• Title/Summary/Keyword: Output characteristic

Search Result 1,217, Processing Time 0.028 seconds

A Study on the Output Characteristic of Vacuum Booster (진공배력장치 출력특성에 대한 연구)

  • Lee, C.T.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.110-116
    • /
    • 2009
  • In the present study, we proposed a simulation model of vacuum booster with AMESIM software to predict the output characteristic. And we performed the sensitivity analysis of output characteristic with main design parameters, such as diaphragm diameter. All of these parameters are main design parameters in the procedure of vacuum booster design. The simulation results of this paper offer qualitative information of vacuum booster output. Therefore, the simulation results of this paper will be used effectively for the design procedure of vacuum booster in the industrial field.

  • PDF

A study on the effect of inverter nonlinear characteristic on the flux estimation of an induction motor (인버터의 비선형 특성이 유도전동기의 자속 추정에 미치는 영향에 대한 연구)

  • Kim, Sang-Hoon;Kim, Tae-Suk
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.167-174
    • /
    • 2008
  • In this paper, the analysis on type effect of inverter output voltage distortion on the control of an induction motor is discussed. The inverter output voltage is distorted differently from the reference voltage owing to the inverter nonlinear characteristic. The inverter nonlinear characteristic results from the voltage drop, the inherent characteristic of the power semiconductor, and the dead time for preventing the short circuit of the inverter leg. This characteristic distorts the inverter output voltage and then, causes the motor flux estimation error. Although this characteristics do not significantly effect in the general-purpose induction motor control, but significantly effect on the low-speed operation of high performance motor control such as the sensorless vector control.

  • PDF

Output Characteristic Analysis of Small Hydropower Plant (소수력발전소의 출력특성 분석)

  • Park, Wan-Soon;Lee, Chul-Hyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.491-494
    • /
    • 2006
  • The output performance characteristics for surveyed sites were analyzed, using developed model. It consists of two main parts, the deciding flow duration characteristic of river and performance prediction model to estimate the output characteristics of small hydropower plants. As a result, it was found that the flowrate concerning with 25% of time ratio on flow duration curve can be selected to design flowrate of small hydropower plants, and the output characteristics of small hydropower plants having overflow dam are different from large scale hydropower plants.

  • PDF

Adaptive Design of IIR Digital Filters Using Output Error Method with Adaptive Compensator (적응 보상기를 가지는 출력오차 방법을 이용한 IIR 다지탈 필터의 적응적 설계)

  • 배현덕;이종각
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.9
    • /
    • pp.685-690
    • /
    • 1987
  • Adaptive design of IIR digiral filters using equation error method has been studied. In this paper, a design technique of IIR digital filters using output error method with adaptive compensator is presented. In computer simulation results, it is shown that flat response characteristic in pass-band, below-40[dB] attenuation characteristic in stop-band, sharf cut-off characteristic in transition-band, and phase characteristic is linearin pass-band.

  • PDF

The 90° hybrid Coupler having the same output power slope at two output ports (두 개의 출력단자에 동일한 출력 전력 기울기를 갖는 90° hybrid Coupler)

  • Park, Ung-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.85-88
    • /
    • 2016
  • Two output ports of $90^{\circ}$ hybrid-coupler are generally the same output power with $90^{\circ}$ phase difference. But, Two output ports of $90^{\circ}$ hybrid-coupler must be the different output slope characteristic about frequency because of the different electrical length. In $90^{\circ}$ hybrid-coupler being the same power distribution, 3-dB power distribution at two output ports only exists near the center frequency. And, the output power difference between two output ports increases in accordance with the further away from the center frequency. This paper proposes $90^{\circ}$ hybrid-coupler being the similar output slope characteristic of two output ports in wideband to modify the ${\lambda}/4$ transmission line of $35-{\Omega}$ characteristic impedance between input port and output port near input port. The power difference between two output ports of the proposed circuit is below 0.2dB over 20% bandwidth of the center frequency in ADS(advanced Design System).

  • PDF

Fabrication and electrical characteristic analysis of poly-Si TFT with lateral body (측면 기판 단자를 갖는 다결정 실리콘 박막 트랜지스터의 제작과 전기적 특성 분석)

  • Choi, H.B.;Yoo, J.S.;Kim, C.H.;Han, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1462-1464
    • /
    • 1998
  • Poly-Si TFT(Thin Film Transistor) is a electronic device that can be applied to the field of large area electronics such as AMLCD. We have fabricated the poly-Si TFT with lateral body terminal that is counter-doped body electrode and investigated the electrical characteristics of it. The lateral body terminal being short with s terminal, we have measured the transfer charac (Vg-ld) and the output characteristic (Vd-ld) fabricated devices. The measured result showe only that leakage current in OFF-state was re and Kink effect in ON-state was suppressed bu that in output characteristic curve the output Id was sustained constantly with the output v Vd in the saturation region.

  • PDF

Characteristic Impedances in Low-Voltage Distribution Systems for Power Line Communication

  • Kim, Young-Sung;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.29-34
    • /
    • 2007
  • The input and output impedances in a low voltage distribution system is one of the most important matters for power line communication because from the viewpoint of communication, the attenuation characteristic of the high frequency signals is greatly caused by impedance mismatch during sending and receiving. The frequency range is from 1MHz to 30MHz. Therefore, this paper investigates the input and output impedances in order to understand the characteristic of high frequency signals in the low voltage distribution system between a pole transformer and an end user. For power line communication, the model of Korea's low voltage distribution system is proposed in a residential area and then the low voltage distribution system is set up in a laboratory. In the low voltage distribution system, S parameters are measured by using a network analyzer. Finally, input and output impedances are calculated using S parameters.

A Study on the Electrical Characteristics of Photovoltaic Module Depending on Micro-Crack Patterns of Crystalline Silicon Solar Cell (결정질 태양전지의 Micro-crack 패턴에 따른 PV모듈의 전기적 특성에 관한 연구)

  • Song, Young-Hun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.407-412
    • /
    • 2012
  • This study investigated the process of thermal-induced growth of micro-crack developed at the crystalline solar cell using EL image, determined the output characteristic according to the pattern of micro-crack, analyzed the I-V characteristic according to the pattern of crack growth, and predicted the output value using simulation. The purpose of this study was, therefore, to investigate the process of thermal-induced growth of micro-crack developed at the early stage of PV module completion using EL image, to analyze the resulting decrement of output and predict the output value using simulation. It was observed that the crack grew increasingly by the thermal condition, and accordingly the lowering of output was accelerated. The output values of crack patterns with various direction were predicted using simulation, resulting in close I-V curve with only around 4% of error rate. It is considered that it is possible to predict the electric characteristic of solar cell module using only pattern of micro-crack occurred at solar cell based on our results.

Output Characteristic Analysis of Small Hydropower Plant (소수력발전소의 출력특성 분석)

  • Park Wan-Soon;Lee Chul-Hyung
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.81-85
    • /
    • 2006
  • The output performance characteristics for surveyed sites were analyzed, using developed model. It consists of two main parts, the deciding flow duration characteristic of river and performance prediction model to estimate the output characteristics of small hydropower plants. As a result, It was found that the flowrate concerning with 25% of time ratio on flow duration curve can be selected to design flowrate of small hydropower plants, and the output characteristics of small hydropower plants having overflow dam are different from large scale hydropower plants.

  • PDF

A Jitter Characteristic Improved PLL with RC Time Constant Circuit (저항-커패시턴스 시정수 회로를 이용하여 지터 특성을 개선한 위상고정루프)

  • An, Seong-Jin;Choi, Yong-Shig
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.2
    • /
    • pp.133-138
    • /
    • 2017
  • This paper presents a jitter characteristic improved phase locked loop (PLL) with an RC time constant circuit. In the RC time constant circuit, LPF's voltage is inputted to a comparator through small and large RC time constant circuits. The signal through a small RC time constant circuit has almost same loop filter output voltage. The signal through a large RC time constant circuit has the average value of loop filter output voltage and does as a role of reference voltage to the comparator. The output of the comparator controls the sub-charge pump which provide a current to LPF. When the loop filter output voltage increases, the sub-charge pump discharges the loop filter and decreases loop filter output voltage. When the loop filter output voltage decreases, the sub-charge pump charges the loop filter and increases loop filter output voltage. The negative feedback loop reduces the variation of loop filter output voltage resulting in jitter characteristic improvement.