• Title/Summary/Keyword: Operation control

Search Result 9,565, Processing Time 0.038 seconds

An Experimental Environment for Simulation of Stealthy Deception Attack in CPS Using PLCitM (PLC in the Middle) (중간자 PLC를 이용한 CPS 은닉형 공격 실험환경 구축 방안)

  • Chang, Yeop;Lee, Woomyo;shin, Hyeok-Ki;Kim, Sinkyu
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.1
    • /
    • pp.123-133
    • /
    • 2018
  • Cyber-Physical System (CPS) is a system in which a physical system and a cyber system are strongly integrated. In order to operate the target physical system stably, the CPS constantly monitors the physical system through the sensor and performs control using the actuator according to the current state. If a malicious attacker performs a forgery attack on the measured values of the sensors in order to conceal their attacks, the cyber system operated based on the collected data can not recognize the current operation status of the physical system. This causes the delay of the response of the automation system and the operator, and then more damage will occur. To protect the CPS from increasingly sophisticated and targeted attacks, countermeasures must be developed that can detect stealthy deception attacks. However, in the CPS environment composed of various heterogeneous devices, the process of analyzing and demonstrating the vulnerability to actual field devices requires a lot of time. Therefore, in this study, we propose a method of constructing the experiment environment of the PLCitM (PLC in the middle) which can verify the performance of the techniques to detect the CPS stealthy deception attack and present the experimental results.

Design and Analsis of a high speed switching system with two priority (두개의 우선 순위를 가지는 고속 스윗칭 시스템의 설계 및 성능 분석)

  • Hong, Yo-Hun;Choe, Jin-Sik;Jeon, Mun-Seok
    • The KIPS Transactions:PartC
    • /
    • v.8C no.6
    • /
    • pp.793-805
    • /
    • 2001
  • In the recent priority system, high-priority packet will be served first and low-priority packet will be served when there isn\`t any high-priority packet in the system. By the way, even high-priority packet can be blocked by HOL (Head of Line) contention in the input queueing System. Therefore, the whole switching performance can be improved by serving low-priority packet even though high-priority packet is blocked. In this paper, we study the performance of preemptive priority in an input queueing switch for high speed switch system. The analysis of this switching system is taken into account of the influence of priority scheduling and the window scheme for head-of-line contention. We derive queue length distribution, delay and maximum throughput for the switching system based on these control schemes. Because of the service dependencies between inputs, an exact analysis of this switching system is intractable. Consequently, we provide an approximate analysis based on some independence assumption and the flow conservation rule. We use an equivalent queueing system to estimate the service capability seen by each input. In case of the preemptive priority policy without considering a window scheme, we extend the approximation technique used by Chen and Guerin [1] to obtain more accurate results. Moreover, we also propose newly a window scheme that is appropriate for the preemptive priority switching system in view of implementation and operation. It can improve the total system throughput and delay performance of low priority packets. We also analyze this window scheme using an equivalent queueing system and compare the performance results with that without the window scheme. Numerical results are compared with simulations.

  • PDF

A Case Study on the Traffic Operational Guidance for Temporary Closure of Climbing Lane; Focusing on Nakdong JC at Jungbunaeryuk Expressway (오르막차로 일시 폐쇄를 위한 교통운영기준 사례연구 (중부내륙고속도로 낙동JC를 중심으로))

  • Choi, Yoon-Hyuk;Lee, Seung-Jun;Bae, Young-Seok;Ko, Han-Geom
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.17-28
    • /
    • 2010
  • A climbing lane is installed to separate low-speed traffic from high-speed traffic if drastic traffic capacity reduction is expected due to a large number of vehicles that slow down in the upward section. Existing studies on climbing lanes have focused on the designation, location of starting and ending points, and installation method of climbing lane with regard to road design standards. However, in terms of traffic operation, it was known that the climbing lanes cause traffic congestion due to the increase of traffic volumes. In this regard, this study aims to establish traffic operational guidance as to how much effects temporary closure of climbing lanes can have on traffic improvement according to the volume-capacity ratio, grade, and composition of trucks. A test section of simulated climbing lane was selected in Nakdong JC bound for Masan(136.9K~133.3K, 3.6km, 3.7%) on Jungbunaeryuk expressway to conduct VISSIM analyses, microscopic traffic simulation based on such control variables as traffic volume(v/c), grade and the trucks ratio. As a result of the analyses, it has been found that v/c and the ratio of trucks are the key variables for efficient traffic management of climbing lanes in order to relieve traffic congestion via climbing lane. If ratio of trucks are more than 50% and when v/c would be 0.8, both climbing lane would be closed and non-operated regardless of grade and ratio of trucks when v/c is 1.0. With the increased traffic due to a five-day work week system, continued peak hours during the weekday, increased and various patterns of congestion on expressway, this study would be expected to contribute to facilitating researches on flexible operational standards for road facilities.

Practice and Improvement Scheme of Management of Human Resources in Korean Private Security Service Industry (한국 민간경비 인적자원 확보관리의 실태 및 개선방안)

  • Suh, Sang-Yul;Park, Jun-Seok
    • Korean Security Journal
    • /
    • no.16
    • /
    • pp.81-99
    • /
    • 2008
  • Despite its legal, systematic and quantitative growth, Korean private security has not been showing satisfactory level of qualitative growth comparing to quantitative growth as it socially shocked with recent occurrence of the events and accidents. People on demand of security are making use of private security service to offset insufficient supply of security power as, especially, the incendiarism at Sungryemun last February brought out security issues for nationally important facilities and cultural assets, and other cases showed that the police would not cope with the appropriate security services under the current security system for protecting the life and property of people. For the supplementation of security power, the private security service is prevalent, but lots of service providers would not overcome its small business scale, except some large-sized security providers. There are some problem occurred as some providers employed staff who would not have the stuff for performing security service and they even committed illegal actions. Some opinions pointed out that it should come up with measures as they socially lose their credit. Therefore, this research suggests the recognition of the importance and the improvement measures of human resources management as follows. Security Service needs: 1. control of criteria for the employment/recruitment of human resources; 2. inducement of qualitative improvement of security service by ensuring excellent quality of human resources; 3. elevation of morale of organizational members with the operation of efficient promotion system; 4. introduction of professional certification system for the inflow of excellent quality of human resources.

  • PDF

Analysis of Effects of Groundwater Abstraction on Streamflow for Sinduncheon Watershed (신둔천 유역에 대한 지하수 이용이 하천유량에 미치는 영향 분석)

  • Kim, Nam Won;Lee, Jeongwoo;Chung, Il Moon;Sung, Gee Youne
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.12
    • /
    • pp.1259-1273
    • /
    • 2012
  • In this study, a watershed-based surface water and groundwater integrated model, SWAT-MODFLOW was used to quantify the stream flow depletion due to groundwater pumping for the Sinduncheon watershed. Complex water use conditions such as water taken from a stream, sewage disposal release, irrigation from agricultural reservoir, groundwater pumping were considered for simulations. In particular, the model was revised to reflect the effects of reservoir operation and return flow from the used groundwater on streamflow variation. The simulated results showed that the groundwater pumping at current status has induced the decrease of more than 10% in annual average streamflow and 40% in drought flow at the outlet of the Sinduncheon watershed, The simulated results also revealed that the vast water withdrawals at green house areas during winter season have dramatically changed streamflow from April to June. The streamflow depletion was mainly attributed to pumping wells located within the distance of 300 m from the stream for Sinduncheon watershed.

Concept of Seasonality Analysis of Hydrologic Extreme Variables and Design Rainfall Estimation Using Nonstationary Frequency Analysis (극치수문자료의 계절성 분석 개념 및 비정상성 빈도해석을 이용한 확률강수량 해석)

  • Lee, Jeong-Ju;Kwon, Hyun-Han;Hwang, Kyu-Nam
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.8
    • /
    • pp.733-745
    • /
    • 2010
  • Seasonality of hydrologic extreme variable is a significant element from a water resources managemental point of view. It is closely related with various fields such as dam operation, flood control, irrigation water management, and so on. Hydrological frequency analysis conjunction with partial duration series rather than block maxima, offers benefits that include data expansion, analysis of seasonality and occurrence. In this study, nonstationary frequency analysis based on the Bayesian model has been suggested which effectively linked with advantage of POT (peaks over threshold) analysis that contains seasonality information. A selected threshold that the value of upper 98% among the 24 hours duration rainfall was applied to extract POT series at Seoul station, and goodness-fit-test of selected GEV distribution has been examined through graphical representation. Seasonal variation of location and scale parameter ($\mu$ and $\sigma$) of GEV distribution were represented by Fourier series, and the posterior distributions were estimated by Bayesian Markov Chain Monte Carlo simulation. The design rainfall estimated by GEV quantile function and derived posterior distribution for the Fourier coefficients, were illustrated with a wide range of return periods. The nonstationary frequency analysis considering seasonality can reasonably reproduce underlying extreme distribution and simultaneously provide a full annual cycle of the design rainfall as well.

Hand Hygiene Compliance of Healthcare Workers in a Children's Hospital (소아병원 종사자의 손 위생 수행)

  • Oh, Hyang Soon
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.3
    • /
    • pp.186-193
    • /
    • 2015
  • Purpose: The aim of study was to estimate the hand hygiene (HH) compliance of healthcare workers (HCWs) in a children's hospital. Methods: This study was conducted in a hospital which is a tertiary and educational children's hospital with 313 beds and 533 HCWs. Data were collected by direct observation methods from November 1, 2010 to December 31, 2010. Results: A total of 2,999 opportunities for HH were observed, and the overall HH rate was 95.3%. HH rate of the registered nurse, physicians and transferer was 97.7%, 89.2%, and 72.1%, respectively (P<0.001). Among physicians, HH rate of the fellows, professors, residents and interns was 97.5%, 93.9%, 89.7%, and 80.9%, respectively (P<0.001). HH rate in the emergency room, operation room, outpatient department (OPD), and the intensive care unit (ICU) was 97.2%, 97.2%, 95.4%, and 92.5%, respectively (P<0.001). Hand rubbing was the most frequently used (81.1%), and hand washing was frequently used in the case of 'after body fluids exposure risk' (37.7%) and 'after touching patient surroundings' (28.5%). HH methods were not statistically different from each departments (P =0.083), however, they were significantly different according to the World Health Organization (WHO) 5 Moments (P<0.001). Distributions in WHO 5 Moments by the job titles were significantly different (P<0.001). The odds ratio of physicians, ICU and OPD was 0.353 (95% CI, 0.241-0.519), 0.291 (95% CI, 0.174-0.487), and 0.484 (95% CI, 0.281-0.834), respectively. Conclusions: Compliance of HH was different by the job titles and departments. Effective custom-tailored HH programs for each job title and department need to be developed.

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.

Empirical Modeling of Lens Distortion in Change of Focal Length (초점거리 변화에 따른 렌즈 왜곡의 경험적 모델링)

  • Jeong, Seong-Su;Woo, Sun-Kyu;Heo, Joon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.1
    • /
    • pp.93-100
    • /
    • 2008
  • The parameters of lens such as focal length, focus, and aperture stop changes while shooting the scenes with zoom lens. Especially, zooming action dramatically changes the geometry of lens system that causes significant change of lens model. We investigated how the lens model changes while zooming in general shooting condition. Each parameters of lens model was estimated and checked whether they can be modeled well in the condition of auto-controlling focus, aperture and vibration reduction. In order to do this, calibration images were taken, modeled in different fecal length setting. And changing patterns of models were inspected to find out if there is some elements that have some particular pattern in changing with respect to focal length. The result showed us that although we didn't control the focus and aperture setting, there's specific changing patterns in radial and do-centering distortion. Especially, the strong linear correlation was found between coefficient of $r^2$ and focal length. It is expected that many parts of distortion can be eliminated without additional self calibration even if zoom operation is done when shooting the scenes if we know its fecal length and model of this coefficient.

Electrical Fire Disaster Prevention Device of Double Protection using a High Precision Current Sensor in Low Voltage Distribution System (고정밀 전류센서를 이용한 저압배전계통 이중 보호용 전기화재 방재장치)

  • Kwak, Dong-Kurl;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.40-47
    • /
    • 2009
  • Nowadays the diversity and large-capacity of electric appliances are strong effect on electrical fires augment in an alarming way. But, as the inactive response characteristics of the existing RCD (Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is confirmed the unreliability of the existing RCD by electrical fault simulator and is proposed a Electrical Fire Disaster Prevention Device (EFDPD) by using a high precision current sensor (namely, reed switch) for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The sensitive reed switch in the proposed EFDPD exactly detects the increased magnetic flux with the overload or the short current caused by a number of electrical faults, and the following, the EFDPD has double protection function which operates self circuit breaker or rapidly cuts off the existing RCD. The proposed EFDPD is confirmed the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker through various operation performance analysis. The proposed EFDPD can also prevent electrical disaster, like as electrical fires, which resulted from the malfunction and inactive response characteristics of the existing RCD.