• 제목/요약/키워드: Out-of-field

검색결과 9,971건 처리시간 0.033초

Wind field simulation over complex terrain under different inflow wind directions

  • Huang, Wenfeng;Zhang, Xibin
    • Wind and Structures
    • /
    • 제28권4호
    • /
    • pp.239-253
    • /
    • 2019
  • Accurate numericalsimulation of wind field over complex terrain is an important prerequisite for wind resource assessment. In this study, numerical simulation of wind field over complex terrain was further carried out by taking the complex terrain around Siu Ho Wan station in Hong Kong as an example. By artificially expanding the original digital model data, Gambit and ICEM CFD software were used to create high-precision complex terrain model with high-quality meshing. The equilibrium atmospheric boundary layer simulation based on RANS turbulence model was carried out in a flat terrain domain, and the approximate inflow boundary conditions for the wind field simulation over complex terrain were established. Based on this, numerical simulations of wind field over complex terrain under different inflow wind directions were carried out. The numerical results were compared with the wind tunnel test and field measurement data for land and sea fetches. The results show that the numerical results are in good agreement with the wind tunnel data and the field measurement data which can verify the accuracy and reliability of the numerical simulation. The near ground wind field over complex terrain is complex and affected obviously by the terrain, and the wind field characteristics should be fully understood by numerical simulation when carrying out engineering application on it.

6 MV Linac을 이용한 Symmetric field와 Asymmetric field에서 Wedge factor의 비교 고찰 (Intercomparison of Wedge factor for Symmetric field and Asymmetric field used 6MV Linac)

  • 지연상;한재진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권2호
    • /
    • pp.57-60
    • /
    • 1999
  • Therapy equipment have taken progress for Cancer make use of Radiation for the normal tissue system make much of important for shielding. In modern times independent jaw setting to used equipment as possible make use of asymmetric field. Therefore, the asymmetric field be leave out of consideration wedge factor because of with used wedge for the most of part. These experimentation find out have an effect on the dosimetry of out put compared with of the difference between the symmetric field and asymmetic field for the wedge factor.

  • PDF

In-plane and out-of-plane waves in nanoplates immersed in bidirectional magnetic fields

  • Kiani, Keivan;Gharebaghi, Saeed Asil;Mehri, Bahman
    • Structural Engineering and Mechanics
    • /
    • 제61권1호
    • /
    • pp.65-76
    • /
    • 2017
  • Prediction of the characteristics of both in-plane and out-of-plane elastic waves within conducting nanoplates in the presence of bidirectionally in-plane magnetic fields is of interest. Using Lorentz's formulas and nonlocal continuum theory of Eringen, the nonlocal elastic version of the equations of motion is obtained. The frequencies as well as the corresponding phase and group velocities pertinent to the in-plane and out-of-plane waves are analytically evaluated. The roles of the strength of in-plane magnetic field, wavenumber, wave direction, nanoplate's thickness, and small-scale parameter on characteristics of waves are discussed. The obtained results show that the in-plane frequencies commonly grow with the in-plane magnetic field. However, the transmissibility of the out-of-plane waves rigorously depends on the magnetic field strength, direction of the propagated transverse waves, small-scale parameter, and thickness of the nanoplate. The criterion for safe transferring of the out-of-plane waves through the conducting nanoplate immersed in a bidirectional magnetic field is also explained and discussed.

현장인발시험을 통한 제거식 쏘일네일의 거동특성 평가 (Evaluation of Behavior Characteristics of Removable Soil Nails from the Field Pull-Out Tests)

  • 김홍택;강인규;이대형;정성필;박시삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.137-144
    • /
    • 1999
  • Recently a removable soil nail is demanded due to problems beyond of economical and engineering purpose. In this study removable soil nails are developed and field pull-out tests are carried out 16 times in order to analysis pull-out characteristics of the removable soil nail. For the spacing and the installed position of fixed socket, the length of the soil nail, and W/C ratio of cement grout in the removable soil nail, pull-out characteristics of pull-out tests are analyzed. From the pull-out characteristics of removable soil nails, it is found that the spacing of fixed socket and W/C ratio of cement grout are important design parameters.

  • PDF

현장인발시험을 통한 가압 그라우팅 쏘일네일의 장기 인발거동특성 (Long-term Behaviour Characteristics of Pressurized Grouting Soil Nails from the Field Pull-Out Tests)

  • 박시삼;이훈연;박주석;이홍규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.137-144
    • /
    • 2005
  • Recently a pressurized grouting soil nail is demanded due to problems beyond of economical and engineering purpose. In this study, a newly modified soil nailing technology named as the PGSN (Pressurized Grouting Soil Nailing) system is respected to reduced displacements of nails and increase of global slope stability. And effects of various factors related to the design of the PGSN system, such as the length of the soil nail, injected pressure and W/C ratio of cement grout in the pressurized grouting soil nail are examined throughout a series of the displacement-controlled field pull-out tests. Displacement-controlled field pull-out tests are performed in the present study and the volume of grouting are also evaluated based on the measurements. In addition, both short-term and long-term characteristics of pull-out deformations of the newly proposed PGSN system are analyzed and compared with those of the general soil nailing system by carrying out the stress-controlled field pull-out tests. From the pull-out characteristics of pressurized grouting soil nails, it is found that the effect of the length of the soil nail, injected pressure and W/C ratio of cement grout are important parameters.

  • PDF

현장인발시험을 통한 가압 그라우팅 쏘일네일의 변형특성 (Deformation Characteristics of the Pressurized Grouting Soil Nailing Systems from the Field Pull-out Tests)

  • 천병식;박주석;박시삼;정종주;공진영
    • 한국지반환경공학회 논문집
    • /
    • 제9권2호
    • /
    • pp.61-65
    • /
    • 2008
  • 본 연구에서는 PGSN(Pressurized Grouting Soil Nailing) 시스템이라는 가압 그라우팅 쏘일네일링 공법을 고안하였으며, 본 공법의 보강제의 길이변화 및 보강재의 변화 등의 설계인자에 따른 거동변화를 파악해 보기 위해 변위제어방식의 현장인발시험을 수행하였다. 본 연구에서 수행한 9차례의 현장인발시험에서 그라우트 주입비의 변화를 살펴 보기위해 계측을 수행하였으며, 단기거동특성을 평가하기 위해 일반 쏘일네일링 시스템과 비교해 보았다. 가압 그라우트 쏘일네일링 공법의 인발거동 특성을 통해, 중요한 설계인자인 주입압 및 그라우트 주입비 등의 영향을 살펴보았다. 시험 결과 가압효과에 따른 인발변형 특성은 중력식 그라우팅 쏘일네일에 비해 가압 그라우팅 쏘일네일의 경우 유발되는 변위량이 30~36% 정도 감소하였고, 보강재 변화에 따른 인발 특성을 살펴보면 이형철근에 비해 강관의 경우 유발되는 변위량이 31~32% 정도 감소하는 것으로 나타났다.

  • PDF

송전선로에서 전류와 자계의 상관관계 분석 (Analysis on the relation between electric current and magnetic field near transmission lines)

  • 조성배;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.3-5
    • /
    • 1997
  • The relation between electric current and magnetic field under three overhead transmission lines being operated was studied. It was examined for a difference each other in comparison with calculated value and measured value for current, magnetic field. With magnetic field equations made out, The magnetic field distribution around transmission lines had made to figure out with easy by load electric current value. Additionally, we are going to describe the distribution curve of magnetic exposure volume for KEPCO's T/L.

  • PDF

다철근 네일의 현장인발시험 및 수치해석 (Field Pull-out Test and Numerical Analysis for Multi-rebar Nail)

  • 전상수;김두섭;장양원
    • 한국지반공학회논문집
    • /
    • 제24권8호
    • /
    • pp.43-52
    • /
    • 2008
  • 본 연구에서는 단철근 네일과 다철근 네일의 인장강도를 조사하기 위해 단철근과 다철근 네일의 극한인발시험과 크리프시험을 수행하였다. 철근과 시멘트 그라우트의 부착력과 인장하중에 의해 유발된 마찰력, 하중전이 특성을 조사하였다. 단철근과 다철근 네일의 현장인발시험과 유한차분해석 프로그램의 하나인 $FLAC^{2D}$를 이용하여 얻은 결과를 분석하고 비교하였다. 다철근 네일의 현장인발시험결과 단철근 네일에 비해 인발파괴하중이 크고 하중전이가 큼을 알 수 있다.

신축공동주택에서 플러쉬아웃 실시에 따른 실내 VOCs 농도저감 효과에 관한 연구 (Reduction of Indoor VOCs' Concentrations using Flush-out in a Newly Built Apartment)

  • 박상인;박준석
    • 대한건축학회논문집:구조계
    • /
    • 제34권12호
    • /
    • pp.57-63
    • /
    • 2018
  • The purpose of this study was to confirm the effects of flush-out on the reduction of Volatile Organic Compounds(VOCs) concentration in newly built residential buildings. The field measurements were conducted in two complexes of multi-residential buildings which are located suburban areas of Seoul. About three samples of residential buildings were selected in the field measurements. Two samples, B and C, had been flush-out with outdoor air more than seven days. The sample A was maintained at same condition during the flush-out because of the comparison. The indoor concentrations of VOCs in the three samples were measured at three times, before, during, and after flush-out. From the field measurements, it was confirmed that two samples' indoor VOCs' concentrations were considerably decreased after the flush-out comapred with those of the sample A in which the flush-out was not conducted. The decreases of indoor VOCs concentrations were corresponding to about 50% ~ 92% of the concentrations of before. Through the reviews for the previous studies, it was also found that the reduction effects of the flush-out is similar with the those of the bake-out which were reported in the previous studies.

간편 시행쐐기법을 이용한 스파이럴 파이프 네일링 시스템의 안정해석 및 적용성에 관한 연구 (A Study on Application and Stability Analysis of Spiral Pipe Nailing System Using Simplified Trial Wedge Method)

  • 김홍택;박시삼;박성철;정성필
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.651-658
    • /
    • 2004
  • In this study, we introduced the spiral pipe nailing system (refer as SPN system) with self drilling method, can apply to ground which is hard to keep shape of bore hole, and performed limit equilibrium analysis with simplilied trial wedge method while length ratio and bond ratio were altered to evaluate slope stability considered of tensile strength and bending stiffness. A newly soil nailing system named as the SPN system is respected to reduce displacement of nail and increase global slope stability. And effects of various factors related to the design of the SPN system, such as the type of drilling method and the bit, are examined throughout a series of the displacement-controlled field pull-out tests. 6 displacement-controlled field pull-out tests are performed in the present study and the volume of grouting arc also evaluated based on the measurements. In addition, short-term characteristics of pull-out deformations of the newly proposed SPN system are analyzed and compared with those of the general soil nailing system by carrying out the displacement-controlled field pull-out tests.

  • PDF