• Title/Summary/Keyword: Oxygen Saturation

Search Result 540, Processing Time 0.031 seconds

Effect of Highly Concentrated Oxygen Administration on Addition Task Performance and Physiological Signals (고농도 산소가 덧셈과제 수행능력과 생리신호에 미치는 영향)

  • Chung, Soon-Cheol;Lim, Dae-Woon
    • Science of Emotion and Sensibility
    • /
    • v.11 no.1
    • /
    • pp.105-112
    • /
    • 2008
  • This study investigated the effect of 40% oxygen administration on the addition task performance in three levels of difficulties and physiological signals. Ten male and female college students were selected as the subjects for this study. The experiment consisted of two runs: one was a addition task, with normal air (21% oxygen) administered and the other was with hyperoxic air (40% oxygen) administered. The experimental sequence in each run consisted of Rest1 (3 min), Task1 (1 min, one digit addition task), Task2 (1 min, two digit addition task), Task3 (1 min, three digit addition task), and Rest2 (4 min). Blood oxygen saturation and heart rate were measured throughout the five phases. The accuracy rates of the addition task were enhanced with 40% oxygen administration compared to 21% oxygen. Difference in the accuracy rates grew higher with the rise of difficulty. When 40% concentration oxygen is supplied, blood oxygen saturation increased and heart rate was decreased comparing to 21%. This study showed that the supply of high concentration oxygen increases blood oxygen saturation, which in turns accelerates brain activation resulting from cognitive process and enhances arithmetic abilities. Particularly when difficulty is high, demand for oxygen increases and, as a result, the effect of high concentration oxygen becomes more significant.

  • PDF

The Relationship between Oxygen Saturation and Color Alteration of a Compromised Skin Flap: Experimental Study on the Rabbit

  • Prasetyono, Theddeus O.H.;Adianto, Senja
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.505-509
    • /
    • 2013
  • Background The aim of this study was to collect important data on the time of oxygen saturation change in relation to skin flap color alteration using non-invasive pulse oximetry to evaluate its ability to provide continuous monitoring of skin flap perfusion. Methods An experimental study on the monitoring of blood perfusion of 20 tube-island groin flaps of 10 male New Zealand rabbits was performed using pulse oximetry. The animals were randomly assigned to one of two groups representing a blockage of either arterial or venous blood flow. The oxygen saturation change and clinical color alteration were monitored from the beginning of vessel clamping until the saturation became undetectable. The result was analyzed by the t-test using SSPS ver. 10.0. Results The mean times from the vessel clamping until the saturation became undetectable were $20.19{\pm}2.13$ seconds and $74.91{\pm}10.57$ seconds for the artery and vein clamping groups, respectively. The mean time of the clinical alteration from the beginning of vein clamping was $34.5{\pm}11.72$ minutes, while the alteration in flaps with artery clamping could not be detected until 2.5 hours after clamping. Conclusions The use of neonate-type reusable flex sensor-pulse oximetry is objective and effective in early detection of arterial and vein blockage. It provides real-time data on vessel occlusion, which in turn will allow for early salvaging. The detection periods of both arterial occlusion and venous congestion are much earlier than the color alteration one may encounter clinically.

Effects of $40\%$ Oxygen on 2-back Task: Changes of Cognitive Performance and Physiological Signals ($40\%$ 농도의 산소 공급이 2-back 과제 수행에 미치는 영향: 인지 능력 및 생리 신호의 변화)

  • Chung Soon-Cheol;Park Ha-Ra;Lee Bongsoo;Tack Gye-Rae;Yi Jeong-Han;Eom Jin-Sup;Sohn Jin-Hun
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.3
    • /
    • pp.189-197
    • /
    • 2005
  • In this study, changes in performance of 2-back task, blood oxygen saturation and heart rate due to $40\%$ concentration oxygen supply were observed. Five male $(25.8\pm1.3)$ and five female $(23.0\pm1.0)$ college students were nked to perform 2-bark task during two types of oxygen (concentration $21\%,\;40\%$) administration. The experimental sequence consisted of Rest1(1 min.), 0-back Task (1 min.), 2-bark Task (2 min.), and Rest2 (4 min.) and the physiological signals such as blood oxygen saturation and heart rate were measured throughout the stages. The experimental result showed that the performance increased significantly at $40\%'s$ concentration of oxygen rather than $21\%'s$, which shows oxygen supply has positive influence on cognitive performance. When $40\%$ concentration oxygen is supplied, the oxygen saturation in the blood increased and heart rate was decreased significantly comparing to $21\%$. It is Suggested that $40\%$ oxygen can stimulate brain activation bY increasing actual blood oxygen concentration in the process of cognitive performance, and hyperoxia makes heart rate decrease.

  • PDF

A Study on the Development of Sleep Monitoring Smart Wear based on Fiber Sensor for the Management of Sleep Apnea (수면 무호흡증 관리를 위한 섬유센서 기반의 슬립 모니터링 스마트 웨어 개발에 관한 연구)

  • Park, Jin-Hee;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.89-100
    • /
    • 2019
  • Sleep apnea, a medical condition associated with a variety of complications, is generally monitored by standard sleep polysomnography, which is expensive and uncomfortable. To overcome these limitations, this study proposes an unconstrained wearable monitoring system with stretch-fiber sensors that integrate with the wearer's clothing. The system allows patients to undergo examinations in a familiar environment while minimizing the occurrence of skin allergies caused by adhesive tools. As smart clothing for adult males with sleep apnea, long-sleeved T-shirts embedding fibrous sensors were developed, enabling real-time monitoring of the patients' breathing rate, oxygen saturation, and airflow as sleep apnea diagnostic indicators. The gauge factor was measured as 20.3 in sample 4. The maximum breathing intake, measured during three large breaths, was 2048 ml. the oxygen saturation was measured before and during breath-holding. The oxygen saturation change was 69.45%, showing a minimum measurable oxygen saturation of 70%. After washing the garment, the gauge factor reduced only to 18.0, confirming the durability of the proposed system. The wearable sleep apnea monitoring smart clothes are readily available in the home and can measure three indicators of sleep apnea: respiration rate, breathing flow and oxygen saturation.

Wearable oxygen saturation measurement platform for worker safety management (작업자의 안전관리를 위한 웨어러블 산소포화도 측정 플랫폼)

  • Lee, Yun Ju;Song, Chai Jong;Yoo, Sun Kook
    • Smart Media Journal
    • /
    • v.11 no.9
    • /
    • pp.30-38
    • /
    • 2022
  • It is important to grasp biometric data in real time for prompt action in the event of a safety accident at a work site where the risk of safety accidents exists. Among them, blood oxygen saturation is the most important factor in maintaining human life, so real-time oxygen saturation measurement and monitoring is necessary according to the situation as a preemptive response for worker safety management. By receiving real-time bio-signals from workers wearing health and life-risk protective clothing, and sharing and analyzing the worker's risk status in an external system, it is possible to diagnose the worker's current condition and efficiently respond to emergencies that may occur to the worker. In this paper, we propose a wearable oxygen saturation measurement platform technology that can monitor the risk of harmful gases and oxygen saturation of the wearer in real time and ensure the wearer's activity and safety in order to cope with emergency situations at the scene of an accident. If we overcome the limitations identified through the results of the proposed system later and apply improved biodata such as motion correction to the platform, we expect that it will be usable not only in hazardous gas environments, but also in hospitals and homes for emergency patients.

A Simple Design of an Imaging System for Accurate Spatial Mapping of Blood Oxygen Saturation Using a Single Element of Multi-wavelength LED (혈중 산소 포화도의 정확한 공간 매핑을 위한 다중 파장 LED 단일소자를 활용한 이미징 시스템 설계)

  • Jun Hwan Kim;Gi Yeon Yu;Ye Eun Song;Chan Yeong Yu;Yun Chae Jang;Riaz Muhammad;Kay Thwe Htun;Ahmed Ali;Seung Ho Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.450-464
    • /
    • 2023
  • Pulse oximetry, a non-invasive technique for evaluating blood oxygen saturation, conventionally depends on isolated measurements, rendering it vulnerable to factors like illumination profile, spatial blood flow fluctuations, and skin pigmentation. Previous efforts to address these issues through imaging systems often employed red and near-infrared illuminations with distinct profiles, leading to inconsistent ratios of transmitted light and the potential for errors in calculating spatial oxygen saturation distributions. While an integrating sphere was recently utilized as an illumination source to achieve uniform red and near-infrared illumination profiles on the sample surface, its bulkiness presented practical challenges. In this work, we have enhanced the pulse oximetry imaging system by transitioning illumination from an integrating sphere to a multi-wavelength LED configuration. This adjustment ensures simultaneous emission of red and near-infrared light from the same position, creating a homogeneous illumination profile on the sample surface. This approach guarantees consistent patterns of red and near-infrared illuminations that are spatially uniform. The sustained ratio between transmitted red and near-infrared light across space enables precise calculation of the spatial distribution of oxygen saturation, making our pulse oximetry imaging system more compact and portable without compromising accuracy. Our work significantly contributes to obtaining spatial information on blood oxygen saturation, providing valuable insights into tissue oxygenation in peripheral regions.

Effects of Open or Closed Suctioning on Lung Dynamics and Hypoxemia in Mechanically Ventilated Patients (기관 내 흡인 유형이 인공호흡기 대상자의 폐기능과 저산소혈증에 미치는 효과)

  • Lee, Eun Young;Kim, Su Hyun
    • Journal of Korean Academy of Nursing
    • /
    • v.44 no.2
    • /
    • pp.149-158
    • /
    • 2014
  • Purpose: This study was conducted to compare effects of open and closed suctioning methods on lung dynamics (dynamic compliance, tidal volume, and airway resistance) and hypoxemia (oxygen saturation and heart rate) in mechanically ventilated patients. Methods: This study was a cross-over repeated design. Participants were 21 adult patients being treated with endotracheal intubation using a pressure-controlled ventilator below Fraction of Inspired Oxygen ($FiO_2$) 60% and PEEP $8cmH_2O$. Data were collected at baseline and 1, 2, 3, 4, 5, and 10 minutes after suctioning. Data were analyzed using two-factor ANOVA with repeated measures on time and suctioning type. Results: Effects of the interaction between suction type and time were significant for oxygen saturation and heart rate but not significant for dynamic compliance, tidal volume, or airway resistance. Prior to performance of suctioning, tidal volume and oxygen saturation were significantly lower, but airway pressure and heart rate were significantly higher using the closed suctioning method as compared with the open suctioning method. Conclusion: For patients on ventilator therapy below $FiO_2$ 60% and PEEP $8cmH_2O$, open suctioning performed after delivery of 100% $FiO_2$ using a mechanical ventilator may not have as much negative impact on lung dynamics and hypoxemia as closed suctioning.

Changes in Respiratory Metabolism and Blood Chemistry of Olive Flounder Paralichthys olivaceus Exposed to Hypoxia (저산소에 노출된 넙치(Paralichthys olivaceus)의 호흡대사와 혈액의 화학적 변화)

  • Han, Ji-Do;Kim, Heung-Yun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.1
    • /
    • pp.45-52
    • /
    • 2016
  • This experiment investigated changes in metabolic rate (MO2), critical oxygen saturation (Scrit), and blood chemistry of olive flounder Paralichthys olivaceus exposed to progressive hypoxia and returned to normoxic water at 20°C. The normoxic standard metabolic rate (SMR) and routine metabolic rate (RMR) were 69.5-83.9 and 70.2-156.4 mg O2 kg-1h-1, respectively based on fish weight. Scrit was 31.0% dissolved oxygen (DO) at 20°C. After returning the fish to 70% DO following exposure to hypoxia (20% DO), MO2 increased two-fold compared to the normoxic SMR and then decreased into the range of the RMR with time. Blood PO2 and plasma lactate decreased significantly after exposure to hypoxia (20% DO) and then increased as ambient oxygen saturation decreased. Cortisol levels increased as ambient oxygen saturation decreased, but the levels decreased rapidly in the range of the normoxic control when the fish were returned to ambient water with 70% DO. Plasma glucose levels increased when the fish were returned to normoxic water after exposure to a progressively more hypoxic condition.

Effects of Oxygen Saturation Fluctuations on Retinopathy in Infants Younger than 30 Weeks' Gestational Age

  • Jeon, Chae Woo;Kim, Ji Su;Park, Bumhee;Lee, Jang Hoon
    • Neonatal Medicine
    • /
    • v.28 no.1
    • /
    • pp.7-13
    • /
    • 2021
  • Purpose: To evaluate the risk factors and effects of fluctuations in oxygen saturation on the occurrence and severity of retinopathy of prematurity (ROP). Methods: From January 1, 2013 to January 31, 2020, 260 patients hospitalized in the neonatal intensive care unit of Ajou University Hospital were retrospectively analyzed. Results: Sixty-six patients (25%) were diagnosed with ROP; of them 39 required treatment. In the multivariate regression analysis of ROP severity, the odds ratio (OR) of gestational age was 0.32 (95% confidence interval [CI], 0.22 to 0.47; P<0.0001). The OR of saturation of peripheral oxygen (SpO2) fluctuations at the 4th week after birth was 1.02 (95% CI, 1.02 to 1.12; P=0.041). Conclusion: SpO2 fluctuations in premature infants younger than 30 weeks' gestational age affects ROP severity, especially at the 4th week of life.

L'Oxygene Dissous dans une Lagone Eutrophisee a Salinite Variable (Etang de Berre;Mediterranee Nord-Occidentale) et dans les Eaux Douces et Marines Adjacentes (北西地中海에 위치하며 염도변화가 심한 부영양화 湖水 Etang de Berre 와 隣接淡水. 海水의 溶存酸素量 硏究)

  • 마르크;김기태
    • 한국해양학회지
    • /
    • v.21 no.4
    • /
    • pp.211-228
    • /
    • 1986
  • Variations of dissolved oxygen were studied for two years in two brackish lakes, Etang de Berre and Etang de Vaine related to the north-west Mediteranean Sea. The variations also were studied at the same time in nearby seawater, and in the four main tributaries of Etang de Berre. The distributions of dissolved oxygen values and their spatio-temporal variations were well matched with the characteristics of the water masses in different environments. The concentration of dissolved oxygen and the rate of oxygen saturation in seawater (Carry-le-Rouet) ranged from 5.0 to 6.0 ml.1$\^$-1/, and from 95 to 105%, respectively. The amount of dissolved oxygen in Etang de Berre oscillated between 0.17 and 11.43 ml.1$\^$-1/ with an average of 7.40ml1$\^$-1/.The rate of oxygen saturation oscillated between 2.9 and 168.3%. Annual values of the four tributaries are as follows (ml.1$\^$-1/ and %): Durance:8.68 and 113.6;Arc : 6.87 and 95.3;Touloubre: 6.87 and 91.0;Durancole;6.36 and 96.8 The data for the evolutions of dissolved oxygen in Etang de Berre on the period between 1965 and 1978 are presented. A rather good negative correlation links oxygen with temperatures.

  • PDF