• 제목/요약/키워드: Operating condition

검색결과 3,025건 처리시간 0.041초

축류형 흡배송 송풍기의 성능에 관한 실험적연구 (A Experimental Study on the Performance of an Axial-Type Suction-Blowing Fan)

  • 최형준;박영하;안국영;조수용
    • 한국유체기계학회 논문집
    • /
    • 제14권4호
    • /
    • pp.19-24
    • /
    • 2011
  • An experimental study was conducted to examine the effectiveness of a suction-blowing fan that could not only remove polluted air by suction but also create the air-curtain by blowing. In order to create the air-curtain, rotors were installed on the surface of the shroud. These blows fresh air into the polluted region. The fresh air is spouted backward 45o on the basis of the axial direction using a double-ducted bellmouth. In the same suction operating condition, the suction region was extended by increasing the blowing velocity. However, the increasing rate of suction region was reduced when the blowing velocity was increased steadily. Thus, an efficient blowing velocity should be determined depending on the suction operating condition. In addition, the blowing requires additional input power. In a fixed suction operating condition, the input power was linearly increased in proportion to the blowing flowrate. When the suction-blowing fan was operated in the same input power as the suction fan, the suction region was increased more than 30% based on the 0.6m/sec velocity.

보일러 터빈 시스템의 견실성에 관한연구 (A study on the robust control of the boiler-turbine)

  • 이시곤;김은기;권욱현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.192-196
    • /
    • 1988
  • This paper presents a feasibility study related to the design of a linear multivariable compensator for a model of boiler-turbine system. The nonlinear dynamics are linearized at a operating condition. At the operating point an LQG/LTR compensator is designed. Simulations are included to illustrate the usefulness of this linear multivariable control law.

  • PDF

고순도 압축공기 제조시스템의 흡착식 Dryer에서 에너지절감을 위한 운전방법에 관한 연구 (A Study on Operating Method to Save Energy from the Adsorption Dryer in the Process of Purifying Compressed Air)

  • 강석완;장성호;김현준;김성수;이영욱
    • 산업경영시스템학회지
    • /
    • 제39권3호
    • /
    • pp.180-191
    • /
    • 2016
  • Optimizing energy usage for maximum efficiency is an essential goal for manufacturing plants in every industrial manufacturing sector. The generation and distribution of purifying compressed air is a large expense incurred in practically all manufacturing processes. Not only is the generation and treatment expensive equipment of compressed air, but frequent maintenance and effective operation is also required. As a plant's compressed air system is often an integral part of the production process, it needs to be reliable, efficient, and easy to be maintain. In this paper, we study to find operating method to save energy from the adsorption dryer in the process of purifying compressed air, which is required for a clean room production site in "A" company. The compressed air passes through a pressure vessel with two "towers" filled with a material such as activated alumina, silica gel, molecular sieve or other desiccant material. This desiccant material attracts the water from the compressed air via adsorption. As the water clings to the desiccant, the desiccant particle becomes saturated. Therefore, Adsorption dryer is an extremely significant facility which removes the moisture in the air $70^{\circ}C$ below the dew point temperature while using a lot of energy. Also, the energy consumption of the adsorption dryer can be varied by various operating conditions (time, pressure, temperature, etc). Therefore, based on existing operating experiments, we have searched operating condition to maximize energy saving by changing operating conditions of the facility. However, due to a short experiment period (from September to October), further research will be focused on considering seasonality.

전자제품용 컴프레서의 가속열화시험에 관한 연구 (An Accelerated Degradation Test of a Electronics Appliance Compressor)

  • 이후진;윤원영
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제10권1호
    • /
    • pp.25-38
    • /
    • 2010
  • In this paper, an accelerated degradation test procedure for an electronic appliance compressor is proposed. We investigate the amount of wear of the compressor and consider several factors as accelerating factors. Finally we select the operating pressure as a main accelerating factor. The test condition of accelerated degradation test is determined. The modified accelerating test reduces the test time in design phase by using the suggested accelerating factor.

Single Address Space(SAS) Architecture를 이용한 Embedded Operating System (Embedded Operating System using the Single Address Space(SAS) Architecture)

  • 안광혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.608-611
    • /
    • 2003
  • A large part of the embedded system, compared with the PC, have low performance CPU and small memory. So the embedded operating system fits the condition of that hardware system. A Single Address Space (SAS) OS has the operating system and all applications in the single address space. The SAS architecture enhances sharing and co-operation, because addresses have a unique interpretation. Thus, pointer-based date structures can be directly communicated and shared between programs at any time, and can be stored directly on storage. The key point of the SAS OS on the embedded system is the low overhead inter-action between programs in process and usage. So SAS OS can be ported on the low performance CPU. In this paper, we design the SAS OS (named emNOS, Embedded Network Operating System) on the ARMTTDMI processor. Finally we show the benefits of the SAS OS on the embedded system.

  • PDF

Bio 필터를 이용한 Toluene 제거에서 미생물분해에 관한 연구 (A Study on Microbial Degradation for Removal of Toluene Vapour by Biofilter)

  • 하상안;강신묵
    • 환경위생공학
    • /
    • 제14권1호
    • /
    • pp.24-30
    • /
    • 1999
  • A biological filter for treatment of toluene among volatile organic compounds was studied. The investigation was conducted using specially built stainless steel columns packed with granular activated carbon and cold for removal of toluene. The G.A. and mold as filter material was also coated with Pseudomonas putida microorganisms.The biofilter unit was operated in the condition of moisture content vairation at gas loading rate of 12.5 l/min. Gaseous toluene taken from tedlar bag was analyzed by the use of G.C equipped with F.I.d detector. The removal efficiency of gaseous toluene was 95% at average inlet concentration of 950 ppm during bio-degradation operating condition. Effective removal efficiency was obtained with moisture content 27.5% at activated carbon and 32% at mold in this study. The effective operating condition were obtained with pH 6-8, temperature 28-42℃ for microbial degradation at gas loading rate of 12.5 l/min in packed material.

  • PDF

시동전류 제한을 통한 메탈헬라이드 램프용 안정기의 최적 설계 (A New Optimal Design Method of the Electronic Ballast for MHL with Stable Run-up Current)

  • 임병로;장목순;임기승;박종연
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.409-415
    • /
    • 2008
  • This paper proposed a new optimal design method of the electronic ballast with stable run-up current for Metal Halide lamp during the ignition condition. In order to avoid operation in the acoustic resonance frequency band and to supply the optimal ignition current without demage of inverter switching components during the ignition period, the values of the series inductor Ls, the series capacitor Cs, and the parallel capacitor Cp were determined by analysis of characteristics of inverter transfer function depend on Lamp operating power and resistance of ignition condition and steady state operating condition. For the prototype ballast for a 400W Metal Halide Lamp, experimental results are presented in order to validate the proposed method.

반응표면분석(反應表面分析)과 그의 전산화(電算化)

  • 박성현
    • 품질경영학회지
    • /
    • 제7권1호
    • /
    • pp.3-14
    • /
    • 1979
  • The primary objective of this paper is to aid the scientists and engineers in applying response surface procedures to obtain optimum operating conditions for many technical fields, particularly, for industrial manufacturing process. When a set of data is available from an experimental design, it is often of interest to fit a second order polynomial regression model in k independent variables, and find the condition of the independent variables (e. g., temperature, pressure, etc.) that optimize the response variable (e. g., yield, strength, etc.). This paper proposes a method how to obtain the optimum operating condition, and how 10 find the condition by using the computer. A computer program written in FORTRAN language is attached for the readers who may want to use the computer program.

  • PDF

비선형성 해석에 의한 화력발전소 터어빈 제어계통에 관한 연구 (The improvement of control strategy in thermal power plant turbine system by nonlinear analysis)

  • 황재호;이정준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.567-571
    • /
    • 1989
  • This paper describes the improvement of thermal power plant turbine control system by analyzing nonlinear characteristics. The turbine control depends on the frequency variation and boiler condition. The nonlinearity of turbine control is the result of governor/valve properties, steam condition and boiler thermal unbalance. Nonlinear analysis is divided into two; main steam valve position - turbine output anal governor response. Of course, every analysis must be done on considering plant operating condition. In this paper, after analyzing turbine control nonlinearity by numerical method and actual results, the sensitive operating load which corresponds to frequency is proposed, on guarranteed boiler stability. This idea is implemented at Pyung Tack thermal power plant, and the practical results are showed.

  • PDF

일체형원자로 주냉각재펌프의 검증시험 (Qualification Test of Main Coolant Pump for an Integral Type Reactor)

  • 박상진;윤의수;허필우;김덕종;오형우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.509-514
    • /
    • 2005
  • Main coolant pump (MCP) is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel rods and steam generators in an integral type reactor. The reactor is designed to operate under condition of 310 oC and 14.7 MPa. Thus MCP has to be tested under same operating condition as reactor design condition in order to verify its performance and safety. In present work, a test loop to simulate real operating situation of the reactor has been designed and constructed to test MCP. And then, as a part of qualification test, canned motor functional test and pump hydraulic performance test have been carried out upon a prototype MCP. Canned motor efficiency and pump hydraulic characteristics including homologous curves and NPSH curves were obtained from the qualification test.

  • PDF