• 제목/요약/키워드: P2P Grid

검색결과 203건 처리시간 0.028초

A Novel Photovoltaic Power Harvesting System Using a Transformerless H6 Single-Phase Inverter with Improved Grid Current Quality

  • Radhika, A.;Shunmugalatha, A.
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.654-665
    • /
    • 2016
  • The pumping of electric power from photovoltaic (PV) farms is normally carried out using transformers, which require heavy mounting structures and are thus costly, less efficient, and bulky. Therefore, transformerless schemes are developed for the injection of power into the grid. Compared with the H4 inverter topology, the H6 topology is a better choice for pumping PV power into the grid because of the reduced common mode current. This paper presents how the perturb and observe (P&O) algorithm for maximum power point tracking (MPPT) can be implemented in the H6 inverter topology along with the improved sinusoidal current injected to the grid at unity power factor with the average current mode control technique. On the basis of the P&O MPPT algorithm, a power reference for the present insolation level is first calculated. Maintaining this power reference and referring to the AC sine wave of bus bars, a sinusoidal current at unity power factor is injected to the grid. The proportional integral (PI) controller and fuzzy logic controller (FLC) are designed and implemented. The FLC outperforms the PI controller in terms of conversion efficiency and injected power quality. A simulation in the MATLAB/SIMULINK environment is carried out. An experimental prototype is built to validate the proposed idea. The dynamic and steady-state performances of the FLC controller are found to be better than those of the PI controller. The results are presented in this paper.

선박 및 실내 N-스크린 서비스를 위한 WPAN 프로토콜 (A WPAN Protocol for N-Screen Services in Indoor and Ship Area Networks)

  • 허경;이성로
    • 한국통신학회논문지
    • /
    • 제40권6호
    • /
    • pp.1185-1192
    • /
    • 2015
  • 센서장비에 장착되는 무선통신 모듈은 선내 통합유무선 네트워크와의 원활한 연결을 위하여 무선 게이트웨이 기능을 수행하는 브릿지(bridge)를 통한 데이터 전송방식이 필요하다. 본 논문에서는 선박 및 실내 Seamless N-스크린 서비스를 위한 무선 통신 MAC 구조로서, WPAN 프로토콜을 적용하고, P2P 스트리밍이 가능한 OSMU(One Source Multi Use) N-스크린 서비스를 제공하기 위해, 그리드 기반 WPAN 네트워킹 기술을 제안하고 성능을 분석하였다. 제안한 그리드 기반 WPAN 네트워킹 기술은 다중 경로 및 신속한 경로 설정이 가능한 N-스크린 통신을 지원한다. 제안한 방식을 시뮬레이션한 결과, 그리드 기반 WPAN 네트워킹 기술은 IEEE 802.15.4 기반망 보다 전송지연시간 측면에서 우수한 성능을 나타내었다.

P2P 기반 그리드 정보 서비스 모델의 설계 및 구현 (Design and Implementation of P2P based Grid Information System)

  • 강윤희;강경우;김도현;조광문;궁상환
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2003년도 춘계학술발표논문집
    • /
    • pp.161-164
    • /
    • 2003
  • 현재의 MDS 시스템은 제한적인 캐슁에 따른 불필요한 그리드 정보서비스 서버 접근, 다양한 응용 사용자를 위한 최적의 자원 정보 발견의 어려움 및 DIT 내의 노드 결합 또는 네트워크 단절에 따른 서비스 중단의 문제점 등을 갖는다. 본 연구에서는 기존의 그리드 컴퓨팅을 위한 미들웨어인 Globus의 정보 서비스 시스템인 MDS의 확장을 기술한다. 제안된 확장 시스템은 자원 접근 및 발견을 위해 P2P 기반의 결함 포용을 갖는 강건하고 적응형 정보 서비스를 제공하기 위한 모텔 설계를 수행한다. 특히, 그리드 정보서비스는 단일 기점 결함(Single-point failure) 및 중복으로 등록된 자원에 대한 추가적인 트래픽을 발생시킨다. 본 연구에서는 기존의 MDS에 강건성을 갖고 네트워크 트랙픽 감소를 위해 P2P를 기반으로 확장된 그리드 정보서비스 아키텍츄어 설계를 제안하며 이를 위한 결함 검출 시스템을 Apples를 기반으로 구성하였다.

  • PDF

Adaptive Neural PLL for Grid-connected DFIG Synchronization

  • Bechouche, Ali;Abdeslam, Djaffar Ould;Otmane-Cherif, Tahar;Seddiki, Hamid
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.608-620
    • /
    • 2014
  • In this paper, an adaptive neural phase-locked loop (AN-PLL) based on adaptive linear neuron is proposed for grid-connected doubly fed induction generator (DFIG) synchronization. The proposed AN-PLL architecture comprises three stages, namely, the frequency of polluted and distorted grid voltages is tracked online; the grid voltages are filtered, and the voltage vector amplitude is detected; the phase angle is estimated. First, the AN-PLL architecture is implemented and applied to a real three-phase power supply. Thereafter, the performances and robustness of the new AN-PLL under voltage sag and two-phase faults are compared with those of conventional PLL. Finally, an application of the suggested AN-PLL in the grid-connected DFIG-decoupled control strategy is conducted. Experimental results prove the good performances of the new AN-PLL in grid-connected DFIG synchronization.

Mesh/grid 기반 투명 전극의 구조 최적화

  • 윤민주;김경헌;박상영;김희동;안호명;김태근
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.411-412
    • /
    • 2013
  • 최근 UV LED는 생화학 및 의료 산업에서 많은 각광을 받고 있다. 특히, 360nm 이하의 파장대를 갖는 UV LED는 치료 기술, 센서, 물이나 공기 등의 정화와 같은 목적으로 특별한 관심이 쏠리고 있다 [1]. 이러한 지속적인 연구를 통하여 현재까지 UV LED는 거대한 성장을 이루어 왔다. 하지만 이러한 노력에도 불구하고, 360 nm 이하의 UV LED는 여전히 오믹 접촉과 전류 분산이 원활하지 못하다는 문제점을 가지고 있다. 이것은 UV LED의 외부 양자 효율을 감소시키고, 더 나아가 극도로 낮은 광 추출 효율을 초래한다. 최근 이러한 문제를 해결하고자, 투명 전도성 산화물(TCO)을 금속 전극과 p-AlGaN 사이에 삽입해주는데, 현재 가장 널리 사용되는 TCO 물질은 ITO 이다 [2]. 하지만 ITO 물질은 상대적으로 작은 밴드갭(3.3~4.3 eV)과 단파장 빛이 가지는 큰 에너지로 인하여 deep-UV 영역에서는 빛이 투과하지 못하고 대부분 흡수된다 [3]. 따라서 본 연구에서는 기존의 박막형 ITO 투명 전극에 비해 투과도 손실을 최소화할 수 있는 mesh, grid 기반의 투명전극을 연구하였다. Fig. 1과 같이 $5{\mu}m$, $10{\mu}m$, $20{\mu}m$ 간격으로 이루어진 mesh, grid 구조의 투명전극을 구현하여 투과도 손실을 최소화하면서 우수한 전기적 특성을 확보하기 위한 구조 최적화 연구를 진행하였다. 본 연구를 위해 mesh, grid 구조의 ITO 전극 패턴을 photolitho 공정으로 형성하였으며, e-beam 증착법으로 60 nm 두께의 ITO 전극을 형성 후 질소 분위기/$650^{\circ}$에서 30초 동안 RTA 공정을 진행하였다. Fig. 1에서 볼 수 있듯이 mesh, grid의 간격이 증가할수록 투명 전극이 차지하는 면적이 감소하여 투과도는 향상되는 반면, 투명 전극과 p-GaN과의 접촉 면적 또한 감소하므로 오믹 특성이 저하된다. 따라서 투과도 손실을 최소화하면서 우수한 전기적 특성을 확보하기 위해 mesh는 $20{\mu}m$, grid는 $10{\mu}m$ 간격의 구조로 각각 최적화하였다. 그 결과 박막 기반의 ITO 투명전극 대비 최대 약 10% 향상된 투과도를 확보하였으며, I-V Curve 결과를 통하여 p-GaN 기판과 mesh 구조의 ITO 전극 사이에 박막 기반의 투명 전극과 비슷한 수준인 $0.35{\mu}A(@5V)$의 전기적 특성을 확보하였다. 결과적으로 mesh, grid 기반 투명전극의 구조 최적화를 통하여 p-GaN과 원활한 오믹 접촉을 형성하는 동시에 기존 박막형 ITO 투명 전극 구조보다 높은 투과도를 확보할 수 있었다.

  • PDF

Blockchain for Securing Smart Grids

  • Aldabbagh, Ghadah;Bamasag, Omaimah;Almasari, Lola;Alsaidalani, Rabab;Redwan, Afnan;Alsaggaf, Amaal
    • International Journal of Computer Science & Network Security
    • /
    • 제21권4호
    • /
    • pp.255-263
    • /
    • 2021
  • Smart grid is a fully-automated, bi-directional, power transmission network based on the physical grid system, which combines sensor measurement, computer, information communication, and automatic control technology. Blockchain technology, with its security features, can be integrated with Smart Grids to provide secure and efficient power management and transmission. This paper dicusses the deployment of Blockchain technology in Smart Grid. It presents application areas and protocols in which blockchain can be applied to in securing smart grid. One application of each area is explored in detail, such as efficient peer-to-peer transaction, lower platform costs, faster processes, greater flexibility in power generation to transmission, distribution and power consumption in different energy storage systems, current barriers obstructing the implementation of blockchain applications with some level of maturity in financial services but concepts only in energy and other sectors. Wide range of energy applications suggesting a suitable blockchain architecture in smart grid operations, a sample block structure and the potential blockchain technicalities employed in it. Also, added with efficient data aggregation schemes based on the blockchain technology to overcome the challenges related to privacy and security in the smart grid. Later on, consensus algorithms and protocols are discussed. Monitoring of the usage and statistics of energy distribution systems that can also be used to remotely control energy flow to a particular area. Further, the discussion on the blockchain-based frameworks that helps in the diagnosis and maintenance of smart grid equipment. We have also discussed several commercial implementations of blockchain in the smart grid. Finally, various challenges have been discussed for integrating these technologies. Overall, it can be said at the present point in time that blockchain technology certainly shows a lot of potentials from a customer perspective too and should be further developed by market participants. The approaches seen thus far may have a disruptive effect in the future and might require additional regulatory intervention in an already tightly regulated energy market. If blockchains are to deliver benefits for consumers (whether as consumers or prosumers of energy), a strong focus on consumer issues will be needed.

P2P를 기반으로 한 확장된 그리드 정보 서비스 시스템 (An Extended Grid Information Service System Based on P2P)

  • 강윤희;강경우;조광문;김도현;궁상환
    • 한국산학기술학회논문지
    • /
    • 제4권3호
    • /
    • pp.270-273
    • /
    • 2003
  • 현재의 MDS 시스템은 제한적인 캐슁에 따른 불필요한 그리드 정보서비스 서버 접근, 다양한 응용 사용자를 위한 최적의 자원 정보 발견의 어려움 및 DIT내의 노드 결함 또는 네트워크 단절에 따른 서비스 중단의 문제점 등을 갖는다. 본 논문에서는 기존의 그리드 컴퓨팅을 위한 미들웨어인 Globus의 정보 서비스 시스템인 MDS 의 확장을 기술한다. 제안된 회장 시스템은 자원 접근 및 발견을 위해 P2P 기반의 결함 포용을 갖는 강건하고 적응형 정보 서비스를 제공하기 위한 모델설계를 구현하였다. 특히, 그리드 정보서비스는 단일 기점 결함(Single-point failure) 문제를 내포하고 있다. 본 연구에서는 확장된 그리드 정보서비스 아키텍츄어 설계를 제안하고 Apples를 기반으로 한 결함 검출 시스템을 구성하였다.

  • PDF

다중 VO 정보를 공유하는 P2P 기반의 VO Finder 서비스 설계 및 구현 (Design and implementation of VO Finder Service sharing multiple VO information based on P2P mechanism)

  • 홍원택;임민열;김은성;박형우
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2004년도 춘계학술발표대회
    • /
    • pp.933-936
    • /
    • 2004
  • 본 논문은 그리드 컴퓨팅 환경에서 필요한 서비스 및 자원 정보를 OGSA(Open Grid Services Architecture) 기반하에 P2P(Peer-to-Peer) 메커니즘을 이용하여 제공하는 방법에 관한 것이다. 기존의 집중화된 그리드 정보 서비스의 구조와는 달리 자원 및 서비스에 대한 정보를 VO(Virtual Organization) 단위의 분산된 형태로 유지하고, VO 정보를 공유함으로써 그리드 정보 서비스들 간의 전역적인 정보 공유가 가능해진다. 본 논문에서는 VO 정보 공유를 가능하게 하는 VO Finder 서비스를 설계하고 구현한다. 그리드 환경을 이용하는 사용자는 VO 정보 공유를 통해 전역적인 서비스 및 자원 정보를 모두 제공받음으로써 OGSA 환경하에서 필요한 서비스 및 자원을 선택하여 이용할 수 있다.

  • PDF

Effects of various freezing containers for vitrification freezing on mouse oogenesis

  • Kim, Ji Chul;Kim, Jae Myeoung;Seo, Byoung Boo
    • Journal of Animal Science and Technology
    • /
    • 제58권3호
    • /
    • pp.13.1-13.7
    • /
    • 2016
  • Background: In the present study, various freezing containers were tested for mouse embryos of respective developmental stages; embryos were vitrified and then their survival rate and developmental rate were monitored. Mouse two cell, 8 cell, and blastula stage embryos underwent vitrification freezing-thawing and then their recovery rate, survival rate, development rate, and hatching rate were investigated. Methods: EM-grid, OPS, and cryo-loop were utilized for vitrification freezing-thawing of mouse embryos. Results: It was found that recovery rate and survival rate were higher in the group of cryo-loop compared to those of EM-grid (p < 0.05). Embryonic development rate, two cell embryos to blastocyst, as well as hatching rate were higher in the control group compared to the EM-grid group and OPS group (p < 0.05), yet no difference was noted between the control group and cryo-loop group. Development rate and hatching rate of eight cell morulae and blastocysts were all lower in the treatment groups than the control group whilst hatching rate of blastocysts was higher in the control group compared to the groups of EM-grid and OPS (p < 0.05); although the cryo-loop group was shown to be slightly higher than other groups, it was not statistically significant. Conclusions: In the study, we investigate effects of freezing containers on vitrified embryos of respective developmental stages; it was demonstrated that higher developmental rate was shown in more progressed (or developed) embryos with more blastomeres. There was however, no difference in embryonic development rate was shown amongst containers. Taken together, further additional studies are warranted with regards to 1) manipulation techniques of embryos for various vitrification freezing containers and 2) preventive measures against contamination via liquid nitrogen.

n-CdS/P-InP 이종접합 다이오드 특성 (A Properties of n-CdS/p-InP Heterojunction Diodes)

  • 송복식;문동찬;김선태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 추계학술대회 논문집
    • /
    • pp.60-63
    • /
    • 1993
  • We have prepared n-CdS/p-InP hetero- junction solar cells by thermal evaporation. The efficiency under the optium conditions without the grid line contact was 7.3%, and the solar cell having glid line contact with SiO AR coating was the open circuit voltage of 0.71V, the short circuit voltage current density of 15mA/cm$^2$, the fill factor of 0.73, and the efficiency of 11.5%. As result of photoresponse in 400-1000nm wavelength the cutoff of n-CdS/p-InP solar at 500nm results from absorption by the CdS \"window\" and the cutoff at 930 nm result from absorption by the InP.

  • PDF