• Title/Summary/Keyword: Outdoor Insulation

Search Result 138, Processing Time 0.028 seconds

Dielectric Properties for Surface Modified Micro-Nano Silica Composites of Cycloaliphatic Epoxy (지환식 에폭시/표면개질된 마이크로-나노실리카 콤포지트의 유전특성)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1840-1847
    • /
    • 2016
  • The surface of nanosilica and microsilica was modified in order to develop a high voltage insulation material for outdoor application. The modified silicas were well dispersed in an aliphatic cyclic epoxy resin. Dielectric properties were studied for 8 kinds of specimens: 1 kind of neat epoxy, 3 kinds of epoxy/microsilica composites, and 4 kinds of epoxy/microsilica/nanosilica composites. Complex dielectric constants were measured in the range of 10-2~1.2 Hz at room temperature.

TRACKING AND DIELECTRIC CHARACTERISTICS OF OZONE AGED SILICONE RUBBER USED FOR OUTDOOR INSULATI0N (옥외용 실리콘 고무의 장기 오존열화에 따른 내트랙킹 특성 및 유전특성 변화)

  • Lee, C.Y.;Kim, Y.H.;Lee, S.J.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1541-1543
    • /
    • 1996
  • This paper describes the results of characteristics on the tracking resistance, hydrophobicity and dielectric properties of silicone rubbers used for outdoor insulation with ozone ageing. The tracking and ozone ageing tests for this purpose ware made in according to IEC 587 and ASTM D 1149, respectively. Additionally, we investigated the surface structure of the silicone rubbers with FT-IR and SEM. From the test results, it is proven that the higher the degree of ozon ageing, the worse tracking characteristics.

  • PDF

옥외에서 사용되는 배전급 폴리머 현수애자의 오손특성에 관한 연구

  • Lee, Byung-Sung;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.340-345
    • /
    • 2001
  • Because they have superior insulating properties and lower in price than their ceramic equivalents, polymeric insulators have been used in outdoor insulators. But polymeric insulators mainly using in an heavy contamination area of outdoor could be easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we dismounted polymeric insulators adhered contaminant in the field, and evaluated its electrical characteristics, CA, and ESDD. We also manufactured slurry mixed by some kaolin and salt for the artificial contamination test and measured the degree of contaminant, AC leakage current for these contaminated samples. Consequently, the adhered contaminants to its surface is likely to be affected the performance of insulation.

  • PDF

Aging Evaluation of Polymer Insulator Housing with UV Exposure (자외선 노출에 따른 폴리머애자 하우징의 열화특성평가)

  • 이병성;한재홍;김찬영;한용희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.214-217
    • /
    • 1999
  • Polymeric composite insulators have been in use for outdoor insulation. However, our knowledge about their long-term performance in a outdoor environment is still very limited. Especially, these insulator are subjected to the environmental stress such as ultraviolet radiation. Hence, in this paper. the influence of UV radiation on the aging of the shed materials was evaluated. For the aging evaluation, these insulators studied by experiment methods such as contact angle measurement. oxidation induced time. SEM/EDX, FTRI-ATR, tracking test for the different insulator samples. With the increased UV exposure time, samples are shown to exhibit degradation comparable to those of new ones

  • PDF

A Combined Aging Test Facility for Evaluating an Aging Characteristics of Distribution Polymer Insulators (배전용 폴리머애자 열화특성 평가를 위한 복합열화 시험장치 구축)

  • Lee, Byung-Sung;Han, Jae-Hong;Kim, Chan-Young;Yoon, Tae-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1948-1950
    • /
    • 2000
  • Polymeric composite insulators have been in use for outdoor insulation. However, our knowledge about their long-term performance in an outdoor environment is still very limited. Especially, these insulators are subjected to the environmental stress such as ultraviolet radiation, electrical stress, mechanical load, etc.. Hence, in this paper, we simulated the factors having influence on aging of polymer insulators using the combined aging test chamber. In order to evaluate an aging characteristics with time, we measured leakage current on these insulators to make out the degree of aging.

  • PDF

The Evaluation of Flashover Characteristics of Polymer Insulators with Tracking Wheel Test (트래킹 휠 시험에 의해 열화된 폴리머애자의 섬락특성 평가)

  • Lee, Byung-Sung;Han, Jae-Hong;Yoon, Tae-Sang;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.82-85
    • /
    • 2000
  • Polymeric composite insulators are used for outdoor insulation. However, our knowledge about their long-term performance in an outdoor environment is still very limited. The electrical stress caused the surface of these insulators to become degradation. In order to evaluate the tracking resistance of polymer insulators, we performed the tracking wheel test which is recommended by CEA LWIWG-01. And the flashover voltage tests were conducted for understanding electrical characteristics after tacking wheel test. Also, these insulators are studied by characterization methods such as contact angle measurement, SEM, etc.

  • PDF

The variations of tracking resistance of outdoor Epoxy composites due to complex degradation (복합열화로 인한 옥외용 에폭시수지의 내트래킹성 변화)

  • Kim, T.Y.;Kim, K.M.;Lee, D.J.;Son, I.H.;Ka, C.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1614-1616
    • /
    • 1999
  • Epoxy resin has been used as matrix resin of advanced composites owing to ideally suitable properties and inherent physical and chemical properties for electrical and electronic insulation. In this paper, in order to evaluate the performance of epoxy composites for out door insulation, variations of tracking resistance were investigated on the complex ageing parameter. Also, IPN methods were introduced in order to improve performance for out door use. As a result, it was confirmed that tracking resistance were degraded with complex ageing parameters. But, it was confirmed that specimen of IPN structure have the better tracking resistance properties than SIN structure by moisture absorption aging.

  • PDF

Correlation Analysis between Climate and Contamination Degree through Multiple Regression Analysis (다중회귀 분석을 통한 기후 및 오손도 간의 상관관계 분석)

  • Kim, Do-Young;Lee, Won-Young;Shim, Kyu-Il;Han, Sang-Ok;Park, Kang-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.49-52
    • /
    • 2003
  • The performance of insulators under contaminated conditions is the underlying and the most factor that determines insulation design for outdoor applications, Among the contamination factors, The sea salt is the most dangerous factor, and the salt factor have closed relation with climatic conditions, such as wind, temperature, humidity and so on, Effect of these factors to insulation system is different of each other, and need to show the correlation by multiple regression analysis techniques. In this paper, predicted and analyzed equivalent salt deposit density (ESDD) by change climatic condition through multiple regression analysis.

  • PDF

A Study on the variations of tracking resistance of outdoor Epoxy composites due to moisture absorption aging (흡습열화에 따른 옥외용 에폭시 복합체의 내트래킹성 변화에 관한 연구)

  • 김탁용;이덕진;가출현;김명호;박창옥;김재환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.526-528
    • /
    • 1999
  • Epoxy resin has been used as matrix resin of advanced composites owing to ideally suitable properties and inherent physical and chemical properties for electrical and electronic insulation In this paper, in order to evaluate the performance of epoxy composites for out door insulation, variations of tracking resistance were investigated on the moisture absorption aging condition. Also, IPN methods were introduced in order to improve performance for out door use. As a result, it was confirmed that tracking resistance were degraded with boilling time. But, it was confirmed that specimen of IPN structure and KC-335 have the better tracking resistance properties than SIN structure by moisture absorption aging

  • PDF

Applied Technology of FRP Single Pole for Power Distribution Line (배전용 지지물의 FRP 적용 기술)

  • 박기호;조한구;한동희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.79-81
    • /
    • 2000
  • Outdoor insulation of overhead distribution lines with wood, concrete and steel pole has been safety under various environmental conditions including contamination, moisture condensation, rain and lightning overvoltages. In this paper introduce to FRP technology of the power distribution single pole. FRP pole has been used very much as high strength material for insulators because of its high strength and good insulation properties. In addition, FRP pole was made by filament winding method. In a filament winding process, a band of continuous resin-impregnated rovings or monofilaments is wrapped around a rotating mandrel and cured to produce axisymmetric hollow parts.

  • PDF