• Title/Summary/Keyword: Over Voltage Protection

Search Result 132, Processing Time 0.025 seconds

Design of Adaptive Current Control Circuits for LEDs (LED 정전류 적응 제어 회로 설계)

  • Lee, Kwang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.8-14
    • /
    • 2015
  • An effective way to ensure that LEDs produce wanted light output is to use a current driving topology, because the brightness of LEDs is directly related to their current. However, this topology may lead to the lifetime shortening of a illumination system because over-currents may flow through non-damaged LEDs in case some LEDs are damaged. This paper presents an adaptive current control circuits for LEDs, which protect LEDs in a good state by limiting the driving currents according to the number of damaged ones. The proposed control circuits consist of a simple constant-current driver and a micro-controller which monitors the voltage of LED array without any auxiliary current sensors for fault diagnosis. And the driving current is automatically controlled into 6-levels according to the number of failures.

Development of Safety Assessment for Hydrogen Fuel Cell Vehicle (수소연료전지 자동차 안전성 평가기술 개발)

  • Yong, Gee Joong;Lee, Kwang Bum
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.500-508
    • /
    • 2014
  • In the ongoing debates over the need to identify new sources of energy and to reduce the emissions of greenhouse gases. Hydrogen has emerged as one of the most promising alternatives due to its emissions from the vehicle being virtually zero. The governments have identified the development of regulations and standards as one of the key requirements for commercialization of HFCV. Regulations and standards will help overcome technological barriers to commercialization. The development of Global Technical Regulation (GTR) for HFCV occurred under the World Forum for Harmonization of Vehicle Regulations. Development of a technique for safety assessment of HFCV include four tasks, research for regulation system and policy, hydrogen safety, vehicle operation safety and protection against high-voltage. The objective is to establish a technique for safety assessment and amend safety standards for HFCV and consequently reflect research results to vehicle management policy. We devised safety standards and evaluation techniques with regard to high-pressure gas and high voltage of hydrogen fuel cell vehicle. KMVSS for HFCV was amended to June 10, 2014. including the results of the safety assessment technology for high-voltage and hydrogen characteristics.

Detection of High Impedance Fault Using Adaptive Neuro-Fuzzy Inference System (적응 뉴로 퍼지 추론 시스템을 이용한 고임피던스 고장검출)

  • 유창완
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.9 no.4
    • /
    • pp.426-435
    • /
    • 1999
  • A high impedance fault(HIF) is one of the serious problems facing the electric utility industry today. Because of the high impedance of a downed conductor under some conditions these faults are not easily detected by over-current based protection devices and can cause fires and personal hazard. In this paper a new method for detection of HIF which uses adaptive neuro-fuzzy inference system (ANFIS) is proposed. Since arcing fault current shows different changes during high and low voltage portion of conductor voltage waveform we firstly divided one cycle of fault current into equal spanned four data windows according to the mangnitude of conductor voltage. Fast fourier transform(FFT) is applied to each data window and the frequency spectrum of current waveform are chosen asinputs of ANFIS after input selection method is preprocessed. Using staged fault and normal data ANFIS is trained to discriminate between normal and HIF status by hybrid learning algorithm. This algorithm adapted gradient descent and least square method and shows rapid convergence speed and improved convergence error. The proposed method represent good performance when applied to staged fault data and HIFLL(high impedance like load)such as arc-welder.

  • PDF

Cathode Side Engineering to Raise Holding Voltage of SCR in a 0.5-㎛ 24 V CDMOS Process

  • Wang, Yang;Jin, Xiangliang;Zhou, Acheng;Yang, Liu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.6
    • /
    • pp.601-607
    • /
    • 2015
  • A set of novel silicon controlled rectifier (SCR) devices' characteristics have been analyzed and verified under the electrostatic discharge (ESD) stress. A ring-shaped diffusion was added to their anode or cathode in order to improve the holding voltage (Vh) of SCR structure by creating new current discharging path and decreasing the emitter injection efficiency (${\gamma}$) of parasitic Bipolar Junction Transistor (BJT). ESD current density distribution imitated by 2-dimensional (2D) TCAD simulation demonstrated that an additional current path exists in the proposed SCR. All the related devices were investigated and characterized based on transmission line pulse (TLP) test system in a standard $0.5-{\mu}m$ 24 V CDMOS process. The proposed SCR devices with ring-shaped anode (RASCR) and ring-shaped cathode (RCSCR) own higher Vh than that of Simple SCR (S_SCR). Especially, the Vh of RCSCR has been raised above 33 V. What's more, their holding current is kept over 800 mA, which makes it possible to design power clamp with SCR structure for on chip ESD protection and keep the protected chip away from latch-up risk.

Study of KMVSS for Hydrogen Fuel Cell Vehicle (수소연료전지자동차에 대한 안전기준 고찰)

  • Yong, Gee Joong;Lee, Kwang Bum;Kwon, Hae Boung
    • Journal of Auto-vehicle Safety Association
    • /
    • v.6 no.2
    • /
    • pp.72-77
    • /
    • 2014
  • In the ongoing debates over the need to identify new sources of energy and to reduce the emissions of greenhouse gases. Hydrogen has emerged as one of the most promising alternatives due to its emissions from the vehicle being virtually zero. The governments have identified the development of regulations and standards as one of the key requirements for commercialization of hydrogen-fueled vehicles. Regulations and standards will helpful in overcoming technological barriers to commercialization. Developments of a technique for safety assessment of Hydrogen Fuel Cell Vehicle(HFCV) includes four tasks, research for regulation system and policy, hydrogen safety, vehicle operation safety and protection against high-voltage. The objective is to establish a technique for safety assessment and amend safety standards for HFCV and consequently reflect research results to vehicle management policy. We devised safety standards and evaluation techniques with regard to high-pressure gas and high voltage of hydrogen fuel cell vehicle. Korean Motor Vehicle Safety Standards(KMVSS) for HFCV was amended to June 10, 2014. including the results of the safety assessment technology for high-voltage and hydrogen characteristics.

Protection Performance Simulation of Coal Tar-Coated Pipes Buried in a Domestic Nuclear Power Plant Using Cathodic Protection and FEM Method (국내원전에 매설된 콜타르 코팅 배관의 음극방식과 FEM법을 이용한 방식성능 시뮬레이션)

  • Chang, H.Y.;Kim, K.T.;Lim, B.T.;Kim, K.S.;Kim, J.W.;Park, H.B.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.115-127
    • /
    • 2017
  • Coal tar-coated pipes buried in a domestic nuclear power plant have operated under the cathodic protection. This work conducted the simulation of the coating performance of these pipes using a FEM method. The pipes, being ductile cast iron have been suffered under considerably high cathodic protection condition beyond the appropriate condition. However, cathodic potential measured at the site revealed non-protected status. Converting from 3D CAD data of the power plant to appropriate type for a FEM simulation was conducted and cathodic potential under the applied voltage and current was calculated using primary and secondary current distribution and physical conditions. FEM simulation for coal tar-coated pipe without defects revealed over-protection condition if the pipes were well-coated. However, the simulation for coal tar-coated pipes with many defects predict that the coated pipes may be severely degraded. Therefore, for high risk pipes, direct examination and repair or renewal of pipes are strongly recommended.

Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line (22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

An Analysis of Influence Between the Power Feeding Line Insulation and Negative Rail Potential for the DC Ground Fault Protection in the Rubber Wheel System (고무차륜시스템에서의 지락보호를 위한 급전선로 절연과 부극전위와의 영향 분석)

  • Jung, Hosung;Shin, Seongkuen;Kim, Hyungchul;Park, Young;Cho, Sanghoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.577-583
    • /
    • 2013
  • We have analyzed influence of potential rise in negative bus, which caused by decrease of power feeding line insulation, upon protecting method of DC ground protection device which detecting potential rise between negative bus and ground in order to detect ground fault in the rubber wheel system. For this purpose, we proposed negative potential equation between negative bus and ground and calculated negative potential according to system condition changes by estimating power feeding line insulation changes in steel wheel system and rubber wheel system, and equalizing DC power feeding system when ground fault occurred. Also, in order to estimate negative potential of real system, we modeled the rubber wheel system, and simulated normal status, grounding fault occurrence and power feeding line insulation changes. In normal status, negative potential did not rise significantly regardless of vehicle operation. When ground fault occurred, negative potential rose up over 300V regardless of fault resistance. However, we also observed that negative potential rose when power feeding line insulation dropped down under $1M{\Omega}$. In conclusion, our result shows that in case of rubber wheel system unlike steel wheel system, relay will be prevented maloperation and insulation status observation can be ensured when ground over voltage relay will be set 200V ~ 300V.

A Study on the Operating Characteristics of Molded Case Circuit Breakers according to Temperature Rise (온도상승에 따른 배선용 차단기의 동작특성에 관한 연구)

  • Jung, Da-Woon;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.8-13
    • /
    • 2015
  • Molded Case Circuit Breakers (MCCBs) are typically used to provide over current protection for electrical safety caused by short circuit faults and overloads in indoor low voltage power systems. The MCCB automatically connects and disconnects loads from the electrical source when the current reaches a value and duration that will cause an excessive. However, the MCCB sometimes is not interrupted due to a malfunction, nuisance tripping, or in a fire. Ensuring electrical safety is very important in a indoor low voltage power system. This paper presents the operating characteristics of MCCBs according to a temperature rise from room temperature to 160 degrees Celsius delivered by a radiant panel heater. The ABS 54c(rated current: 30A) of the hydraulic magnetic trip type was used in the experiments. The signals of temperature, voltage, and current were measured using the high accuracy Signal Conditioning Extensions for Instrumentation (SCXI) measurement system with the LabVIEW program manufactured by National Instruments. The operating characteristics were measured as functions of current amplitude and ramp-up rate. The MCCB tripping time decreased as a result of increasing current amplitude and ramp-up rate under a temperature rise condition, because the temperature and level of the current are directly proportional to the tripping time. Additionally, an instantaneous operation was observed after 8 times of the rated current, and the MCCB began to melt a surface temperature of around 300 degrees Celsius of. The experimental results coincided well with the operating curve.

High Power Density Open-frame Type DC-DC Converter Module with Constant Current Control (정전류 제어 기능이 부가된 고전력밀도의 개방형 DC-DC 컨버터 모듈)

  • Lee Darl-Woo;Ahn Tae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.380-387
    • /
    • 2005
  • We report the performance of an open-frame type low-voltage high-current DC-DC converter module developed using an active clamp forward converter circuit and single ended rectifier. The converter module is designed with the specifications of an 3.3V output voltage, 30A output current, 100W output power and 36-75V input voltage. The synchronous rectifier is used to reduce the conduction loss at high current level and constant current control using precision PCB resistance is adapted to enhance the over current protection function in the system configuration. A prototype converter module is successfully implemented within 8mm height and quarter brick size (58x37mm) and recorded an $95W/in^3$ power density, 90.6$\%$ efficiency and 0.07$\%$ voltage regulation for the entire Input voltage range, thereby demonstrating its application potentials to future telecommunication electronics.