• 제목/요약/키워드: Outer radius

검색결과 247건 처리시간 0.024초

고정된 바깥반경에 기준한 pin 핀의 최적화 (Optimization of a Pin Fin Based on Fixed Outer Radius)

  • 강형석;최수근
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.3-7
    • /
    • 2008
  • A cylindrical pin fin with variable fin base thickness is optimized based on fixed outer radius by using the one dimensional analytic method. Heat loss from the pin fin with fixed outer radius is presented as a function of the fin length. The ratio of in length for optimum heat loss to that for the maximum heat loss is listed. The maximum heat loss and effectiveness and the fin length for the optimum heat loss are presented as a function of fin base thickness and outer radius. One of the results presents the maximum effectiveness decreases rapidly first and then decreases slowly as the fin outer radius increases.

  • PDF

최대 열손실에 대한 열손실 비에 기준한 Pin 핀의 최적화 (Pin Fin Optimization Based on the Ratio of Heat Loss to the Maximum Heat Loss)

  • 강형석
    • 대한기계학회논문집B
    • /
    • 제32권11호
    • /
    • pp.817-823
    • /
    • 2008
  • A pin fin with variable fin base thickness is optimized based on the ratio of heat loss to the maximum heat loss using a two-dimensional analytic method. The temperature profile along the normalized radius position in the fin is presented. For fixed fin outer radius, the optimum heat loss, fin length and efficiency as a function of fin base thickness, outer radius, convection characteristic numbers ratio and ambient convection characteristic number are presented. One of the results shows that the effect of fin outer radius and ambient convection characteristic number on the optimum fin length is remarkable.

핀 바닥두께가 변하는 pin 핀의 해석 (Analysis of a Pin Fin with Variable Fin Base Thickness)

  • 강형석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.642-645
    • /
    • 2008
  • A pin fin with variable fin base thickness is analysed by using the one dimensional analytic method. Heat loss and fin thermal resistance are presented as a function of the fin base thickness, pin fin outer radius and convection characteristic numbers ratio. The relationship between the fin outer radius and fin base thickness for the same amount of heat loss is shown. One of the results indicates the fin thermal resistance decreases as the fin outer radius and/or convection characteristic numbers ratio increase whereas the fin thermal resistance is independent on the variation of fin base thickness.

  • PDF

박판의 Z-굽힘가공에서 외측 굽힘반지름 치수의 최소화(샤프에지) 가공법에 관한 연구 (A Research on the Processing Method to Minimize the Outer Radius(Sharp edge) in Sheet Metal Z-bending Work)

  • 윤재웅
    • 한국산학기술학회논문지
    • /
    • 제18권2호
    • /
    • pp.349-355
    • /
    • 2017
  • 프레스금형(press dies)에 의한 굽힘가공(bending work) 이라는 것은 평평한 블랭크(blank)를 필요로 하는 각도(角度)로 굽히는 것이다. 굽힘가공을 하면 굽혀진부분(flange)과 굽혀지지 않은 부분(web)으로 구분되며, 굽힘라인(bending line) 부분에는 굽혀진 각도(bending angle)와 굽힘반지름(bending radius)이 내측과 외측으로 성형된다. 이때, 내측 굽힘반지름의 크기는 제품의 재질별로 최소치수가 제시 된다. 제시된 최소치수 보다 작게 굽히면 절단면 굽힘부위에 덧살이 발생 하거나 외측 굽힘반지름 부위에는 균열(crack)이 생긴다. 굽힘가공에서의 외측 굽힘반지름은 자연적으로 생긴다. 그래서 외측 굽힘반지름 치수를 굽힘펀치와 다이블록으로 조정하면서 필요한 치수로 굽힐수 없다. 굽힘가공에는 V-굽힘, U-굽힘, Z-굽힘, O-굽힘, P-굽힘, 에지굽힘(edge bending), 트위스트굽힘(twist bending), 크림핑(crimping) 등이 있다.이 중에서 Z-굽힘은 굽힘라인이 2개로써 블랭크의 상면(上面)과 하면(下面)에 설정하여 상향(上向)굽힘이나 하향(下向)굽힘으로 작동되는 금형을 사용한다. Z-굽힘을 크랭크굽힘(crank bending) 이라고도 한다. 이런 구조의 금형으로 Z-굽힘가공을 하면 내측반지름은 표준치수로 굽혀진다. 표준치수라는 것은 굽힘가공에서 굽힐 수 있는 최소 굽힘반지름 치수로서 굽힘펀치의 각(角)반지름(Rp)를 뜻한다. 그런데 산업현장에서는 외측 굽힘반지름 치수를 굽힘펀치와 다이블록으로 굽힐수 없는 미세한 샤프에지(sharp edge) 형상인 매우 작은 치수(R=0.2mm)를 필요로하고 있는 바, 본 논문에서는 외측 굽힘반지름 치수를 0.2mm 이하로 굽힐수 있는 Z-굽힘가공 공법을 개발 하고자 하였다.

The evolution of dark matter halo profiles in a cosmological context

  • Park, Jinwoo;Choi, Hoseung;Yi, Sukyoung
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.73.3-73.3
    • /
    • 2017
  • Environment has a significant impact on the evolution of dark halo profiles. We used a cosmological N-body simulation based on WMAP5 cosmology to study environmental effects on halo profiles. Host haloes located in sparse regions are highly concentrated, and more massive haloes have higher concentration index. This is because mass accretion affects only the outer part of the halo and consequently increase the virial radius having no effect on the scale radius. Conversely, host haloes located in dense regions have low concentration index. This is because frequent mergers affect even the inner part of the halo. So, scale radius increases with the growth of virial radius. Evolutions of subhalo profiles are essentially different from those of host haloes because subhaloes undergo tidal stripping. The stripping begins once a subhalo approaches closer than ~3 virial radii of the host halo. During the stripping, the inner part of the subhalo keep following NFW profile, but the mass of the outer part gradually decreases. As a result, when the subhalo reaches the pericenter of its host, only about inner 30% of the subhalo follows the NFW profile.

  • PDF

속이 빈 원관에서 1차원적인 열전달 해석의 오차 (Errors in One-Dimensional Heat Transfer Analysis in a Hollow Cylinder Feedwater Pipe)

  • 강형석
    • 대한기계학회논문집B
    • /
    • 제20권2호
    • /
    • pp.689-696
    • /
    • 1996
  • A comparison is made of the heat loss from a hollow cylinder, computed using an one-dimensional analytic method and a two-dimensional separation of variables scheme. For a two-dimensional analysis, the temperature of the inner surface as a boundary condition can be varied along the length of the cylinder by varing the temperature variation factor, b. Comparisons of the heat loss from the hollow cylinder using these two methods are given as a function of non-dimensional cylinder length, the ratio of the outer radius to the inner radius, temperature variation factor and Biot number. The result shows that the value of the heat loss from the hollow cylinder obtained using the one-dimensional analytic method becomes close to the value given by the two-dimensional separation of variables scheme as the value of Biot number and the non-dimensional hollow cylinder length increase and as the ratio of the outer radius to the inner radius decreases.

경계요소법을 이용한 유압 엑츄에이터 실린더의 응력해석 (Analysis of the Stresses for Hydraulic Actuator Cylinders using Boundary Element Method)

  • 김옥삼
    • 동력기계공학회지
    • /
    • 제5권1호
    • /
    • pp.104-109
    • /
    • 2001
  • The stress distributions of hydranlic actuator cylinder tube acting in uniform inner pressure were analysed by the boundary element method(BEM). STKM13C tube was utilized for machine structural purposes model, its inner radius was 100 mm and outer radius was 140 mm. Axial length was semi-infinite and the isoparametric element of BEM was used. Radial and tangential stresses are maximum(-20.3 MPa and 52 MPa) at the inner radius and the minimum at the outer radius of the hydraulic actuator cylinders for an industrial systems. Stress diminution ratio was about 0.6 MPa/mm. And then coincidence between the simulation techniques as exact results(Lame' equation) and finite element method(FEM) is found to be fairly good, showing that the proposed analysis by BEM is reliable.

  • PDF

후벽 유압실린더 튜브의 탄소성 응력해석 (Elasto-plastic Stress Analysis for Hydraulic Cylinders Tube of Thick wall)

  • 김옥삼;김중현
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.647-652
    • /
    • 2000
  • This paper was utilized the STKM13C tubes for machine structural purposes model, inner radius was 100 mm and outer radios was 140 mm, axial length was semi-infinite and the isoparametric element was used. Radial, tangential and shearing stress occured the maximum stresses(-20, 52 and 26 MPa) at the inner radius and the minimum stresses at the outer radius. of the hydraulic actuator cylinders for an industrial systems. But negative signs have meaning compressive stress and stress diminution ratio was about 0.15 MPa/mm And then coincidence between the simulation and exact results(Lame' equation) is found to be fairly good, showing that the proposed analytical by BEM are reliable.

  • PDF

ERotating Bondi Accretion Flow with and without outflow

  • Han, Du-Hwan;Park, Myeong-Gu
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.52.4-53
    • /
    • 2020
  • It is less well known that the properties, especially the mass accretion rate, of accretion flow are affected by the angular momentum of accreting gas. Park (2009) found that the mass accretion rate \dot{m}, mass accretion rate in units of Bondi accretion rate, is inversely proportional to the angular momentum of gas λ, at the Bondi radius where gas sound speed is equal to the free-fall velocity and proportional to the viscosity parameter α, and also Narayan & Fabian (2011) found a similar relation, but the dependence of the mass accretion rate of the gas angular momentum is much weaker. In this work, we investigate the global solutions for the rotating Bondi flow, i.e., polytropic flow accreting via viscosity, for various accretion parameters and the dependence of the mass accretion rate on the physical characteristics of gas. We set the outer boundary at various radius r_{out}=10^3~10^5 r_{Sch}, where r_{Sch} is the Schwarzschild radius of the black hole. For a small Bondi radius, the mass accretion rate changes steeply, as the angular momentum changes, and for a large Bondi radius, the mass accretion rate changes gradually. When the accreting gas has a near or super Keplerian rotation, we confirm that the relation between the mass accretion rate and angular momentum is roughly independent of Bondi radius as shown in Park (2009). We find that \dot{m} is determined by the gas angular momentum at the Bondi radius in units of r_{Sch}c. We also investigate the solution for the rotating Bondi flow with the outflow. The outflow affects the determination of the mass accretion rate at the outer boundary. We find that the relation between the mass accretion and the gas angular momentum becomes shallower as the outflow strengthens.

  • PDF

Sensing Characteristics of Uncoated Double Cladding Long-period Fiber Grating Based on Mode Transition and Dual-peak Resonance

  • Zhou, Yuan;Gu, Zheng Tian;Ling, Qiang
    • Current Optics and Photonics
    • /
    • 제5권3호
    • /
    • pp.243-249
    • /
    • 2021
  • In this paper, the sensing characteristics of a double cladding fiber (DCF) long-period fiber grating (LPFG) to the surrounding refractive index (SRI) are studied. The outer cladding of the DCF plays the role of the overlay, thus, the mode transition (MT) phenomenon of DCF can be induced by etching the outer cladding radius instead of coating overlays. The response characteristics of the effective refractive index (ERI) of the cladding mode to the outer cladding radius are analyzed. It is found that in the MT range, the change rate of ERIs of cladding modes is relatively larger than that for other ranges. Further, based on the features of the mode transition region (MTR), the phase-matching curve of the 11th cladding mode is investigated, and the response of the DCF-LPFG to the SRI is characterized by the change of wavelength intervals between the dual peaks under different outer cladding radii. The numerical simulation results show that the SRI sensitivity is greatly improved, which is available to 3484.0 nm/RIU with the fitting degree 0.998 in the SRI range of 1.33-1.37. The proposed DCF-LPFG can provide new theoretical support for designing the DCF-LPFG refractive index sensor with excellent performances of sensitivity, linearity and structure.