• Title/Summary/Keyword: Operating region

Search Result 866, Processing Time 0.024 seconds

Setting Method of a Percentage Current Differential Relay for Transformer Protection (변압기 보호용 전류비율차동 계전기의 동작영역 설정방법)

  • Kim, Su-Hwan;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.8-13
    • /
    • 2011
  • A percentage current differential relay is widely used for transformer protection. Because many percentage current differential relays recently use modified methods instead of conventional methods for deciding the operating characteristics of the large current region, in this paper, the operating region of a percentage current differential relay is analyzed in input-output current domain instead of operating-restraint current domain. An effective method to set the operating region when a CT is saturated is proposed with a series of investigations comparing a conventional method with the proposed modified method. The performance of the proposed method is evaluated for internal and external faults of a power transformer having the voltage rating of 345/154kV. EMTP-RV is used for the relaying data collection.

Advanced Field Weakening Control for Squirrel-Cage Induction Motor in Wide Range of DC-Link Voltage Conditions

  • Son, Yung-Deug;Jung, Jun-Hyung;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.665-673
    • /
    • 2017
  • This paper proposes a field weakening control method for operating an induction motor with a variable DC input voltage condition. In the variable DC voltage condition such as a battery, the field weakening method are required for the maximum output power. The conventional field weakening control methods can be used for operating the induction motor over the rated speed in a constant DC-link voltage condition. However, the conventional methods for operating the motor with the variable DC voltage is not suitable for the maximum output power. To overcome this problem, this paper proposes the optimized field weakening control method to extend the operating range of the induction motor with a rated power in a limited thermal and a wide DC input voltage conditions. The optimized d-axis and q-axis current equations are derived according to the field weakening region I and II to extend the operating region. The experimental results are presented to verify the effectiveness of the proposed method.

The Position of an Arago Disk System using Fuzzy Logic Control Technique (퍼지제어 기법을 이용한 아라고 원판 시스템의 위치 제어에 관한 연구)

  • Mun, Sang-Ik;Cho, Yong-Seok;Park, Ki-Heon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.709-711
    • /
    • 1999
  • In this paper, Fuzzy Logic Controller was Designed for the Degree control of Arago's disk system. Arago's disk system is an application of Arago's disk phenomenon which is the operating principle of induction motor. Since the Arago's disk system varies to stable region. maginally stable region, unstable region according to the degree of bar respectively, it is a sutable system which can be evaluate an efficiency of the system. While an existing controller which was designed using linearized system modeling could control the system on only one operating point, fuzzy logic controller has the advantage in showing good response for multi-operating points because it does not need system modeling.

  • PDF

Design of Composite Transistors with an Improved Operating Region (개선된 동작영역을 갖는 복합 트랜지스터 설계)

  • Lee, Geun-Ho;Yu, Yeong-Gyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.3A
    • /
    • pp.185-191
    • /
    • 2003
  • In this paper, we propose two CMOS composite transistors with an improved operating region by reducing the threshold voltage. The proposed composite transistorⅠand transistor Ⅱ employ a P-type folded composite transistor and a composite diode in order to decrease the threshold voltage, respectively. The limitation of the operating region of these transistors by current source is described. All circuits are simulated by Hsipice using 0.25㎛ n-well process with 2.5V supply voltage.

Hybrid Phase Excitation Method for Improving Efficiency of 7-Phase BLDC Motors for Ship Propulsion Systems

  • Park, Hyung-Seok;Park, Sang-Woo;Kim, Dong-Youn;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.761-770
    • /
    • 2019
  • This paper proposes a hybrid phase windings excitation method for improving the efficiency of a 7-phase brushless DC (BLDC) motor in the electric propulsion system of a ship. The electrical losses of a BLDC motor system depend on the operating region and the number of excited phase windings (2-phase, 4-phase or general 6-phase windings). In this paper the operating region and torque/speed characteristics according to the motor rotation speed and propeller load are analyzed for a number of excitation methods. In addition, it analyzes the electrical losses of the system under each of the excitation methods in the entire operating region of the motor. In every sampling time, the proposed control method calculates the electrical loss of the system for each of the excitation methods and operates a 7-phase BLDC motor by selecting the excitation method that results a decreased electrical loss at the operating speed. The usefulness of the proposed control algorithm is verified through experimental results.

Adaptive Error Concealment Technique using a Variable Operating Region Algorithm based on MPEG-4 Coding (연산 영역 가변 알고리즘을 적용한 MPEG-4 부호화 기반의 적응적 오류 은닉 기법)

  • 김병주;권기구;이석환;권성근;김봉석;이건일
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.1
    • /
    • pp.78-88
    • /
    • 2003
  • A novel adaptive error concealment technique is proposed using a variable operating region algorithm based on MPEG-4 coding. In the algorithm, a missing block is classified as flat or edge block based on local information from the surrounding blocks extracted using a Sobel operation in a variable operating region (VOR). In this case, the VOR is determined adaptively according to the number of edge directions in the missing block. 1;sing the classification, the flat blocks are then concealed by the Proposed mean based weighted bilinear interpolation (MWBLI) method, and the edge blocks by the boundary directional interpolation (BDI) method. Consequently, the use of the Proposed VOR improves the subjective performance in a curved edge region, while the adaptive processing based on block classification improves the objective performance. Experimental results confirmed that the proposed algorithm produced better results than conventional algorithms, both subjectively and objectively.

  • PDF

A Experimental Study on the Performance of an Axial-Type Suction-Blowing Fan (축류형 흡배송 송풍기의 성능에 관한 실험적연구)

  • Choi, Hyoung-Jun;Park, Young-Ha;Ahn, Kook-Young;Cho, Soo-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.19-24
    • /
    • 2011
  • An experimental study was conducted to examine the effectiveness of a suction-blowing fan that could not only remove polluted air by suction but also create the air-curtain by blowing. In order to create the air-curtain, rotors were installed on the surface of the shroud. These blows fresh air into the polluted region. The fresh air is spouted backward 45o on the basis of the axial direction using a double-ducted bellmouth. In the same suction operating condition, the suction region was extended by increasing the blowing velocity. However, the increasing rate of suction region was reduced when the blowing velocity was increased steadily. Thus, an efficient blowing velocity should be determined depending on the suction operating condition. In addition, the blowing requires additional input power. In a fixed suction operating condition, the input power was linearly increased in proportion to the blowing flowrate. When the suction-blowing fan was operated in the same input power as the suction fan, the suction region was increased more than 30% based on the 0.6m/sec velocity.

Investigation of Pressure Drop for a Pseudo-plastic Fluid Flow in Isosceles Triangle Pipes (이등변삼각형 단면을 갖는 파이프 내의 Pseudo-Plastic 유체유동에 대한 압력강하의 연구)

  • Lee, D.R.
    • Journal of Power System Engineering
    • /
    • v.13 no.2
    • /
    • pp.30-35
    • /
    • 2009
  • Numerical Calculations for dimensionless pressure drop (friction factor times Reynolds number) have been obtained for fully developed laminar flow of MPL(Modified Power Law) fluid in isosceles triangle pipes. The solutions are valid for Pseudoplastic fluids over a wide range from Newtonian behavior at low shear rates through transition region to power law behavior at higher shear rates. The analysis identified a dimensionless shear rate parameter which for a given set of operating conditions specifies where in the shear rate range a particular system is operating, i.e., Newtonian, transition or power law region. The numerical calculation data of the dimensionless pressure drop for the Newtonian and power law regions are compared with previously published asymptotic results presenting within 0.16 % in Newtonian region and 2.98 % in power law region.

  • PDF

Noise Diagram of an Automotive Turbo Charger and Its Applications (차량용 터보차져의 소음도표 작성 및 응용)

  • Lee, Hyeong-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.5
    • /
    • pp.502-509
    • /
    • 2010
  • A test facility which can simultaneously measure turbocharger operating condition variables and vibro-acoustic emission in the situations that are quite similar to real internal combustion engine operating conditions has been introduced. Using this facility, a new method sweeping from full open throttle to deep surge region along constant speed curves can be utilized instead of the stationary method that has been traditionally used to obtain turbocharger compressor maps. Data covering an extensive range of the compressor performance map have been collected and analyzed. An experimental study is performed to define a noise diagram that correlates vibro-acoustic measurements to aerothermodynamic operating conditions. An instrumentation set in the facility allows the automatic definition of the operating point on the turbine and compressor map of the turbocharger. Also, radiated sound pressure and casing vibration data corresponding to the point are obtained by a microphone in the vicinity of the compressor casing and an accelerometer on the casing. The major source(s) of noise at specific operating point on the map can be easily identified with these maps. Also, acoustic characteristics of a given turbocharger at the vicinity of the surge as well as in the surge are also defined. Finally, the possibility to define mild surge region of a turbocharger using vibro-acoustic measurements is studied.

Efficiency Analysis for the Community Culture Center in Capital region by DEA (DEA에 의한 수도권 소재 문화예술회관의 효율성 분석)

  • Joo, Hi-Yeob;Kim, Seung-Mo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.181-189
    • /
    • 2012
  • This research focus on Community Culture Center's efficiency according to the regional and operating subject in Capital region. Recently the importance and potential market of cultural industry is growing. In addition, as a basis for local cultural industries, the importance of Community Culture Center has been highlighted. Therefore, for the activation of cultural industry, Community Culture Center on the efficiency of the operation should be reconsidered. To analyze Community Culture Center, using DEA, the efficiency of public organizations tool, which focus on operational efficiency. Depending on the results of analysis, Seoul, Incheon and Gyeonggi province was able to confirm their efficiency. In addition, according to the Direct Operating, Industrial Operating, Foundation, Private Consignment Agency their efficiency showed significant results. Looking at regional Community Cultural Centers in Seoul and Gyeonggi Province will see that two are operating efficiently. On the other hand, the Community Cultural Center in Incheon was not efficiency. Looking at the operating entity basis, Direct Operating Agencies and Industrial Operating Agencies were operating efficiently. On the other hand, Foundation Act of agencies and Private Consignment Agencies have been operating relatively inefficiently.