• 제목/요약/키워드: Operating duty

검색결과 251건 처리시간 0.026초

무기체계 신뢰도 예측시 임무주기 적용 방안에 대한 연구 (Methodologies of Duty Cycle Application in Weapon System Reliability Prediction)

  • 윤희성;정다운;이은학;강태원;이승헌;허만옥
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제11권4호
    • /
    • pp.433-445
    • /
    • 2011
  • Duty cycle is determined as the ratio of operating time to total time. Duty cycle in reliability prediction is one of the significant factors to be considered. In duty cycle application, non-operating time failure rate has been easily ignored even though the failure rate in non-operating period has not been proved to be small enough. Ignorance of non-operating time failure rate can result in over-estimated system reliability calculation. Furthermore, utilization of duty cycle in reliability prediction has not been evaluated in its effectiveness. In order to address these problems, two reliability models, such as MIL-HDBK-217F and RIAC-HDBK-217Plus, were used to analyze non-operating time failure rate. This research has proved that applying duty cycle in 217F model is not reasonable by the quantitative comparison and analysis.

KTX 기장의 직무부하 경감을 위한 운전업무 개선 방안에 대한 연구 (A study on the improvement of operation process to lighten duty-load of the critical tasks of KTX train driver)

  • 전영록;이명길
    • 대한안전경영과학회지
    • /
    • 제10권4호
    • /
    • pp.47-56
    • /
    • 2008
  • This study suggest a way to improve duty process of KTX(Korea Train Express) high-speed train driver. A new operating system which based on safety was introduced to operate high-speed train which travel above 300km/h on the high-speed railroad but below 200km/h on the general railroad. There were some studies on the operation of high-speed train which travel on the high-speed railroad and on the general railroad with safety. However they overlooked the elements of human errors. The duty-load of KTX train driver's 14 basic operation processes was measured using NASA-TLX and found four processes with high duty-load. In this paper, critical tasks of the high duty-load processes are determined using a questionnaire. Some suggestions which include the improvement of facilities, operating system and operating skill are proposed to lighten duty-load of the critical tasks. The validity of the proposed new task processes is demonstrated by making question to KTX train driver. To use this results cost-benefit analysis, hazards analysis etc. should be performed additionally.

송전급 피뢰기용 ZnO 바리스터 소자의 전기적 특성 (Electrical Characteristics of ZnO Varistor for Transmission Class Arrester)

  • 김석수;박춘현;조이곤;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 반도체 재료 센서 박막재료 전자세라믹스
    • /
    • pp.179-182
    • /
    • 2004
  • ZnO varistor for transmission class arrester$({\Phi}65{\times}20mm)$ of 10kA(Class 3) grade was recently developed in korea and is tested for the properties by switching surge operating duty test to know the line discharge class and complex surge property in electric properties. To find out changing rate of residual voltage before and after lightning impulse residual voltage testing, the sample is cool to room temperature after finishing switching surge operating duty test, and the rate is good as 1.0~1.7%. The element had been considered as applicable ZnO varistor for electricity transmission from the test results of state conterl, switching surge operating duty, thermal stability and above test. But various test should be required for actual application because this is a part of the to be needed for application.

  • PDF

인버터 구동 원심펌프의 급수 사용율에 따른 에너지 절감 평가 (Evaluation of Energy Savings for Inverter Driving Centrifugal Pump with Duty Cycles)

  • 김경욱;서상호;라키부자만
    • 한국유체기계학회 논문집
    • /
    • 제18권6호
    • /
    • pp.81-85
    • /
    • 2015
  • The purpose of this study is to evaluate energy savings for inverter driving multi-stage centrifugal pump. Variable speed driving pump system has high efficiency compared with constant speed driving pump system. Because of difficulty to estimate operating efficiency of variable speed driving pump system, energy saving rates are used to replace operating efficiency. energy saving rates are calculated from pump input power and pump duty cycle. But another researches have used pump duty cycles of each season for energy saving rate. In this study, for estimating energy saving rate more high accuracy, pump duty cycles are measured for 1 year. pump duty cycles, depending on the season and be classified according to the weekday/weekend or during the week day. By this pump duty cycles, Energy saving rate is calculated appropriately.

Design of Multi-winding Inductor for Minimum Inductor Current Ripple Using Optimized Coupling Factor

  • Kang, Taewon;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.231-232
    • /
    • 2016
  • This paper investigates the design of multi-winding coupled inductor for minimum inductor current ripple. Based on the general circuit model of coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor of n-phase multi-winding coupled inductor which corresponds to a minimum inductor ripple current becomes -(1/n-1), i.e. a complete inverse coupling without leakage inductance, as the duty ratio of steady-state operating point approaches 1/n, 2/n, ${\cdots}$ or (n-1)/n. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the duty ratio of steady-state operating point approaches either zero or one. Therefore, coupled inductors having optimal coupling factor can minimize the ripple current of inductor and inductor size.

  • PDF

Analysis of Generalized n-winding Coupled Inductor in dc-dc Converters

  • Kang, Taewon;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.88-89
    • /
    • 2017
  • This paper investigates the design of multi-winding coupled inductor for minimum inductor current ripple in rapid traction battery charger systems. Based on the general circuit model of multi-winding coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor which corresponds to a minimum inductor ripple current becomes -(1/n-1), i.e. a complete inverse coupling without leakage inductance, as the steady-state duty ratio operating point approaches 1/n, 2/n, … or (n1)/n. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the steady-state duty ratio operating point approaches either zero or one.

  • PDF

Design of Three-winding Coupled Inductor for Minimum Current Ripple in Battery Chargers

  • Kang, Taewon;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.195-196
    • /
    • 2015
  • This paper investigates the design of coupled inductor for minimum inductor current ripple in rapid traction battery charger systems. Based on the general circuit model of coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor which corresponds to a minimum inductor ripple current becomes -0.5, i.e. a complete inverse coupling without leakage inductance, as the steady-state duty ratio operating point approaches 1/3 or 2/3. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the steady-state duty ratio operating point approaches either zero or one. Coupled inductors having optimal coupling factor can minimize the ripple current of inductor and battery current resulting in a reliable and efficient operation of battery chargers.

  • PDF

A 0.5-2.0 GHz Dual-Loop SAR-controlled Duty-Cycle Corrector Using a Mixed Search Algorithm

  • Han, Sangwoo;Kim, Jongsun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권2호
    • /
    • pp.152-156
    • /
    • 2013
  • This paper presents a fast-lock dual-loop successive approximation register-controlled duty-cycle corrector (SARDCC) circuit using a mixed (binary+sequential) search algorithm. A wider duty-cycle correction range, higher operating frequency, and higher duty-cycle correction accuracy have been achieved by utilizing the dual-loop architecture and the binary search SAR that achieves the fast duty-cycle correcting property. By transforming the binary search SAR into a sequential search counter after the first DCC lock-in, the proposed dual-loop SARDCC keeps the closed-loop characteristic and tracks variations in process, voltage, and temperature (PVT). The measured duty cycle error is less than ${\pm}0.86%$ for a wide input duty-cycle range of 15-85 % over a wide frequency range of 0.5-2.0 GHz. The proposed dual-loop SARDCC is fabricated in a 0.18-${\mu}m$, 1.8-V CMOS process and occupies an active area of $0.075mm^2$.

Optimized Coupling Factor for Minimizing Ripple Current of Coupled Inductor under Variable Duty in Rapid Traction Battery Charger

  • Kang, Taewon;Chae, Beomseok;Kang, Tahyun;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.335-336
    • /
    • 2014
  • This paper investigates the design of coupled inductor for minimum inductor current ripple in rapid traction battery charger systems. Based on the general circuit model of coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor which corresponds to a minimum inductor ripple current becomes -1, i.e. a complete inverse coupling without leakage inductance, as the steady-state duty ratio operating point approaches 0.5. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the steady-state duty ratio operating point approaches either zero or one. Coupled inductors having optimal coupling factor can minimize the ripple current of inductor and battery current resulting in a reliable and efficient operation of battery chargers.

  • PDF

듀티 제어가 적용된 3레벨 LLC 컨버터의 정상상태 및 소신호 모델링 (Steady State Analysis & Small Signal Modeling of Variable Duty Cycle Controlled Three Level LLC Converter)

  • 후세인 휴마라;김학원;조관열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.317-319
    • /
    • 2019
  • In this paper, a three level duty cycle controlled half bridge LLC converter for EV charger application is presented. The topology and operating regions of the converter are discussed. The equations of the converter are derived in time domain. A small signal model of the converter is developed by perturbation and linearization of the steady state model about their operating point using Extended Describing function.

  • PDF