• Title/Summary/Keyword: One-to-one Resonance

Search Result 1,418, Processing Time 0.024 seconds

Electrochemical Reduction of Triphenylphosphine Phenylimide (Triphenylphosphine Phenylimide의 전기화학적인 환원)

  • Pak Chong Min;Wilson M. Gulick, Jr.
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.5
    • /
    • pp.341-353
    • /
    • 1974
  • The electrochemical reduction of triphenylphosphine penylimide in nonaqueous media has been examined by polarography, cyclic voltammetry, controlled-potential coulometry and electron spin resonance spectroscopy. The reduction of triphenylphosphine phenylimide proceeds by a one-electron transfer to form anion radical which undergoes both protonation and a second one-electron reduction followed by cleavage of the phosphorus-nitrogen double bond. Aniline is a major product. The cleavage of a phosphorus-phenyl bond was also observed after reduction of triphenylphosphine oxide which is one of the major products of the chemical reaction which follow the primary process.

  • PDF

A Study on the Wireless Power Transfer System using Magnetic Resonance at the 1[MHz] Frequency Band (1[MHz] 대역의 자계 공명을 이용한 무선 전력 전송 장치에 관한 연구)

  • Park, Jeong-Heum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.75-81
    • /
    • 2012
  • In this paper, the wireless power transfer system using the magnetic resonance was designed, analyzed by circuit analysis methode and the calculated transfer function was compared with the measured one. The self-resonant coil was made up of the commonly used capacitor which had the lumped capacitance and it enabled the stable magnetic resonance not to be affected by the circumstance. The transmission efficiency of this system was 70[%] at the 15[cm] between the transmission and receiving coil and the measured transfer function was similar to the calculated one, which means the circuit analysis methode is valid in this system. When the intermediate coils were added between the transmission and receiving coil, the transmission efficiency was increased, which produced the increase of transfer distance. In the case of the five intermediate coils adding, the 35[%] transmission efficiency was achived at the 90[cm] distance.

Global Bifurcations and Chaos Via Breaking of KAM Tori of an Harmonically Excited Imperfect Circular Plate

  • Samoylenko, S.B.;Lee, W.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.419-422
    • /
    • 2005
  • Global bifurcations and chaos in modal interactions of an imperfect circular plate with one-to-one internal resonance are investigated. The case of primary resonance, in which an excitation frequency is near natural frequencies, is considered. The damping force is not included in the analysis. The renormalization-group technique for KAM tori is used to obtain the criteria for large-scale stochasticity in the system.

  • PDF

Global Bifurcations and Chaos in an Harmonically Excited and Undamped Circular Plate

  • Samoylenko, Sergey B.;Lee, Won-Kyoung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.140-144
    • /
    • 2004
  • Global bifurcations and chaos in modal interactions of an imperfect circular plate with one-to-one internal resonance are investigated. The case of primary resonance, in which an excitation frequency is near natural frequencies, is considered. The damping force is not included in the analysis. The Melnikov's method for heteroclinic orbits of the autonomous system was used to obtain the criteria for chaotic motion.

  • PDF

Paradoxical Response of Giant Left Atrial Appendage Aneurysm after Catheter Ablation of Atrial Fibrillation

  • Chung, Jee Won;Shim, Jaemin;Shim, Wan Joo;Kim, Young-Hoon;Hwang, Sung Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.132-135
    • /
    • 2016
  • We report the case of a 43-year-old male with both giant left atrial appendage (LAA) aneurysm and drug-refractory atrial fibrillation (AF). The patient was treated with percutaneous electrical isolation of cardiac arrhythmogenic substrate, and has been free of AF symptom over one year. Although the surgical resection of giant LAA aneurysm is mostly used to prevent systemic thromboembolism, we have performed follow-up of the giant LAA aneurysm using cardiac magnetic resonance (CMR) imaging and transesophageal echocardiography (TEE) after the successful catheter ablation of refractory AF. At one-year follow-up CMR, the giant LAA aneurysm showed remarkable enlargement as well as decreased contractility. Additionally, one-year follow-up TEE showed spontaneous echo contrast as an indicator of blood stasis in the giant LAA aneurysm. Those findings of giant LAA aneurysm suggest that the risk of thromboembolism may be high despite termination of AF.

Geometrical Construction of the S Matrix and Multichannel Quantum Defect Theory for the two Open and One Closed Channel System

  • Lee, Chun-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.7
    • /
    • pp.971-984
    • /
    • 2002
  • The multichannel quantum defect theory (MQDT) is reformulated into the form of the configuration mixing (CM) method using the geometrical construction of the S matrix developed for the system involving two open and one closed channels. The reformulation is done by the phase renormalization method of Giusti-Suzor and Fano. The rather unconventional short-range reactance matrix K whose diagonal elements are not zero is obtained though the Lu-Fano plot becomes symmetrical. The reformulation of MQDT yields the partial cross section formulas analogous to Fano's resonance formula, which has not easily been available in other's work.

Phase Shifted Magnetic Resonance Wireless Power Transfer System with Two Transmit Coils (두 개의 송신코일을 갖는 위상 천이 자기 공진 무선 전력 전송 시스템)

  • Jung, Jae-Yup;Yi, Kang-Hyun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.4
    • /
    • pp.290-293
    • /
    • 2018
  • This paper proposes a new magnetic resonant wireless power transfer system. Two transmitters are arranged to secure a range wider than the existing one-to-one resonance, thereby enhancing the practicality of the system. Two identical transmission units are arranged to strengthen the magnetic field and to subsequently increase the magnitude and distance of the power transmitted to the reception unit. A constant power can be maintained in a wide range through the phase control of different output powers according to the positions of the transmitting and receiving coils. A constant power can also be obtained by transmitting to the receiver. The experiment results show that the proposed method outperforms the conventional method.

3-D Vibration Characteristics of Radial Tire for Passenger Car under Fixed Axle (축으로 고정된 승용차용 레디얼 타이어의 3차원 진동특성)

  • 김용우;남진영
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.3
    • /
    • pp.228-235
    • /
    • 2002
  • Two kinds of experimental modal analyses have been performed on a radial tire for passenger car under fixed axle. One is the modal analysis to obtain three-dimensional modes of tire using accelerometers and the other is the one to identify cavity resonance frequency using a pressure sensor. From the first analysis, we have obtained three-dimensional natural modes and their decomposed 3-D modes in each direction, which make it possible to grasp the features of the modes that cannot be identified in the conventional 2-D modes and to classify the vibrationall modes into symmetric, non-symmetric, and antisymmetric modes in a simple way by using the experimental results. From the second experimental analysis, the cavity resonance frequency is found. Coomparing the results of the two analyses, we have Identified the three-dimensional mode of the cavity resonance. We also haute shown that natural frequencies of structural vibration depends on inflation Pressure while the cavity resonance does not.

Non-linear Vibration of Rectangular Plates (직사각형 평판의 비선형 진동)

  • Chang, Seo-Il;Lee, Jang-Moo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.35-39
    • /
    • 1994
  • One of the important characteristics of the response of nonlinear systems is the existence of subharmonic resonances. When some conditions in parameter space are satisfied. It is possible even in the presence of damping for a periodically excited nonlinear system to possess a response which is the combination of a contribution at the excitation frequency and a component at the system natural frequency. The system natural frequency being a submultiple of the excitation frequency implies that the resulting response is a subharmonic oscillation. In general, there also co-exists, for the system, a response at the excitation frequency, and initial conditions determine which of the steady-state responses is achieved in an experiment or a numerical simulation. In single-degree-of-freedom systems with harmonic excitation, depending on the type of the nonlinearity, e.g., cubic or quadratic the frequency of subharmonic response is respectively, one-third or one-half of that of the excitation frequency. Although subharmonic resonance is one of the principal characteristics of a nonlinear system the subharmonic responses of structures in the presence of internal resonances have been studied very rarely. In this work, we consider subharmonic responses in the two-mode approximation of the plate equations. It is assumed that the two modes are in one-to-one internal resonance. Constant and periodic steady-state solutions of the averaged equations are studied. Finally, the results of direct time integration of the original equations of motion are presented and compared with those obtained from the averaged equations.

  • PDF

On the Minimization of Room Resonance by Room Tuning (룸 튜닝에 의한 실내 공진의 최소화)

  • Kang, Seong-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.8
    • /
    • pp.507-513
    • /
    • 2012
  • The room modes were showed as the peaks and dips on the low frequency response of the loudspeaker, and were one of the biggest obstacles to reproduce the sound. In order to reduce the occurrence of resonance, equalizing is performed at one position, and the frequency response to be equalized is valid only at that position. Performing the equalization would improve the flatness of the frequency response a little, but it cannot eliminate the ringing. Another method is that it is located the speaker at the specific position where the room resonances were not frequently happened. However, there may be the practical limitation that you may not be able to install the speaker at the position to be wanted. One of the practical solutions to decrease the production of resonance in room is the use of bass trap. In this paper, the practical limit for the room tuning using an equalizer and the room optimization will be discussed. The use of bass traps to solve the resonance problem that is always happened in the room is also proposed.