• Title/Summary/Keyword: Overhead line

Search Result 455, Processing Time 0.031 seconds

Numerical characterization of real railway overhead cables

  • Sanchez-Rebollo, Cristina;Velez, Enrique;Jimenez-Octavio, Jesus R.
    • Wind and Structures
    • /
    • v.21 no.1
    • /
    • pp.105-117
    • /
    • 2015
  • This paper presents a numerical characterization of real railway overhead cables based on computational fluid dynamics (CFD). Complete analysis of the aerodynamic coefficients of this type of cross section yields a more accurate modelling of pressure loads acting on moving cables than provided by current approaches used in design. Thus, the characterization of certain selected commercial cables is carried out in this work for different wind speeds and angles of attack. The aerodynamic lift and drag coefficients are herein determined for two different types of grooved cables, which establish a relevant data set for the railway industry. Finally, the influence of this characterization on the fluid-structure interaction (FSI) is proved, the static behavior of a catenary system is studied by means of the finite element method (FEM) in order to analyze the effect of different wind angles of attack on the stiffness distribution.

The Mechanical and Electrical property changes of Overhead Conductor due to Forest Fire and Agents (산불과 소화약제에 노출된 가공송전선의 기계적 및 전기적 특성 변화)

  • Jang, Young-Ho;Kim, Byung-Geol;Kim, Shang-Shu;Han, Se-Won;Kim, Jin-Han
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.459-460
    • /
    • 2008
  • Forest Fire can cause a serious damage to overhead conductors. Therefore, the detailed investigation for the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is very much important to maintain transmission line safely. Oxidation of overhead conductor was increased with temperature and time(maximum time : 30min). Conductivity of Al conductor was decreased by Agents. The detailed will be given in the text.

  • PDF

A Study on an Improvement of Economical Efficiency for an Overhead Catenary Supporting Thin Walled Steel Pole by the Application of High-strength Steel (고강도 강의 적용을 통한 전차선로 강관 지지물 경제성 개선에 대한 연구)

  • Cho, Yong-Hyeon;Hwang, Min-Oh;Seok, Chang-Sung;Lee, Ki-Won
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.5 s.36
    • /
    • pp.582-587
    • /
    • 2006
  • Since Kyung-Bu High Speed Line has been introduced, a railway electrification has been proceeded rapidly. Therefore, in this study, a specification and application standard for an overhead catenary supporting thin walled steel pole using STKT590 material are proposed in order to improve an economical efficiency. To decide the specification, strength analysis, deflection analysis, deflection test and fracture test are performed. If the supporting structures using high strength materials such as STKT590 are installed, the advantages of cost by the materials price reduction and demand and supply are expected.

A Study on the Swing Analysis and Application of Suspension Insulating Sets and Jumper wires for 154kV and 345kV Overhead Lines (345kV이하 송전선로용 현수애자련 및 점퍼선의 횡진해석 및 적용연구)

  • Sohn, H.K.;Lee, E.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.116-118
    • /
    • 2001
  • It is important to determine of tower type whether suspension or tension tower in overhead transmission lines. When we select to tower type, we have need to check of swing angle for suspension string sets. And jumper wire of T/L in the strong wind area have to analysis of swing angle in order to clearance or length of tower arms. This paper is summarized the methods to calculate of swing angle for suspension string sets and jumper wires, and is calculated the swing angle. The calculated result have proposed to improved design specifications of overhead transmission line.

  • PDF

The Mechanical and Electrical behavior Changes of Overhead Conductor due to Forest Fire and Agents (소화약제 및 산불에 노출된 가공송전선의 전기적, 기계적 거동 변화)

  • Jang, Young-Ho;Kim, Byung-Geol;Kim, Shang-Shu;Han, Se-Won;Kim, Jin-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.242-247
    • /
    • 2009
  • Forest Fire can cause a serious damage to overhead conductors. Therefore, the detailed investigation for the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is very much important to maintain transmission line safely. Oxidation of overhead conductor was increased with temperature and time(maximum time : 30min). Conductivity of Al conductor was decreased by Agents. The detailed will be given in the text.

Implementation of Optimization of the Uplift Amount Measurement System of Overhead Contact Line (전차선 압상량 검출을 위한 최적 시스템 구현)

  • Park, Young;Lee, Kiwon;Park, Chulmin;Kwon, Sam-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.886-890
    • /
    • 2013
  • Uplift of contact wire and dynamic characteristics between pantograph and contact wire are key interaction performance of OCS (Overhead Catenary System). These two evaluation items are the approval criteria for the performance between OCS and pantograph. A telemetry system or DAQ (Data Acquisition) System based on wireless communication make it monitor a dynamic behavior which is measured directly in a 25 kv like parts. While permissible working time is too short time to install is too long. In this paper, it is described that optimization the telemetry measurement system for OCS and increasing accuracy, easy adaptation, and faster handling can be also achieved through the study.

Effects of an Overhead Ground Wire and Surge Arrester in the Railway due to Lightning Strokes (전차선로에서의 뇌격에 의한 가공지선과 피뢰기의 차폐효과)

  • Rim, Seong-Jeong;Han, Byung-Duk;Oh, Jung-Hwan;Yun, Sang-Yun;Kim, Jae-Chul;Chung, Yong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.468-470
    • /
    • 1999
  • Using the EMTP(Electro Magnetic Transient Program) for the analysis of lightning direct voltage on the railway system, the shielding effects of overhead grounding wire on the railway were studied quantitatively. Installation of overhead ground wire and sap-type arrester such as s-horn provides a 6.6kV HV distribution line with goof protection effects. Even severe lightning induced voltage were create, 6.6kV HV lines can be withstand.

  • PDF

Implementation of Image Monitoring system using High Speed Camera for Overhead Contact Wire (고속 카메라를 이용한 전차선 형상 검측 시스템 구현)

  • Cho, Hyeon-Young;Kwon, Sam-Young;Lee, Ki-Won;Park, Hyun-June;Na, Hae-Kyoung;Ko, Byeong-Hun;Park, Young
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1483-1487
    • /
    • 2006
  • In electric railway, image monitoring using high speed camera provides reliable, timely information of wear and geometry status, important in taking decisions for overhead contact wire maintenance. The contribution of this research is the development of a simple real-time monitoring system for use in measurement subsystem of contact wire and geometry of overhead contact wire in electric railway. The system has been consists of a high speed CMOS camera with resolution $1024{\times}1280$ pixels, line type laser source and PC-based image acquisition system with PCI Express slot. Vision acquisition software have been used in application programming interface for image acquisition, display, and storage with a frequency of sampling of 500 acquisitions per second.

  • PDF

Mechanical and Electrical Properties of Overhead Conductor due to Forest Fire (산불에 노출된 가공송전선의 기계적 및 전기적 특성 거동)

  • Kim, Byung-Geol;Jang, Young-Ho;Kim, Shang-Shu;Han, Se-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.1042-1048
    • /
    • 2008
  • Forest Fire can cause a serious damage to overhead conductors. Therefore, the detailed investigation for the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is very much important to maintain transmission line safely. Especially, this paper describes the changes of mechanical and electrical properties of flame exposed conductor. Overhead conductors temperature were almostly 55$\sim$65% of ambient temperature. Tensile Strength decreased according to incerase of Forest Fire temperature. The detailed will be given in the text.

The SAG Behavior of Overhead Conductor due to Forest Fire (산불에 의해 가열된 가공송전선의 이도거동)

  • Kim, Byung-Geol;Kim, Shang-Shu;Jun, Wan-Gi;Han, Se-Won;Kim, Jin-Han
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.516-517
    • /
    • 2007
  • Because forest fire can give a serious damage to overhead conductors, the thorough understanding about sag behavior of burned conductor is very important in maintaining the transmission line safely. Therefore, a systematic investigation was carried out by heating method. As the heating temperature increases, drastic change of tensile strength of Al wire due to the softening of Al wire occurred. When Al wire is exposed to the flame(about $800^{\circ}C$) during only 13 seconds, the remained tensile strength of Al wire showed under 90%. and then sag of overhead conductor become deteriorated. The detailed results will be given in the text.

  • PDF