• Title/Summary/Keyword: Optimum Performance

Search Result 3,657, Processing Time 0.037 seconds

Performance Comparisons of some nonparametric detectors (몇가지 비모수 검파기의 성능 비교)

  • 김홍길;송익호;장태주;배진수
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1996.06a
    • /
    • pp.9-15
    • /
    • 1996
  • In this paper, we propose a new detector based on the median-shift sign. We call it the median-shift sign (MSS) detector, which is an extension of the classical sign detector. We first analyze the problem of detecting a dc signal in noise of known probability density function (pdf). The MSS detector with the optimum median-shift value, the optimum MSS detector, performs better than the sign detector in Gaussian noise: it has the best performance among the detectors compared in Laplacian and Cauchy noise. It is shown that the MSS detectors with constant median-shift values are nearly equal to the optimum MSS detector. We also analyze the problem of detecting a dc signal when only partial information is available on the noise. The MSS detectors with constant median-shift values are almost equal to the sign detector in Gaussian noise: they perform better than the sign and Wilcoxon detectors for most signal ranges in Laplacian and Cauchy noise.

  • PDF

Performance Analysis of Simultaneous Heating & Cooling Water Making System(I)-Simulation (냉.온열 동시 제조시스템의 성능분석(I)-Simulation)

  • Park, Seong-Ryong;Park, Jun-Tack;An, Young-Hun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.266-271
    • /
    • 2001
  • In this study, the performance of the simultaneous heating & cooling water making system using R134a was investigated by simulation. The most important effect upon heating COP was intermediate pressure depending on input water temperature. With the input water temperature of $10^{\circ}C\;and\;20^{\circ}C$, optimum intermediate pressure were 923 and 1040kPa, respectively. At that optimum intermediate pressure, the maximum heating COP of the system operated between $0^{\circ}C$ evaporating temperature and $70^{\circ}C$ condensing temperature were 4.15 and 3.83. With installation of the subcoolers in high or low pressure section, the system COP was increased by reducing the refrigerant mass flow rate. Under the optimum pressure and $10^{\circ}C$ input water temperature, it was found that heating COP was maximized when the low-subcooler and high-subcooler capacity rate were taken by 14% and 13%, respectively.

  • PDF

Characteristic Analysis & Optimum Design of Permanent Magnet Assisted Synchronous Reluctance Motor for Premium Efficiency Performance (효율 향상을 위한 영구자석 매입형 동기 릴럭턴스 전동기의 특성해석과 최적설계)

  • Mun, Sung-Ju;Lee, Tae-Hoon;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.716_717
    • /
    • 2009
  • This paper deals with the characteristic analysis & optimum design of Permanent Magnet Assisted Synchronous Reluctance Motor(PMASynRM) for Premium Efficiency Performance. The focus of this paper is characteristic analysis of d and q-axis inductances and torque according to magnetizing quantity of interior permanent magnet for PMASynRM. The d and q-axis current component ratios, load angles of a PMASynRM are investigated quantitatively on the basis of the proposed analysis method and the experimental test. Comparisons are given with output characteristic curves of normal SynRM and those according to the load in PMASynRM, respectively. And optimum design of PMASynRM is performed by Response Surface Methodology(RSM).

  • PDF

Optimum Configuration of Multiple Antennas for the Combinded System with Tx. Diversity and Beamforming

  • Yu, Hyun-Hye;Liu, Li-Jun;Lim, Myoung-Seob
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.7A
    • /
    • pp.727-732
    • /
    • 2008
  • The transmit diversity as well as beamforming can increase the performance of wireless communication systems. It is well known that the requirement for the spacing between the neighboring antennas in transmit diversity and beamforming is contradictive to each other. Therefore it is necessary to find the optimum configuration of multiple antennas for getting the maximum performance under the condition that the total number of antennas at transmitter site and the total power of transmitter are fixed. In this paper, the procedure for finding the optimum configuration of multiple antennas was derived through searching the maximum capacity and BER in the combined system with the transmit diversity (Tx diversity) and beamforming.

Optimum SIL System Design with High NA and Large Tolerance

  • Won, Ki-Tak;Choi, Na-Rak;Kim, Jai-Soon;Lee, Ji-Yeon;Lee, Kyung-Eon;Shin, Yun-Sup
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.02a
    • /
    • pp.277-278
    • /
    • 2007
  • Even though high NA, Hyper SIL system easily decline the optical performance even a little alignment error. Not only to overcome this instability but to maintain the high NA gain, we suggest a new system (Optimum SIL) which is a combination of each advantage of Hyper SIL and Hemi SIL. Simulation results shows that Optimum SIL system has much higher tolerance to various performance-lowering factors than Hyper SIL system even with a relatively small NA resignation.

  • PDF

Vibration Analysis of Boring Bar with Dynamic Vibration Absorber (동흡진기형 보링바의 진동해석)

  • Lee, Jae-Hyuk;Rim, Kyung-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1796-1802
    • /
    • 2000
  • The purpose of this work is to analyze the vibration characteristic of boring bar with dynamic vibration absorber and find out the effective design parameters. Using the finite element method and modified optimum design concept, conventional optimum design based on approximate lumped parameter model is checked and practical design to be measured with modal analysis is compared with optimum design from numerical analysis. Also, the performance of reducing vibration is investigated with variation of shape of boring bar. The considered model of boring bar with dynamic vibration absorber is selected among manufactured boring bars with the best performance.

  • PDF

Experimental Study on the MIMO Control Algorithm of a Multi-Heat Pump Based on PRBS Identification Scheme (PRBS 시스템 규명 기법 적용 멀티 열펌프의 다중입출력 제어특성에 관한 실험적 연구)

  • Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.2
    • /
    • pp.16-24
    • /
    • 2013
  • A multi-heat pump provides the benefits of comfort, energy conservation and easy maintenance. Recently, the multi-heat pump has been widely employed in small and medium-sized buildings. However, the control algorithm of the multi-heat pump are limited in the open literature due to complicated operating conditions. In this study, the MIMO control algorithm using integral optimum regulator was designed and the control performance of it was analyzed. In addition, system model of the control plant was developed by PRBS system identification scheme. The MIMO controller adopting the integral optimum regulator yielded satisfactory control performance results.

A nonparametric detector for random signals in a multiplicative noise model (곱셈꼴 잡음모형에서 비모수 확률 신호 검파기)

  • 배진수;박정순;김광순;송익호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.4
    • /
    • pp.796-804
    • /
    • 1998
  • Multiplicative noise is known to be useful in modeling multipath propagation, which is crucial in mobile communication systems analysis. In this paper, nonparametric detection of weak random signals in multiplicative noise is considered. The locally optimum detector based on signs and ranks of observations isderived for good weak-signal detection performance under any noise probability density function. the detector has similarities to the locally optimum detector for random signals in multiplicative noise. It is shown that the nonparametric detector asymptotically hs almost the same performance as the locally optimum detector.

  • PDF

On a Detection Scheme for Weak Deterministic Signals in Non-Additive Noise (비가산성 잡음에서의 약한 화정적 신호의 검파방식에 관하여)

  • Song, Iick-Ho
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.9
    • /
    • pp.1019-1026
    • /
    • 1988
  • A parametric detection scheme for determenistic signals is obtained in a generalized observation model which contains non-additive noise. The model employed in this paper includes several special cases such as those describing purely-additive noise, multiplicative noise, and signal dependent noise and allows the consideration of deterministic and random signals. Locally optimum detectors for known deterministic signals in the model are derived and analyzed for performance. It is shown that the locally optimum detectors are interesting generalizations of those for the purely-additive noise model. Performance of the locally optimum detectors designed for the generalized observation model is compared to that of other common detectors.

  • PDF

Thermodynamic performance of 2-PCM latent heat thermal energy storage system (2-PCM 잠열축열 시스템의 열역학적 성능)

  • 이세균;우정선;이재효;김한덕
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.2
    • /
    • pp.189-199
    • /
    • 2000
  • This paper investigates the thermodynamic performance of latent heat thermal energy storage system using two phase change materials(2-PCM system). The thermodynamic merit of using 2-PCM is clear in terms of exergetic efficiency, which is substantially higher than that of 1-PCM system. Optimum phase change temperature to maximize the exergetic efficiency exists for each case. The heat transfer area ratio of high temperature storage unit, X, becomes another important parameter for 2-PCM system if the phase change temperatures of given materials are different from those of optimum conditions. It is a good approximation for X$_{opt}$ to be 0.5 when optimum phase change temperatures are used. Otherwise X$_{opt}$ is determined differently as a function of given phase change temperatures.res.

  • PDF