• 제목/요약/키워드: P-wave Noise

검색결과 88건 처리시간 0.023초

전기적 잡음이 심한 지역에서 지표-시추공 복합배열 탄성파탐사에 의한 암반등급 산정 (Rock Mass Classification by Surface-borehole Hybrid Array Seismic Refraction Tomography in the Region of Serious Electrical Noises)

  • 김예련;사상호;남순성;조철현;차영호;박종범;신경진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.610-614
    • /
    • 2005
  • Rock mass classification by using electrical resistivity tomography(ERT) method is widely performed for the determination of rock support type in tunnel design. In the region of high electrical noise level, however, the result of the ERT will have many erroneous features. In this study, the back ground electrical noise had been measured to find out the reason why the results of ERT in this area did not agree to the expected geology confirmed by boreholes. In order to overcome this limitation of ERT, a hybrid surface-borehole array seismic refraction tomography had been followed. Using this technique, we could get P-wave velocity section including the depth level of tunnel. The comparison of the P-wave velocity and RMR shows fairly good statistical relationship to make it possible to set up the rock mass classification for the entire tunnel line.

  • PDF

Morphology-pair 연산과 중간 값을 이용한 심전도 신호의 기저선 변동 잡음 제거 (Removing Baseline Drift in ECG Signal using Morphology-pair Operation and median value)

  • 박길흠;김정홍
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권8호
    • /
    • pp.107-117
    • /
    • 2014
  • 본 논문에서는 심전도 파형에서 P, R, T-wave와 같은 local maxima 신호 영역과 Q, S-wave와 같은 local minima 신호영역을 제거하여 기저선 변동 잡음을 제거하기 위한 방법을 제시한다. 이를 위해 형태연산을 개선한 morphology-pair 연산을 심전도 파형에 적용하고, 그 결과 발생되는 돌출 파형을 제거하고자 중간 값 연산을 적용하였다. 제안한 알고리즘의 성능을 확인하기 위해 실제 심전도 임상 데이터인 MIT/BIH 데이터베이스를 이용하였으며, 실험 결과 원 신호를 왜곡 하지 않고, 기저선 변동 잡음을 효과적으로 제거함을 확인하였다.

P파를 이용한 지진 현장 경보체계기술의 국내 적용 (Application of the Onsite Earthquake Early Warning Technology Using the Seismic P-Wave in Korea)

  • 이호준;이진구;전인찬
    • 한국재난정보학회 논문집
    • /
    • 제14권4호
    • /
    • pp.440-449
    • /
    • 2018
  • 연구목적: 본 연구는 단일 지진관측기로부터 P파를 추출하여 PGV를 산출하는 현장지진경보(Onsite EEW)를 설계와 검증을 목적으로 한다. 연구방법: 국내에서 발생한 12개의 지진파형데이터를 이용하여 적합한 P파 감지 시간(PTW)의 크기를 정하여, P파 물성치인 Pd, Pv 및 Pa를 산출하고, 경험식을 통한 PGV 추정값을 관측치와 비교하였다. 연구결과: PGV 관측치와 추정치의 비교결과를 경보 발령 기준인 진도 등급 내에서 비교하였을 때 오보 비율은 최소 86.7%의 적중률을 보였으며, PTW를 2초로 줄이는 효과로 경보시간은 1초, 공백역은 6Km를 단축할 수 있다. 결론: 본 연구를 통해 국내에서 지진현장경보의 가용성을 확인하였으며, 실제 활용을 위해서는 지속적인 관측을 통해 지진파형 데이터수를 늘이고, 현장 노이즈를 제거하는 기술을 통해 한국형의 회귀식과 알고리즘 개발이 필요하다.

YBCO SQUID를 이용한 실험쥐의 심자도 측정 (Rat Magnetocardiograms Measured by YBCO SQUID Magnetometer)

  • 안산;김인선;송종현
    • Progress in Superconductivity
    • /
    • 제12권2호
    • /
    • pp.124-128
    • /
    • 2011
  • We have developed a high-$T_C$ SQUID magnetometer system to measure magnetocardiograms of laboratory rats. White noise of the measurement system was about 50 fT/$Hz^{1/2}$ when measured in a magnetically shielded box. We optimized the measurement position to obtain clear MCG wave from rat's small heart by using grid measurements. With the optimization, the MCG signal was successfully detected with the peak amplitude of about 50 pT. We could observe well defined P-, QRS-, and T-wave from the rat MCG. The results suggest that the developed system has a strong potential to monitor the progress of heart disease model using laboratory rat.

FMCW 레이더용 W-대역 단일칩 수신기 MMIC (W-band Single-chip Receiver MMIC for FMCW Radar)

  • 이석철;김영민;이상호;이기홍;김완식;정진호;권영우
    • 전자공학회논문지
    • /
    • 제49권10호
    • /
    • pp.159-168
    • /
    • 2012
  • 본 논문에서는 $0.15{\mu}m$ GaAs pHEMT 기술을 이용하여 FMCW(Frequency-modulated continuous-wave) 레이더용 W-band 단일칩 수신기 MMIC를 구현하였다. 제작된 수신기는 4 단 저잡음 증폭기, 하향 변환 혼합기, 3 단 LO 버퍼 증폭기로 구성되어 있다. 수신기의 저잡음 특성과 선형성 향상을 위해 저잡음 증폭기의 성능을 최적화시켰다. 혼합기는 선형성 특성 및 낮은 IF 주파수에서 저잡음 특성을 위하여 저항성 혼합기로 설계하였다. W-대역에서 혼합기를 구동시키기 위해서는 높은 LO 입력이 요구되므로 추가적인 LO 버퍼 증폭기를 설계하였다. 단일칩 수신기의 측정 결과, RF 주파수 $f_0$ GHz, LO 입력 전력 -1 dBm, 그리고, IF 주파수 100 MHz에서, 6.2 dB의 변환 이득, 5.0 dB의 잡음 지수, 그리고, -12.8 dBm의 1-dB 이득 감쇄 입력 전력($P_{1dB,in}$) 등의 우수한 특성을 얻었다.

에어로빅스가 청각유발전위에 미치는 영향 (The Effects of an Aerobics on the Auditory Evoked Potential)

  • 박상남;김영활;김병원
    • 대한임상검사과학회지
    • /
    • 제38권3호
    • /
    • pp.224-230
    • /
    • 2006
  • Up to now, there have been rare clinical studies on leaders and aerobics athletes. To get the useful data for protecting from auditory disorder, we selected 15 female aerobics leaders (experimental group) and 15 females (control group) unexperienced in aerobics and a without neurological and octolaryngological disorder. The average age was $34.87{\pm}8.80$ (experimental group) and $34.07{\pm}8.45$ (control group) years, and the average career of an aerobics leader (experimental group) was $8.33{\pm}4.73$ years. We measured the auditory evoked potential (AEP) of the two groups treated with 70, 75 and 85 dB intensity from January 2006 to May 2006 and analyzed the absolute latency (AL) and interpeak latency (IPL) by the SPSS/pc+ 12.0 program. In the comparison of the AL between the experimental group and the control group according to intensity, both ears treated with 70 and 75 dB had a significant difference (p<0.05) in the I, III, V wave and in the I, V wave respectively, and the experimental group treated with 85 dB showed a difference in the I, III, V wave (left ear) and in the I wave (right ear) respectively. The IPL of the two groups treated with various intensities had no prolongation. In the comparison of the AL between the experimental group and the control group according to ages, the experimental group in their 20s treated with 70 dB showed a significant difference (p<0.05) in the V wave (left ear) and in the I, III, V wave (right ear), and the experimental group in their 20s treated with 75 dB in the I, III wave (left ear) and in I, III, V wave (right ear), and experimental group in their 20s treated with 85 dB in the V wave (left ear) and in the III, V wave (right ear). The experimental group in their 30s treated with 70 dB had a significant difference (p<0.05) only in the V wave (right ear). Only in the IPL of subjects in their 20s treated with 85 dB, III-V and I-V of both ears was extended. In the comparison of the AL and IPL according to career, there was no significant difference between the two groups. From this results, we concluded that the lower sound intensity (70 dB) showed a more significant difference in the experimental group than the control group. We concluded that the leader of aerobics exposed to louder sounds than normal people are affected by auditory neurological and octolaryngological disorders. So we think that the leaders of aerobics need to control the noise level for protecting themselves against a disease.

  • PDF

SH-EMAT의 신호 수신을 위한 광섬유 패브리-페롯 간섭계 센서의 적용 (Application of a Fiber Fabry-Pérot Interferometer Sensor for Receiving SH-EMAT Signals)

  • 이진혁;김대현;박익근
    • 비파괴검사학회지
    • /
    • 제34권2호
    • /
    • pp.165-170
    • /
    • 2014
  • 수평횡파(SH-wave)는 배관과 같은 박판 구조물에서 판파 모드로 전파하고 분산성이 단순하여 구조물의 건전성 평가에 유용하다. 전자기초음파탐촉자(EMAT)는 비접촉식으로 자석과 코일 배열을 조절하여 수평횡파를 발생하기 용이하다. 따라서 수평횡파 전자기초음파탐촉자(SH-EMAT)를 이용한 자동화 검사 시스템은 박판 구조물 건전성 감시에 매우 유용하다. 하지만 발전설비 또는 자동화 장비 등에서는 전자기노이즈가 상당히 많이 발생하고 EMAT 수신 센서는 전자기노이즈에 취약한 면이 있다. 광섬유 센서는 빛을 이용하여 전자기노이즈 환경에서 매우 유용하게 활용될 수 있다. 본 연구에서는 이러한 환경적 제약을 고려하여 광섬유 패브리-페롯 간섭계(FFPI)를 SH-EMAT으로 발생되는 초음파의 수신용 센서로 제안하였다. 평판시험편에서 SH-EMAT의 신호를 FFPI 센서를 이용하여 수신하고 이 신호에 대한 분석을 하였다. 제안된 FFPI 센서가 EMAT으로 가진된 SH wave의 신호를 명료하게 수신할 수 있음을 확인하였다.

실내조경에 사운드스케이프 음원 제공시 재실자의 음환경 만족도 향상에 관한 연구 (A Study on the Improvement of Occupants' Satisfaction for the Sound Environment When the Sound Source of Soundscape is Provided to the Interior Landscape)

  • 김호곤;국찬;백은선;백건종;송민정;신훈
    • 한국소음진동공학회논문집
    • /
    • 제21권4호
    • /
    • pp.307-314
    • /
    • 2011
  • This study was focused on the influence of soundscape provided to the interior landscape on the improvement of occupants' sound environment. When soundscape was provided to occupants together with the interior landscape rather than simply providing interior landscape, the occupants' satisfaction seemed to be improved. The most preferred sound source among the three sound sources was considered as the sound of the grasshopper. When both of the interior landscape and the landscape substances was provided, the adjectives with the average difference of more than 1 are "Vicissitudinous", "Elegant" and "Cheerful". When the interior landscape and the sound source were provided, such adjectives as "Vicissitudinous", "Complex" and "Cheerful" are extracted. When all the variables were provided, such adjectives as "Vicissitudinous", "Abundant" and "Cheerful" seem to show the difference of more than 1. Regarding "Vicissitudinous", it was possible to know that the average difference of more than 1.5 was the biggest. Regarding the relative values of the ${\alpha}$ wave and the ${\beta}$ wave for each part, it seemed that the highest ${\alpha}$ wave was generated on the left parietal lobe of P3, while the lowest ${\beta}$ wave was generated on the left and right frontal lobes of Fp1 and Fp2. According to this study, it was shown that the soundscape and the interior landscape seemed to influence the improvement of the occupants' sound environment.

저압 유도전동기에서 미소 부분방전 측정에 관한 연구 (A Study on the Measurement of Small Partial Discharges in a Low-voltage Induction Motor)

  • 길경석;송재용;서황동;황돈하;강동식;김용주
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.960-964
    • /
    • 2005
  • In this paper, we dealt with a partial discharge(PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage electric and electronic devices. The PD measurement system Is composed of a coupling network, a low noise amplifier, and associated electronics. h shielded box Is adopted to make a better measurement environment against around noise. A low cut-off frequency of the coupling network estimated by a sinusoidal wave input was 125 kHz (-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 10 mV/pC. In an application test oil a low-voltage three phase Induction motor (5 HP), we could detect 0.53 pC level of partial discharge at the applied voltage of AC 650 $V_{peak}$.

심전도 자동 진단 알고리즘 및 장치 구현(I) - YECGA 개요 (An implementation of automated ECG interpretation algorithm and system(I) - Introduction of YECGA)

  • 권혁제;정기삼;정성진;최석준;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.175-178
    • /
    • 1996
  • The purpose of this thesis is the propose of various signal processing algorithm for the ECG(electrocardiogram) and the design of realtime automated ECG analyzer feasible with these algorithms. The algorithms are composed of (1)filtering procedure fer the estimation and removal of baseline drift, 60Hz power line interference, and muscle artifacts (2)detection procedure of QRS complex and P wave (3)typification procedure for the pattern classification according to the morphologies (4) selection of representative beat, significant point and wave boundary decision procedure and (5) parameter extraction and diagnosis procedure. All verifications are carried out between the algorithms proposed in this paper and other algorithms already proposed by many researchers, for the objective comparison in each procedure. The efficiency of proposed algorithms are demonstrated with the aid of internationally validated CSE database and the performances of filtering procedure are compared on artificial noise signal as well as actual ECG signals with appropriate noise components. for the comparison on the performance of designed automated ECG analyzer, the diagnosis results were compared with ECG analyzer manufactered by Fukuda denshi in Japan.

  • PDF