• 제목/요약/키워드: Operating Capacity

검색결과 1,197건 처리시간 0.054초

Semi-pilot Scaled Hybrid Process Treatment of Malodorous Waste Air: Performance of Hybrid System Composed of Biofilter Packed with Media Inoculated with Thiobacillus sp. IW and Return-sludge and Photocatalytic Reactor (악취폐가스의 세미파일럿 규모 하이브리드 공정 처리: Thiobacillus sp. IW 및 반송슬러지를 접종한 담체를 충전한 바이오필터와 광촉매반응기로 구성된 하이브리드시스템의 운전)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • 제52권2호
    • /
    • pp.191-198
    • /
    • 2014
  • A semi-pilot hybrid system composed of a photocatalytic reactor and a biofilter was operated under various operating conditions in order to treat malodorous waste air containing both hydrogen sulfide and ammonia which are major air pollutants emitted from composting factories and many publicly owned treatment works (POTW). When both hydrogen sulfide and ammonia contained in malodorous waste air were treated simultaneously by a biofilter system, its performance of ammonia removal was much more poor than that by a biofilter system treating waste air containing only ammonia, unlike its performance of hydrogen sulfide removal. For semi-pilot hybrid system, the removal efficiencies of hydrogen sulfide and ammonia turned out to be ca. 83 and 65%, respectively. Therefore, for semi-pilot hybrid system, the removal efficiencies of hydrogen sulfide and ammonia was increased by ca. 4 and 30%, respectively, compared to those of semi-pilot biofilter system (control). In addition, the maximum elimination capacities of hydrogen sulfide and ammonia for semi-pilot hybrid system turned out to be ca. 60 and $37g/m^3/h$, respectively. These maximum elimination capacities of hydrogen sulfide and ammonia were estimated to be ca. 9.1% and ca. 23.3% greater than those for semi-pilot biofilter system (control), respectively. Therefore, the semi-pilot hybrid system contributed the enhancement of removal efficiency and the maximum elimination capacity of ammonia in a higher degree than that of hydrogen sulfide, compared to the semi-pilot biofilter system.

The Effect of Filter Media on the Biofiltration of Air Contaminated by Toluene (톨루엔으로 오염된 공기의 생물학적 여과에 대한 필터용 담체의 영향)

  • 홍성도;한희동;명성운;최호석;김인호
    • KSBB Journal
    • /
    • 제16권6호
    • /
    • pp.603-608
    • /
    • 2001
  • In this study, we studied on the remeval of toluene vapors in a lab-scale biofilter. Biofiltration was performed in a column fed downflow with contaminated air at ambient conditions. The column was packed with mixture of Peat and Calstene(5:3 vol. Ratio), Synthesized media, Bark and Wood chip, which were inoculated with microbial population of selected stains(Pseudomonas. putida, KCCM 11343, ATCC 12633). The microorganisms were immobilized on the bed medium and then biofilm were formed. The biofilter was operated under the conditions of various inlet toluene concentrations for 180 days and treated up to the elimination capacity of maximum 40 g/㎥hr at the inlet load of 30 g/㎥ hr with percentage removals of 20∼90% and gas retention times between 1 and 2 min. The pressure drop was very negligible through the biofilter columps because its value of 0.054 cmH$_2$O/m was much less than others. The effect of operating conditions such as flow rate, inlet toluene concentration and moisture contents on the performance of the biofilter was sequentially investigated in this study.

  • PDF

Recognition of Free Inquiry Activity and its Effects on the Science Inquiry Ability of Middle School Students (자유 탐구 활동에 대한 중학생들의 인식 및 자유 탐구 활동이 중학생들의 과학 탐구능력에 미치는 영향)

  • Byun, Sun-Mi;Kim, Hyun-Joo
    • Journal of The Korean Association For Science Education
    • /
    • 제31권2호
    • /
    • pp.210-224
    • /
    • 2011
  • The purpose of this study is to analyze students' recognition of the free inquiry activity and to investigate what effect the free inquiry activity of the 2007 Revised Educational curriculum revision has on the science inquiry ability of middle school students. To conduct the research we worked with 262 female students, 8 classes of first graders in a middle school. Among them, 4 classes were taught in free inquiry activity and the remaining 4 classes were taught in the traditional way. The results of Likert-questionnaire indicate that students were learning about cooperative spirit through group investigation activities and discussions and did not take the free inquiry activity as a hard activity. Also they showed positive reaction agreeing that this activity is both a helpful method in learning science and interesting. However, it seemed that the investigation tends to flow between the leading 1~2 members of the group and showed difficulty in carrying out the investigation as a group after school hours. It showed there are few problems and obstacles in operating the free inquiry activity. The free inquiry activity did not give any meaningful influence on the improvement of science inquiry ability of students. Integrative inquiry process skills did not give a relevant influence, however, it showed a meaningful influence on the improvement of basic inquiry process skills. Especially, among the low-ranking element of basic inquiry process skills, it enhanced the capacity for prediction.

Evaluation of Vehicle and Pedestrian Environments using Grey System Theory (Grey System Theory를 이용한 차량 및 보행환경 통합평가)

  • Lee, Jin-Gak;Son, Yeong-Tae;Han, Sang-Jin;Park, Jin-Yeong;Lee, Sang-Hwa
    • Journal of Korean Society of Transportation
    • /
    • 제28권4호
    • /
    • pp.141-156
    • /
    • 2010
  • In this paper, understanding there is a limitation with a comprehensive and network approach for the evaluation of existing vehicle and pedestrian environments, the authors focus on developing an integrated approach to assessing these environments. The network evaluation here means the assessment at a three-dimensional level that includes evaluation methods of lines/axes in a spatial concept as well as integration of evaluation indicators being used for vehicles and the walking environment. Grey System Theory (GST) was applied based on the theoretical background for network and comprehensive integrated evaluation, and the evaluation of the vehicle and pedestrian environment was performed by assigning target areas to walking preference zones. As a result of the comprehensive evaluation and analysis by GST, even if the service level is the same as the operating indicators (Highway Capacity Manual) of the vehicle and pedestrian environment, or relatively better, it was identified that the total score could be varied over Grey Category because the observed data are calculated after considering the weights between evaluation indicators by the range of Grey Category on the comprehensive evaluation. Considering comprehensively these points, although the indicators on the operation of roads are relatively good, in the event that the indicators on the safety of roads are bad, it was known that the scores over Grey Category also could be changed. The result is that this evaluation method can be used to evaluate the network concept per lane (per axis) as well as to diagnose the current state by type of urban street in the future.

Analytical Study on the Prying Action Force and Axial Tensile Stiffness of High-Strength Bolts Used in an Unstiffened Extended End-Plate Connection (비보강 확장단부판 접합부에 체결된 고장력볼트의 지레작용력 및 축방향 인장강성에 대한 해석적 연구)

  • Kim, Hee Dong;Yang, Jae Guen;Lee, Hyung Dong
    • Journal of Korean Society of Steel Construction
    • /
    • 제27권2호
    • /
    • pp.251-260
    • /
    • 2015
  • The end plate connection is applied to beam-column moment connections in various forms. Such end plate connection displays changes in the behavioral characteristics, strength and stiffness, and energy dissipation capacity based on the thickness and length of the end plate, the number and diameter of the high strength bolt, the gauge distance of the high strength bolt, prying action force of the high strength bolt, and dimensions and length of the welds. Accordingly, this study has apprehended the axial tensile stiffness and prying action force of the high strength bolt connected on the tensile side based on the difference in thickness of the end plate, and was conducted to propose an analysis model for the prediction of such variables that affect the operating properties of the end plate. To achieve this, this study has conducted a three-dimensional non-linear finite-element analysis of the unstiffened expanding end plate connection by selecting only the thickness of the end plate as the variable.

Fabrication of IMT-2000 Linear Power Amplifier using Current Control Adaptation Method in Signal Cancelling Loop (신호 제거 궤환부의 전류 제어 적응형 알고리즘을 이용한 IMT-2000용 선형화 증폭기 제작)

  • 오인열;이창희;정기혁;조진용;라극한
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제40권1호
    • /
    • pp.24-36
    • /
    • 2003
  • The digital mobile communication will be developed till getting multimedia service in anyone, any where, any time. Theses requiring items are going to be come true via IMT-2000 system. Transmitting signal bandwidth of IMT-2000 system is 3 times as large as IS-95 system. That is mean peak to average of signal is higher than IS-95A system. So we have to design it carefully not to effect in adjacent channel. HPA(High Power Amplifier) located in the end point of system is operated in 1-㏈ compression point(Pl㏈), then it generates 3rd and 5th inter modulation signals. Theses signals affect at adjacent channel and RF signal is distorted by compressed signal which is operated near by Pl㏈ point. Then the most important design factor is how we make HPA having high linearity. Feedback, Pre-distorter and Feed-forward methods are presented to solve theses problems. Feed-forward of these methods is having excellent improving capacity, but composed with complex structure. Generally, Linearity and Efficiency in power amplifier operate in the contrary, then it is difficult for us to find optimal operating point. In this paper we applied algorithm which searches optimal point of linear characteristics, which is key in Power Amplifier, using minimum current point of error amplifier in 1st loop. And we made 2nd loop compose with new structure. We confirmed fabricated LPA is operated by having high linearity and minimum current condition with ACPR of -26 ㏈m max. @ 30㎑ BW in 3.515㎒ and ACLR of 48 ㏈c max@${\pm}$㎒ from 1W to 40W.

A study on appropriate ship power system for pulse load combine with secondary battery (펄스부하에 적합한 이차전지 연동형 선박 전력시스템에 관한 연구)

  • Oh, Jin-Seok;Lee, Hun-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권8호
    • /
    • pp.962-968
    • /
    • 2013
  • Problem of greenhouse gases associated with global warming and the world rise in fuel oil prices due to the depletion of fossil fuel has attracted attention. For this reason, maritime transport business, has shown interest in green-ship technology to reduce the consumption of fuel and reduce greenhouse gas for environmental protection. Power system of the ship is one of the most important factors for safe operation. Therefore, at design of ship power system, most of existing vessel used comparative large capacity generator in order to respond peak load such as bow thruster, crane and etc. In the navigation of ship, marine generators most would be operated at low load operation. In the low load operation of the generation rate of 50% or less, the operation efficiency of the generator it deteriorated, to consume more fuel oil. It also, it means that adversely effect the life of the generator. In this paper, studied how to apply for a secondary battery in container ship that relatively frequent arrival and departure in port. As a result, in order to apply the secondary battery to increase the operating efficiency of the generator during the voyage, it was confirmed that it is possible to reduce fuel consumption.

An Analysis on the Bleeding Effect of SCW Ground Heat Exchanger using Thermal Response Test Data (열응답시험 데이터를 이용한 SCW형 지중열교환기 블리딩 효과 분석)

  • Chang, Keun-Sun;Kim, Min-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제21권1호
    • /
    • pp.512-520
    • /
    • 2020
  • Recently, the applications of the standing column well (SCW) ground heat exchanger (GHX) have increased significantly in Korea as a heat transfer mechanism of ground source heat pump systems (GSHP) because of its high heat capacity and efficiency. Among the various design and operating parameters, bleeding was found to be the most important parameter for improving the thermal performance, such as ground thermal conductivity and borehole thermal resistance. In this study, a bleeding analysis model was developed using the thermal response test data, and the effects of bleeding rates and bleeding locations on the thermal performance of anSCW were investigated. The results show that, when the ground water flows into the top of anSCW, the time variation of circulating water temperature decreased with increasing bleeding rate, and the ground thermal conductivity increases by as much as 179% with a 30% bleeding rate. When the ground water flows into the bottom of the SCW, the circulating water temperatures become almost constant after the increase in the beginning time because the circulating water exchanges heat with the ground structure before mixing with the ground water at the bottom.

Selection of the Best Oxygen Carrier Particle for Syngas Fueled Chemical-Looping Combustor (합성가스 연소 매체순환식 가스연소기 적용을 위한 최적 산소공여입자 선정)

  • Ryu, Ho-Jung;Kim, Ji-Woong;Jo, Wan-Kuen;Park, Moon-Hee
    • Korean Chemical Engineering Research
    • /
    • 제45권5호
    • /
    • pp.506-514
    • /
    • 2007
  • To select the best oxygen carrier particle for syngas fueled chemical-looping combustor, the reduction reactivity and carbon deposition characteristics were determined in a thermogravimetric analyzer. Four kinds of oxygen carrier particles (NiO/bentonite, $NiO/LaAl_{11}O_{18}$, $Co_xO_y/CoAl_2O_4$, $NiO/NiAl_2O_4$) were tested with the simulated syngas (30% $H_2$, 10% $CO_2$, 60% CO) as a reduction gas. With each of these particles, the maximum conversion and oxygen transfer capacity increase with increasing the reduction temperature At the given experimental range, the optimum operating temperature to maximize oxygen transfer rate is found to be $900^{\circ}C$ and carbon deposition on the particles could avoid at the temperature above $800^{\circ}C$. Among four kinds of oxygen carrier particles, the NiO-based particles exhibits better reactivity than the CoO-based particle. Moreover, the NiO/bentonite particle produces the best reactivity based on the oxygen transfer rate and the degree of carbon deposition. The measured oxygen transfer rate increases as the metal oxide content in NiO/bentonite particle is increased thereby higher metal oxide contents could provide stable operation of chemical-looping combustor.

Development of an Apparatus for Vertical Transfer of a PRT Vehicle Operating on a Road Network (운행 중인 PRT 차량의 수직이송을 위한 장치 개발)

  • Kang, Seok-Won;Um, Ju-Hwan;Jeong, Rag-Gyo;Kim, Jong-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제14권6호
    • /
    • pp.2604-2611
    • /
    • 2013
  • The Personal Rapid Transit(PRT) system has been highly interested in future transportation developments due to its on-demand and optimized door-to-door transport capability. However, the major impediments to the commercialization of PRT are the high cost for construction of infrastructures as opposed to the small transport capacity and difficulty in defining the role of PRT in building a balanced transportation system. In this study, the vertical transfer device for the PRT vehicle is developed to provide more flexible and better compatible urban mobility services between means of transportation, which is expected to meet particular demands in a particular environment. This apparatus was initially designed based on the basis of vertical circulating conveyors with steel chains, which is frequently used in logistics. Its advantages are capable of the non-stop loading and reduced head-way time. Most importantly, it was intensified by the additional idea to ensure the stable and reliable transfer of the PRT vehicle fully loaded with passengers. The 1/10-scale prototype was successfully tested to demonstrate a fundamental mechanism of vertical transfer and identify unexpected user requirements prior to a real manufacturing process.