• Title/Summary/Keyword: Over-voltage

Search Result 1,743, Processing Time 0.965 seconds

A Simplified Carrier-Based Pulse-Width Modulation Strategy for Two-level Voltage Source Inverters in the Over-modulation Region

  • Jing, Feng;He, Feng-You
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1480-1489
    • /
    • 2017
  • In this study, a carrier-based pulse-width modulation (PWM) method for two-level voltage source inverters in the over-modulation region is proposed. Based on the superposition principle, the reference voltage vectors outside the linear modulation boundary are adjusted to relocate to the vector hexagon, while their fundamental magnitudes are retained. In accordance with the adjusted reference vector, the corresponding modulated waves are respectively deduced in over-modulation mode I and II to generate the gate signals of the power switches, guaranteeing the linearity of the fundamental output phase voltage in the over-modulation region. Moreover, due to the linear relationship between the voltage vector and the duty ratios, the complicated sector identification and holding angle calculation found in previous methods are avoided in the modulated wave synthesis, which provides great simplicity for the proposed carrier-based over-modulation strategy. Experimental results demonstrate the effectiveness and validity of the proposed method.

A CV.CC Concurrent-Controled LED Converter (정전압.정전류 동시제어 LED 컨버터)

  • Mang, Chung-Yong;Lee, Won-Seok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.193-198
    • /
    • 2012
  • An LED converter used to operate an LED with high efficiency and long lifespan, activates an LED by keeping voltage and current constant. In spite of voltage drop by LED's overheating and over-voltage by damage of a power line and by circuit problem, most existing LED converters supply unchanged constant voltage and current to the LED. Eventually, LED is out of order because of over-voltage or over-current. To avoid the breakdown of an LED by over-voltage and over-current, we propose a new scheme which deactivate the PWM circuit in the event of over-current generating. The PWM circuit operates below the pre-determined level of current. While the over-voltage is generated in PWM circuit, the feedback circuit makes the PWM circuit stopped and therefore prevents LED from being damaged by over-voltage and over-current.

A study on the effects of a conducting metallic barrier on the surface creepage flash over discharge (연면방전에 미치는 도전층의 영향에 관한 연구)

  • Sung Kae Chung
    • 전기의세계
    • /
    • v.17 no.3
    • /
    • pp.7-28
    • /
    • 1968
  • When a insulator plate is inserted to the discharge path of a space discharge gap in which the field strength is not uniform, the spark voltage under the atmospheric pressure between the electrodes decreases or rises according to the position of the insulating plate. Also it is reported that if a metallic barrier plate is inserted to the discharge path of the same space discharge gap, similar variations of spark voltage are found. Speaking briefly, mensioned above are the spark voltage characteristics when an insulator or metallic barrier is inserted to the space discharge gap. Also some experimental results, concerning to the surface creepage flash over characteristics at the case when an insulator barrier is inserted to the discharge path of a surface creepage discharge gap, were reported by Peek. But up to now there are no reports on surface flash over voltage characteristics at the case when a metallic barrier is inserted to the surface creepage gap. In this study the effects of a conducting metallic barrier inserted to the path of a surface creepage discharge gap on the flash over voltage characteristics are investigated theoretically and experimentally, and got some important results, clearing the effects of the position and width of a conducting barrier is inserted, the surface flash over voltage characteristics appear as an Inverse N or W Characteristics. Such theoretical or experimental results may have some relation not only with the effects of dry belt and snow on suspension insulators, but also with the effects of dirty zone or water drops on the surface creepage flash over voltage.

  • PDF

Cost-effective Design of an Inverter Output Reactor in ASD application (전동기 과전압 억제용 OUTPUT REACTOR의 최적 설계)

  • 김한종;이근호;장철호;이제필
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.65-70
    • /
    • 1999
  • In this paper, the cost-effective design of output reactor which is used to suppress the over-voltage at the motor terminal in the Adjustable Speed Drives(ASD) application is proposed. In the elevator drive system, the power cable length is relatively shorter than other ASD applications and then the over-voltage at the motor terminal depends on the frequency characteristics of the output reactor at the over-voltage operating frequency. The over-voltage suppression mechanism of output reactor in ASD application is analyzed and the dominant parameters of output reactor for the over-voltage suppression are extracted. Using these parameters as the design values and considering the high frequency characteristics of iron core in the reactor, a new cost-effective structure of output reactor is proposed. Experimental results of the conventional reactor and the proposed reactor with a 15kW induction motor are given to verify the proposed scheme.

  • PDF

Abnormal Voltage Detection Circuit with Single Supply Using Threshold of MOS-FET for Power Supply Input Stage (FET 문턱전압 특징을 이용한 전원입력단용 단일전원 이상전원 검출회로)

  • Won, Joo Ho;Ko, Hyoungho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.107-113
    • /
    • 2016
  • All circuits in power input can only use the power provided by an external power supply. General electronic circuits use a secondary supply generated by a converter using a primary power in the power input. But protection and detection circuit for over-voltage circuit or under-voltage in power input have to use that input power because there is no other supply in power input. Therefore, previous electronics for satellite can protect only over-voltage using a zener diode, and can't detect over-voltage and under-voltage events, and provide a detection capability for over-voltage and under-voltage only for secondary supply. The proposed circuit can detect over-voltage and under-voltage using a single supply for the primary power input, +28V, with the threshold characteristics for MOS-FET, and the accuracy for a detection circuit is increased by 2.5%.

A Study of Particle-Initiated Breakdown Characteristics on a Spacer Surface for $SF_6$ GIS ($SF_6$ GIS용 스페이서 표면에서의 파티클에 의한 절연파괴 특성연구)

  • Kim, Jae-Ho;Lee, Yong-Gil;Kim, Dong-Eui;Lee, Sae-Hun;Kim, Jung-Dal
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1536-1539
    • /
    • 1994
  • The influence due to metallic particle contaminated on spacer surface is remarkable in the decreasing of dielectric strength in $SF_6$ GIS. In relation with this problem, We studied, AC flash-over voltage characteristics and breakdown mechanism are investigated under metallic particle initiated condition in $SF_6$ gas by varying the particle position, particle shape with a plane-plane electrode. The main results arc as follows 1. The small amount of the metallic particle in the gap do not make flash-over voltage to be influence, but the significant decrease of th flash-overed voltage is result in case of the big and long size of the metallic paraticle. 2. Influence of the flash-over voltage are lowest in the mid and are highest in the electrode of metallic particle position. 3. In case of the initiated metallie particle, The more the pressure are high, the more the recluced ratio of flash-over voltage are high. 4. The metallic particle shape which results in the reduced flash-over voltage forced the critical pressure to move in to the region of low pressure. 5. The existance of the metallic particle on the upper electrode side and high pressure make the decreasing ratio of flash-over voltage bigger than that of the ground side electrode.

  • PDF

Implementing a Dielectric Recovery Strength Measuring System for Molded Case Circuit Breakers

  • Cho, Young-Maan;Rhee, Jae-ho;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1752-1758
    • /
    • 2018
  • In a low-voltage distribution system, the molded case circuit breaker (MCCB) is a widely used device to protect loads by interrupting over-current; however the hot gas generated from the arc discharge in the interrupting process depletes the dielectric recovery strength between electrodes and leads to re-ignition after current-zero. Even though the circuit breaker is ordinarily tripped and successfully interrupts the over-current, the re-ignition causes the over-current to flow to the load again, which carries over the failure interruption. Therefore, it is necessary to understand the dielectric recovery process and the dielectric recovery voltage of the MCCB. To determine these characteristics, a measuring system comprised of the experimental circuit and source is implemented to apply controllable recovery voltage and over-current. By changing the controllable recovery voltage, in this work, re-ignition is driven repeatedly to obtain the dielectric recovery voltage V-t curve, which is used to analyze the dielectric recovery strength of the MCCB. A measuring system and an evaluation technique for the dielectric recovery strength of the MCCB are described. By using this system and method, the measurement to find out the dielectric recovery characteristics after current-zero for ready-made products is done and it is confirmed that which internal structure of the MCCB affects the dielectric recovery characteristics.

A study on the reliability test of Symmetric high voltage MOSFET under the extended source/drain length (Symmetric high voltage MOSFET의 extended source/drain 길이에 따른 전기적 특성의 고온영역 신뢰성 분석)

  • 임동주;최인철;노태문;구용서
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.309-312
    • /
    • 2003
  • In this study, the electrical characteristic of Symmetric high voltage MOSFET (SHVMOSFET) for display driver IC were investigated. Measurement data are taken over range of temperature (300K-400K) and various extended drain length. In high temperature condition(>400K), drain current decreased over 20%, and specific on-resistance increased over 30% in comparison with room temperature.

  • PDF

Measurement of HTS Stacked Tapes Properties under Over-Current Condition in External Magnetic Field (외부자계 인가시 적층 고온초전도선재의 과전류 통전특성 측정)

  • Lee, K.Y.;Lim, H.W.;Lee, H.J.;Cha, G.S.;Lee, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.909-911
    • /
    • 2002
  • Rises of current level at power applications, such as transformer, motor, power cable need for using stacked HTS tapes. In this paper, we measured rises of temperature and tap voltage in 4-stacked HTS tapes under over-current condition. We measured 4-stacked HTS tapes properties under over-current condition with a little temperature rise as well as a large temperature rise. Rises of temperature and tap voltage are measured by using E-type thermocouples and voltage taps, respectively. According to the results of measurement, rises of tap voltage under over-current condition with a large temperature rises depends on rises of temperature.

  • PDF

The Effect of Metallic Barrier on the Surface creeping Flash-over Voltage along the Insulation Materials (절연물의 연면섬락 전압에 미치는 금속 격벽의 영향)

  • Sung Kae Chung
    • 전기의세계
    • /
    • v.14 no.2
    • /
    • pp.8-13
    • /
    • 1965
  • It is expected that the impurities contained in a solid state insulation material will affect a considerable influence on its break-down voltage, dielectric loss, and insulation resistance. In this thesis, as a preliminary experimental research for the investigation described above, the effect of metalic barrier between the electrodes on the creepin flash over discharge voltage along the surface of a solid insulation material has been investigated, and got some interesting results. It was found that generaly the flash over voltage rises when a metalic barrier is located between the electrodes. The results of this investigation will be taken into account as an important components on the insulation design to prevent the creeping flash over discharge in insulators, bushings, and so on.

  • PDF