• Title/Summary/Keyword: Over discharge

Search Result 946, Processing Time 0.034 seconds

Analysis of Flow Characteristics in Upstream Channel depending on Water Gate Operation of Nakdan Multi Functional Weir (수문운영에 따른 낙단보 상류하도 흐름특성 해석)

  • Moon, Sang-Chul;Park, Ki Bum;Ahn, Seung-Seop
    • Journal of Environmental Science International
    • /
    • v.25 no.4
    • /
    • pp.491-504
    • /
    • 2016
  • This study, examines the flow characteristics of upstream channel depending on water gate operation of Nakdan Multi-fuctional weir. The specific purpose of this study are to simulate the variation of flow velocity depending on the operation of the weir using 1-dimensional hydraulic model, HEC-RAS, and compare it with observed velocity. For discharge conditions from $50m^3/s$ to $3,500m^3/s$, it is observed that the velocity of upstream channel is almost constant, whereas for probability flood discharge, the velocity and froude number are increased as the discharge values are increased. The velocity values for downstream boundary condition EL, 40.0 m are more decreased than those for EL. 40.5m. From comparison on the variation of water stage depending on water gate operation, it is observed that the stage values are almost constant for discharges below $300m^3/s$, whereas 5 cm to 20 cm for discharges over $700m^3/s$. Flow velocity at streamflow gauging station. Nakdong, is decreased by more than 875% after installing the weir. The results obtained from this study indicate that the velocity of upstream channel is decreased and the discharge and velocity of downstream channel are significantly varied after installing the weir.

Plasma Catalytic Methane Conversion over Sol-gel Derived Pt/TiO2 Catalyst in a Dielectric-barrier Discharge Reactor (DBD 반응기에서 솔-젤 법으로 제조된 Pt/TiO2 촉매를 이용한 메탄의 플라즈마 전환반응)

  • Kim, Seung-Soo
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.455-459
    • /
    • 2007
  • Plasma catalytic methane conversion was carried out in the presence of sol-gel derived $Pt/TiO_2$ catalysts within a dielectric-barrier discharge (DBD) reactor. Plasma-assisted reduction (PAR) was applied to reduce the prepared $Pt/TiO_2$ catalysts in DBD reactor, and prepared catalysts were successively reduced by PAR within 20 min irrespective of the Pt loading and the calcination temperature. The highest methane conversion was 40% when 3 wt% $Pt/TiO_2$ and 5 wt% $Pt/TiO_2$ catalysts were used after calcination at $600^{\circ}C$. The selectivities of light alkanes ($C_2H_6$, $C_3H_8$, $C_4H_{10}$) were highly increased when $Pt/TiO_2$ catalysts were used in DBD reactor.

Analysis of the Flow over Broad Crested Side Weir by Using Three-Dimensional Numerical Simulation (3차원 수치모의를 이용한 광정횡월류위어의 흐름특성 해석)

  • Kim, Dae-Geun;Kim, Yong-Geun
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.3
    • /
    • pp.277-286
    • /
    • 2007
  • In this study, we analyzed the flow characteristics in the wide-crested side weir of trapezoidal section by using a three dimensional numerical stimulation. From this study, as the Froude number increases in the main channel, the overflow discharge ratio and the discharge coefficient of lateral overflow tend to decrease. And it was also found that the increase of the lateral overflow reduces the channel discharge area in the downstream, and the size of recirculating zone is increasing in the opposite side of side weir. The stream-wise water surface on the side where the side weir is installed falls down rapidly in the weir starting point, gradually ascending, and rapidly rising at the end point. The reason why the water surface rapidly rises at the weir end point is because the weir end point hinders the flow.

Fabrication and Characterisitics of Al2O3-SiC Ceramic Composites for Electrostatic Discharge Safe Components (대전방지용 Al2O3-SiC 복합세라믹 소결체의 제조 및 특성)

  • Kim, Ha-Neul;Oh, Hyun-Myung;Park, Young-Jo;Ko, Jae-Woong;Lee, Hyun-Kwuon
    • Journal of Powder Materials
    • /
    • v.25 no.2
    • /
    • pp.144-150
    • /
    • 2018
  • $Al_2O_3-SiC$ ceramic composites are produced using pressureless sintering, and their plasma resistance, electrical resistance, and mechanical properties are evaluated to confirm their applicability as electrostatic-discharge-safe components for semiconductor devices. Through the addition of Mg and Y nitrate sintering aids, it is confirmed that even if SiC content exceeded 10%, complete densification is possible by pressureless sintering. By the uniform distribution of SiC, the total grain growth is suppressed to about $1{\mu}m$; thus an $Al_2O_3-SiC$ sintered body with a high strength over 600 MPa is obtained. The optimum amount of SiC to satisfy all the desired properties of electrostatic-discharge-safe ceramic components is obtained by finding the correlation between the plasma resistance and the electrical resistivity as a function of SiC amount.

Performance Analysis of a $CO_2$ Two-Stage Twin Rotary Compressor ($CO_2$ 2단 트윈 로타리 압축기 성능해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • Analytical investigation on the performance of a two stage twin rotary compressor for $CO_2$ heat pump water heater system has been carried out. A computer simulation program was made based on analytical models for gas compression in control volumes, leakages among neighboring volumes, and dynamics of moving elements of the compressor. Calculated cooling capacity, compressor input, and COP were well compared to those of experiments over the compressor speeds tested. For the operating condition of suction pressure of 3 MPa, and discharge pressure of 9 MPa, and compressor inlet temperature of $35^{\circ}C$, the compressor efficiency was calculated to be 80.2%: volumetric, adiabatic, and mechanical efficiencies were 88.3%, 93.2%, and 92.7%, respectively. For the present compressor model, volumetric and adiabatic efficiencies of the second stage cylinder were lower by about $6{\sim}7%$ than those of the first stage mainly due to the smaller discharge port at the second stage. Parametric study on the discharge port size showed that the compressor performance could be improved by 3.5% just by increasing the discharge port diameter by 20%.

Analysis of Tidal Effect on the Han and Imjin River (한강 및 임진강의 조위영향분석)

  • Kim, Sang-Ho;Kim, Won;Choi, Hung-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.2
    • /
    • pp.301-313
    • /
    • 2003
  • Effects of the West sea tide to the flow of the Han and Imjin river during floods and normal seasons was analyzed by the hydraulic model. Tidal effect diagrams which represent the inter-relationships between flow of two livers and tide of Wolgot were developed using the results of analysis. At Jamsu and Hangang bridge, the stage rise due to the tide can be reached about 2m at maximum when the discharge of Paldang dam is less than 5,000cms, and the stage rise is very small when the discharge of Paldang dam is more than 15,000cms. In the Imjin river, the stage rise can be reached about 3.5m at maximum when the discharge is below 5,000cms, and can be neglected when the discharge is over 5,000cms.

Quantification of Realistic Discharge Coefficients for the Critical Flow Model of RELAP5/MOD3/KAERl (RELAP5 / MOD3/ KAERI의 임계유동모델을 위한 실제적 배출계수의 정량화)

  • Kwon, T.S.;Chung, B.D.;Lee, W.J.;Lee, N.H.;Huh, J.Y.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.701-709
    • /
    • 1995
  • The realistic discharge coefficient for the critical How model of RELAP5/AOD3/KAERI are determined for the subcooled and too-phase critical flow by assessments of nine MARVIKEN Critical flew Test(CFT). The selected test runs include a high initial subcooling and large nozzle aspect rat-io(L/D). The code assessment results show that RELAP5/MOD3/KAERI over-predicts the subcooled critical flow and under-predicts the two-phase critical flow. Using these result, the realistic discharge coefficients of critical flow models are quantified by an iterative method. The realistic discharge coefficients are determined to be 0.89 for the subcooled critical How and 1.07 for the two-phase critical flow, and the associated standard deviations are 0.0349 and 0.1189, respectively. The results obtained from this study can be applied to calculate the realistic system response of Large Break Loss of Coolant Accident and to evaluate the realistic Emergency Core Cooling System performance.

  • PDF

Analyses on the Mean Length of Stay of and the Income Effects due to Early Discharge of Car Accident Patients at General Hospital (3차 병원에 입원한 교통사고환자의 평균 재원기간과 조기퇴원시의 수입증대효과 분석연구)

  • Ryu, Ho-Sihn
    • Research in Community and Public Health Nursing
    • /
    • v.10 no.1
    • /
    • pp.70-79
    • /
    • 1999
  • This study attempts to encourage the development of a rehabilitation delivery system as a substitute service for hospitalization such as a community based intermediate facility or home health care. We need substitute services for hospitalization to curtail the length of stay for inpatients due to car accidents. It focused on developing an estimation for early discharge based on a detailed statement of treatment from medical records of 109 inpatients who were hospitalized at General Hospital in 1997. This study has three specific purposes: First, to find the mean length of stay and mean medical expenditure. Second, to estimate the mean of early discharge from the mean length of stay. Third, to analyize the income effect per bed from early discharge. In order to analyze the length of stay and medical expenditure of inpatients the author conducted a micro and macro-analysis with medical expenditure records. To estimate the early discharge we examined with a group of 4 experts decreases in the amount of treatment after surgery, in treatments, in tests, in drug methods. We also looked their vital signs, the start of ROM exercise, the time removel, a patient's visitations, and possible stable conditions. In addition to identifing the income effect due to an early discharge, the data was analyzed by an SPSS-PC for windows and Excell program with a regression analysis model. The research findings are as follows: First, the mean length of stay was 47.56 days, but the mean length of stay due to early discharge was 32.26 days. The estimation of early discharge days was shown to depend on the length of stay. The longer the length of stay, the longer the length before discharge. For example, if the patient stayed under 14 days the mean length of stay was 7.09 while an early discharge was 6.39, whereas if the mean length of stay was 155.73, the early discharge time was 107.43. The mean medical expenditure per day of car accident patients was found to be 169,085 Won, whereas the mean medical expenditure per day was shown to be in a negative linear form according to the length of stay. That is the mean expenditure for under 14 days of stay was 303,015 Won and the period of the hospitalization of 15 days to 29 days was 170,338 Won and those of 30 days to 59 days was 113,333 Won. The estimation of the income effect due to being discharged 16 days was around 2,350,000 Won with a regression analysis model. However, this does not show the real benefits from an early discharge, but only the income increasing amount without considering prime medical cost at a general hospital. Therefore, we need further analysis on cost containments and benefits incending turn over rates and medical prime costs. From these research findings, the following suggestions have been drawn, we need to develop strategies on a rehabilitation delivery system focused on consumers for the 21st century. Varions intermediate facilities and home health care should be developed in the community as a substitute for shortening the length of stay in hospitals. In home health care cases, patients who want rehabilitation services as a substitute for hospitalization in cooperation with private health insurance companies might be available immediately.

  • PDF

A Preliminary Study for Expending of Hospital-Based Horne Health Care Coverage - Focused on Accident Inpatients Who has the Workers Compensation Insurance - (병원중심 가정간호사업 관리대상범위 확대를 위한 기초연구)

  • Lee, Sook-Ja;Lee, Jin-Kyung;Ryu, Ho-Sihn
    • Journal of Home Health Care Nursing
    • /
    • v.6
    • /
    • pp.5-18
    • /
    • 1999
  • This study was attempt to encourage for developing on rehabilitation delivery system and programs as a substitute service instead of hospitalization for accident patients at work, such as hospital based home health care nursing service. It needs vary substitutes service of hospitalization to curtail the length of stay for inpatients who were hospitalized with workers compensation insurance. It focused on developing an estimation of early discharge day of accident inpatients based on a detail statement of treatment for 115 inpatients who were hospitalized at General Hospital in 1997. This study has four specific purpose as follows. First, to find out the status of health service utilization. Second, to estimate the early discharge days and income increasing effect based on the early discharge for those patients. Third, to identify the factors to affect total medical expenditure and the length of stay for those inpatients. Forth, to figure out the need of utilizing home health care nursing service for accident patients. In order to analyze of the length of stay and medical expenditure for inpatients who were hospitalized due to the accident, the authors conducted with micro-analysis and macroanalysis from medical records and medical expenditure records. Micro-analysis was done by nominal group discussion of 4 expertise with the critical criteria. such as a decrease in the amount of treatment after surgery, treatments, tests, drugs and changes in the tests consistency, drug methods, vital signs, start of ROM exercise, doctor's order, patient's outside visiting ability, stable conditions. In addition to identify affected variables for medical expenditure. the length of stay and income effect due to early discharge day, the data was analyzed with multiple regression analysis and linear regression analysis model by SPSS-PC for windows and Excell program. Results of this study as follows. First, the mean length of stay was 37.1 days, whereas the mean length of stay due to early discharge was 28.2 days at the hospital. The estimation of early discharge days were shown that depends on the length of stay. The longer length of stay, the longer length of early discharge days, such as under 7 days length of stay patients was to estimated the mean length of stay was 4.9 days and early discharge days was 4.6. whereas the mean length of stay was 122.6 days and early discharge days was 92.0 respectively. The mean medical expenditure per day were found to be 133.409 Won. whereas the mean medical expenditure per day was shown negative linear trends according to the length of stay at the hospital. The estimation results of the income effect due to 11 early discharge days per bed was around 2,150,000 won. However, it means not the real benefits from early discharge, but the income increasing amount without considering medical prime cost in general hospital. Therefore, it needs further analysis on the cost containments and benefits under the considering as well turn over rates per bed as the medical prime costs. The length of stay was most significant and the sign was positive to the total medical expenditure, as expected. Surgery and patient's residential area also an important variable in explaining medical expenditure. The level of complications was most significant variable in explaining the length of stay. The level of the needs on horne health care nursing service which can be used for early discharge accident patients were shown very high. The needs distribution varied from 65.5% of patients and 88.9% of caregivers, to 96.4% of doctors, and 99.1% of nurses. In addition horne health nurse responded that they can be managed the accident inpatients from early discharge. From these research findings. the following suggestions has been drawn it needs to develop strategies on rehabilitation delivery system in order to focused on consumer's side which is planned for 21 century health policy in Korea. Vary intermediate facilities and horne health care would have been developed in the community based for comprehensive rehabilitation services as a substitutes of hospitalization for shortening the length of stay of hospitalizations. In hospital based horne health care nursing service, it's available immediately to utilize for the patients who wanted rehabilitation services as a substitutes of hospitalization under the cooperations with workers compensation insurance company.

  • PDF

Implementing a Dielectric Recovery Strength Measuring System for Molded Case Circuit Breakers

  • Cho, Young-Maan;Rhee, Jae-ho;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1752-1758
    • /
    • 2018
  • In a low-voltage distribution system, the molded case circuit breaker (MCCB) is a widely used device to protect loads by interrupting over-current; however the hot gas generated from the arc discharge in the interrupting process depletes the dielectric recovery strength between electrodes and leads to re-ignition after current-zero. Even though the circuit breaker is ordinarily tripped and successfully interrupts the over-current, the re-ignition causes the over-current to flow to the load again, which carries over the failure interruption. Therefore, it is necessary to understand the dielectric recovery process and the dielectric recovery voltage of the MCCB. To determine these characteristics, a measuring system comprised of the experimental circuit and source is implemented to apply controllable recovery voltage and over-current. By changing the controllable recovery voltage, in this work, re-ignition is driven repeatedly to obtain the dielectric recovery voltage V-t curve, which is used to analyze the dielectric recovery strength of the MCCB. A measuring system and an evaluation technique for the dielectric recovery strength of the MCCB are described. By using this system and method, the measurement to find out the dielectric recovery characteristics after current-zero for ready-made products is done and it is confirmed that which internal structure of the MCCB affects the dielectric recovery characteristics.