• Title/Summary/Keyword: Open channel flow

Search Result 287, Processing Time 0.025 seconds

Flow structures around a three-dimensional rectangular body with ground effect

  • Gurlek, Cahit;Sahin, Besir;Ozalp, Coskun;Akilli, Huseyin
    • Wind and Structures
    • /
    • v.11 no.5
    • /
    • pp.345-359
    • /
    • 2008
  • An experimental investigation of the flow over the rectangular body located in close proximity to a ground board was reported using the particle image velocimetry (PIV) technique. The present experiments were conducted in a closed-loop open surface water channel with the Reynolds number, $Re_H=1.2{\times}10^4$ based on the model height. In addition to the PIV measurements, flow visualization studies were also carried out. The PIV technique provided instantaneous and time-averaged velocity vectors map, vorticity contours, streamline topology and turbulent quantities at various locations in the near wake. In the vertical symmetry plane, the upperbody flow is separated from the sharp top leading edge of the model and formed a large reverse flow region on the upper surface of the model. The flow structure downstream of the model has asymmetric double vortices. In the horizontal symmetry plane, identical separated flow regions occur on both vertical side walls and a pair of primary recirculatory bubbles dominates the wake region.

Study on the performance analysis and the optimization of regenerative pump (재생펌프의 성능해석 및 최적화에 관한 연구)

  • Lee, Chan;Sung, Hyung-Jin;Kwon, Jang-Hyuk;Chung, Myung-Kyoon
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.661-667
    • /
    • 1991
  • A performance of a regenerative pump has been analyzed using various pressure loss correlations. The predicted head and efficiency agree favorably with experimental data, which confirms the validity of the present analysis. In addition, performance improvement is made through the optimization of the open channel geometry configuration and the capacity of the regenerative pump. The optimized pump has better efficiency, higher head and larger flow coefficient. Moreover, its operation range is wider than that of the conventional unit.

Evaluation of the mechanical pipe flowmeter at low hydraulic head (저수두에서 기계식 관수로 유량계의 적용성 평가)

  • Sohn, Seung-Ho;Chung, Sang-Ok
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.53-56
    • /
    • 2002
  • This study presents an evaluation of the mechanical pipe flowmeter at low hydraulic heads. Three flowmeters each of 75mm and 25mm diameter were used. The Flowmeter was tested with experimental open channel apparatus. Relationship between flowmeter values and bucket values was good. The 75mm diameter flow meter showed small relative errors with hydraulic heads above 9cm. The 25mm diameter flow meter showed small relative errors with hydraulic heads above 2cm. The Irrigation flow measurement using the mechanical pipe flowmeter of 75mm diameter in paddy fields needs hydraulic head above 9cm, which is easy to get in tertiary canals.

  • PDF

ANALYSIS OF VELOCITY STRUCTURE OF WALL JET ORIGINATING FROM CIRCULAR ORIFICES IN SHALLOW WATER

  • Kim, Dae-Geun;Seo, Il-Won
    • Water Engineering Research
    • /
    • v.3 no.4
    • /
    • pp.235-245
    • /
    • 2002
  • In this study, breakwater model which has several outlet pipes to discharge water is settled in the experimental open channel and mean velocity distributions of multi wall jet are measured. The length of flow of flow establishment of wall jet is shorter than that of free jet and decay rate of jet centerline longitudinal velocity along x is linear in 0.3 $\leq$ x/$\l_q$ $\leq$ 17. The rate of vertical width and lateral width spreading of multi wall jet is respectively 0.0753, 0.157~0.190.

  • PDF

The Standard of Sump Design in Pump Station (펌프장내 흡수정 설계 기준)

  • Roh, H.W.;Oh, O.S.;Lee, Y.H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.589-592
    • /
    • 2005
  • In general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank, is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, may introduce air into pump, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. Unfortunately in order to design the sump station, the reasonable code or the standards weren't presented yet in Korea. Thus, some researchers had often referred the HI code, JSME code or CEN code to design the sump station. This study aims to prescribe the standard of sump design which were matched well the Korean pump station. Thus, the HI code and TSJ code would be interpreted fully to Korean language, the part of interpreted clauses of the western codes would be selected to compose the standard.

  • PDF

Analysis of Generating Mechanism of Secondary Currents in Open-Channel Flows by Reynolds Stress Model (레이놀즈응력모형을 이용한 개수로 흐름에서의 이차흐름 생성 메커니즘 분석)

  • Choi, Sung-Uk;Kang, Hyeongsik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.381-385
    • /
    • 2004
  • 본 인구에서는 레이놀즈응력모형을 이용하여 직사각형 개수로 흐름을 수치모의 하고 이차흐름의 생성 메커니즘을 제시하였다. 수치모의 결과 자유수면과 측벽의 접합부 근처에서 inner secondary flow가 발생하였다. 이는 최근 Grega 등(1995)과 Hsu 등(2000)에 의해 밝혀진 새로운 이차흐름이다. 또한 측벽에서의 전단력 분포를 계산한 결과 inner secondary flow에 의하여 수면 근처에서의 전단력 값이 증가하는 것으로 나타났다. 계산된 결과를 이용하여 와도 방정식에서 각 항의 크기를 비교하여 이차 흐름의 생성 메커니즘을 살펴보았다. 그 결과 벽 및 측벽 경계 부근에서는 난류의 비등방성에 의한 와도 생성항에 의해 이차 흐름이 생성되고, 경계와 멀리 떨어진 영역에서는 레이놀즈응력에 의한 와도 생성항이 이차흐름을 생성시키는데 중요한 역할을 하는 것으로 나타났다.

  • PDF

Evaluation of Discharge Coefficients for Sharp Crested Side Weir in Wide Channel (폭이 넓은 개수로에서의 예연횡월류위어 유량계수 산정)

  • Lee, Dong Sop;Kim, Chang Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5B
    • /
    • pp.449-458
    • /
    • 2008
  • This study is investigating experimentally the effect of upstream Froude number, weir height, weir length, and main channel width on the discharge coefficient of rectangular sharp crested side-weirs under subcritical flow conditions in a relatively wide rectangular open channel based on the De Marchi discharge coefficient $C_M$. The effects of four main influential parameters found by dimensional analysis, $Fr_1$, $h/y_1$, L/B, and $L/y_1$ are examined by the flume tests. New estimated equations for the discharge coefficients of sharp-crested side-weir are suggested based on the experimental results. The effect of $Fr_1$ for the discharge coefficient of sharp crested side weir is decreased in wide open channel and the relative importance of other influential parameters like $h/y_1$, L/B, and $L/y_1$ are increased. Also, the experimental results are compared with the results of other studies to extend the applicability of pre-suggested formulas for sharp-crested side-weir discharge coefficient.

PREDICTION OF FREE SURFACE FLOW ON CONTAINMENT FLOOR USING A SHALLOW WATER EQUATION SOLVER

  • Bang, Young-Seok;Lee, Gil-Soo;Huh, Byung-Gil;Oh, Deog-Yeon;Woo, Sweng-Woong
    • Nuclear Engineering and Technology
    • /
    • v.41 no.8
    • /
    • pp.1045-1052
    • /
    • 2009
  • A calculation model is developed to predict the transient free surface flow on the containment floor following a loss-of-coolant accident (LOCA) of pressurized water reactors (PWR) for the use of debris transport evaluation. The model solves the two-dimensional Shallow Water Equation (SWE) using a finite volume method (FVM) with unstructured triangular meshes. The numerical scheme is based on a fully explicit predictor-corrector method to achieve a fast-running capability and numerical accuracy. The Harten-Lax-van Leer (HLL) scheme is used to reserve a shock-capturing capability in determining the convective flux term at the cell interface where the dry-to-wet changing proceeds. An experiment simulating a sudden break of a water reservoir with L-shape open channel is calculated for validation of the present model. It is shown that the present model agrees well with the experiment data, thus it can be justified for the free surface flow with accuracy. From the calculation of flow field over the simplified containment floor of APR1400, the important phenomena of free surface flow including propagations and interactions of waves generated by local water level distribution and reflection with a solid wall are found and the transient flow rates entering the Holdup Volume Tank (HVT) are obtained within a practical computational resource.

Numerical anslysis of Transcritical Flow in Open Channels Using High-Resolution scheme I. : Model Development (고정확도 수치기법을 이용한 하천 천이류 해석 I. : 모형 개발)

  • Kim, Won;Han, Kun-Yeun
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.1
    • /
    • pp.45-55
    • /
    • 2001
  • Transcritical flow is a term intended to denote the existence of both supercritical and subcritical flows within a computational domain. The major problems that need to be addressed while modeling transcritical flows include handling the differing features of signal propagation in subcritical and supercritical flow regions and maintaining conservation. The present study proposes the implicit ENO method as a high-resolution scheme for transcritical flow. This implicit ENO scheme is based on the ENO method, a new class of uniformly high-order-accurate essentially non-oscillatory implicit scheme, which has the advantage of unconditional stability. The implicit ENO scheme has not been used for the transcritical flow in open channel until now. As a result of application to the hypothetical dam-break flow, the implicit ENO scheme was ploved to produce accurate results with good robustness even though in the case of verb strong shock wave.

  • PDF

Evaluation of the applicability of a buoyancy-modified turbulence model for free surface flow analysis based on the VOF method (VOF 기반 자유수면 흐름 해석을 위한 부력 수정 난류 모형의 적용성 평가)

  • Lee, Du Hana
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.8
    • /
    • pp.493-507
    • /
    • 2024
  • RANS-based CFD analysis is widely applied in various engineering fields, including practical hydraulic engineering, due to its high computational efficiency. However, problems of non-physical behavior in the analysis of two phase flow, such as free surfaces, have long been raised. The two-equation turbulence models used in general RANS-based analysis were developed for single phase flow and simulate unrealistically high turbulence energy at the interface where there are abrupt changes in fluid density. To solve this issue, one of the methods recently developed is the buoyancy-modified turbulence model, which has been partially validated in coastal engineering, but has not been applied to open channel flows. In this study, the applicability of the buoyancy-modified turbulence model is evaluated using the VOF method in the open-source program OpenFoam. The results of the uniform flow showed that both the buoyancy-modified k-𝜖 model and the buoyancy-modified k-ω SST model effectively simulated the reduction of turbulence energy near the free surface. Specifically, the buoyancy-modified k-ω SST model accurately simulated the vertical velocity distribution. Additionally, the model is applied to dam-break flows to examine cases with significant surface variation and cavity formation. The simulation results show that the buoyancy-modified turbulence models produce varying results depending on the VOF method and shows non-physical behavior different from experimental results. While the buoyancy-modified turbulence model is applicable in cases with stable surface shapes, it still has limitations in general application when there are rapid changes in the free surface. It is concluded that appropriate adjustments to the turbulence model are necessary for flows with rapid surface changes or cavity formation.