Browse > Article
http://dx.doi.org/10.5207/JIEIE.2003.17.1.017

Development of High Efficiency Self Diagnosis Type Neon Transformer using Groin Direction of Non-Oriented Silicon Steel Strip  

변재영 (승일전자 기술연구소)
김윤호 (중앙대공대 전기공학과)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.17, no.1, 2003 , pp. 17-24 More about this Journal
Abstract
In this paper, a high efficiency leakage transformer for neon tube is developed to improve its power factor, to reduce its core loss and weight by using a technique of shape optimization and grain direction of non-oriented silicon steel strip. A protection circuit is designed for all types of neon transformer loaded with one or more neon tubes. Whenever the neon tube fails to be started up or comes to the life end, or encounters faults with open-circuits at the output terminals of the neon transformer, the electronic type protection circuit will be initiated to avoid more critical hazards. These neon transformers need a electronic type protection circuit to prevent from current stresses on circuit components by neon tube fail. The input of the transformer is automatically cut on when the abnormal condition occurs, preventing waste of no-load power.
Keywords
Neon tube; Leakage transformer; Non-oriented Silion steel strip; Shape optimization; Grain direction;
Citations & Related Records
연도 인용수 순위
  • Reference
1 A. L. J. Janssen, L. H. te Paske, W. A. van der Linden, R. P. R. Smeets “Magnetic Saturation at Short-Circuit Tests on Power Transformers” IEEE, V 3, pp.1830-1835, 2001.   DOI
2 Shikaze Y, Imori M., Fuke H, Matsumoto H.,,Taniguchi T, “A high-voltage power supply operating under a magnetic field” IEEE V.48 N.3, 535-540, 2000.   DOI   ScienceOn
3 Waeckerle T, Rouve LL, Talowski C, “Study of Anisotropic B-H Models for Transformer Cores”, IEEE Transactions on Magnetics, V.31 N.6 , PP.3991-3993 1995.   DOI   ScienceOn
4 Krell C, Baumgartinger N, “Stress effects on the multidirectional magnetic behaviour of grain-oriented silicon iron sheets”, Journal of Magnetism & Magnetic Materials. V 215-216 , pp63-65 2000.   DOI   ScienceOn
5 Moses AJ, “Comparison of transformer Loss Prediction from coumputed and Measured flux density distribution”, IEEE Transactions on Magnetics, V.34 N.4 PP,1186-1188, 1998.   DOI   ScienceOn