• Title/Summary/Keyword: PK method

Search Result 160, Processing Time 0.031 seconds

TPACK of Faculty in Higher Education: Current Status and Future Directions

  • KIM, Dongsim;KIM, Wonsik
    • Educational Technology International
    • /
    • v.19 no.1
    • /
    • pp.153-173
    • /
    • 2018
  • The purpose of this study was to investigate teaching competence of faculty members based on TPACK which should be examined to ensure high quality in higher education. This study was conducted with a focus on TPACK, which integrate technology knowledge (TK), content knowledge (CK), and pedagogy knowledge (PK). Except insincere responses data from a total of 85 participants were used for data analysis in this study. K-mean cluster analysis method was used to examine how faculty members could be distinguished depending on TPACK type. Study results showed that there were three different types of faculty groups (well-balanced competence type, development required competence type, and lack of technology competence type). First, faculty members defined as well balanced competence type were more than the average level in TPACK. Second, faculty members belonged to development required competence type reported below the average level in TPACK. Thus, faculty members in this type were required to increase teaching competence. Finally, faculty members in lack of technology competence type were needed to enhance competence related to technology because their overall TK level was relatively low. This study examined what distinctive characteristics exited in each type depending on gender, teaching career, nationality, and age. Results from this study offered a basis for better understanding TPACK for enhancing teaching competence at the university level.

Pharmacokinetic Analysis of Levofloxacin in Healthy Korean Volunteers

  • Kim, Seung-Yong;Chung, Youn-Bok;Pyo, Hee-Soo;Kwon, Oh-Seung
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.4
    • /
    • pp.235-240
    • /
    • 2008
  • A sensitive and simple method of determining the plasma levofloxacin (LFX, CAS 100986-85-4) concentrations in human volunteers by liquid-liquid extraction were developed and validated by using a high-performance liquid chromatography/diode array detector. The method was also applied to pharmacokinetic study of LFX. LFX was orally administered to 8 healthy male Korean volunteers at single lowest dose of 200 mg, compared to the published reports in which more than 500 mg of LFX was orally administered. LFX in human plasma was determined. The detection limit of LFX was $0.05\;{\mu}g/mL$. $C_{max}$ value was $2.48{\pm}0.67\;{\mu}g/mL$. $AUC_{0{\to}24\;hr$} and $AUC_{0{\to}{\infty}}$ were $14.52{\pm}3.35\;{\mu}g/mL$ and $16.00{\pm}3.66\;{\mu}g{\cdot}hr/mL$, respectively. The terminal half-life was $6.87{\pm}0.46\;hr$. Our pharmacokinetic parameters were very consistent with that previously reported, showing good correlation between LFX doses and AUC ($r^2=0.995$). This method can be useful for the pharmacokinetics and bioequivalence study with relatively low dose for reducing the main side effects of LFX.

Adhesion Behavior of Graphene Oxide on Spherical Polymer Particles (그래핀 산화물-구형 고분자 입자 사이의 흡착 거동)

  • Kim, Sinwoo;Lee, Sang-Soo;Lee, Jonghwi
    • Polymer(Korea)
    • /
    • v.37 no.2
    • /
    • pp.162-166
    • /
    • 2013
  • Graphene-coated polymer particles have attracted research interests due to their emerging applications derived from their controlled structure and morphology. To control the properties of graphene oxide (GO)-polystyrene (PS) composite particles, the adsorption time and instantaneous adsorption conditions were investigated by varying their mixing method. Polystyrene particles prepared by emulsion polymerization were modified to have positive surface charge by adsorption of polyethylene imine (PEI) on the surface of PS particles. GO prepared by the chemical exfoliation method had negative surface charge from the oxygenated groups. The adsorption of the negatively charged GOs onto the positively charged PS particles was successfully completed, and it was found that a longer adsorption time and a greater difference in the instantaneous relative concentration led PS-GO particles to have more homogeneously coated surfaces without aggregation.

3-Dimensional Coating Polymer Microneedles for Economical and Efficient Transdermal Drug Delivery (경제적이고 효과적인 경피 약물전달을 위한 3차원 구조의 코팅 고분자 마이크로니들)

  • Lee, Han-Sol;Park, Jung-Hwan
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.391-396
    • /
    • 2014
  • Polymer microneedles can be fabricated by a micromolding method, an easy and cost-effective method. However, it is not easy to achieve uniform coating with an aqueous coating solution due to hydrophobic surface of polymer microneedles. 3-Dimensional coating polymer microneedles could deliver more than twice as much dose as in-plane metal microneedles by increasing coating area and the number of microneedles per unit area. A uniform coating was not obtained by addition of coating additives in the coating solution. The satisfied coating was achieved by treatment of surface of polymer microneedle with metal deposition and UV/ozone, and UV/ozone treatment was an ultimate surface treatment method based on biological safety. Calcein coating polymer microneedles were prepared by using UV/ozone treatment and followed dip-coating, and they delivered calcein in porcine skin successfully after 15 min of insertion.

Thermal Conductivity of Thermally Conductive Ceramic Composites and Silicon Carbide/Epoxy Composites through Wetting Process (세라믹 방열 복합체의 열전도도 분석 및 Wetting Process를 이용한 SiC/에폭시 복합체)

  • Hwang, Yongseon;Kim, Jooheon;Cho, WonChul
    • Polymer(Korea)
    • /
    • v.38 no.6
    • /
    • pp.782-786
    • /
    • 2014
  • Various kinds of thermal conductive ceramic/polymer composites (aluminum nitride, aluminum oxide, boron nitride, and silicon carbide/epoxy) were prepared by a casting method and their optical images were observed by FE-SEM. Among these, SiC/epoxy composite shows inhomogeneous dispersion features of SiC and air voids in the epoxy matrix layer, resulting in undesirable thermal conductive properties. To enhance the thermal conductivities of SiC/epoxy composites, the epoxy wetting method which can directly infiltrate the epoxy droplet onto filtrated SiC cake was employed to fabricate the homogeneously dispersed SiC/epoxy composite for ideal thermal conductive behavior, with maximum thermal conductivity of 3.85W/mK at 70 wt% of SiC filler contents.

Preparation and Characterization of Solid Dispersions of Eprosartan Using Spray Drying Method (분무 건조 방식으로 제조한 에프로살탄 고체분산체 제조 및 특성 분석)

  • Hwang, Jun Seok;Kim, So Hee;Cho, Sun Hang;Huh, Kang Moo
    • Polymer(Korea)
    • /
    • v.37 no.4
    • /
    • pp.442-448
    • /
    • 2013
  • In this study, we developed and optimized hydrophilic polymer-based solid dispersion formulations (SDs) using a spray drying method for improving the aqueous solubility of eprosartan, one of poorly soluble drugs that has been broadly used for the treatment of high blood pressure. Hydroxylpropylcellulose (HPC) and poly(vinyl pyrrolidone) (PVP) were used as hydrophilic polymer matrices and poloxamer 407 (P407) added as a polymeric surfactant. Various kinds of solid dispersions with different drug/polymer compositions were prepared and their physico-chemical properties were compared. As the polymer content increased, the drug crystallinity in the SDs significantly decreased and the dissolution properties were enhanced. The PVP based SDs were observed to have relatively reduced crystallinity and an enhanced dissolution rate than HPC-based SDs, due to better miscibility between drug and polymer matrix. For PVP based SDs, the drug crystallinity almost disappeared and the dissolution properties significantly increased by more than 3~7 times.

Manufacture and Properties of PMMA Grafted Starch/Carbon Black/NBR Composites (PMMA 그래프트 전분/카본블랙/NBR 복합체의 제조와 물성)

  • Kim, Min-Su;Cho, Ur Ryong
    • Polymer(Korea)
    • /
    • v.37 no.6
    • /
    • pp.764-769
    • /
    • 2013
  • Starch was grafted by poly(methyl methacrylate) through the emulsion polymerization method. Modified starch/(acrylonitrile-butadiene rubber) (NBR) compounds were prepared by a latex blend method. The morphology, thermal properties and mechanical properties of the modified starch/carbon black/NBR composites were investigated with the change of starch concentration. The mechanical properties of the composites were improved by the addition of modified starch. But, when the concentration of modified starch was higher than 40 phr, the mechanical properties were deteriorated due to the poor dispersion of modified starch. At the same ratio of starch to carbon black, the composite showed a synergistic reinforcing effect by the good dispersion and high cross-linking density. In addition, the tensile strength, storage modulus, hardness, swelling and other properties were the best.

Synthesis and Characterization of Polypropylene-grafted Graphene Oxide via "Grafting-to" Method (폴리프로필렌으로 그래프트된 그래핀 옥사이드 제조 및 특성 분석)

  • Lee, Jong-Hee;Oh, Chang-Ho;Lim, Jung-Hyurk;Kim, Kyung-Min
    • Polymer(Korea)
    • /
    • v.39 no.1
    • /
    • pp.180-184
    • /
    • 2015
  • PP-grafted GO was prepared by the reaction of graphene oxide (GO) containing 2-bromoisobuyryl groups and polypropylene (PP) having hydroxyl groups (PP-OH) via a "grafting-to" method. GO-Br was synthesized by the reaction of GO and 2-bromoisobutyryl bromide under a basic condition. PP-MAH was reacted with ethanolamine to produce PP-OH. The melting temperature of PP-grafted GO was shifted to the higher temperature than that of PP-OH. Also, the thermal stability of PP-grafted GO was increased as compared to PP-OH and GO. These results demonstrated that the grafted coating polymer PP was effective for enhancing the thermal stability of GO. The higher surface roughness of PP-grafted GO was resulted from the chemical attachment of PP on the surface of GO. The characterization of PP-grafted GO was conducted from Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and scanning electron microscope (SEM).

Effects of Melt-blending Condition and Additives on Mechanical Properties of Wood/PP Composites (용융혼합 조건과 첨가제가 목분/폴리프로필렌 복합체의 기계적 특성에 미치는 영향)

  • Ahn, Seong Ho;Kim, Dae Su
    • Polymer(Korea)
    • /
    • v.37 no.2
    • /
    • pp.204-210
    • /
    • 2013
  • Effects of additives (lubricant and antioxidant) and melt-blending condition (temperature, time and rotor speed) on the mechanical properties of polypropylene-based wood polymer composites (WPCs) were investigated. WPCs were prepared by melt-blending followed by compression molding. To understand melt-blending procedure, torque change of the WPC melt-blend was monitored. Maleic anhydride modified PP and nanoclay were used as a compatibilizer and a reinforcing filler, respectively. UTM and izod impact tester were used to measure the mechanical properties of the WPCs and a color-difference meter was used to measure the discoloration of the WPCs according to melt-blending condition. The mechanical properties showed that the optimized melt-blending condition was $170^{\circ}C$, 15 min, and 60 rpm. The mechanical properties of the WPCs decreased with increasing lubricant and antioxidant content. The two step method, adding wood flour later separately during melt-blending, was more effective than the typical one step method for improving the mechanical properties of the WPCs.

Development of Drug Eluting Stent for the Treatment of Benign Biliary Stricture by Electro-spray Method (전기분사를 이용한 양성담관 협착 치료용 약물방출 스텐트 개발)

  • Shin, Il-Gyun;Kim, Dong-Gon;Kim, Han-Ki;Kim, Sang-Ho;Jeon, Dong-Min;Suh, Tae-Seok;Jang, Hong-Seok
    • Polymer(Korea)
    • /
    • v.36 no.2
    • /
    • pp.163-168
    • /
    • 2012
  • Recently, along with technology development of endoscopic equipment, the stent technology has been developed for the convenience of operation, shortening of recovery times, and reduction of patient's pain. In this study, paclitaxel-eluting metal stents for treatment of biliary benign stenosis were developed through an electrospray-coating method. Polyether-based polyurethane (PELLETHANE 2363-80AE$^{(R)}$)) and paclitaxel were coated onto the surface of a metallic stent and Pluronic F127 was used as an additive. As a result, physicochemical characterization of paclitaxel via SEM, FTIR, contact angle and XRD techniques revealed the information of solid state of paclitaxel-loaded PU film. The in vitro release profile showed a slower release rate with a higher content of paclitaxel.