• Title/Summary/Keyword: PLGA

Search Result 282, Processing Time 0.026 seconds

EFFECT OF DIFFERENT STERILIZATION METHODS ON THE SURFACE MORPHOLOGY OF PPDO-hybrid-PLGA NANOFIBER SCAFFOLD AND ATTACHMENTS OF PC12 CELL (다양한 소독방법이 PPDO-hybrid-PLGA nanofiber scaffold의 형태와 세포부착에 미치는 영향에 관한 연구)

  • Lee, Ju-Hyon;Min, Hyun-Gi;Jung, Ju-Young;Kang, Na-Ra
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.6
    • /
    • pp.635-639
    • /
    • 2008
  • Objectives : the effect of different sterilization methods on the surface morphology of PPDO-hybrid-PLGA nanofiber scaffold and attachments of PC12 cell were investigated. Methods : Poly (p-dioxone)-hybrid-Poly (lactide-glycolide) (PPDO-hybrid-PLGA) nanofiber scaffold, fabricated in a tube form with 1.5 mm internal diameter, 0.2 mm thickness and 5 mm length, was prepared using electrospinning method. To study the surface morphology using SEM, The study group and control group in respective were; Control:Non-sterilized scaffold, Group I:scaffold sterilized with 70% Alcohol, Group II: scaffold sterilized with Ethylene Oxide at $65^{\circ}C$, and Group III: scaffold sterilized with Ethylene Oxide at $37^{\circ}C$. To investigate viability of the PC12 cell on the scaffold, The study group and control group in respective were; Control: sterilized with 70% Alcohol, Group I: sterilized with Ethylene Oxide at $65^{\circ}C$, and Group II: sterilized with Ethylene Oxide at $37^{\circ}C$. Results : 1. The surface morphology was slightly changed in Group I, II and Group III, compared with control. 2. The attachment of PC12 cells in Group I, II was not higher than in control Discussion : The attachment of PC12 cell is not influenced by different sterilization methods.

Targeting HSP90 Gene Expression with 17-DMAG Nanoparticles in Breast Cancer Cells

  • Mellatyar, Hassan;Talaei, Sona;Nejati-Koshki, Kazem;Akbarzadeh, Abolfazl
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2453-2457
    • /
    • 2016
  • Background: Dysregulation of HSP90 gene expression is known to take place in breast cancer. Here we used D,L-lactic-co-glycolic acid-polyethylene glycol-17-dimethylaminoethylamino-17-demethoxy geldanamycin (PLGA-PEG-17DMAG) complexes and free 17-DMAG to inhibit the expression of HSP90 gene in the T47D breast cancer cell line. The purpose was to determine whether nanoencapsulating 17DMAG improves the anti-cancer effects as compared to free 17DMAG. Materials and Methods: The T47D breast cancer cell line was grown in RPMI 1640 supplemented with 10% FBS. Encapsulation of 17DMAG was conducted through a double emulsion method and properties of copolymers were characterized by Fourier transform infrared spectroscopy and H nuclear magnetic resonance spectroscopy. Assessment of drug cytotoxicity was by MTT assay. After treatment of T47D cells with a given amount of drug, RNA was extracted and cDNA was synthesized. In order to assess HSP90 gene expression, real-time PCR was performed. Results: Taking into account drug load, IC50 was significant decreased in nanocapsulated 17DMAG in comparison with free 17DMAG. This finding was associated with decrease of HSP90 gene expression. Conclusions: PLGA-PEG-17DMAG complexes can be more effective than free 17DMAG in down-regulating of HSP90 expression, at the saesm time exerting more potent cytotoxic effects. Therefore, PLGA-PEG could be a superior carrier for this type of hydrophobic agent.

Controlled Release of Paclitaxel from Biodegradable Polymer Films for Drug-Eluting Stents (약물방출 스텐트용 생분해성 고분자 필름으로부터 파크리탁셀의 조절 방출)

  • Kim, Si-Eun;Lee, Bong-Soo;Kim, Jin-Hyang;Park, Kwi-Deok;Han, Dong-Keun
    • Polymer(Korea)
    • /
    • v.34 no.2
    • /
    • pp.172-177
    • /
    • 2010
  • Although many researchers have studied the efficacy of paclitaxel (PTX) on many cells during the last two decades, little work has been reported on the importance of release kinetics inhibiting cell proliferation. The aim of this study is to examine the release behavior of the PTX on various biodegradable polymers such as poly(lactic-co-glycolic acid)(PLGA), poly-L-lactide (PLLA), and polycaprolactone (PCL) for drug-eluting stents (DES). The PTX from the fabricated films was released for 8 weeks and the degree of degradation of the films was observed by FE-SEM. Although the degradation time of PCL was the slowest, the PTX release rate was the fastest among them and followed by PLGA and PLLA with the equivalent PTX concentration. It suggests that hydrophobic drug such as PTX from polymer with low $T_g$ like PCL could be moved easily and released rapidly in body temperature.

Preparation and Evaluation of Bupivacaine Microspheres by a Solvent Evaporation Method (용매증발법에 의한 부피바카인 microsphere의 제조 및 평가)

  • Kwak, Son-Hyok;Hwang, Sung-Joo;Lee, Byung-Chul
    • YAKHAK HOEJI
    • /
    • v.44 no.6
    • /
    • pp.511-520
    • /
    • 2000
  • Various bupivacaine-loaded microspheres were prepared from poly (d,l-lactide) (PLA) or poly (d,l-lactic-co-glycolide) (PLGA) by a solvent evaporation method for the sustained release of drug. PLA and PLGA microspheres were prepared by w/o/w and w/o/o multiple emulsion solvent evaporation, respectively. The effects of process conditions such as emulsification speed, emulsifier type, emulsifier concentration and internal/external phase ratio on the characteristics of microspheres were investigated. The prepared microspheres were characterized for their drug loading, size distribution, surface morphology and release kinetics. Drug loading efficiency was higher in the microspheres prepared by w/o/o multiple emulsion than that by w/o/w multiple emulsion method, because the solubility of bupivacaine HCI was decreased in oil phase compared with water phase. The prepared microspheres had an average diameter between 1 and $2\;{\mu}M$ in all conditions of two methods. In morphology studies the PLA microspheres showed an irregular shape and smooth surface, but PLGA microspheres had a spherical shape and smooth surface. The release pattern of the drug from microspheres was evaluated on the basis of the burst effect and the extent of the release after 24h. The in vitro release of bupivacaine HCl from microspheres showed a large initial burst release and $60{\sim}80%$ release within one day in all conditions of two methods. The extents of the burst release against PLA and PLGA microspheres were $30{\sim}50%$ and $50{\sim}80%$ within 20min, respectively. This burst release seems to be due to the smaller size of microspheres and the solubility of drug in water.

  • PDF

Preparation and Evaluation of Chrysin Encapsulated in PLGA-PEG Nanoparticles in the T47-D Breast Cancer Cell Line

  • Mohammadinejad, Sina;Akbarzadeh, Abolfazl;Rahmati-Yamchi, Mohammad;Hatam, Saeid;Kachalaki, Saeed;Zohreh, Sanaat;Zarghami, Nosratollah
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3753-3758
    • /
    • 2015
  • Background: Polymeric nanoparticles are attractive materials that have been widely used in medicine for drug delivery, with therapeutic applications. In our study, polymeric nanoparticles and the anticancer drug, chrysin, were encapsulated into poly (D, L-lactic-co-glycolic acid) poly (ethylene glycol) (PLGA-PEG) nanoparticles for local treatment. Materials and Methods: PLGA: PEG triblock copolymers were synthesized by ring-opening polymerization of D, L-lactide and glycolide as an initiator. The bulk properties of these copolymers were characterized using 1H nuclear magnetic resonance spectroscopy and Fourier transform infrared spectroscopy. In addition, the resulting particles were characterized by scanning electron microscopy. Results: The chrysin encapsulation efficiency achieved for polymeric nanoparticles was 70% control of release kinetics. The cytotoxicity of different concentration of pure chrysin and chrysin loaded in PLGA-PEG ($5-640{\mu}M$) on T47-D breast cancer cell line was analyzed by MTT-assay. Conclusions: There is potential for use of these nanoparticles for biomedical applications. Future work should include in vivo investigation of the targeting capability and effectiveness of these nanoparticles in the treatment of breast cancer.

A Clinical Comparision of Nonresorbable and Resorbable Membrane in the Treatment of Human Class II Furcation Defects (II급 치근이개부병변에서 비흡수성막과 흡수성막을 이용한 조직유도재생술의 임상적 비교)

  • Jang, Chae-Yun;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.689-711
    • /
    • 2001
  • The purpose of this study was to compare clinical results of guided tissue regeneration(GTR) using either a nonresorbable ePTFE membrane or a resorbable membrane made from a synthetic copolymer of glycolide and lactide(PLGA) in the treatment of human class Ⅱ furcation defects. The ePTEE membranes were applied to 16 patients with maxillary molar buccal class Ⅱ furcation defects as Group I, PLGA membranes were applied to 15 patients with maxillary molar buccal class Ⅱ furcation defects as Group Ⅱ, ePTFE membranes were applied to 20 patients with mandibular molar buccal class Ⅱ furcation defects as Group Ⅲ and PLGA membranes were applied to 20 patients with mandibular molar buccal class Ⅱ furcation defects as Group Ⅳ and bone graft materials(DFDBA) were applied in all groups. Probing depth, gingival recession, clinical attachment level, tooth mobility and sulcus bleeding index(SBI) were measured at baseline, 3, 6 and 12months postoperatively. In addition, membrane exposure levels were measured at surgery, 1, 2 and 6weeks postoperatively and postoperative complications were evaluated. The results were as follows: In all groups, there were statistically significant differences in probing depth reduction, gain of clinical attachment and mobility reduction at values of 3, 6 and 12months postoperatively compared to values of baseline, whereas no significant differences in SBI except Group I and gingival recession(p<0.05). Membrane exposure levels were increased at 1, 2 and 6weeks postopratively compared to value of baseline in Group I(p<0.05). There were no statistically significant differences between ePTFE and PLGA membrane in probing depth, clinical attachment level and SBI. There were minimal gingival recession and membrane exposure in Group Ⅳ and pain and swelling were the most common postoperative complications in Group Ⅱ, Ⅲ(p<0.05). In conclusion, this study showed that both nonresorbable membrane and resorbable membrane were effective similarly in the treatment of class Ⅱ furcation defects, without statistical differences in clinical measurements.

  • PDF

Cellular-uptake Behavior of Polymer Nanoparticles into Consideration of Biosafety

  • Do, Jeong-Hoe;An, Jeong-Ho;Joun, Yong-Seung;Chung, Dong-June;Kim, Ji-Heung
    • Macromolecular Research
    • /
    • v.16 no.8
    • /
    • pp.695-703
    • /
    • 2008
  • Nanoparticles have tremendous potential in cancer prevention, detection and augmenting existing treatments. They can target tumors, carry imaging capability to document the presence of tumors, sense pathophysiological defects in tumor cells, deliver therapeutic genes or drugs based on the tumor characteristics, respond to external triggers to release an appropriate agent, document the tumor response, and identify the residual tumor cells. Nanoparticles < 30 nanometers in diameter show unexpected and unique properties. Furthermore, particles < 5 nanometers in size can easily penetrate cells as well as living tissues and organs. This study evaluated the safety of nano materials in a living body and the relationship between the living tissue and synthetic nano materials by examining the in-vitro cytotoxicity of poly(lactic-co-glycolic) acid (PLGA) nano-spheres and fluorescein isothiocynate(FITC)-labeled dendrimers as polymer nanoparticles. PLGA was chosen because it has been used extensively for biodegradable nanoparticles on account of its outstanding bio-compatibility and its acceptance as an FDA approved material. The dendrimer was chosen because it can carry a molecule that recognizes cancer cells, a therapeutic agent that can kill those cells, and a molecule that recognizes the signals of cell death. Cytotoxicity in L929 mouse fibroblasts was monitored using MTT assay. Microscopic observations were also carried out to observe cell growth. All assays yielded meaningful results and the PLGA nanoparticles showed less cytotoxicity than the dendrimer. These nano-particles ranged in size from 10 to 100 nm according to microscopy and spectroscopic methods.

Preparation of Magnetite Nanoparticles Encapsulated with Biodegradable Polymer (PLGA) (생분해성 고분자(PLGA)로 캡슐화한 Magnetite 나노입자의 제조)

  • Lee, Ho-Seok;Choung, Il-Yeop;Song, Ki-Chang;Ahn, Yang-Kyu;Choi, Eun-Chung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.1
    • /
    • pp.107-110
    • /
    • 2006
  • Magnetite nanoparticles encapsulated with biodegradable polymer [poly(D,L-lactide-co-glycoiide), PLGA] were prepared by an emulsification-diffusion method. To investigate the effect of type of organic solvents on the mean particle sizes of obtained composite particles, different organic solvents [ethyl acetate (EA), propylene carbonate (PC) and acetone (ACE)] were used with a stabilizer [didodecyl dimethyl ammonium bromide (DMAB)]. The particle size of nanoparticles was observed by the dynamic light scattering method. When EA and PC as partially water-soluble solvents were used, small composite nanoparticles below 80nm were obtained, while large composite nanoparticles above 330nm were prepared for ACE as a fully water-soluble solvent.

Binding of Vaccine and Poly(DL-lactide-co-glycolide) Nanoparticle Modified with Anionic Surfactant (음이온성 유화제로 수식된 폴리락티드/글리코리드 공중합체 나노 입자와 백신의 결합성)

  • Choi, Min-Soo;Park, Eun-Seok;Chi, Sang-Cheol;Shin, Byung-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.3
    • /
    • pp.177-183
    • /
    • 2004
  • Recently, studies on intranasal mucosa delivery of influenza vaccine have been actively developed because of lack of pain and ease of administration. We studied on preparation of nanoparticle delivery system using biodegradable polymer as a poly(DL-lactide-co-glycolide) (PLGA) and their binding characteristics with vaccine. Three kinds of PLGA nanoparticles were prepared by spontaneous emulsification solvent diffusion (SESD) method using sodium dodecyl sulfate and sodium laurate as an anionic surfactant and Lutrol F68 (polyethylene glycol-block-polypropylene glycol copolymer) as a nonionic surfactant. The 5-aminofluorescein labeled vaccine was coated on the surface of nanoparticles by ionic complex. The complexes between vaccine and nanoparticles were confirmed by change of the size. After vaccine coating on the surface of anionic nanoparticles, particle size was increased from 174 to 1,040 nm. However the size of nonionic nanoparticles was not more increased than size of anionic nanoparticles. The amount of coated vaccine on the surface of PLGA nanoparticles was $14.32\;{\mu}g/mg$ with sodium dodecyl sulfate, $12.41\;{\mu}g/mg$ with sodium laurate, and $9.47{\mu}g/mg$ with Lutrol F68, respectively. In conclusion, prepared nanoparticles in this study is possible to use as a virus-like nanoparticles and it could be accept in the field of influenza vaccine delivery system.

Clinical study on therpeutic effects of Guided tissue regeneration by $Nanogide-C^{(R)}$ and $Biomesh^{(R)}$ in furcation defects (($Nanogide-C^{(R)}$$Biomesh^{(R)}$를 이용한 이개부 결손부에 대한 조직유도재생술의 임상효과)

  • Han, Kyung-Hee;Jung, Jong-Won;Hyun, Ha-Na;Kim, Ji-Man;Kim, Yun-Sang;Pi, Sung-Hee;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.877-889
    • /
    • 2005
  • This study was designed to compare the effects of treatment using chitosan membrane $(Nanogide-C^{(R)})$ resorbable barrier with control treated by polylactic acid/polylacticglycolic acid membrane(PLA/PLGA membrane, $Biomesh^{(R)}$). 44 furcation defecs from 44 patients with class 2 furcation degree were used for this study, 22 sites of them were treated by chitosan membrane as experimental group and 22 site were treated by PLA/PLGA membrane as control group. Clinical parameters including probing depth, gingival recession, attachment level and radiographic examination were evlauated at base line, 1 month, 2 month and 3 month. after surgery. Statistical test used to analyze these data included paired t-test, one way ANOVA. The results are as follows : 1. Probing depth was significanlly decreased in the two group and there were significant differences between groups(p<0.05). 2. Gingival recession was not significanlly increased in the two group and there were no significant differences between groups(p<0.05). 3. Loss of attachment was statistically decreased in the two group and there were no significant differences between groups(p<0.05). 4. Horizontal bone level was significanlly increased in the two group and there were significant differences between groups(p<0.05). On the basis of these results, chitoans resorbable membrane has similar potential to PLA/PLGA membrane in GTR for furcation defect.