• 제목/요약/키워드: Open-cut

검색결과 244건 처리시간 0.023초

국내 중소건설업체의 해외 진출 활성화를 위한 건설 보증 확대 방안에 관한 연구 (A Study on the Methodology to Performance Security on the Korea Small/Medium Sized Construction Firms for Venturing into International Market)

  • 안형준;김주형;김재준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.225-229
    • /
    • 2009
  • International construction market has been open to other countries, and it derives the development of our overseas construction industry quantitatively as well as qualitatively. Until now, the major companies have an absolute majority in the overseas construction market, and the small and medium enterprises have had difficulty to get a leadership in the international construction market because of the lack of the technical expertise and the capital strength. Especially in the Middle East Asia, our construction companies has touched off a boom, so our market share also has grown, which derived from the up toward ratchet oil prices and a worldwide boom in real estate development. The small and medium enterprise minority have recognition that the overseas construction market is the major company's native territory. But Data from the existing researches and many statistics indicate the most companies tend to underestimate the capacity and international competitiveness of the small and medium enterprises. As a matter of fact, hundreds of small and medium enterprise cut a conspicuous figure in overseas market. Consequently, it is indispensable to overcome the international financial crisis by revitalizing our overseas construction industry which obtains excellent results in international market. this study suggested the ways to expand overseas bonding capacity of Korean financial institution. This study proposed the Korean government to allow Construction Guarantee (former Korea Construction Financial Cooperative) to deal with foreign exchange so that Construction Guarantee will underwrite the overseas construction bond.

  • PDF

Preparation of Atomically Flat Si(111)-H Surfaces in Aqueous Ammonium Fluoride Solutions Investigated by Using Electrochemical, In Situ EC-STM and ATR-FTIR Spectroscopic Methods

  • Bae, Sang-Eun;Oh, Mi-Kyung;Min, Nam-Ki;Paek, Se-Hwan;Hong, Suk-In;Lee, Chi-Woo J.
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권12호
    • /
    • pp.1822-1828
    • /
    • 2004
  • Electrochemical, in situ electrochemical scanning tunneling microscope (EC-STM), and attenuated total reflectance-FTIR (ATR-FTIR) spectroscopic methods were employed to investigate the preparation of atomically flat Si(111)-H surface in ammonium fluoride solutions. Electrochemical properties of atomically flat Si(111)-H surface were characterized by anodic oxidation and cathodic hydrogen evolution with the open circuit potential (OCP) of ca. -0.4 V in concentrated ammonium fluoride solutions. As soon as the natural oxide-covered Si(111) electrode was immersed in fluoride solutions, OCP quickly shifted to near -1 V, which was more negative than the flat band potential of silicon surface, indicating that the surface silicon oxide had to be dissolved into the solution. OCP changed to become less negative as the oxide layer was being removed from the silicon surface. In situ EC-STM data showed that the surface was changed from the initial oxidecovered silicon to atomically rough hydrogen-terminated surface and then to atomically flat hydrogenterminated surface as the OCP moved toward less negative potentials. The atomically flat Si(111)-H structure was confirmed by in situ EC-STM and ATR-FTIR data. The dependence of atomically flat Si(111)-H terrace on mis-cut angle was investigated by STM, and the results agreed with those anticipated by calculation. Further, the stability of Si(111)-H was checked by STM in ambient laboratory conditions.

미만성 침윤성 폐질환을 보이는 환자에서 방사선투시유도 절단침 폐생검의 유효성 (Efficacy of Fluoroscopy-Guided Cutting Needle Lung Biopsy in Patients with Diffuse Infiltrative Lung Disease)

  • 최수전;신은아;김정숙
    • Tuberculosis and Respiratory Diseases
    • /
    • 제70권1호
    • /
    • pp.43-50
    • /
    • 2011
  • Background: Open lung biopsy is used for diagnosis of diffuse infiltrative lung diseases (DILD), but it is invasive and relatively expensive procedure. Fluoroscopy-guided cutting needle lung biopsy (FCNLB) has merits of avoidance of admission and rapid diagnosis. But diagnostic accuracy and safety were not well known in the diagnosis of DILD. Methods: We included 52 patients (37 men, 15 women) having DILD on HRCT with dyspnea, except the patients who could be confidently diagnosed with clinical and HRCT findings. FCNLB was performed using 16G Ace cut needle (length 1.5 cm, diameter 2 mm) at the area of most active lesion on HRCT. Final diagnoses were made by the consensus. Results: The mean interval between the HRCT and FCNLB was 4.5 days. Most cases were performed one biopsy during 5~10 minutes. Specific diagnosis was obtained in 43 of 52 biopsies (83%). The most common diagnosis was nonspecific interstitial pneumonia (11 cases) and followed by cryptogenic organizing pneumonia (7 cases), diffuse alveolar hemorrhage and usual interstitial pneumonia (5 cases in each), hypersensitivity pneumonitis (3 cases), tuberculosis and drug induced interstitial pneumonitis (2 cases in each), the others are in one respectively. Mild complication was developed in 9 patients (8 pneumothorax, 1 hemoptysis). Most of complications were regressed without treatment except one case with chest tube insertion for pneumothorax. Conclusion: Fluoroscopy-guided 16 G cutting needle lung biopsy was an useful method for the diagnosis of DILD.

압연 방향을 적용한 자체 진단형 고효율 네온관용 변압기 (Development of High Efficiency Self Diagnosis Type Neon Transformer using Groin Direction of Non-Oriented Silicon Steel Strip)

  • 변재영;김윤호
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.17-24
    • /
    • 2003
  • 본 논문에서는 네온 변압기의 효율을 높이기 위하여 주 자속과 누설 자속의 흐름을 분석하고, 이에 따른 압연 방향과 주 자속과의 방향을 최대한 일치 시켜서 자속에 의한 손실을 최소화 하고 역율을 향상시킨 고효율의 네온관용 변압기를 제시 하였다. 그리고 정격 부하시, 단락시 및 무부하시의 각각의 자속 분포를 해석하고 이를 응용하여 부하측 이상 발생시 즉시 전원이 차단될 수 있는 전자식 차단 장치를 개발부착 하였다. 즉 네온관의 파손이나 누전으로 인한 화재나 인체 감전의 위험을 사전에 방지 할 수 있는 전자식 보호 기능을 내장한 자체 진단형의 무방향성 코어의 압연 방향성을 고려한 고효율의 네온관용 변압기를 구현하였다.

경남 사천시 서포면 동쪽 해안단구 지형 발달과 분포 체계 (Geomorphic development and distributional system of marine terrace in the eastern part of Seopo-myeon, Sacheon-si, Gyeongnam Province)

  • 윤순옥;강봉;박충선;황상일
    • 한국지역지리학회지
    • /
    • 제22권4호
    • /
    • pp.875-886
    • /
    • 2016
  • 남해안의 사천시 서포면 동쪽 해안은 창선도와 남해도에 의해 외해와 거의 완전하게 단절된 내만이다. 이 지역의 해안단구는 형성 시기를 달리하는 해발고도 10~12m, 15~18m, 20~24m, 25~28m, 30~33m, 35~38m, 40~45m, 45~50m, 54m 지형면으로 구분된다. 이와 같은 해안단구 체계는 서해안 보령 지역의 것과 유사하다. 지형면은 구릉지의 능선을 따라 분포하며 면적이 대체로 좁다. 그리고 형성된 지 오래된 지형면과 상대적으로 젊은 지형면이 혼재되어 분포한다. 이와 같은 해안단구 공간 분포 특징은 오래된 지형면이 가장 내륙쪽에서 해안선에 평행하게 나타나며 해안으로 갈수록 최근에 만들어진 지형면이 나타나는 동해안과는 대조적이다. 이것은 기복이 복잡한 구릉지에 태풍에 의해 형성된 강력한 에너지를 갖는 파랑이 짧은 기간 동안 파식대를 형성한 데 기인한다.

  • PDF

2차처리장 방류수 정화 부들습지셀의 초기운영단계 질산성질소 제거 (Nitrate Removal of a Cattail Wetland Cell Purifying Effluent from a Secondary-Level Treatment Plant During Its Initial Operating Stage)

  • 양홍모
    • 한국환경농학회지
    • /
    • 제23권4호
    • /
    • pp.228-233
    • /
    • 2004
  • Nitrate removal was examined from May to October 2003 of a surface flow treatment wetland cell, which was a part of a treatment wetland system composed of four wetland cells and a distribution pond The system was established on rice paddy near the Kohung Estuarine Lake located in the southern part of the Korean Peninsula. Effluent from a secondary-level night soil treatment plant was funneled into the system. The investigated cell, 87 m in length and 14 m in width, was created in April 2003. An open water was designed at its center, which was equivalent to 10 percent of its total area. Cattails (Typha angustifolia) were transplanted from natural wetlands into the cell and their stems were cut at about 40cm height from their bottom ends. Average $25.0\;m^3/day$ of effluent from the treatment plant was funneled into the cell by gravity flow and average $24.1\;m^3/day$ of its treated effluent was discharged into the Sinyang Stream flowing into the lake. Its water depth was maintained about 0.2 m and its hydraulic detention time averaged 5.2 days. Average height of the cattail stems was 42.5 cm in May 2M3 and 117.7 cm in September 2003. The number of stems averaged $9.5\;stems/m^2$ in May 2003 and $16.4\;stems/m^2$ in September 2003. The growth of cattails was good. Temperature of influent and effluent averaged 25.9 and $26.7^{\circ}C$, respectively. $NO_3$-N loading rate of influent and effluent averaged 176.67 and $88.09\;mg/m^2\;day$, respectively. Removal of rf03-N averaged $89.58\;mg/m^2\;day$ and its removal rate by mass was about 50%. Considering its initial operating stage in which cattail rhizomes and litter layer on the bottom were not Idly established, the $NO_3$-N removal rate of the cell was rather good.

인버터식 고효율 네온관용 변압기 (Inverter type High Efficency Neon Transformers for Neon Tubes)

  • 변재영;김윤호
    • 조명전기설비학회논문지
    • /
    • 제16권6호
    • /
    • pp.22-29
    • /
    • 2002
  • 무방향성 규소강판을 사용한 자기식 네온관용 변압기는 내구성이 좋은 반면에 용량에 따른 규소 강판의 무게가 무겁고 외형이 큰 관계로 네온관 설치 작업 시 상당히 불편한 점이 많다. 또한 네온관의 다양한 디스플레이 제어성면에서도 비합리적 이었다. 이를 개선하기 위한 방법으로 네온 트랜스포머의 전원장치 및 2차측 고압 출력부를 고속의 고주파 스위칭 파워 트랜지스터(MOSFET)를 이용하여 상용주파수 60[Hz]를 고속 스위칭 제어를 통하여 20[KHz]의 고주파로 변환시킨후, 네온관을 방전시키기 위한 고전압을 발생시키는 인버터식 네온관용 변압기를 구현하였다. 또한 네온관의 파손이나 누전으로 인한 화재나 인체 감전의 위험을 사전에 방지할 수 있는 보호회로 GFCI(Ground Fault Circuit Interrupter)를 제안 하였다.

개착식 하상여과에서 여재 구성에 따른 탁도 저감 효율 분석: Lab Scale 실험을 통한 접근 (Analysis of Turbidity Reduction Efficiency according to the Configuration of Filter Media in Open-cut River Bed Infiltration Process : Lab Scale Experiment)

  • 양정석;김일환;이재범;정재훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.515-515
    • /
    • 2017
  • 하천에서 취수원을 개발하는데 있어 지층의 구성으로 물리, 화학적 여과, 흡착 등을 통해 자연 정화되는 간접 취수 방식이 활발히 도입되고 있다. 양질의 취수원을 공급할 수 있는 간접 취수 방식은 수량 확보 측면에서의 불확실성과 유지관리상의 어려움 때문에 많은 시행착오가 발생된다. 이와 같은 단점을 개선하기 위해 하상을 개착하여 불균질한 대수층을 치환하고 스크린을 통해 간접 취수원을 개발하는 하상여과 방식이 도입되고 있다. 대수층을 치환하여 여재를 구성함에 있어 오염물질 및 탁도의 저감 효율을 극대화하기 위해 다양한 연구가 진행되고 있다. 본 연구에서는 개착식 하상여과에서 치환하는 여재의 구성에 따른 탁도의 저감 효율을 분석하기 위해 축소 모형실험으로 구성하였다. 각각의 여재의 구성에 대해서는 상수도 시설기준을 통해 축소된 입경의 매질로 구성하였다. 실험실 규모의 모형 수조($1500mm{\times}500mm{\times}1700mm$)를 구성하고 하부에는 내경 80mm이고 길이 1300mm인 기능성 스크린이 부착된 취수관을 설치하였다. 모형 수조에서 여재의 두께는 총 1000mm로 구성하였고, 각각의 층에 대해서는 250mm로 하여 4개의 층을 구성할 수 있도록 하였다. 치환하는 여재의 매질에는 자갈, 왕사, 중사, 화산석을 사용하였고, 각각의 입경은 5-10mm, 2-5mm, 1-2mm, 2-5mm이고, 탁도를 유발하는 물질로는 입경이 $20{\mu}m$인 황토를 사용하였다. 단일매질 구성을 통해 각각의 여재 종류에 따른 탁도 저감 효과에 대해서 분석하였고, 세 가지의 혼합매질 구성을 통해 치환층 여재의 배치에 따른 탁도 저감 효과를 분석하였고, 각각의 구성은 중사-왕사-자갈-화산석, 화산석-중사-왕사-자갈, 중사-왕사-화산석-자갈로 하였다. 주입수는 30-50NTU를 유지하였으며 유출수의 탁도를 통해 저감 효율을 분석하였다. 분석된 결과를 통해 개착식 하상여과 방식의 여재 구성에 대해서 탁도 저감에 효율을 극대화할 수 있을 것으로 보여진다.

  • PDF

강원도 지역에서의 상록지피식물의 조경적 이용에 관한 기초적 연구(I) -증식, 내음성, 내한성, 생육량의 차이에 관하여 (Fundamental Studies on the Landscape Use of Evergreen Ground Cover Plants in KANG WON Area -Propagation, Shade Tolerance, Cold Resistance, and Growth Rate)

  • 홍종운;이기철;허범람;원경렬;임병춘
    • 아시안잔디학회지
    • /
    • 제7권1호
    • /
    • pp.19-30
    • /
    • 1993
  • Experiments were conducted to investigate propagation, shade tolerance, cold resistance and growth rate of evergreen ground cover plants ; Vinca minor K , Ajuga reptans L., Ophiopogon japonicus ker. f nanus hort , and Hedera helix.. The results were as follows : 1.It is convenient to use the growing case for rice seed to grow and transplant Vinca minor seed-ling. The most proper density of transplanting Vinea was 180 plants per 1m$^2$. At the end of growing season, the coverage came up to 90% The rooting ability of Hedera helix was best to cut from April to May (temperature 15~23˚C). The seedling length of Parthenocissus quinguefohlia were irregular and ranged from 5 cm of 200cm. 2. Ajuga reptans L., Ophiopogon j. and Vinca minor L. grew better under 50% light intensity than full sunlight. Particularly, under full sunlight and aestival high temperature, there were a few withering plants in Ajuga reptans L. , and V Vilica minor L. 3. Of Vinca minor K., Ajuga reptans L. , Ophiopogon japonicus ker. f. nanus hort. and Hedera helix. acclimatized in open field, where temperature was from -7~8˚C. There were few plants had damage in low temperature incubator to -16˚C after field acclimatization. 4.Tendrils of Parthenocissus quinguefolia strongly clung to the wire netting stone fence but intruded into the gap and cranny of the precast concrete fence and so clung to, so that it needed to install the bending net on the precast concrete fence.

  • PDF

개착식 전력구의 내진성능 평가 및 내진 안전성 검증 (Study on Seismic Performance Evaluation and Verification of Seismic Safety for Power Cable Tunnels)

  • 황경민;전낙현;정길영;박경성
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.439-445
    • /
    • 2020
  • 본 논문에서는 내진설계가 고려되어 있지 않은 전력구를 포함한 기설 개착식 전력구 100개소를 대상으로, 정부의 요구수준(내진 특등급, 0.22 g)을 만족하는지 확인하기 위하여 내진성능 평가를 수행하였다. 내진성능 평가 결과, 대상 전력구들은 대부분 0.3-1 g의 내진성능을 보유하고 있는 것으로 나타나, 내진 특등급 수준을 만족하였으며 내진안전성을 확보하고 있는 것으로 나타났다. 한편 응답변위법에 의한 전력구의 내진성능 평가 방법 및 결과에 대한 타당성을 확인하고, 전력구의 내진 안전성을 검증하기 위한 지진응답 해석 및 구조실험을 수행하였다. 그 결과 0.22 g 수준의 지진 하에서 응답변위법에 의한 상대변위는 지진응답 해석 결과보다 보수적이었으며, 실규모 구조실험에 의한 하중-변위 곡선 및 응답수정계수 산정 결과를 통해 전력구의 내진 안전성을 확인할 수 있었다.