• 제목/요약/키워드: P-wave detection

검색결과 124건 처리시간 0.026초

단계별 기저선 정렬을 이용한 ECG 신호에서 P파와 T파 검출 알고리즘 (P-Waves and T-Wave Detection Algorithm in the ECG Signals Using Step-by-Step Baseline Alignment)

  • 김정홍;이승민;박길흠
    • 한국멀티미디어학회논문지
    • /
    • 제19권6호
    • /
    • pp.1034-1042
    • /
    • 2016
  • The detection of P-waves and T-wave in the electrocardiogram signal analysis is an important issue. But the accuracy of the boundary detection algorithm is an insufficient level in the change of slow transition in the signal compared to the QRS complex. This study proposes an algorithm to detect P-wave and T-wave sequentially after determining local baseline using QRS complex. First, we detected the peak points based on local baseline and determined the onset and offset through the calculation of the area of the section. After modifying the baseline using detected waveform, we detected the other waveform in the same way and separated the P-wave and the T-wave based on the location. We used the PhysioNet QT database to evaluate the performances of the algorithm, and calculate the mean and the standard deviations. The experiment results show that standard deviations are under the tolerances accepted by expert physicians, and outperform the results obtained by the other algorithms.

충격 추진력 변화를 이용한 지진 P파 자동 검출 알고리즘 (Automatic Seismic P-wave Detection Algorithm Using Variations of Impact Momentum)

  • 최훈
    • 전기학회논문지
    • /
    • 제67권7호
    • /
    • pp.884-891
    • /
    • 2018
  • In this paper, we propose an automatic earthquake P-wave detection algorithm based on the variations of the impact momentum derived from the seismic acceleration signals. The amount of change in the impact momentum induced by the acceleration refers to the influence of buildings or facilities on the earthquake, The proposed algorithm can effectively detect the seismic P-wave by simultaneously considering the amplitude and the frequency change of the seismic wave when the earthquake occurs. Computer simulations using the observed seismic signals were performed to evaluate the validity of the induced impact momentum variation and the superiority of the proposed algorithm.

기울기 추적파를 이용한 심전도의 P-파 및 T-파 검출 알고리즘 (A P-wave and T-wave detection algorithm in EGG by using slope tracing waves)

  • 김민규;변미경;이기영;김정국;정병두;허웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.35-37
    • /
    • 2005
  • In this study, a P- and T-wave detection algorithm in ECG, obtained by minimized filtering to prevent waveform distortion, has been realized. The algorithm uses two slope tracing waves, the descending slope tracing wave and the ascending slope tracing wave, developed for efficient determination of slope inverting points and sudden slope changing points. The algorithm generates the slope tracing waves which trace the original ECG wave, and subtracts one tracing wave from the other to detect P- and T-waves. The algorithm has been applied to MIT/BIH database in order to verify its efficacy and validity in practical applications.

  • PDF

템플레이트 매칭에 의한 심전도 신호의 P파 검출 알고리즘에 관한 연구 (A P-wave Detection Algorithm by Template Matching Method)

  • 홍재우;정희교;신건수;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 춘계학술대회
    • /
    • pp.21-24
    • /
    • 1990
  • This paper presents a new algorithm for P-wave detection in the ECG signal, we get the peak, onset and offset point by using significant point extraction algorithm with 5-point derivative. To these set of extracted significant points, we apply amplitude and duration threshold criterion. we define the set of significant point meeting the criterion as P-wave candidate. Then P-wave candidate is classified through match-process with template. The template with maximum number or P-wave candidate is selected to be the P-wave.

  • PDF

특성점 추출에 의한 P파 검출 알고리즘에 관한 연구 (P-wave Detection Algorithm by Significant Point Extraction Method)

  • 황선철;정희교;이명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.162-165
    • /
    • 1989
  • This paper describes an algorithm of P-wave detection by significant point extraction method with digital differentiation. P-waves are detected by pattern matching algorithm with significant points. By means of defecting onset and offset points of P-waves, this algorithm can measure the PR intervals exactly which is important to diagnosis the atrial arrhythmia. Because P-wave duration is changed according to heart-rates, we calculate the R-R interval prior to the determination of P-wave duration threshold values in order to actively adapt to the change of P duration The results obtained from the proposed algorithm have defected successfully P-wave almost more than 90%.

  • PDF

심전도 자동진단을 위한 P파 검출기법의 연구 (A Study on Detection of P-wave for Automated Electrocardiogram Interpreter)

  • 석정욱;권혁제;공인욱;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.201-204
    • /
    • 1995
  • In this study, we proposed an algorithm for P-wave detection. It is essential to decide the existence of P-wave and to extract some parameter about P-wave in automated ECG interpreter. Especially this paper describes the detection and estimation of three case, artrial flutter, coupled and non-coupled, which are very crucial things in ECG diagnosis. The performance of algorithm is showed by applying it to CSE(Common Standards for Quantative Electrocardiography) database.

  • PDF

QRS구간 제거와 이동평균을 통한 대상 영역 추출 기반의 T파 검출 알고리즘 (T Wave Detection Algorithm based on Target Area Extraction through QRS Cancellation and Moving Average)

  • 조익성;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제21권2호
    • /
    • pp.450-460
    • /
    • 2017
  • T파는 심장의 심실의 재분극을 나타내는 파라미터로써 부정맥 진단에 있어 매우 중요하다. T 파를 검출하기 위한 기존 연구방법으로는 주파수 분석과 비선형 접근방법 등이 제안되어 왔지만 검출 정확도가 낮다는 문제점이 있다. 이는 T파의 경우 P파와 중복되는 경우가 발생하기 때문이다. 본 연구에서는 QRS 구간을 제거한 후, 이동평균을 통한 P파와 T파의 대상 영역을 추출하여 정확히 T파를 검출하는 알고리즘을 제안한다. 이를 위해 전처리를 통해 잡음이 제거된 심전도 신호에서 Q, R, S를 검출한다. 이후 검출된 QRS 구간을 제거, 이동평균을 통해 4개의 PAC 패턴과 기타부정맥에 대한 판단규칙을 적용하여 P, T파의 대상 영역을 추출하고, 이를 대상으로 RR 간격과 RT 간격의 문턱치를 적용하여 T파를 검출하였다. 제안한 방법의 우수성을 입증하기 위해 MIT-BIH 부정맥 데이터베이스 48개의 레코드를 대상으로 한 T파의 평균 검출율은 95.32%의 성능을 나타내었다.

적응형 문턱치와 QRS피크 변화에 따른 P파 검출 알고리즘 (P Wave Detection Algorithm through Adaptive Threshold and QRS Peak Variability)

  • 조익성;김주만;이완직;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제20권8호
    • /
    • pp.1587-1595
    • /
    • 2016
  • P파는 심장의 전기적, 생리적 특성을 나타내는 파라미터로써 심방성 부정맥 진단에 있어 매우 중요하다. 하지만 R파에 비해 신호의 크기가 작고 그 형태가 다양하여 검출에 많은 어려움이 있다. P 파를 검출하기 위한 기존 연구방법으로는 주파수 분석과 비선형 접근방법 등이 제안되어 왔지만 방실 차단과 같은 전도 이상이나 심방성 부정맥의 경우에는 검출 정확도가 낮아진다. 이는 심장 상태에 따라 다양한 모양의 P파의 패턴이 존재하기 때문이다. 본 연구에서는 QRS 피크 변화에 따른 P파의 패턴을 분류하고 적응형 문턱치를 이용하여 P파를 검출하는 방법을 제안한다. 이를 위해 전처리를 통해 잡음이 제거된 심전도 신호에서 Q, R, S를 검출한다. 이후 피크 변화에 따른 P파의 3가지 패턴을 분류하고 적응형 윈도우와 문턱치를 통해 P파를 검출하였다. 제안한 방법의 우수성을 입증하기 위해 MIT-BIH 부정맥 데이터베이스 48개의 레코드를 대상으로 한 P파의 평균 검출율은 92.60%의 성능을 나타내었다.

심전도에서 P파의 검출방법에 관한 연구 (A study on P wave detection method in ECG)

  • 주장규;이기영;배철수;이상식
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권1호
    • /
    • pp.17-22
    • /
    • 2011
  • 본 연구에서는 부정맥 판독을 위해 심전도 신호로부터 P파의 강조 및 검출 방법을 제안하였다. 이 방법에서는 고전적인 필터나 이동평균필터를 사용하지 않고 하강 기울기의 변곡점을 검출하기에 효과적인 하강 기울기 추적파를 이용하여 고주파 잡음을 무시해 주는 필터 용도로 사용함과 동시에 진폭이 낮고 불명확한 P파와 T파를 강조해 줌으로써 이들의 검출을 용이하게 하였다. 이 강조 및 검출 방법을 MIT/BIH 데이터에 적용하여 구현하였으며 그 실용성을 확인하였다.

심전도 자동 진단 알고리즘 및 장치 구현(III) - 심방 및 심실활동 검출기 (An implementation of automated ECG interpretation algorithm and system(III) - Detector of atrium and ventricle activity)

  • 권혁제;이정환;윤지영;최성균;이준영;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.288-292
    • /
    • 1996
  • This paper describes far the detection of heart event that is, QRS complex and P wave which are result from heart activity. The proposed QRS detection method by using the spatial velocity was identified as having the 99.6% detection accuracy as well as fast processing time. Atrial flutter, coupled P wave, and noncoupled P wave as well as atrial fibrillation could be detected correctly by three different algorithms according to their origination farm. About 99.6% correction accuracy coupled P wave could be obtained and we could be found that most detection errors are caused by establishing wrong search interval.

  • PDF