Experimental Study on the MIMO Control Algorithm of a Multi-Heat Pump Based on PRBS Identification Scheme  

Choi, Jong Min (Department of Mechanical Engineering, Hanbat National University)
Publication Information
Journal of the Korean Society for Geothermal and Hydrothermal Energy / v.9, no.2, 2013 , pp. 16-24 More about this Journal
Abstract
A multi-heat pump provides the benefits of comfort, energy conservation and easy maintenance. Recently, the multi-heat pump has been widely employed in small and medium-sized buildings. However, the control algorithm of the multi-heat pump are limited in the open literature due to complicated operating conditions. In this study, the MIMO control algorithm using integral optimum regulator was designed and the control performance of it was analyzed. In addition, system model of the control plant was developed by PRBS system identification scheme. The MIMO controller adopting the integral optimum regulator yielded satisfactory control performance results.
Keywords
Heat pump; MIMO; Integral optimum regulator; System identification;
Citations & Related Records
연도 인용수 순위
  • Reference
1 He, X., Liu, X., Asada, H., and Itoh, H., 1998, Multi-variable control of vapour compression systems, ASHRAE J HVAC&R, Vol. 4, Part 3, pp. 205-229.   DOI   ScienceOn
2 Lida, K., Yamamoto, T., Kuroda, T., and Hibi, H., 1982, Development of an energy saving oriented variable capacity system heat pump, ASHRAE Trans., Part 1, Vol. 88, pp. 441-450.
3 Chua, K.J., Chou, S.K., and Yang, W.M., 2010, Advances in heat pump systems: a review, Applied Energy, Vol. 87, pp. 3611-3624.   DOI   ScienceOn
4 Matsuoka, F. and Nagatomo, H., 1983, Dynamic response and electrical control for the air conditioner, Transaction of the JAR, Vol. 5. No. 1, pp. 43-54.
5 Yasuda, H., Ishibane, K., and Nakayama, S., 1992, Evaporator superheat control by an electrically driven expansion valve, Trans. of the JAR, Vol. 9, No. 2, pp. 147-156.   DOI
6 Fujita, Y., Kubo, T., and Suma, S., 1992, Multi air conditioner with two indoor units, Refrigeration, Vol. 67, No. 772, pp. 171-176.
7 McLinden, M.O., Klein, M.O., Lemmon, E. W., and Peskin, A. P., 1998, Thermodyna -mic and transport properties of refrigerants and refrigerant mixtures (REFPROP 6.0), NIST, Gaithersburg, MD., U.S.A.
8 Landau I., 1990, System Identification and Control Design, Prentice Hall, Prentice Hall Information and System Sciences Series.
9 Choi, J.M. and Kim, Y.C., 2003, Capacity modulation of an inverter-driven multi-air conditioner using electronic expansion valves, Energy, Vol. 28, No. 2, pp. 141-155.   DOI   ScienceOn
10 Jolly, P.G., Tso, C.P., Chia, P.K., and Wong, Y.W., 2001, Intelligent control to reduce superheat hunting and optimize evaporator performance in container refrigeration, ASHRAE Winter Meeting, ISSN 1588-8586, Atlanta, USA. Paper No. 4441.