• Title/Summary/Keyword: On-line monitoring device

Search Result 75, Processing Time 0.024 seconds

Measurement of Gas Concentration and flow Rate Using Hot Wire (열선을 이용한 혼합기체의 농도와 유량의 측정)

  • Kim, Young-Han;Park, Jong-Jueng
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.5
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.

An Development of Leakage Current Sensing Module of the System on Chip Type Under Consideration of Electromagnetic Interface in Power Trunk Line (전력간선에서의 전자파 장애를 고려한 원칩형 누설전류 원격 검출단말기의 개발)

  • Kim, Dong-Wan;Park, Ji-Ho;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.377-384
    • /
    • 2009
  • In this paper, leakage current sensing module of SoC(System on Chip)type and real time monitoring system under consideration of electromagnetic interface in power trunk line are developed. The first, leakage current sensing module of SoC type under consideration of electromagnetic interface is developed, and the developed sensing module of SoC type is composed of leakage sensing part, power supply part, interface part, communication part, AD(Alternating current to Direct current)convert part and amplification part. And also the electromagnetic compatibility is evaluated by conduction and radiation of EMI(Electromagnetic Interference) for developed sensing module. The developed system can have confidence, stability and do energy saving under mixed electric circumstance of the low voltage communication device and high voltage equipment. The second, the real time remote monitoring system is developed using designed wire and wireless communication module with leakage current sensing module of SoC type. The developed real time remote monitoring system can monitor sensing state, occurrence state of leakage current and alarm for each step etc.. And the device configuration, PCB layout for leakage current sensing module of system on chip type and the experiment configuration in consideration of EMI are presented. Also the measurement results of conduction and radiation for EMI are presented.

Smart Home Healthcare Device based on Ubiquitous Communication

  • Kim, Keun-Young;Cha, Joo-Hun;Park, Mig-Non
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2235-2239
    • /
    • 2003
  • The aim of this research is to study and develop enabling technologies for home healthcare device with ubiquitous network. The motivation of this paper is to enable healthcare in home, to development the device for smart home health care. To achieve the aim, we must develop the prototype platform based on home gateways, distributed context user interface based on UPnP and support for information sharing with high speed power line communication and mobile infra-structures. And IPv6 is the base technology of this platform. In this paper, we concern that physical health, mental health and medical emergencies is all of home healthcare. With the smart device, we evaluate the connectivity, automatic information extraction and private data exchange and event driven message. The result of this paper is demonstration of smart device for ubiquitous communication in a healthcare application such as patient monitoring device and several information services. In conclusion, home healthcare will support more healthy and easy living for a human.

  • PDF

IRRADIATION DEVICE FOR IRRADIATION TESTING OF COATED PARTICLE FUEL AT HANARO

  • Kim, Bong Goo;Park, Sung Jae;Hong, Sung Taek;Lee, Byung Chul;Jeong, Kyung-Chai;Kim, Yeon-Ku;Kim, Woong Ki;Lee, Young Woo;Cho, Moon Sung;Kim, Yong Wan
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.941-950
    • /
    • 2013
  • The Korean Nuclear-Hydrogen Technology Development (NHTD) Plan will be performing irradiation testing of coated particle fuel at HANARO to support the development of VHTR in Korea. This testing will be carried out to demonstrate and qualify TRISO-coated particle fuel for use in VHTR. The testing will be irradiated in an inert gas atmosphere without on-line temperature monitoring and control combined with on-line fission product monitoring of the sweep gas. The irradiation device contains two test rods, one has nine fuel compacts and the other five compacts and eight graphite specimens. Each compact contains about 260 TRISO-coated particles. The irradiation device is being loaded and irradiated into the OR5 hole of the in HANARO core from August 2013. The device will be operated for about 150 effective full-power days at a peak temperature of about $1030^{\circ}C$ in BOC (Beginning of Cycle) during irradiation testing. After a peak burn-up of about 4 atomic percentage and a peak fast neutron fluence of about $1.7{\times}10^{21}\;n/cm^2$, PIE (Post-Irradiation Examination) of the irradiated coated particle fuel will be performed at IMEF (Irradiated Material Examination Facility). This paper reviews the design of test rod and irradiation device for coated particle fuel, and discusses the technical results for irradiation testing at HANARO.

Implementation of Lamp Monitoring System(LMS) for Ship Based on PLM (PLM 통신기반 선박용 LMS 구현)

  • Lim, Hyun-Jung;Yang, Hyun-Suk;Kim, Kun-Woo;Baek, Young-Jin;Kim, Yoon-Sik;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.182-189
    • /
    • 2007
  • This paper describes the implementation of control and monitoring system of ship's lamps at local area using power line communication method, power line modem(PLM). We design modem, microprocessor interface for electric power control by frequency control and analog to digital signal conversion, lamp device. PLM communication is very economical using existing electric power line unlike RS-232, RS-485 communications. We verify and confirm by experimental work that control and monitor lamp system for ship by an PLM communication.

Multipoint Process Monitoring System Based on a Near Infrared Ray(NIR) Acousto-Optic Tunable Filter(AOTF)

  • You, Jang-Woo;Kim, Daesuk;Kim, Soohyun;Kong, Hong-Jin;Lee, Yunwoo;Kwak, Yoon-Keun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.105.4-105
    • /
    • 2001
  • This paper describes a newly designed multipoint process monitoring system based on a NIR acousto-optic tunable filter. The NIR multipoint process monitoring system consists of a NIR AOTF device for wavelength selection, an InGaAs array sensor, and a specially designed iin-line type of optical fiber probe. Unlike a FTS(Fourier Transform Spectrometry) or grating based monitoring system, an AOTF has no moving parts, and it can be rapidly tuned to any wavelength in its operating range within microseconds. Thus, the AOTF is advantageous in terms of faster spectral imaging capability and rigidity required for industrial monitoring environment. In the current feasibility evaluation, an enhanced optical fiber probe with 3 monitoring points was used. However, ...

  • PDF

A Boundary-Scan Based On-Line Circuit Performance Monitoring Scheme (경계 스캔 기반 온-라인 회로 성능 모니터링 기법)

  • Park, Jeongseok;Kang, Taegeun;Yi, Hyunbean
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.51-58
    • /
    • 2016
  • As semiconductor technology has developed, device performance has been improved. However, since device structures became smaller, circuit aging due to operational and environmental conditions can be accelerated. Circuit aging causes a performance degradation and eventually a system error. In reliable systems, a failure due to aging might cause a great disaster. Therefore, these systems need a performance degradation prediction function so that they can take action in advance before a failure occurs. This paper presents an on-line circuit performance degradation monitoring scheme for predicting a failure by detecting performance degradation during circuit normal operation. In our proposed scheme, IEEE 1149.1 output boundary scan cells and TAP controller are reused. The experimental result shows that the proposed architecture can monitor the performance degradation during normal operation without stopping the circuit.

Simulation Studies on Monitoring System for Interconnection of Distibuted Generation to Power Grid (분산전원 계통 연계 상황 모니터링을 위한 시뮬레이션 연구)

  • Oh, Sung-Nam;Han, Chul-Wan;Yoon, Ki-Don;Son, Young-Ik;Kim, Kab-Il
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.96-98
    • /
    • 2005
  • This paper describes a monitoring system that monitors power quality and undesirable accidents when distributed generations are connected to the power grid. Prior to develop and operate a physical monitoring system, we constitute a simulation device to simulate the monitoring processes for the situations. The simulation system consists of the server and the client that connected by communication line. This system has various functions to monitor the power quality and the connection situation. Those functions are generation, transmission, acquisition and analysis of the simulated power data. This research seems very important to get the reliable and intelligent connection algorithm through the result of simulated monitoring system. Also hereafter, as this system uses the remote monitoring system through network and constitute the data base(DB), it will play an important role in building the automation of power system efficiently and systematically.

  • PDF

Implementation of UPnP Middleware and Device Control using Power Line Communication for Home Network (홈네트워크를 위한 전력선 통신을 이용한 장치 제어 및 UPnP 미들웨어 구현)

  • Kim, Gwan-Hyung;Jean, Jae-Hwan;Kang, Sung-In;Oh, Am-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.12
    • /
    • pp.25-32
    • /
    • 2009
  • This paper proposes the construction of intelligent home network system using Power Line Communication(PLC) technique, which allows for UPnP bridge remote control and monitoring based on TCP/IP. Also, the communication for control module inside intelligent home network systems is designed with Simple Control Protocol (SCP) in which each device is connected to be controlled independently. When new UPnP device is additionally installed in intelligent home network systems, it is monitored through UPnP bridges based on its registered UPnP device information. The device control based on PLC and implementation of each UPnP device are effectively managed by using TCP/IP remote control and it's provided fundamental functions to monitor various device information in the home network.

High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility

  • Cheong, Yong-Moo;Kim, Kyung-Mo;Kim, Dong-Jin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1463-1471
    • /
    • 2017
  • In order to monitor the pipe thinning caused by flow-accelerated corrosion (FAC) that occurs in coolant piping systems, a shear horizontal ultrasonic pitch-catch waveguide technique was developed for accurate pipe wall thickness monitoring. A clamping device for dry coupling contact between the end of the waveguide and pipe surface was designed and fabricated. A computer program for multi-channel on-line monitoring of the pipe thickness at high temperature was also developed. Both a four-channel buffer rod pulse-echo type and a shear horizontal ultrasonic waveguide type for high-temperature thickness monitoring system were successfully installed to the test section of the FAC proof test facility. The overall measurement error can be estimated as ${\pm}10{\mu}m$ during a cycle from room temperature to $200^{\circ}C$.