• Title/Summary/Keyword: P-loop

Search Result 519, Processing Time 0.025 seconds

Theoretical Analysis of the Pressure Drop in Loop Heat Pipe by Sintered Porous Wick Structure (다공성소결윅구조에 따른 루프 히트파이프에서 압력손실의 이론적 분석)

  • Lee, K.W.;Lee, W.H.;Park, K.H.;Lee, K.J.;Chun, W.P.;Ihn, H.M.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1225-1230
    • /
    • 2004
  • In this paper, the pressure drops were investigated according to the sintered porous wick structure in loop heat pipe(LHP) by theoretical analysis. LHP has the wick only in evaporator for the circulation of working fluid, so utilizes porous wick structure which pore diameter is very small for large capillary force. This paper investigates the effects of different parameters on the pressure drops of the LHP such as particle diameter of sintered porous wick, wick porosity, vapor line diameter, thickness of wick and heating capacity. Working fluid is water and the material of sintered porous wick is copper. According to the these different parameters, capillary pressure, pressure drop in wick were analized by theoretical design method of LHP.

  • PDF

HOMOTOPY FIXED POINT SET OF THE HOMOTOPY FIBRE

  • Lee, Hyang-Sook
    • Bulletin of the Korean Mathematical Society
    • /
    • v.36 no.4
    • /
    • pp.755-762
    • /
    • 1999
  • Let X be a p-compace groyp, Y -> X bd a p-compact-subgroup of X and G -> X be a p-compact toral subgroup of X with $(X/Y)^{hG} \neq 0$. In this paper we show that the homotopy fixed point set of the homotopy fibre $(X/Y)^{hG}$ is $F_p$-finite.

  • PDF

Volumetric-Modulated Arc Radiotherapy Using Knowledge-Based Planning: Application to Spine Stereotactic Body Radiotherapy

  • Jeong, Chiyoung;Park, Jae Won;Kwak, Jungwon;Song, Si Yeol;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.94-103
    • /
    • 2019
  • Purpose: To evaluate the clinical feasibility of knowledge-based planning (KBP) for volumetric-modulated arc radiotherapy (VMAT) in spine stereotactic body radiotherapy (SBRT). Methods: Forty-eight VMAT plans for spine SBRT was studied. Two planning target volumes (PTVs) were defined for simultaneous integrated boost: PTV for boost (PTV-B: 27 Gy/3fractions) and PTV elective (PTV-E: 24 Gy/3fractions). The expert VMAT plans were manually generated by experienced planners. Twenty-six plans were used to train the KBP model using Varian RapidPlan. With the trained KBP model each KBP plan was automatically generated by an individual with little experience and compared with the expert plan (closed-loop validation). Twenty-two plans that had not been used for KBP model training were also compared with the KBP results (open-loop validation). Results: Although the minimal dose of PTV-B and PTV-E was lower and the maximal dose was higher than those of the expert plan, the difference was no larger than 0.7 Gy. In the closed-loop validation, D1.2cc, D0.35cc, and Dmean of the spinal cord was decreased by 0.9 Gy, 0.6 Gy, and 0.9 Gy, respectively, in the KBP plans (P<0.05). In the open-loop validation, only Dmean of the spinal cord was significantly decreased, by 0.5 Gy (P<0.05). Conclusions: The dose coverage and uniformity for PTV was slightly worse in the KBP for spine SBRT while the dose to the spinal cord was reduced, but the differences were small. Thus, inexperienced planners could easily generate a clinically feasible plan for spine SBRT by using KBP.

The Effect of Various Vitrification Methods on Developmental Rate of Mouse Pronuclear Embryos at Different Recovery Times (다양한 유리화 동결 방법이 각 시간대별 생쥐 전핵기 배아의 발달에 미치는 영향)

  • Kim, Ji-Chul;Seo, Byoung-Boo;Park, Sung-Baek;Kim, Jae-Myeoung
    • Journal of Embryo Transfer
    • /
    • v.27 no.1
    • /
    • pp.63-69
    • /
    • 2012
  • The objective of this study was to investigate the effectiveness of cryopreservation methods for the effect of various vitrification containers, such as EM-grid, OPS, or cryo-loop on the survival and developmental rate of vitrified mouse pronuclear embryos, and mouse cleavage embryo, at 21, 24, 27 and 30 hr after hCG injection. Post-thaw cleavage was similar among treatments, while the developmental rates of mouse blastocyst and hatched blastocyst were higher ($p$ <0.05) in 27 hr and 30 hr than 21 hr. The developmental rate of hatched blastocyst at vitrified cleavage mouse embryos in cryo-loop was significantly higher than vitrified pronuclear embryos of control group as well as EM-grid and OPS ($p$ <0.05). The developmental rate using cryo-loop was higher than EM-grid, but in case of OPS at vitrified cleavage and mouse pronuclear embryos, no significant difference was noticed. These results of our study show that the developmental rates of mouse embryos were unaffected by various vitrification containers, but in case of mouse embryos and hatched blastocysts at late vitrified pronuclear embryos the developmental rates were higher than early vitrified pronuclear embryos. Moreover, the developmental rate of hatched blastocyst at vitrified cleavage mouse embryos was significantly higher than vitrified pronuclear embryos. For better execution of this study, it will be mandatory to include improvement of vitrification containers, cryopreservation methods and conditions, higher survival rate, safe preservation, contamination and embryo loss.

Mitochondrial D-Loop Polymorphism and Microsatellite Instability in Prostate Cancer and Benign Hyperplasia Patients

  • Ashtiani, Zahra Ousati;Heidari, Mansour;Hasheminasab, Sayed-Mohammad;Ayati, Mohsen;Rakhshani, Naser
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3863-3868
    • /
    • 2012
  • In this study mitochondrial D-Loop variations in Iranian prostate cancer and benign prostatic hyperplasia (BPH) patients were investigated. Tumour samples and corresponding non-cancerous prostate tissue from 40 prostate cancer patients and 40 age-matched BPH patients were collected. The entire mtD-loop region (16024-576) was amplified using the PCR method and products were gel-purified and subjected to direct nucleotide sequencing. A total of 129 variations were found, the most frequent being 263A${\rightarrow}$G and 310T${\rightarrow}$C among both BPH and prostate cancer patients. Variation of 309 C${\rightarrow}$T was significantly more frequent in prostate cancer patients (P value<0.05). Four novel variations were observed on comparison with the MITOMAP database. Novel variations were np16154delT, np366G${\rightarrow}$A, np389G${\rightarrow}$A and 56insT. There was no correspondence between the different variations and the age of subjects. Considering that D-loop variations were frequent in both BPH and prostate cancer patients in our study, the fact that both groups had high average age can be a possible contributing factor. D-loop polymorphisms and microsatellite instability can influence cell physiology and result in a benign or malignant phenotype. Significantly higher frequency of 309 C${\rightarrow}$T variation in cancer patients is a notable finding and must be a focus of attention in future studies.

A Review on the RF Coil Designs and Trends for Ultra High Field Magnetic Resonance Imaging

  • Hernandez, Daniel;Kim, Kyoung-Nam
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.3
    • /
    • pp.95-122
    • /
    • 2020
  • In this article, we evaluated the performance of radiofrequency (RF) coils in terms of the signal-to-noise ratio (S/N) and homogeneity of magnetic resonance images when used for ultrahigh-frequency (UHF) 7T magnetic resonance imaging (MRI). High-quality MRI can be obtained when these two basic requirements are met. However, because of the dielectric effect, 7T magnetic resonance imaging still produces essentially a non-uniform magnetic flux (|B1|) density distribution. In general, heterogeneous and homogeneous RF coils may be designed using electromagnetic (EM) modeling. Heterogeneous coils, which are surface coils, are used in consideration of scalability in the |B1| region with a high S/N as multichannel loop coils rather than selecting a single loop. Loop coils are considered state of the art for their simplicity yet effective |B1|-field distribution and intensity. In addition, combining multiple loop coils allows phase arrays (PA). PA coils have gained great interest for use in receiving signals because of parallel imaging (PI) techniques, such as sensitivity encoding (SENSE) and generalized autocalibrating partial parallel acquisition (GRAPPA), which drastically reduce the acquisition time. With the introduction of a parallel transmit coil (pTx) system, a form of transceiver loop arrays has also been proposed. In this article, we discussed the applications and proposed designs of loop coils. RF homogeneous coils for volume imaging include Alderman-Grant resonators, birdcage coils, saddle coils, traveling wave coils, transmission line arrays, composite right-/left-handed arrays, and fusion coils. In this article, we also discussed the basic operation, design, and applications of these coils.

A study on the mold opening stroke according to the control method of the injection molding machine (사출성형기의 속도제어 방식에 따른 형개거리에 관한 연구)

  • Jung, Hyun-Suk;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.15 no.3
    • /
    • pp.56-61
    • /
    • 2021
  • The increase in automation facilities in the injection molding industry is a very important process control item. The most important item when constructing an unmanned machine using a take-out robot is the "mold opening stroke" of the mold. The injection molding machine control method is divided into hydraulic type and electric type, and there have been few studies on the mold opening distance according to the control method. In this study, the correlation was confirmed by increasing the injection speed to 20, 50, 80, and 100% for the three types of hydraulic control method, open loop and close loop, and electric control method. Through the experiment, the following results were obtained. (1) It can be seen that the reproducibility is excellent with the electric, close loop, and open loop control methods. (2) When the injection speed is set to 50%, the mold opening distance is 263.10~263.27 mm, which is the most reproducible. (3) As a result of ANOVA, both injection speed and mold opening distance showed a significant difference in the hydraulic control method (p<0.05), but it was verified through experiments that there was no significant difference in the electric control method. Based on these results, when electric control is selected rather than hydraulic control, the reproducibility of the mold opening distance is excellent, so it is thought that the taking-out robot can take the object out of the mold more safely.

Isolation of New Self-Cleaving Ribozymes with in vitro Selection

  • Cho, Bong-Rae;Lee, Young-Hoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.12
    • /
    • pp.2033-2037
    • /
    • 2005
  • In vitro selection was used to isolate $Mg^{2+}$-dependent self-cleaving ribozymes with cis-cleavage activity from a pre-tRNA library having 40-mer random sequences attached to 5'-end of E. coli $tRNA^{Phe}$. After 8 rounds of SELEX (Systematic Evolution of Ligands by Exponential Enrichment), RNA molecules which can self-cleave at the high concentration of $Mg^{2+}$ were isolated. The selected ribozymes can carry out the self-cleavage reaction in the presence of 100 mM $Mg^{2+}$ but not in 10 mM $Mg^{2+}$. The cleavage sites of the ribozymes are located at +3 and +4 of $tRNA^{Phe}$, compared with +1 position of 5'-end cleavage site of pre-tRNA by RNase P. New RNA constructs deprived of its D stem-loop, anticodon stem-loop, variable loop and T stem-loop, respectively showed the cleavage specificity identical to a ribozyme having the intact tRNA structure. Also, the new ribozyme fused with both a ribozyme and $tRNA^{Leu}$ showed the cleavage activities at the various sites within its sequences, different from two sites of position +3 and +4 observed in the ribozyme with $tRNA^{Phe}$. Our results suggest that the selected ribozyme is not structural-specific for tRNA.

Genetic Analysis of a Structural Motif Within the Conserved 530 Stem-Loop of Escherichia coli 16S rRNA

  • Szatkiewicz Jin P.;Cho Hyun-Dae;Ryou Sang-Mi;Kim Jong-Myung;Cunningham Philip R.;Lee Kang-Seok
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.4
    • /
    • pp.569-575
    • /
    • 2006
  • The 530 stem-loop is a 46 nucleotide stem-loop structure found in all small-subunit ribosomal RNAs. Phylogenetic and mutational studies by others suggest the requirement for Watson-Crick interactions between the nucleotides 505-507 and 524-526 (530 pseudoknot), which are highly conserved. To examine the nature and functional significance of these interactions, a random mutagenesis experiment was conducted in which the nucleotides in the proposed pseudoknot were simultaneously mutated and functional mutants were selected and analyzed. Genetic analysis revealed that the particular nucleotide present at each position except 524 was not exclusively critical to the selection of functional mutants. It also indicated that basepairing interactions between the positions 505-507 and 524-526 were required for ribosomal function, and much weaker base-pairing interactions than those of the wild-type also allowed high ribosomal function. Our results support the hypothesis that the 530 pseudoknot structure may undergo a 'conformational switch' between folded and unfolded states during certain stages of the protein synthesis process by interacting with other ligands present in its environment.

Biological Removal of EG from Weight Loss Treatment Wastewater & Complex Dyeing Process Wastewater

  • Lee, Hyeon-Uk;Im, Dong-Jun
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.505-508
    • /
    • 2001
  • An microorganism able to degrade ethylene glycol(EG) was developed. Using this microorganism, biological treatment of ethylene glycol was studied in Erlenmeyer flasks and a laboratory scale stirred loop bioreactor. The removal efficiencies of ethylene glycol from synthetic wastewater were 91.6% ${\sim}$ 97.7% at $30^{\circ}C$ ${\sim}$ $40^{\circ}C$, and 96.3% ${\sim}$ 97.9% at initial pH 9 ${\sim}$ 11 respectively. Also the removal efficiencies of ethylene glycol were found to be more then 92% at initial ethylene glycol concentration of 300mg/L ${\sim}$ I400mg/L. In treatment of weight loss treatment wastewater using Erlenmeyer flasks, the removal efficiencies of ethylene glycol were 79.6%. 82.5%. 77.6%. and 71.3% at initial pH 9. 10. 11. and 12.4 after 11 days of reaction. Moreover in treatment of complex dyeing process wastewater. the residual ethylene glycol was not detected at the initial pH 10.0 and pH 11.3 after 4 days of reaction. When stirred loop bioreactor was used for removing ethylene glycol, the residual ethylene glycol was not detected after 108 hrs and 60 hrs of reaction in batch treatment of weight loss treatment wastewater and complex dyeing process wastewater.

  • PDF