• 제목/요약/키워드: Out-of-Phase

검색결과 4,407건 처리시간 0.034초

GSI(Global Single Instance)기반의 Global ERP 구축 방법론 및 적용 사례 (A Methodology for Global ERP Implementation Based on GSI(Global Single Instance) and Its Application)

  • 이재광;조민호
    • 한국IT서비스학회지
    • /
    • 제7권3호
    • /
    • pp.97-114
    • /
    • 2008
  • Many companies have implemented ERP systems to enhance their process competitiveness. Since most ERP systems down to date are implemented and managed on each separated business-unit or company level, such systems run short of the consideration about global business processes and global system managements. In order to integrate a successful global ERP, it is essential to apply the well-systematic implementation methodology which considers global standardization and global IT requirements. It is, however, the actual circumstance that such well-structured methodologies for global ERP implementation are hardly shown not only from domestic site but from foreign one. This paper indicates the global ERP implementation guideline with integrated approach including; the standard process design for efficient execution of global business; the ERP implementation method considering global IT requirements; and, the management method for global system operation. GSI ERP methodology is composed of 3 Phase:Global Strategy Planning, Global Template Construction and Global Roll-Out. Phase1; Global Strategy Planning contains Environment Analysis, GSI direction and Implementation Plan. Phase2; Global Template Construction contains Business blueprint, GSI operation design and Global template implementation. Phase3; Global Roll-out contains local business analysis, local ERP implementation and Global ERP Operation.

Corrosion of rebar in carbon fiber reinforced polymer bonded reinforced concrete

  • Bahekar, Prasad V.;Gadve, Sangeeta S.
    • Advances in concrete construction
    • /
    • 제8권4호
    • /
    • pp.247-255
    • /
    • 2019
  • Several reinforced concrete structures that get deteriorated by rebar corrosion are retrofitted using Carbon Fiber Reinforced Polymer (CFRP). When rebar comes in direct contact with CFRP, rebar may corrode, as iron is more active than carbon. Progression of corrosion of rebar in strengthened RC structures has been carried out when rebar comes in direct contact with CFRP. The experimentation is carried out in two phases. In phase I, corrosion of bare steel bar is monitored by making its contact with CFRP. In phase II, concrete specimens with surface bonded CFRP were casted and subjected to the realistic exposure conditions keeping direct contact between rebar and CFRP. Progression of corrosion has been monitored by various parameters: Half-cell potential, Tafel extrapolation and Linear Polarisation Resistance. On termination of exposure, to find residual bond stress between rebar and concrete, pull-out test was performed. Rebar in contact with CFRP has shown substantially higher corrosion. The level of corrosion will be more with more area of contact.

여자역도 인상종목의 경기력 결정요인 산출 (Determination of Performance Determinant Factors in Snatch Weightlifting)

  • 문영진
    • 한국운동역학회지
    • /
    • 제15권2호
    • /
    • pp.21-29
    • /
    • 2005
  • The Purpose of this study was to seek determinant factors through analysis of 65 snatch skill kinematic factors of Athletics participated in 2001 Asian weightlifting competetion. The conclusion were as follows ; 1. In order to enhance snatch skill, when barbell move on knee position, One should be flex knee joint to 105-110 degree, and In pull motion, One should be move powerful extension of knee and hip joint. 2. In last pull motion, One try to make more lock out motion than extra extention motion of hip joint 3. In order to enhance snatch skill, It is inportant that elevate barbell highly by last pull motion through powerful knee extention, poweful hip flextion and One should be make lock out motion fast in the same time. 4. In order to enhance snatch skill, anterior-posterior movement width of shoulder joint should be small. 5. In order to enhance snatch skill, Hip joint should be move vertically on start and lock out phase, but In pull phase, extension motion of hip joint shoulde be performed more largely and powerfully.

Measurement of a Mirror Surface Topography Using 2-frame Phase-shifting Digital Interferometry

  • Jeon, Seok-Hee;Gil, Sang-Keun
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.245-250
    • /
    • 2009
  • We propose a digital holographic interference analysis method based on a 2-frame phase-shifting technique for measuring an optical mirror surface. The technique using 2-frame phase-shifting digital interferometry is more efficient than multi-frame phase-shifting techniques because the 2-frame method has the advantage of a reduced number of interferograms, and then takes less time to acquire the wanted topography information from interferograms. In this measurement system, 2-frame phase-shifting digital interferograms are acquired by moving the reference flat mirror surface, which is attached to a piezoelectric transducer, with phase step of 0 or $\pi$/2 in the reference beam path. The measurements are recorded on a CCD detector. The optical interferometry is designed on the basis of polarization characteristics of a polarizing beam splitter. Therefore the noise from outside turbulence can be decreased. The proposed 2-frame algorithm uses the relative phase difference of the neighbor pixels. The experiment has been carried out on an optical mirror which flatness is less than $\lambda$/4. The measurement of the optical mirror surface topography using 2-frame phase-shifting interferometry shows that the peak-to-peak value is calculated to be about $0.1779{\mu}m$, the root-mean-square value is about $0.034{\mu}m$. Thus, the proposed method is expected to be used in nondestructive testing of optical components.

분리된 삼상자속구속형 전류제한기의 인덕턴스 변화에 따른 전류제한 특성 분석 (Analysis of Fault Current Limiting Characteristics According to Variation of Inductances in Separated Three-phase Flux-lock Type SFCL)

  • 두승규;두호익;김민주;박충렬;김용진;이동혁;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제22권6호
    • /
    • pp.522-525
    • /
    • 2009
  • We investigated the fault current characteristics of the separates three-phase flux-lock type superconducting fault current limiter(SFCL) according to the variation of inductances. The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core. And superconductor is series connected on secondary coil. Superconductor is using the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. To analyze the current limiting characteristics of a three-phase flux-lock type SFCL, the short circuit experiments were carried out fault such as the triple line-to-ground fault. The experimental result shows that fault current limiting characteristics of additive polarity winding was better than subtractive polarity winding and when the inductances of coil 2 was lower, resistances of YBCO CC was more generated.

Differences in EMG of Trunk and Lower Limb According to Attack Method and Phase During Volleyball

  • Jeong, Hwan Jong;Baek, Gwang Eon;Kim, Ki Hong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제13권1호
    • /
    • pp.143-151
    • /
    • 2021
  • The purpose of our study is to confirm the trend of the muscle activity of the trunk and lower limb muscles by the attack method and phase during volleyball exercise. To achieve this purpose, spike serve and spike were conducted for 9 male middle school students, and at that time, it was divided into four phase, such as run jump, take off, impact, and follow, and the rectus abdominis, erector spine, and left rectus femoris, left biceps femoris, left anterior tibialis, left gastrocnemius midialis, right rectus femoris, right biceps femoris, right anterior tibialis, right gastrocnemius midialis, were examined. Spike serve and spike were each performed three times, and randomly cross-allocated to extract accurate data. We was no difference in all muscles according to the attack method, and the muscle activity of the rectus abdominis was highest in the impact phase and the muscle activity of the vertebral spine muscle was highest in the close-up phase. In addition, all of the measured left and right lower limb muscles showed the highest muscle activity between the assisted devices. As a result, We found out that regardless of the method of spike serve and spike, the lower limbs in the run-up phase for a high jump, the vertebrae in the take off phase, the preparation phase for hitting the ball strongly, and in the impact phase at the moment of hitting the ball. It can be seen that it exerts the greatest power in the rectus abdominis.

Molecular Dynamics Study on the Structural Phase Transition of Crystalline Silver Iodide

  • Jun Sik Lee;Mee Kyung Song;Mu Shik Jhon
    • Bulletin of the Korean Chemical Society
    • /
    • 제12권5호
    • /
    • pp.490-494
    • /
    • 1991
  • The ${\beta} to {\alpha}$ phase transition in silver iodide is studied with the (N, V, E) and (N, P, T) molecular dynamics (MD) method. In experiments, the phase transition temperature is 420 K. Upon heating of ${\beta}$ form, the iodine ions undergo hcp to bcc transformation and silver ions become mobile. MD simulations for the ${\beta}$ and ${\alpha}$ phases are carried out at several temperatures and the radial distribution functions (rdf) are obtained at those temperatures in the (N, V, E) ensemble. But the phase transition is not found in our calculation. Next the phase transition is studied with the (N, P, T) MD and we find some evidences of phase transition. At 3 Kbars and 2 Kbars the phase transition temperatu re is about 300 K. For 3.55 Kbars, the phase transition is higher (420 K) than the low pressure case. The phase transition temperature is somewhat dependent on the pressure in our calculations.

이중퀜치를 이용한 삼상변압기형 한류기의 고장전류제한 동작 분석 (Analysis on Fault Current Limiting Operation of Three-Phase Transformer Type SFCL Using Double Quench)

  • 한태희;고석철;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제35권2호
    • /
    • pp.184-189
    • /
    • 2022
  • In this paper, the fault current limiting operations of three-phase transformer type superconducting fault current limiter (SFCL) using double quench, which consisted of E-I iron core with three legs wound by primary and secondary windings and two superconducting modules (SCMs), were analyzed according to three-phase ground fault types. To verify the effective operation of the three-phase transformer type SFCL using double quench, the test circuit for three-phase ground faults was constructed, and the fault current tests were carried out. Through analysis on the fault current test results, the different fault current limiting characteristics of three-phase transformer type SFCL using double quench from three-phase transformer type SFCL using three SCMs were discussed.

Two-Phase Magnet in the Co/Co2MnSn System

  • Kim, Tae-Wan;Yim, Hye-In;Lee, Hyun-Yong;Lee, Kyoung-Il
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.10-14
    • /
    • 2011
  • This study reports on Co/$Co_2$MnSn two-phase magnets. The Co/$Co_2$MnSn two-phase magnet has Co precipitates in a $Co_2MnSn$ Heusler alloy matrix, in which the two phases are exchange-coupled at the phase boundary. The as-casted Co/$Co_2$MnSn system, which has Co-Mn solid solution precipitates in a $Co_2$MnSn Heusler alloy matrix, showed that the Co solid solution precipitates are crystallographically coherent and there is exchange coupling at the phase boundary. To form pure Co precipitates by removal of Mn solute atoms in Co-Mn solid solution, annealing was carried out 48 hours at $870^{\circ}C$. After annealing, the low $T_c$ and low magnetization phase of the Co-Mn solid solution became a high $T_c$ and high magnetization phase of hexagonal Co.

System-On-Glass를 위한 Poly-Si TFT 소 면적 DC-DC 변환회로 (An Area-Efficient DC-DC Converter with Poly-Si TFT for System-On-Glass)

  • 이균렬;김대준;유창식
    • 대한전자공학회논문지SD
    • /
    • 제42권2호
    • /
    • pp.1-8
    • /
    • 2005
  • System-on-glass를 위해 poly-Si TFT로 면적이 작으면서도 리플전압을 최소화한 DC-DC 전압 변환회로를 개발하였다. 전압 변환회로는 전하 펌핑 회로, 문턱전압 변화를 보상한 비교기, 오실레이터, 버퍼, 다중 위상 클럭을 만들기 위한 지연 회로로 구성된다. 제안한 다중 위상 클럭킹을 적용함으로써 클럭 주파수 또는 필터링 캐패시터의 증가 없이도 낮은 출력 리플전압을 얻음으로써 DC-DC 변환기의 면적을 최소화 하였다. 제안한 DC-DC 변환회로를 제작하여 측정한 결과 $R_{out}=100k\Omega,\;C_{out}=100pF$, 그리고 $f_{clk}=1MHz$에서 Dickson 구조와 기존의 cross-coupled 구조에서의 리플전압은 각각 590mv와 215mv인 반면 4-위상 클럭킹을 적용한 구조에서는 123mV이다. 그리고 50mV의 리플전압을 가지기 위해 필요한 필터링 캐패시터의 크기는 $I_{out}=100uA$$f_{clk}=1MHz$에서 Dickson 구조와 기존의 cross-coupled 구조에서는 각각 1029pF와 575pF인 반면 4-위상과 6-위상 클럭킹을 적용한 구조에서는 단지 290pF와 157pF만이 각각 요구된다. 구조별 효율로는 Dickson 구조의 전하 펌프에서는 $59\%$, 기존의 cross-coupled 구조와 본 논문에서 제안한 4-위상을 적용한 cross-coupled 구조의 전하 펌프에서는 $65.7\%$$65.3\%$의 효율을 각각 가진다.