• Title/Summary/Keyword: Optical simulation

Search Result 1,775, Processing Time 0.024 seconds

Figure of merit and bending characteristics of Mn-SnO2/Ag/Mn-SnO2 tri-layer film (Mn-SnO2/Ag/Mn-SnO2 3중 다층막의 성능지수와 밴딩 특성)

  • Cho, Youngsoo;Jang, Guneik
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.4
    • /
    • pp.190-195
    • /
    • 2021
  • Typical Mn-SnO2/Ag/Mn-SnO2 tri-layer films were prepared on a PET substrate by RF/DC magnetron sputtering method at room temperature. Based on EMP simulation, the thicknesses of the top and bottom Mn-doped SnO2 layers were kept at 40 nm and the Ag layer was maintained at 13 nm for continuous electrical conduction. The experimentally measured optical transmittances at 550 nm wavelength were ranged from 82.9 to 88.1 % and sheet resistances were varied from 5.9 to 6.9 Ω/☐. The highest value of figure of merit, ϕTC was 48.1 × 10-3 Ω-1. Based on bending test under 4 and 5 mm of inner and outer curvature radius condition, tri-layer film resistance varies only by approximately 1.5 % after 10,000 bending cycles, showing excellent mechanical flexibility.

Atmospheric Correction of Sentinel-2 Images Using Enhanced AOD Information

  • Kim, Seoyeon;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.1
    • /
    • pp.83-101
    • /
    • 2022
  • Accurate atmospheric correction is essential for the analysis of land surface and environmental monitoring. Aerosol optical depth (AOD) information is particularly important in atmospheric correction because the radiation attenuation by Mie scattering makes the differences between the radiation calculated at the satellite sensor and the radiation measured at the land surface. Thus, it is necessary to use high-quality AOD data for an appropriate atmospheric correction of high-resolution satellite images. In this study, we examined the Second Simulation of a Satellite Signal in the Solar Spectrum (6S)-based atmospheric correction results for the Sentinel-2 images in South Korea using raster AOD (MODIS) and single-point AOD (AERONET). The 6S result was overall agreed with the Sentinel-2 level 2 data. Moreover, using raster AOD showed better performance than using single-point AOD. The atmospheric correction using the single-point AOD yielded some inappropriate values for forest and water pixels, where as the atmospheric correction using raster AOD produced stable and natural patterns in accordance with the land cover map. Also, the Sentinel-2 normalized difference vegetation index (NDVI) after the 6S correction had similar patterns to the up scaled drone NDVI, although Sentinel-2 NDVI had relatively low values. Also, the spatial distribution of both images seemed very similar for growing and harvest seasons. Future work will be necessary to make efforts for the gap-filling of AOD data and an accurate bi-directional reflectance distribution function (BRDF) model for high-resolution atmospheric correction. These methods can help improve the land surface monitoring using the future Compact Advanced Satellite 500 in South Korea.

Cerebral Oxygenation Monitoring during a Variation of Isoflurane Concentration in a Minimally Invasive Rat Model

  • Choi, Dong-Hyuk;Kim, Sungchul;Shin, Teo Jeon;Kim, Seonghyun;Kim, Jae Gwan
    • Current Optics and Photonics
    • /
    • v.6 no.5
    • /
    • pp.489-496
    • /
    • 2022
  • Our previous study on monitoring cerebral oxygenation with a variation of isoflurane concentration in a rat model showed that near-infrared spectroscopy (NIRS) signals have potential as a new depth of anesthesia (DOA) index. However, that study obtained results from the brain in a completely invasive way, which is inappropriate for clinical application. Therefore, in this follow-up study, it was investigated whether the NIRS signals measured in a minimally invasive model including the skull and cerebrospinal fluid layer (CSFL) are similar to the previous study used as a gold standard. The experimental method was the same as the previous study, and only the subject model was different. We continuously collected NIRS signals before, during, and after isoflurane anesthesia. The isoflurane concentration started at 2.5% (v/v) and decreased to 1.0% by 0.5% every 5 min. The results showed a positive linear correlation between isoflurane concentration and ratio of reflectance intensity (RRI) increase, which is based on NIRS signals. This indicates that the quality of NIRS signals passed through the skull and CSFL in the minimally invasive model is as good as the signal obtained directly from the brain. Therefore, we believe that the results of this study can be easily applied to clinics as a potential indicator to monitor DOA.

Diffraction-efficiency Correction of Polarization-independent Multilayer Dielectric Gratings (무편광 유전체 다층박막 회절격자의 효율 보정)

  • Cho, Hyun-Ju;Kim, Gwan-Ha;Kim, Dong Hwan;Lee, Yong-Soo;Kim, Sang-In;Cho, Joonyoung;Kim, Hyun Tae
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.1
    • /
    • pp.22-27
    • /
    • 2022
  • We fabricate a polarization-independent dielectric multilayer thin-film diffraction grating for a spectral-beam-combining (SBC) system with a simple grating structure and low aspect ratio. Due to the refractive index and thickness error of the manufactured thin films, the diffraction efficiency of the fabricated diffraction grating was lower than that of the design. The causes of the errors were analyzed, and it was confirmed through simulation that diffraction efficiency could be compensated through an additional coating on the manufactured diffraction grating. As a result of sputtering an additional Ta2O5 layer on a fabricated diffraction grating, the diffraction efficiency was corrected and a maximum 91.7% of polarization-independent diffraction efficiency was obtained.

Derivation of Surface Temperature from KOMPSAT-3A Mid-wave Infrared Data Using a Radiative Transfer Model

  • Kim, Yongseung
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.4
    • /
    • pp.343-353
    • /
    • 2022
  • An attempt to derive the surface temperature from the Korea Multi-purpose Satellite (KOMPSAT)-3A mid-wave infrared (MWIR) data acquired over the southern California on Nov. 14, 2015 has been made using the MODerate resolution atmospheric TRANsmission (MODTRAN) radiative transfer model. Since after the successful launch on March 25, 2015, the KOMPSAT-3A spacecraft and its two payload instruments - the high-resolution multispectral optical sensor and the scanner infrared imaging system (SIIS) - continue to operate properly. SIIS uses the MWIR spectral band of 3.3-5.2 ㎛ for data acquisition. As input data for the realistic simulation of the KOMPSAT-3A SIIS imaging conditions in the MODTRAN model, we used the National Centers for Environmental Prediction (NCEP) atmospheric profiles, the KOMPSAT-3Asensor response function, the solar and line-of-sight geometry, and the University of Wisconsin emissivity database. The land cover type of the study area includes water,sand, and agricultural (vegetated) land located in the southern California. Results of surface temperature showed the reasonable geographical pattern over water, sand, and agricultural land. It is however worthwhile to note that the surface temperature pattern does not resemble the top-of-atmosphere (TOA) radiance counterpart. This is because MWIR TOA radiances consist of both shortwave (0.2-5 ㎛) and longwave (5-50 ㎛) components and the surface temperature depends solely upon the surface emitted radiance of longwave components. We found in our case that the shortwave surface reflection primarily causes the difference of geographical pattern between surface temperature and TOA radiance. Validation of the surface temperature for this study is practically difficult to perform due to the lack of ground truth data. We therefore made simple comparisons with two datasets over Salton Sea: National Aeronautics and Space Administration (NASA) Jet Propulsion Laboratory (JPL) field data and Salton Sea data. The current estimate differs with these datasets by 2.2 K and 1.4 K, respectively, though it seems not possible to quantify factors causing such differences.

A Fundamental Study on Structure Health Monitoring System Based on Energy Harvesting of Harbour Structure (자가발전기반 항만 구조물 건전성 모니터링 시스템에 대한 기초연구)

  • Jong-Hwa Yi;Seung-Hyeon Lee;Young-seok Kim;Chul Park
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.847-860
    • /
    • 2022
  • Purpose: The purpose of this paper is to present a basic study on the development of a self-generation infrastructure for monitoring the health of harbour structures. Method: By developing a self-generation system and fiber optic sensors for seawater, the study provides basic research data on port structure health monitoring. Result: Through sunlight simulation analysis, 4-5 hours of sunlight can be secure in the domestic environment. Through this, the optical splitter (Introgate) that collects the raw data from the FBG sensor applicable to seawater, the MCU that calculates it, the IoT module with wireless communication functionality, the monitoring server and the supply system are set up. Conclusion: Monitoring port structures directly with fiber optic probes (FBG) and the possibility of using selfpowered systems were confirmed.

Analysis of Laser-protection Performance of Asymmetric-phase-mask Wavefront-coding Imaging Systems

  • Yangliang, Li;Qing, Ye;Lei, Wang;Hao, Zhang;Yunlong, Wu;Xian'an, Dou;Xiaoquan, Sun
    • Current Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • Wavefront-coding imaging can achieve high-quality imaging along with a wide range of defocus. In this paper, the anti-laser detection and damage performance of wavefront-coding imaging systems using different asymmetric phase masks are studied, through modeling and simulation. Based on FresnelKirchhoff diffraction theory, the laser-propagation model of the wavefront-coding imaging system is established. The model uses defocus distance rather than wave aberration to characterize the degree of defocus of an imaging system. Then, based on a given defocus range, an optimization method based on Fisher information is used to determine the optimal phase-mask parameters. Finally, the anti-laser detection and damage performance of asymmetric phase masks at different defocus distances and propagation distances are simulated and analyzed. When studying the influence of defocus distance, compared to conventional imaging, the maximum single-pixel receiving power and echo-detection receiving power of asymmetric phase masks are reduced by about one and two orders of magnitude respectively. When exploring the influence of propagation distance, the maximum single-pixel receiving power of asymmetric phase masks decreases by about one order of magnitude and remains stable, and the echodetection receiving power gradually decreases with increasing propagation distance, until it approaches zero.

Convergence study of traditional 2D/1D coupling method for k-eigenvalue neutron transport problems with Fourier analysis

  • Boran Kong ;Kaijie Zhu ;Han Zhang ;Chen Hao ;Jiong Guo ;Fu Li
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1350-1364
    • /
    • 2023
  • 2D/1D coupling method is an important neutron transport calculation method due to its high accuracy and relatively low computation cost. However, 2D/1D coupling method may diverge especially in small axial mesh size. To analyze the convergence behavior of 2D/1D coupling method, a Fourier analysis for k-eigenvalue neutron transport problems is implemented. The analysis results present the divergence problem of 2D/1D coupling method in small axial mesh size. Several common attempts are made to solve the divergence problem, which are to increase the number of inner iterations of the 2D or 1D calculation, and two times 1D calculations per outer iteration. However, these attempts only could improve the convergence rate but cannot deal with the divergence problem of 2D/1D coupling method thoroughly. Moreover, the choice of axial solvers, such as DGFEM SN and traditional SN, and its effect on the convergence behavior are also discussed. The results show that the choice of axial solver is a key point for the convergence of 2D/1D method. The DGFEM SN based 2D/1D method could converge within a wide range of optical thickness region, which is superior to that of traditional SN method.

Application Analysis of Digital Photogrammetry and Optical Scanning Technique for Cultural Heritages Restoration (문화재 원형복원을 위한 수치사진측량과 광학스캐닝기법의 응용분석)

  • Han, Seung Hee;Bae, Yeon Soung;Bae, Sang Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5D
    • /
    • pp.869-876
    • /
    • 2006
  • In the case of earthenware cultural heritages that are found in the form of fragments, the major task is quick and precise restoration. The existing method, which follows the rule of trial and error, is not only greatly time consuming but also lacked precision. If this job could be done by three dimensional scanning, matching up pieces could be done with remarkable efficiency. In this study, the original earthenware was modeled through three-dimensional pattern scanning and photogrammetry, and each of the fragments were scanned and modeled. In order to obtain images from the photogrammetry, we calibrated and used a Canon EOS 1DS real size camera. We analyzed the relationship among the sections of the formed model, efficiently compounded them, and analyzed the errors through residual and color error map. Also, we built a web-based three-dimensional simulation environment centering around the users, for the virtual museum.

Light Emitting Diode with Multi-step Quantum Well Structure for Sensing Applications (계단형 양자우물 구조가 적용된 센서 광원 용 발광다이오드 소자)

  • Seongmin Park;Seungjoo Lee;Jajeong Woo;Yukyung Kim;Soohwan Jang
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.441-446
    • /
    • 2023
  • Electrical and optical characteristics of the GaN-based light-emitting diode (LED) with the improved multi-quantum well (MQW) structure have been studied for light source in bio-sensing systems. Novel GaN/In0.1GaN/In0.2GaN/In0.1GaN/GaN and Al0.1GaN/GaN/In0.2GaN/GaN/Al0.1GaN (MQW) structures were suggested, and their radiative recombination rate, light output power, electroluminescence, and external quantum efficiency were compared with those of the conventional GaN/In0.2GaN/GaN MQW structure using device simulation. The LED with the GaN/In0.1GaN/In0.2GaN/In0.1GaN/GaN MQW structure showed an excellent recombination rate of 5.57 × 1028 cm-3·s-1 that was more than one order improvement over that of the conventional LED. In addition, the efficiency droop was relieved by the suggested stepped MQW structure.