• Title/Summary/Keyword: Operation Deviation

Search Result 427, Processing Time 0.039 seconds

A Study of Orthognathic Surgical Guides with Two-stage Split Path (2단 절개 형태를 가지는 악교정 수술 장치 연구)

  • Min Uk, Kim;Chung Hwan, Park;Ji Hyoung, Rho;Eui Sung, Jung;Young Sang, Park;Dong Guk, Kim;Yohan, Seo;Young Jea, Woo;Jong Min, Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.382-389
    • /
    • 2022
  • In this study, the accuracy of the orthognathic surgical guides with single-stage split path was upgraded to realize orthognathic surgical guides with two-stage split path and simulated surgery was performed to verify its accuracy. As a result, the average error distance between the simulation model and the scan model was + 0.289 / - 0.468 mm (standard deviation 0.128), which was confirmed to be within ± 0.5 mm, which is a clinically acceptable level. Also, there was no significant difference compared with the average value of + 0.313 / - 0.456 mm (average standard deviation 0.106) of the conventional single-stage split path type device. It is judged that the use of this device can contribute to the reduction of surgical time and increase in accuracy since a separate finishing operation for bone preparation is unnecessary.

Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides (제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드)

  • Kwon, Chang-Ryeol;Choi, Byung-Ho;Jeong, Seung-Mi;Joo, Sang-Dong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.271-278
    • /
    • 2012
  • Purpose: Recently implant surgical guides were used for accurate and atraumatic operation. In this study, the accuracy of two different types of surgical guides, positioning device fabricated and stereolithography fabricated surgical guides, were evaluated in four different types of tooth loss models. Materials and methods: Surgical guides were fabricated with stereolithography and positioning device respectively. Implants were placed on 40 models using the two different types of surgical guides. The fitness of the surgical guides was evaluated by measuring the gap between the surgical guide and the model. The accuracy of surgical guide was evaluated on a pre- and post-surgical CT image fusion. Results: The gap between the surgical guide and the model was $1.4{\pm}0.3mm$ and $0.4{\pm}0.3mm$ for the stereolithography and positioning device surgical guide, respectively. The stereolithography showed mesiodistal angular deviation of $3.9{\pm}1.6^{\circ}$, buccolingual angular deviation of $2.7{\pm}1.5^{\circ}$ and vertical deviation of $1.9{\pm}0.9mm$, whereas the positioning device showed mesiodistal angular deviation of $0.7{\pm}0.3^{\circ}$, buccolingual angular deviation of $0.3{\pm}0.2^{\circ}$ and vertical deviation of $0.4{\pm}0.2mm$. The differences were statistically significant between the two groups (P<.05). Conclusion: The laboratory fabricated surgical guides using a positioning device allow implant placement more accurately than the stereolithography surgical guides in dental clinic.

LED driver IC design for BLU with current compensation and protection function (전류보상 및 보호 기능을 갖는 BLU용 LED Driver IC설계)

  • Lee, Seung-Woo;Lee, Jung-Gi;Kim, Sun-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.1-7
    • /
    • 2020
  • In recent years, as LED display systems are actively spread, study on effective control methods for an LED driver for driving the systems has been in progress. The most representative among them is the uniform brightness control method for the LED driver channel. In this paper, we propose an LED driver IC for BLU with current compensation and system protection functions to minimize channel luminance deviation. It is designed for current accuracy within ±3% between channels and a channel current of 150 mA. In order to satisfy the design specifications, the channel amplifier offset was canceled out by a chopping operation using a channel-driving PWM signal. Also, a pre-charge function was implemented to minimize the fast operation speed and luminance deviation between channels. LED error (open, short), switch TR short detection, and operating temperature protection circuits were designed to protect the IC and BLU systems. The proposed IC was fabricated using a Magnachip 0.35-um CMOS process and verified using Cadence and Synopsys' Design Tool. The fabricated LED driver IC has current accuracy within ±1.5% between channels and 150-mA channel output characteristics. The error detection circuits were verified by a test board.

Optimal Value Detection of Irregular RR Interval for Atrial Fibrillation Classification based on Linear Analysis (선형분석 기반의 심방세동 분류를 위한 불규칙 RR 간격의 최적값 검출)

  • Cho, Ik-Sung;Jeong, Jong-Hyeog;Cho, Young Chang;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2551-2561
    • /
    • 2014
  • Several algorithms have been developed to detect AFIB(Atrial Fibrillation) which either rely on the linear and frequency analysis. But they are more complex than time time domain algorithm and difficult to get the consistent rule of irregular RR interval rhythm. In this study, we propose algorithm for optimal value detection of irregular RR interval for AFIB classification based on linear analysis. For this purpose, we detected R wave, RR interval, from noise-free ECG signal through the preprocessing process and subtractive operation method. Also, we set scope for segment length and detected optimal value and then classified AFIB in realtime through liniar analysis such as absolute deviation and absolute difference. The performance of proposed algorithm for AFIB classification is evaluated by using MIT-BIH arrhythmia and AFIB database. The optimal value indicate ${\alpha}=0.75$, ${\beta}=1.4$, ${\gamma}=300ms$ in AFIB classification.

A Study on Supportive State for Disabled Students of University Libraries in Seoul and Kyonggi (서울.경기 소재 대학도서관의 장애학생 지원 실태 조사)

  • Park, Hyun-Young;Nam, Tae-Woo
    • Journal of Information Management
    • /
    • v.39 no.1
    • /
    • pp.83-108
    • /
    • 2008
  • This thesis investigated disabled students' actual status of applying for university libraries. This thesis investigated how many times the university disabled students utilized the libraries, if facilities, apparatuses, materials, and regular employees were operated properly, and if they were established actually on the target at thirty private university libraries located at Seoul and Gyeonggi regions in operation of specially screening the objective students for special education in 2008. The investigation found that the general operation level of university libraries for disabled students were less than "medium"(average 2.38). As for utilization ratio, the most university students responded that "they didn't utilize libraries so many times(60%)". As for the response ratio of university library facilities and services, the most university students responded, "very insufficient", 99 items(32.27%), and the least university students responded, "very excellent", 28 items(7.0%). On the other hand, as for the analysis of each field, building facilities, in all of the items, were established more than "medium"(average 3.26), but material preparation level(average 1.8 point), employee education for softly supporting disabled students, and library utilization education on the target at disabled students(average 1.87) were less than "insufficient". Especially, the field of service was "insufficient level"(average 2.48), and standard deviation was more than 1.4. Manpower stationing and material delivery services have the biggest standard deviation between universities. So, this investigation found that university libraries reformed access to facilities a lot, but that its level of fundamental policy for library, such as materials, manpower, and the education on utilization, were in insufficient level.

A Study on the Standard Test Method for Thermal Resistance of Military Textile Thermal Insulator for Winter Season (방한을 목적으로 하는 군용 섬유제품 충전재의 보온성 시험방법에 대한 표준화 연구)

  • Yeo, Yong-heon;Hong, Seong-don;Lee, Min-hee;Kim, Kyung-pil;Chung, Il-han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.492-500
    • /
    • 2018
  • The performance evaluation of cold weather clothing is mainly carried out with thermal resistance. However, the results of the revised test method regarding the same specimen were decreased compare to previous one. In addition, there were deviations of the results among the authorized testing institutes according to the different interpretation of the KS test method. This makes it a considerable difficulty to the quality assurance of combat supplies. The purpose of this study is to minimize the variation of the results before and after the revision by analyzing the cause of the decrease in the heat insulation rate according to the revised test method. For this purpose, the difference between the test conditions before and after the revision of KS is analyzed and the possible results are reviewed. In addition, we want to minimize the result deviation between testing laboratories by analyzing the cause of the result deviation between test laboratories according to arbitrary interpretation of the standard. Based on this, we propose a standardized test method to prevent the decrease of the heat insulation rate by checking the pre-revision test method and the condition with the least deviation.

Reading Deviations of Glass Rod Dosimeters Using Different Pre-processing Methods for Radiotherapeutic in-vivo Dosimetry (유리선량계의 전처리 방법이 방사선 치료 선량 측정에 미치는 영향)

  • Jeon, Hosang;Nam, Jiho;Park, Dahl;Kim, Yong Ho;Kim, Wontaek;Kim, Dongwon;Ki, Yongkan;Kim, Donghyun;Lee, Ju Hye
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.92-98
    • /
    • 2013
  • The experimental verification of treatment planning on the treatment spot is the ultimate method to assure quality of radiotherapy, so in-vivo skin dose measurement is the essential procedure to confirm treatment dose. In this study, glass rod dosimeter (GRD), which is a kind of photo-luminescent based dosimeters, was studied to produce a guideline to use GRDs in vivo dosimetry for quality assurance of radiotherapy. The pre-processing procedure is essential to use GRDs. This is a heating operation for stabilization. Two kinds of pre-processing methods are recommended by manufacturer: a heating method (70 degree, 30 minutes) and a waiting method (room temperature, 24 hours). We equally irradiated 1.0 Gy to 20 GRD elements, and then different preprocessing were performed to 10 GRDs each. In heating method, reading deviation of GRDs at same time were relatively high, but the deviation was very low as time went on. In waiting method, the deviation among GRDs was low, but the deviation was relatively high as time went on. The meaningful difference was found between mean reading values of two pre-processing methods. Both methods present mean dose deviation under 5%, but the relatively high effect by reading time was observed in waiting method. Finally, GRD is best to perform in-vivo dosimetry in the viewpoint of accuracy and efficiency, and the understanding of how pre-processing affect the accuracy is asked to perform most accurate in-vivo dosimetry. The further study is asked to acquire more stable accuracy in spite of different irradiation conditions for GRD usage.

Location Prediction of Mobile Objects using the Cubic Spline Interpolation (3차 스플라인 보간법을 이용한 이동 객체의 위치 추정)

  • 안윤애;박정석;류근호
    • Journal of KIISE:Databases
    • /
    • v.31 no.5
    • /
    • pp.479-491
    • /
    • 2004
  • Location information of mobile objects is applied to vehicle tracking, digital battlefields, location based services, and telematics. Their location coordinates are periodically measured and stored in the application systems. The linear function is mainly used to estimate the location information that is not in the system at the query time point. However, a new method is needed to improve uncertainties of the location representation, because the location estimation by linear function induces the estimation error. This paper proposes an application method of the cubic spline interpolation in order to reduce deviation of the location estimation by linear function. First, we define location information of the mobile object moving on the two-dimensional space. Next, we apply the cubic spline interpolation to location estimation of the proposed data model and describe algorithm of the estimation operation. Finally, the precision of this estimation operation model is experimented. The experimentation comes out more accurate results than the method by linear function, although the proposed location estimation function uses the small amount of information. The proposed method has an advantage that drops the cost of data storage space and communication for the management of location information of the mobile objects.

Performance evaluation of a 400 W precise window motor for glass houses

  • Hong, Soon-Joong;Park, Soo-Bok;Kang, Na-Rae;Kim, Yong-Joo;Chung, Sun-Ok
    • Korean Journal of Agricultural Science
    • /
    • v.44 no.4
    • /
    • pp.595-603
    • /
    • 2017
  • Crop growth and production cost are greatly influenced by management of environmental factors such as ambient temperature, humidity, and $CO_2$, especially in protected horticulture. Opening and closing of greenhouses is the most important operation for control of these ambient environmental factors, and precise and stable operation requires high performance window motors. In this study, a 400 W precise window motor was constructed, and its performance was evaluated for plastic and glass greenhouses. First, the motor was designed and fabricated by benchmarking of an advanced foreign product. Then, the performance was evaluated through vibration, PCB (Process Control Block), and load tests. Vibration tests resulted in averaged vibration displacement and velocity of the developed motor of 0.002 mm and 0.2267m/s, which were statistically significantly different from those of the target motor. Average vibration acceleration ($0.26m/s^2$) of the developed motor was also significantly different from that ($0.51m/s^2$) of the target motor. PCB tests showed 2 - 4 mm deviation from the target values, and confirmed the operating status and precision of the control. Load tests with a 300 kg load also showed acceptable operating status and durability. Current values were $1.31{\pm}0.06A$ and RPMs were in the range of 2.9 - 3.0. Considering the above results, the developed window motor would be competitive to the target foreign product.

A Clinical Study on the Patients with Nasal Polyps (비용(鼻茸)환자에 대한 임상적 연구)

  • Lee, Sang-Moon;Hong, Seung-Ug
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.19 no.2
    • /
    • pp.180-191
    • /
    • 2006
  • Objectives : The purpose of this clinical report was to investigate the general characteristics of the patients with nasal polyps and estimate the efficacy of the oriental medical treatment on nasal polyps. Methods : We performed a clinical analysis of 50 patients who visited Kabsan oriental clinic due to nasal polyps. We inquired into distribution of age, sex, operation history related to nose, grade of nasal polyps, efficacy of treatment, etc. Results and Conclusions : 1. The sex ratio was 2.3 : 1. The average age was 40.02 years. 2. In the nasal operation history, inexperienced patients were 35 cases and experienced patients were 15 cases. 3. In the region of nasal polyps, there were 35 cases of bilateral types of nasal polyps, which is mon than in unilateral types. In the number of nasal polyps, multicentric types of 26 cases were similar in the number with solitary type of 24 cases. 4. In the predisposing or concomitant diseases, chronic sinusitis was the most frequent followed by allergic rhinitis, chronic rhinitis, septal deviation chronic otitis media, asthma, tonsilitis and allergic dermatitis. 5. In the main symptoms, nasal obstruction was the most important. In the concomitant symptoms, patients had frequent rhinorrhea, smell disturbance, postnasal drip, headache, etc. 6. The average treatment period was 3,58 months and the average number of treatment was 12.94 sessions. 1. In the amount of herbal medicine, 2 and 3 Ji(劑) were the most. The most frequently used herbal medicine to treat was Hyangbujamogeuntanggagam(香附子茅根湯加減) 8. In the change of grade after treatment, Grade I was the most. In the efficacy of treatment, 'good' was the most, followed by 'excellent' and 'uneffective'.

  • PDF