• Title/Summary/Keyword: Osterberg load test

Search Result 16, Processing Time 0.025 seconds

Axial Load Transfer Behavior of a Large Diameter Drilled Shaft by Osterberg Type Load Test (오스트버그식 재하시험을 이용한 대구경 현장타설말뚝의 축하중전이거동)

  • 임태경;정창규;정성민;최용규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.447-454
    • /
    • 2003
  • In this test, two separated oil jacks were placed at bottom of drilled shaft(D = 1,500mm, L = 33m), and maximum upward and downward load of 1,250 tonf was applied. Also, the deformable rod sensors were placed on each level, and axial strains at each level were measured. Because the side skin friction and the end bearing could be measured separately in the Osterberg type pile load test, this test might be more economical and more applicable than a conventional static pile load test. Thus, if this Osterberg type pile load test could be established during design stage, construction cost might be reduced and its application for large diameter pile could be enhance greatly.

  • PDF

Bearing capacity of a Flysch rock mass from the characterization of the laboratory physical properties and the Osterberg test

  • Hernan Patino;Ruben A. Galindo
    • Computers and Concrete
    • /
    • v.33 no.5
    • /
    • pp.573-594
    • /
    • 2024
  • This article presents a research study, with both laboratory and field tests, of a deep foundation in a markedly anisotropic medium. Particularly it has focused on the evaluation of the behavior of a pile, one meter in diameter, embedded in a rocky environment with difficult conditions, in the Flysch of the Spanish city of San Sebastián. To carry out the research, the site of a bridge over the Urumea River was chosen, which was supported by pre-excavated reinforced concrete piles. 4 borings were carried out, by the rotation and washing method, with continuous sampling and combined with flexible dilatometer tests. In the field, an Osterberg load test (O-cell) was performed, while in the laboratory, determinations of natural moisture, natural unit weight, uniaxial compressive strength (UCS), point load strength (PLS), compressive wave propagation velocity (Vc) and also triaxial and direct shear tests were carried out. The research results indicate the following: a) the empirical functions that correlate the UCS with the PLS are not always linear; b) for the studied Flysch it is possible to obtain empirical functions that correlate the UCS with the PLS and with the Vc; c) the bearing capacity of the studied Flysch is much greater than if it is evaluated by different load capacity theories; d) it is possible to propose an empirical function that allows evaluating the mobilized shear strength (τm), as a function of the UCS and the displacement relative of the pile (δr).

A Case Study on Application of O-cell Test in Oversea (양방향재하시험의 국외 적용 사례)

  • Lee, Won-Je;Molnit, Thomas
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.593-602
    • /
    • 2006
  • 대구경 현장타설말뚝에 대한 시험하중의 증가와 함께 적용이 활성화되고 있는 오스터버그 셀(Osterberg cell)방식이 적용된 국외의 4 개소 시험결과에 대하여 소개하였다. 사례연구의 대상이 된 4 개소 시험말뚝은 일반적인 시험보다는 결과상의 특징이 있어 현재 및 향후 동일한 시험방법이 적용될 경우 고려될 수 있는 내용을 중심으로 기술하였다. 이들 말뚝시험에서는 가장 전형적으로 지지력의 균형이 이루어져 말뚝의 극한현상이 발생되지 않아 설계하중을 충분히 확인한 경우뿐 아니라 선단지지력이 부족하여 선단 그라우팅 후 재시험을 한 경우, O-cell을 말뚝의 선단에 가장 근접하여 설치 한 후 시험한 경우, 그리고 다단면(multi-level test)시험이 수행되었던 예 등을 살펴보았다.

  • PDF

Osterberg Cell $(O-cell^{\circledR})$ method of Static Pile Load Testing in Korea (오스터버그 셀$(O-cell^{\circledR})$을 이용한 말뚝 정재하시험의 국내 적용)

  • Molnit, Thomas
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.520-529
    • /
    • 2006
  • 그 동안 몇 차례 오스터버그 셀$(O-cell^{\circledR})$을 이용한 양방향 말뚝 재하시험기법이 국내에 성공적으로 소개/적용된 바 있다. 이 방법은 상대적으로 새롭고 독특한 방법으로서 시험비용과 기존 재래적인 시험방법이 적용상 제한을 받는 경우나 대규모 시험에서 발생할 수 있는 문제점들을 극복할 수 있다. 국내에서는 설계목적을 위한 시험말뚝 뿐 아니라 설계하중이 큰 실제말뚝에 대한 시험이 증가하는 추세에 있다. 이 논문에서 소개하는 양방향 재하시험 방법을 적용하면 기존의 소규모 재하시험 방법에서 발생될 수 있는 주면 마찰력과 선단지지력의 분리측정이나 각각의 지지력에 대한 극한상태를 확인하지 못하는 한계를 극복할 수 있고 시험하중이 270MN을 초과하는 경우까지 적용할 수 있는 장점을 갖고 있다. 본 논문에서는 오스터버그 셀을 이용한 정적 재하시험 방법에 대하여 말뚝종류별로 상세히 기술하였으며 이 시험방법의 장점과 국내현장에 적용되었던 사례를 소개하였다.

  • PDF

Shaft resistance of bored cast-in-place concrete piles in oil sand - Case study

  • Barr, L.;Wong, R.C.K.
    • Geomechanics and Engineering
    • /
    • v.5 no.2
    • /
    • pp.119-142
    • /
    • 2013
  • Pile load tests using Osterberg cells (O-cell) were conducted on cast-in-place concrete piles founded in oil sand fill and in situ oil sand at an industrial plant site in Fort McMurray, Alberta, Canada. Interpreted pile test results show that very high pile shaft resistance (with the Bjerrum-Burland or Beta coefficient of 2.5-4.5) against oil sand could be mobilized at small relative displacements of 2-3% of shaft diameter. Finite element simulations based on linear elastic and elasto-plastic models for oil sand materials were used to analyze the pile load test measurements. Two constitutive models yield comparable top-down load versus pile head displacement curves, but very different behaviour in mobilization of pile shaft and end bearing resistances. The elasto-plastic model produces more consistent matching in both pile shaft and end bearing resistances whereas the linear elastic under- and over-predicts the shaft and end bearing resistances, respectively. The mobilization of high shaft resistance in oil sand under pile load is attributed to the very dense and interlocked structure of oil sand which results in high matrix stiffness, high friction angle, and high shear dilation.

Study of Smart Bi-directional Pile Load Test by Model Test (모형시험을 통한 Smart 양방향말뚝 재하시험에 관한 연구)

  • Kim, Nak-Kyung;Kim, Ung-Jin;Joo, Yong-Sun;Kim, Sung-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1088-1093
    • /
    • 2010
  • The Smart bi-directional pile load test with variable end plate overcomes the shortcoming of the Osterberg cell test. It is possible that the ultimate bearing capacity of piles can be known by using two different end plates. The first step is to measure end bearing capacity with smaller end plate and the second step is similar to the conventional O-cell test. In this study, model test was performed to evaluate the smart bi-directional pile load test in sand. Vertical displacement of the model pile were messured at the axial loading condition.

  • PDF

Evaluation of Bearing Capacity of Piles in Sand Using Pile Driving Analyzer (동재하시험을 이용한 모래지반의 말뚝지지력 산정)

  • 이우진;석종수
    • Geotechnical Engineering
    • /
    • v.13 no.5
    • /
    • pp.145-154
    • /
    • 1997
  • Though the static pile load tests gives the mosts accurate estimation on the load carrying capacity of tested pile, it appears time-consuming and not economical. Many test methods using equipments, such as Pile Driving Analyzer(PDA), STATNAMIC, and Osterberg cell, have been introduced in Korea, and pile best using PDA has been gaining popularity because of iris fast and simple operation. Static and dynamic tests results on the piles installed in the granular coils were analyzed to investigate the effect of geometrical damping on the estimated load carrying capacity. It was found that the CAPWAP analysis without considering geometrical damping effect underestimates the pile capacity by 30~60% under certain conditions. It was observed that the underestimation of pile capacity by CAPWAP occurs on the piles installed in the water-borne granular boils by SIP methods. When Smith skin damping value(SSkn) greater than 1.0 sec/m is obtained in CAPWAP analysis, it may reflect the large possibility of underestimation of pile capacity. The introduction of the geometircal damping option in CAPWAP analysis gives reasonable pile capacity, compared with the static pile load test results, and reduces the SSb value under 0.7 sec/m.

  • PDF

Numerical Analyses of O-Cell Load Test on Pile (양방향말뚝재하시험의 수치해석)

  • Joo, Yong-Sun;Kim, Nak-Kyoung;Kim, Woong-Jin;Park, Jong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.748-753
    • /
    • 2008
  • Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurisation causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. Bi-directional load tests using O-cell are now becoming common practice around the world, particularly where the loads to be applied are high or where it is not convenient to perform top-down loading tests. In the study, calculate ultimate capacity of bi-directional load test using FEM and beam on elasto-plastic foundation theory.

  • PDF

Design of Drilled Shafts Foundation by LRFD in Incheon Bridge Project (인천대교 민자구간의 대구경 현장타설 말뚝기초의 LRFD 설계 적용 사례)

  • Kim, Jeong-Hwan;Lee, Hyun-Gun;Shin, Hyun-Yang;Youn, Man-Geun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.551-561
    • /
    • 2006
  • Incheon bridge project is to construct total 12km long bridges on the sea consist of 800m span length cable stayed bridge, approach bridge and viaduct bridge based on LRFD design specification. To design pile foundations by RCD of each bridge unit, total 4 number of preliminary full scale pile load tests with Osterberg cell method were carried out on the piles for testing. The test load was planned to more than the expected design ultimate capacity and about 29,000tons maximum load was recorded. From the interpretation of test results, design parameters are evaluated and applied to the design. Preliminary pile load test plan and detailed execution of pile load tests are introduced and summarized. The resistance factors are presented for pile design of Incheon Bridge Project in LRFD considering variation of ground conditions and number of test piles.

  • PDF