• 제목/요약/키워드: Optimum Load

검색결과 985건 처리시간 0.018초

최적부하제한방식의 결정과 운용에 관한 연구 (A Study on the Determination and Application of the Optimum Load Shedding Schemes)

  • Song, Kil-Yeong
    • 대한전기학회논문지
    • /
    • 제34권1호
    • /
    • pp.29-37
    • /
    • 1985
  • During Severe emergencies which result in the case of outage of large generator units, an automatic underfrequency protection scheme can prevent the system frequency from decaying and improve the system stability. This paper presents methods and results of a study on the optimum load shedding scheme which covering as follows. 1) Detail representation of governor model 2) Determination of optimum load shedding amount 3) Selection of action time settings of UFR 4) Comparsson of load shedding programs By this study, the optimum system operating method was recommended for reliable operation of power system.

  • PDF

운전예비력의 최적운용방식에 관한 연구 (A study on the optimum operation scheme with operating reserve power)

  • 송길영
    • 전기의세계
    • /
    • 제28권5호
    • /
    • pp.49-55
    • /
    • 1979
  • During severe emergencies which result in insufficient generation to meet load, an automatic load shedding method considering the spinning and operating reserve can establish the optimum system operation. This paper presents methods and results of a study on the optimum operating scheme with spinning and operating reserve power in case of outage of large generator units to prevent frequency decay and continue stable operation. This study covers following three parts 1) Analysis of spinning reserve characteristics 2) Determination of operating reserve requirements 3) Development of the optimum load shedding programs By this study the optimum system operating method was recommended for reliable operation of power system.

  • PDF

배전용 변압기의 합리적인 사양과 그 설계법 (The optimum specifications and design of distributive transformers)

  • 이승원
    • 전기의세계
    • /
    • 제14권4호
    • /
    • pp.8-17
    • /
    • 1965
  • Firstly, this study has analyzed the following factors affecting the optimum specifications and design of distributive transformers: 1. Facilities installation cost per unit power output. 2. Facilities operating & maintenance cost per unit power output. 3. Production cost per unit power output. 4. Load factor. 5. Loss factor. Secondly, it has clarified the relations between the following factors and the specifications and design of distributive transformers; 1. No-load loss., 2. Load loss., 3. Voltage regulation., 4. Exciting current. Finally, it has determined the method of the most economic design for the transformers using the above factors and relations, and, for optimum the illustrative purpose, suggested their optimum specifications, way of evaluation, and merits by means of typical example.

  • PDF

하중 계수에 기초한 최적신뢰성해석 모델 개발 (Development of Load Factors Based on Optimum Reliability Analysis Model)

  • 이증빈;신형우
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 봄 학술발표회 논문집
    • /
    • pp.134-139
    • /
    • 1992
  • This study introduces simple derivation of optimum load factors based on both cornell's MFOSM (Mean First Order End Moment) methods and Lind - Hasofers AFOSM (Advanced First Order 2nd Moment) methods and demonstrates the relationship between the optimum reliability, the load factors, the probability distributions selected to model the load, and a measure of relative failure cost. Although some of the cost parameters cannot be evaluated accurately and the upper tail characteristics of the distributions of the random loads remain uncertainty, this optimum reliability formulation provides insight on which Parameters are most significant in selecting appropriate load criteria for structure design.

  • PDF

냉방부하 최소화를 위한 지붕의 최적기울기에 관한 연구 (A Study on the Optimum Slope of the Roof for Minimum Cooling Load)

  • 태원진
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.119-123
    • /
    • 2005
  • The main purpose of this study is to define an optimum slope of the roof that demands minimum cooling load of the building, when the roof is affected by the solar and wind energy. Two different roof shapes were chosen: hip, gabled. The cooling load of building having those roof shapes was calculated through the computer simulation, using DOE program. For the simulation, the angle of the roof and angle of the orientation was changed. In the conclusion of this paper, an optimum slope of the roof which causes minimize cooling load is presented according to the roof shape and orientation. The result of this study could provide a practical design guideline for determining the roof angle for various climatic conditions.

보강된 섬유강화 복합재료 패널의 좌굴해석 및 파손강도의 최적 설계 (Optimization for Buckling and Postbuckling Behavior of Stiffened Fiber Reinforced Composite Panels)

  • 이광록;양원호;조명래;성기득
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.913-919
    • /
    • 2001
  • In this study, fiber orientation of stiffener was conducted to increase buckling load or failure load in each case with a different design value and a different objective function for stiffened laminated composite panel of I-type under compression loading. Regarding each of buckling load or failure load as objective function, optimum design was carried out. In respect of optimum design, it was investigated that optimum shape for buckling could improve fail load for postbuckling, because it was difficult to investigate the optimization of postbuckling which need long analysis times for nonlinear analysis.

  • PDF

열전냉동기용 열전요소의 최적화 (Optimization of Thermoelectric Elements for Thermoelectric Coolers)

  • 정은수
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.409-414
    • /
    • 2012
  • A theoretical investigation to optimize thermoelectric elements for thermoelectric coolers was performed using a new one-dimensional analytic model. Mathematical expressions for the optimum current and the optimum length of a thermoelectric element, which maximize the coefficient of performance of thermoelectric coolers, were obtained. The optimum current is expressed in terms of the cooling load for a thermoelectric element, the hot and cold side temperatures and thermoelectric properties, but not the length of a thermoelectric element. The optimum current is proportional to the cooling load and decreases as the temperature difference between the hot and cold sides decreases. It is also shown that the optimum length of a thermoelectric element decreases as the cooling load increases.

하중계수에 기초한 최적신뢰성의 해석모델 개발 (Development of Load Factors-Based Analysis Model of Optimum Reliability)

  • 이증반;신형우
    • 전산구조공학
    • /
    • 제5권4호
    • /
    • pp.113-124
    • /
    • 1992
  • 토목구조물 설계에 있어서 가장 보편적으로 사용되고 있는 도로교에 대한 하중계수에 기초한 최적신뢰성해석모델을 제안하고, 또 총기대비용 최소화원칙에 기인한 최적하중-저항계수 및 최적 공칭안전율에 대한 이론적 근거를 제시하는 것이 본 연구의 주요내용이다. MFOSM과 AFOSM을 포함하는 주요 2차 모멘트신뢰성 이론을 비교분석함으로써 AFOSM의 근사식과 대수정규포근사식을 본 연구에서 제안하는 최적신뢰성 및 설계규준의 유도에 사용함이 적절하다는 것을 알 수 있었다.

  • PDF

Lagrange Multipliers에 의한 슬래브시스템의 신뢰성 최적설계 (Reliability Optimum Design of Slab System based on Lagrange Multipliers)

  • 김현석;이증빈;정철원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제1권1호
    • /
    • pp.113-124
    • /
    • 1997
  • Based on the recent developments of the reliability-based structural analysis and design as well as the extending knowledge on the probabilistic characteristics of load and resistances, the probability based design criteria have been successfully developed for many standards. Since the probabilistic characteristics depend highly on the local load and resistances, it is recognized to develop the design criterion compatible with domestic requirements. The existing optimum design methods, which are generally based on the structural theory and certain engineering exprience, do not realistically consider the uncertainties of load and resistances and the basic reliability concepts. This study is directed to propose a optimum design based Expected Total Cost Minimization on two-way slab system which could possibly replace optimum design based traditional provisions of the current code, based on the AFOSM reliablity theory.

  • PDF

Feedback Analysis of Transcutaneous Energy Transmission with a Variable Load Parameter

  • Yang, Tianliang;Zhao, Chunyu;Chen, Dayue
    • ETRI Journal
    • /
    • 제32권4호
    • /
    • pp.548-554
    • /
    • 2010
  • The transcutaneous energy transmission system (TETS) composed of a Class-E amplifier may operate at a state away from the optimum power transmission due to the load variation. By introducing the feedback-loop technique, the TETS can keep the optimum state with constant output voltage by adjusting the important design parameters, that is, the duty ratio and frequency of the driving signal and the supply voltage. The relations between these adjusted parameters and the load are investigated. The effectiveness of the feedback technique is validated through a design example with a variable load parameter. The experimental results show that the Class-E amplifier in the feedback loop can keep operating at the optimum state under the condition of up to 50 percent variation of the load value.