• 제목/요약/키워드: Over Temperature Protection

검색결과 124건 처리시간 0.023초

MOSFET Rds(on) 온도-저항 특성을 이용한 과열보호회로 모델링 (Over-Temperature Protection Circuit Modeling Using MOSFET Rds(on) Temperature-Resistance Characteristics)

  • 최낙권;이상훈;김형우;김기현;서길수;김남균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.3019-3021
    • /
    • 2005
  • In this paper we suggest a novel temperature detection method utilized in direct over-temperature protection circuit modeling. The suggested model detects temperature variation using Rds(on) characteristics of MOSFET, while the conventional methods are using extra devices such as a temperature sensor or an over-temperature detection transistor. The temperature-dependant MOSFET model is implemented using Spice ABM(Spice Analog Behavior Model). The direct over-temperature protection circuit was designed including it. We verified effectiveness of the temperature dependant Rds(on) model characteristics and performance of the direct over-temperature protection circuit on PSpice simulation

  • PDF

전력용 반도체 소자의 과열보호시스템 설계 및 구현 (Development and Implementation of an Over-Temperature Protection System for Power Semiconductor Devices)

  • 최낙권;이상훈
    • 융합신호처리학회논문지
    • /
    • 제11권2호
    • /
    • pp.163-168
    • /
    • 2010
  • 본 논문에서는 전력용 반도체 소자를 위한 과열보호시스템의 설계 및 구현에 관한 내용을 다룬다. 제안된 시스템은 전력용 반도체 소자의 온도를 검출하기 위해서 별도의 온도센서나 트랜지스터를 사용하는 기존의 방법과 달리 파워 MOSFET의 $R_{ds(on)}$ 특성만을 이용한다. 과열보호를 위한 제안된 방법은 IRF840 파워 MOSFET를 이용하여 성공적으로 시험되었다. 제안된 과열보호 알고리즘을 구현하기 위해 PIC 마이크로컨트롤러인 PIC16F877A 소자를 사용하였다. 내장된 10-bit A/D 변환기는 IRF840의 소스와 드레인 전압변화를 검출하기 위해 이용된다. 측정된 소스-드레인 간 전압으로부터 도출된 온도-저항 간의 관계식은 파워 MOSFET의 게이트 트리거 신호를 제어한다. 만약 검출된 온도 전압의 임계값이 설정된 임의의 보호온도 전압 값을 초과할 때 마이크로컨트롤러는 파워 MOSFET으로부터 트리거 신호를 제거시켜 파워 MOSFET이 과열되는 것을 방지한다. 실험결과는 제안된 시스템이 정확도 측면에서 1.5%의 오차 이내로 정확함을 보여주었다.

지능형 전력제어모듈을 위한 온도 모니터링 시스템 (Temperature Monitoring System of Power MOSFET for IPCM)

  • 최낙권;김기현;김형우;서길수;김남균
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권1호
    • /
    • pp.20-25
    • /
    • 2006
  • We suggest a novel temperature detection method utilized in temperature monitoring system. Suggested method detects temperature variation by using $R_{ds(on)}$ characteristics of MOSFET, while conventional methods are using extra devices such as a temperature sensor or an over-temperature detection transistor. For voltage detection between drain and source, 10 bits resolution ADC is needed. Therefore possible measurement signal range is about ten mV. If detected temperature's voltage exceed protection temperature's voltage then controller generates OT (Over Temperature) signal to stop MOSFET's trigger signal. Whole process of measurement is controlled by software. Experimental results show that the developed temperature monitoring system can provide the suitable temperature monitoring method and difference between detected and data sheet value of the suggested system is about $3\%$.

IPM의 과열직접보호 기능의 IC화를 위한 Spice modelling (Spice modelling of Direct Over Temperature Protection in Intelligent Power Module)

  • 서길수;김상철;김남균;김은동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1154-1156
    • /
    • 2003
  • 본 논문은 IPM의 구동부, 과열, 과전류, 단락 및 제어부의 부족전압 제어하는 IC의 설계중 Over-Temperature protection기능에 대한 것으로서 기존의 온도센서나 과열검출 Tr을 사용하지 않고, 온도에 따른 MOSFET의 Rds(on)변화를 검출하여 과열을 방지하는 Direct Over Temperature protection기능을 PSpice를 이용하여 modelling하고 simulation 한 결과에 대해서 기술하였다.

  • PDF

리튬 배터리 퓨즈 온도 보상에 따른 과전류 시퀀스 제어 알고리즘 설계 (Design of Over Current Sequence Control Algorithm According to Lithium Battery Fuse Temperature Compensation)

  • 송정용;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제32권1호
    • /
    • pp.58-63
    • /
    • 2019
  • Lithium-ion batteries used for IT, automobiles, and industrial energy-storage devices have battery management systems (BMS) to protect the battery from abnormal voltage, current, and temperature environments, as well as safety devices like, current interruption device (CID), fuse, and vent to obtain positive temperature coefficient (PTC). Nonetheless, there are harmful to human health and property and damage the brand image of the manufacturer because of smoke, fire, and explosion of lithium battery packs. In this paper, we propose a systematic protection algorithm combining battery temperature, over-current, and interconnection between protection elements to prevent copper deposition, internal short circuit, and separator shrinkage due to frequent and instantaneous over-current discharges. The parameters of the proposed algorithm are suggested to utilize the experimental data in consideration of battery pack operating conditions and malicious conditions.

3% NaCl용액중에 있어서 4340강의 부식거동과 과방식에 의한 수소포화거동에 미치는 인히비타의 영향 (The effect of inhibitors affecting to corrosion behaviors and hydrogen embrittlement behaviors due to over-propection of a 4340 steel in 3% NaCl solution)

  • 문경만;백태실;이상태
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.54-62
    • /
    • 1989
  • When some kinds of inhibitors, i.e. $1{\times}10{-3}mol/l$ arsenic trioxide, 0.2 mol/l 2-mercaptoethanol, 0.2mol/l thiourea were added to 3% NaCl solution, there were some considererable effects to decrease corrosion current density in natural potential condition and the effect fo solution temperature increasing corrosion rate was smaller than that of no addition to 3% NaCl solution. However the susceptibility of hydrogen embrittlement due to over-protection in case of cathodic protection was much greater than that of no addition, especially was the greatest in case of addition of 2-mercaptoethanol. Therefore adding inhibitors for anti-corrosion effect, it is suggested that selection of the optimum protection potential is important from the view point of prevention against hydrogen embrittlement due to over-protection in case of cathodic protection.

  • PDF

직물의 자외선 방어율에 따른 인체의 Vit. $D_3$ 합성과 온열생리적인 반응

  • 송명견;안령미;신정화
    • 한국의류학회지
    • /
    • 제23권7호
    • /
    • pp.980-986
    • /
    • 1999
  • This study was done to ivestigate the fabrics thatminimized harmfulness of UVB(ultraviolet B) and that might product Vit. {{{{ {D }`_{3 } ^{ } }} by UVB. Twelve female subjects wearing in three different types i.e fabric A(UVB 100% protection) fabric B(UVB 50% protection) and bikinii were exposed to outdoor environment (Air Temp : 25℃, 42% R,H Air velocity : 0.13m/s UV does :6KJ/m2) Blood samples were taken 24 hours before the after the experiment in order to examine concentration of vit.{{{{ {D }`_{3 } ^{ } }} in the blood. During the experiment axillary temperature skin temperature of 7 areas(forehead Chest Upper arm, Hand Thigh Lower leg, Foot) were measured. The more irradiated areas by UVB were the more the concentration of serum 25(OH){{{{ {D }`_{3 } ^{ } }} were significantly. Mean skin temperature was significantly low levekl in wearing the fabric of UVB 50% protection (p<0.001) Axillary temperature was significantly high level in wearing the fabric of UVB 50% protection (p<0.001). Therefore the fabric of UVB 50% protection intercepts the radiation and has advantage to give off body heat over other fabrics

  • PDF

전기다리미의 발화원인 판정에 관한 현상학적 고찰 (A Phenomenological Review on the Decision on the Cause of Ignition of Electric Iron)

  • 문용수;공하성;이종화
    • 대한안전경영과학회지
    • /
    • 제11권1호
    • /
    • pp.43-49
    • /
    • 2009
  • This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.

0.18um CMOS 공정을 이용한 강압형 DC-DC 컨버터 보호회로 구현 및 측정 (Implementation and Measurement of Protection Circuits for Step-down DC-DC Converter Using 0.18um CMOS Process)

  • 송원주;송한정
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.265-271
    • /
    • 2018
  • DC-DC buck converter is a critical building block in the power management integrated circuit (PMIC) architecture for the portable devices such as cellular phone, personal digital assistance (PDA) because of its power efficiency over a wide range of conversion ratio. To ensure a safe operation, avoid unexpected damages and enhance the reliability of the converter, fully-integrated protection circuits such as over voltage protection (OVP), under voltage lock out (UVLO), startup, and thermal shutdown (TSD) blocks are designed. In this paper, these three fully-integrated protection circuit blocks are proposed for use in the DC-DC buck converter. The buck converter with proposed protection blocks is operated with a switching frequency of 1 MHz in continuous conduction mode (CCM). In order to verify the proposed scheme, the buck converter has been designed using a 180 nm CMOS technology. The UVLO circuit is designed to track the input voltage and turns on/off the buck converter when the input voltage is higher/lower than 2.6 V, respectively. The OVP circuit blocks the buck converter's operation when the input voltage is over 3.3 V, thereby preventing the destruction of the devices inside the controller IC. The TSD circuit shuts down the converter's operation when the temperature is over $85^{\circ}C$. In order to verify the proposed scheme, these protection circuits were firstly verified through the simulation in SPICE. The proposed protection circuits were then fabricated and the measured results showed a good matching with the simulation results.