• Title/Summary/Keyword: Optometry

Search Result 582, Processing Time 0.023 seconds

Study on Color and Oxidation Thickness for Titanium Spectacle Frames Colored by Anodization (양극산화방법으로 착색한 티타늄 안경테의 산화막 두께에 따른 색상 연구)

  • Hyun, Seung-Cheol;Jin, Moon-Seog;Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.33-37
    • /
    • 2009
  • Purpose: To examine the coloring condition of titanium spectacle frames with various colors by using anodization method. Methods: We made an anodization coater. Platinum plate with $3{\times}3cm^2$ was used for a cathode and titanium spectacle frame specimens was mounted on an anode in an electrolyte. An electric source device were designed to supply steady state current. The color of the coated spectacle frame specimens were measured by a spectrophotometer equipped with an integrating sphere. We use CIE $L^*a^*b$ color system as chromaticity coordinates. Results: The thickness of $TiO_2$ of titanium spectacle frame specimens was varied as controlling current flow time for electrodes. The specimens with various kinds of color as a walnut, a yellow brown, a navy blue, a blue, a light blue, a mung bean, a yellowish green, a light purple, a purple, a flower pink, a bluish green, an emerald, and a green color etc. were obtained. The values of CIE $L^*a^*b^*$ for these specimens were measured and analyzed to be changed clockwise in chromaticity coordinates as the thickness of $TiO_2$ increases. Conclusions: We identified the coloring mechanism by anodization method in titanium spectacle frame specimens.

  • PDF

A Study on the Clinical Practice in Ophthalmic Optics (안경광학과 임상실습 실태에 관한 연구)

  • Lee, Ok-Jin;Shin, Jin-Ah;Jung, Se-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.319-328
    • /
    • 2010
  • Purpose: To understand the status and actual condition of clinical practice in ophthalmic optics and offer a effective operation plan and improvement of quality of clinical practice. Methods: The school survey were investigated from 30 ophthalmic optics school and student survey were investigated from 161 students among these 4 schools. Results: 'No specific program for clinical practice' were 60.7%. Most schools apply clinical practice to credit (96.4%) but naming of subject and credit were varied in each school. 'Communication skill' was most difficult task and 'cleaning and arrangement of frame and stuff' were major task to students during clinical practice. Best benefits through clinical practice was 'knowing real status of optical business'. Comparison in carrier preference, optical shop and spectacles/contact lens company were decreased and eye hospital and norelation work were increased after clinical practice. Conclusions: Wide study on effective operation plan for clinical practice in ophthalmic optics and on the improvement of students' satisfaction and close cooperation and interest were needed between schools and clinical practice places.

A Relationship Between Visible Iris Diameter and Palpebral Aperture Size : Considered to Solve Uncomfortable Feeling of Soft Contact Lens (소프트콘택트렌즈 피팅과 관련된 가시홍채직경 및 검열크기에 대한 상관관계)

  • Lee, Jeong-Yun;Youk, Do-Jin;Lee, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.285-293
    • /
    • 2014
  • Purpose: In order to find suitable size of soft contact lens for different ages group of elementary student to adults, visible iris diameter(horizontal, vertical) and palpebral aperture size were measured. Methods: Visible iris diameter (horizontal, vertical) and palpebral aperture size were measured in different age groups of total 514 subjects (1028 eyes) who have no eye disease and none history of surgery included cosmetic purpose. Results: No significant difference was found in iris diameter of both horizontal and vertical direction for different groups of age and sex but horizontal direction of palpebral aperture size in middle school students and university students groups and vertical direction of palpebral aperture size in high school student group shows significant difference (p<0.05) by sex. Horizontal visible iris diameter, vertical visible iris diameter, horizontal palpebral aperture size and vertical palpebral aperture size shows significant difference in difference age and sex. Conclusions: Visible iris diameter and palpebral aperture size are affective factor for soft contact lens diameter decision, especially it should considered more intensive for removing uncomfortable feeling of lens wearer.

Association between Axial Length and Anthropometric Value in Korean Children (한국 어린이의 안축장과 신체 계측치와의 관련성)

  • Kim, Hyojin;Lyu, Jungmook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.397-402
    • /
    • 2014
  • Purpose: To investigate the relationship between axial length (AL) and anthropometric parameters in Korean children. Methods: This study included 40 urban school children aged 11-12 years (mean age, $11.95{\pm}0.22$ years; 45.0% girls) residing in Seoul, South Korea. AL (using partial coherence laser interferometry), corneal radius, refractive error, height (m), and weight (kg) were measured. Body mass index (BMI $[kg/m^2]=weight/[height]^2$) and degree of obesity (DO[%]=[actual weight standard weight]/standard weight) were calculated. Furthermore, the number of hours spent reading, watching television, and using a computer every day was determined using a detailed questionnaire. Results: The students had a mean spherical equivalent refraction of $1.06{\pm}0.84$ D. Weight (r=0.427, p=0.006), BMI (r=0.508, p=0.001), and DO (r=0.371, p=0.018) showed a significant positive correlation with AL. Furthermore, longer AL was significantly associated with heavier weight (p=0.041), and higher BMI (p=0.015), and higher DO quartiles (p=0.042). After adjust for age, sex, and near-work activities, multivariate linear regression models showed that weight, BMI, and DO were still significantly associated with AL. Among the near-work activities, daily reading time was significantly associated with AL. Conclusions: AL was positively related to weight as well as daily reading time in Korean urban school children.

Effect of Artificially Decreased Visual Acuity upon Eye-Hand Coordination using Lee-Ryan Eye-Hand Coordination Test (Lee-Ryan Eye-Hand Coordination Test를 이용한 인위적 시력저하가 눈-손 협응능력에 미치는 영향)

  • Lee, Ki-Seok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.371-376
    • /
    • 2014
  • Purpose: The aim of this study was to explore the effect of artificially decreased eye in normal vision on eye-hand coordination (EHC) when using the Lee-Ryan Eye-Hand Coordination Test recently reported. Methods: Eleven adults with normal vision aged $29.46{\pm}5.94$ years participated for this study where a non-dominant eye artificially induced moderate refractive amblyopic vision at near by adding a plus lens conducted EHC tasks and then did the test again under normal vision following 2 weeks. To investigate the ability of EHC, 7 tasks including individually different level of difficulty in the Lee-Ryan EHC Test were selected to compare and analyze EHC in terms of two independent variables such as time taken and the number of errors. Results: In time taken, subjects with artificially decreased vision took more time than normal vision under monocular conditions (p=0.013), while those with the decreased vision completed their tasks faster than normal vision under binocular conditions (p=0.001). In the number of errors, subjects with the decreased vision made more mistakes (p<0.001) as shown in time taken, whereas there was no difference between monocular and binocular viewing conditions in the decreased vision. Conclusions: Unlike previous EHC tests including limitations for application, deficit in EHC can be screened by the Lee-Ryan EHC Test developed based on simple computer-based system. Therefore, it is considered that further studies relevant to deficits in visual function such as amblyopia will be carried out in clinics as well as research.

Synaptic Pattern of NMDA R1 upon the Direction-Selective Retinal Ganglion Cells in Developing Mouse Retina (발생 중 마우스 망막에서 방향특이성 신경절세포의 NMDA R1 수용체의 시냅스 패턴)

  • Lee, Jee-Geon;Kwon, Oh-Ju;Jeon, Chang-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.533-540
    • /
    • 2013
  • Purpose: To investigate the synaptic pattern of NMDA glutamate receptor subtype NMDA R1 on the dendritic arbors of ON-OFF direction-selective retinal ganglion cells (DS-RGSs) in developing [(5,10) days postnatal (PN)] mouse retina. Methods: ON-OFF DS-RGCs were injected with Lucifer yellow and the cells were identified by their characteristic morphology. To identify glutamatergic excitatory input from bipolar cell, we used a marker for the membrane traffic motor protein kinesin. Results: We identified DS-RGCs in P5, and P10 mouse retina. The immunofluorescence labeling of NMDA R1 was most prominent in the IPL. Our results showed that their presence upon the entire dendritic arbor of ON-OFF DS-RGCs is without any evidence of asymmetry, which would predict direction selectivity. Conclusions: The glutamatergic input from bipolar cell reveals symmetry pattern in all periods of P5, and P10. The results may suggest that direction selectivity not lies in the specific pattern of NMDA R1 receptors.

Study on the Protective Effect of EGCG Against the Cytotoxicity Induced by Topical Anesthetic Proparacaine Hydrochloride (점안마취제 성분인 Proparacaine Hydrochloride의 세포독성에 대한 Epigallocatechin-Gallate의 효과)

  • Seo, Eun-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.525-531
    • /
    • 2013
  • Purpose: To identify the apoptosis caused by Proparacaine hydrochloride (PPC), a topical anesthesia, applied to conjunctival cell lines and determine whether pigallocatechin-gallate (EGCG), has protective effects on. Methods: The conjunctival cell lines were treated with 0.5% of Alcaine$^{(R)}$, 0.5% of PPC and 0.01% of Benzalkonium chloride (BAC) for 15 minutes, respectively in order to investigate the effects of topical anesthesia on cells, and followed by cultured for 12 and 24 hours. The recovery effects were investigated by measuring level of cellular proliferation inhibiting using MTT assay and LDH assay. The conjunctival cell lines were pre-treated with EGCG $10{\mu}M$ for 3 hrs and post-treated with 0.5% PPC for 15 mins in order to investigate whether EGCG has protective effects, flow cytometry were performed in order to observe apoptosis. Results: A result of the additional culture of 12 and 24 hours and again immediately after the treatment for 15 minutes 0.5% of Alcaine$^{(R)}$, 0.5% of PPC, the 0.01% of BAC, cell viability was not increased in all groups (p<0.05). The cell viabilities were higher than in cells 3 hours post-treated with $10{\mu}M$ of EGCG and pre-treated PPC 0.5% (68.2%), compared to cells ($32.2{\pm}2.0%$) treated only with 0.5% of PPC. PPC 0.5% also induced apoptosis in the treated group was reduced by the addition of EGCG. Conclusions: It is considered that the EGCG has cell protective effects when it is added to PPC, a topical anesthesia, by improving cell viability and inhibiting apoptosis.

The Design of Wide Angle Mobile Camera Corrected Optical Distortion for Peripheral Area (주변부 상의 왜곡을 보정한 모바일 광각 카메라의 광학적 설계)

  • Kim, Se-Jin;Jeong, Hye-Jung;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.503-507
    • /
    • 2013
  • Purpose: This study was to design wide angle mobile camera corrected optical distortion for peripheral area, which were reduced optical distortion and TV distortion by using 4 aspherical lenses. Methods: The optical design was satisfied with ${\pm}1%$ optical distortion in viewing angle of $95^{\circ}$ and total length of optical system was less than 4.5 mm which was considering a thickness of mobile camera. 1/3.2 inch (5M) CCD sensor was used in the optical system and set design condition to satisfy MTF which was over than 20% in 140 lp/mm. Results: Optimized wide angle mobile camera showed ${\pm}1%$ optical distortion in full field of $95^{\circ}$ viewing angle and TV distortion was 0.46% so that distortion of peripheral area was reduce. MTF showed over than 20% in every field. Ray aberration and astigmatism were small amount so that it showed stable performance. Conclusions: Obtain wider and clearer view which is reduced image distortion of surrounding area via optical method in wide angle mobile camera which has wider view angle than current mobile camera. And it was able to fix a demerit when it occurred via software correction. It is able to apply to study of camera which is related to spectacles.

Study on Physiological Summation in Peripheral Retina for Eccentric Viewing Training (중심외주시 훈련용 주변부 망막의 생리적 가중에 관한 연구)

  • Seo, Jae-Myoung;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.489-493
    • /
    • 2013
  • Purpose: This study was to investigate peripheral vision and provide people with macular degeneration with a guideline for eccentric viewing training. Methods: 30 adult subjects with normal vision took part in this study. The lateral area of $20^{\circ}$ eccentricity from the fovea of right eye was only used to measure the physiological summation. The target was sinusoidal vertical gratings within a circular aperture. The critical points in spatial and temporal summation was found to compare each other for 0.7 cpd and 3.0 cpd, respectively. Results: Critical duration and contrast sensitivity for 0.7 cpd were 540 ms and 1.1, and 315 ms and 0.98 for 3.0 cpd respectively. The critical degrees and contrast sensitivity for 0.7 cpd were $11.3^{\circ}$ and 2.8, and $5^{\circ}$ and 2.63 for 3.0 cpd respectively. Conclusions: The critical point in peripheral vision reaches relatively faster than the one in central vision. It is recommended to train the peripheral retina under the lower spatial frequency more frequently for a short time than constantly for a long time.

Study on the Analysis of Corneal Variation by Refractive Error (굴절이상에 의한 각막 변화도 분석에 관한 연구)

  • Lee, Hae-Jung;Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.485-490
    • /
    • 2014
  • The purpose of this Study investigated corneal power, corneal astigmatism and corneal axis according to spherical equivalent of refractive error. We measured spherical equivalent, corneal power and corneal astigmatism in 100 subjects from January 2014 to July 2014. Measured spherical equivalent of refractive error were $-3.01{\pm}3.79D$, corneal power of $43.79{\pm}1.60D$ and corneal astigmatism of $-1.17{\pm}0.79D$ respectively. Prevalence of spherical equivalent of refractive error were as follows : myopes (61%), emmetropes (22%), hyperopes(17%). Corneal astigmatism of refractive error greater than +0.75D was 63% and prevalence of corneal astigmatism were as follows : with-the-rlue astigmatism (84.13%), against-the-rule astigmatism(9.52%) respectively. Corneal power by spherical equivalent increased from hyperopia to myopia. Between spherical equivalent of refractive error and the mean corneal power was significant correlation(r=-0.25, p=0.01). A correlation were found between corneal power and spherical equivalent of refractive error in adults. They have the highest distribution of prevalence myopia among the refractive error. When the refractive error was increased, we found that corneal power was steeper. It is recognized that this can be refractive error factor and correct visual function is considered.