flow tests improved.

Analysis of Membrane Integrity, DNA Fragmentation and Mitochondrial Function in Pig Spermatozoa Sorted by Flowcytometer

  • Kim, In-Cheul;Han, Deug-Woo;Lee, Sung-Won;Ryu, Jae-Weon;Choi, Eun-Ji;Son, Jung-Ho
    • Reproductive and Developmental Biology
    • /
    • v.32 no.2
    • /
    • pp.123-126
    • /
    • 2008
  • The objective of this study was to determine the potential hazardous effects of sorting process by flowcytometry on the quality of boar spermatozoa by flowcytometer. Freshly collected boar semen was diluted and divided into two groups; control none sorted and sorted. Sperms in sorted group were processed with flowcytometer for cell sorting with $100\;{\mu}M$ nozzle under the 20 psi pressure. Measurements on each parameter were made at two time points, 0hr (right after sorting) and 24 hr post sorting. Although there was a tendency of lower viability in sorted group than none sorted control group, the percentage of live cells in control ($75.83{\pm}6.92\;&\;59.53{\pm}10.34$) was not significantly different from sorted ($59.70{\pm}7.37\;&\;43.97{\pm}3.76$) at both 0 and 24 hr post sorting. However, sorted sperm showed significantly lower mitochondrial function compared to the control at both 0 h ($79.37{\pm}3.22\;vs.\;63.50{\pm}10.05$) and 24 hr ($67.27{\pm}3.22$ vs. $46.97{\pm}5.37$) time points (p<0.007). Sperm DNA fragmentation rate was significantly lower in control ($22.0{\pm}7.04$) than that of sorted ($32.27{\pm}7.49$) at 24 hr time point (p<0.0002). Taken together, these data suggested thatsorting process by flowcytometer may have influenced sperm motility rather than viability. Also high speed sperm sorting by flowcytometer has significant effects on DNA fragmentation on elapsed time after sorting.