• 제목/요약/키워드: On-line diagnosis

검색결과 548건 처리시간 0.021초

수력발전기 On-line 부분방전 측정 시스템을 이용한 절연상태 진단의 신뢰성 향상 (Reliability Improvement of Insulation Diagnosis Using the Hydro-Generator On-Line Partial Discharge Monitoring System)

  • 옥연호;이은웅;임재일;박지군;곽원구;이재흥;신재필;신병철
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.469-475
    • /
    • 2009
  • Accident dangerousness of domestic hydro power generators which are operated in Korea is on the increase because of use at the long term. On this, the Off-line diagnosis techniques developed to the On-line by continued domestic technical development since 2000. Especially, On-line insulation diagnosis of domestic hydro power generator is possible by localization of partial electric discharge sensor and On-line insulation diagnosis system. This paper shows the diagnosis result that is applied localized Ceramic Coupler and PDMS-HG(Partial Discharge Monitoring System for Hydro Generator) at four Chung-ju hydro Generator used for 25 years. Particularly, the confidence of insulation diagnosis is improved by using high frequency filter and sampling the partial discharge signals which occur in site. For reviewing the confidence of On-Line insulation diagnosis system, we measured the outside noises and partial discharge signals during practical operation by using the partial discharge diagnosis system of the Full A/D process. And we reviewed the confidence of the On-Line insulation diagnosis system by comparing and analyzing these data.

발전기 운전중 종합 진단시스템 개발 (Development of On line Diagnosis System for Generator)

  • 이영준;공태식;김희동;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.975-977
    • /
    • 2005
  • The generator on-line diagnosis system has been developed. This system monitor the insulation condition of stator winding by on-line measurements of partial discharge and the shorted-turn condition of rotor winding by on-line measurements of slot leakage flux. Sensor, such as SSC(Stator Slot Coupler) and flux probe are used for generator on-line diagnosis.

  • PDF

An Integrated On-Line Diagnostic System for the NORS Process of Maiden Reactor Project: The Design Concept and Lessons Learned

  • Kim, Inn-Seock
    • Nuclear Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.261-273
    • /
    • 2000
  • During an extensive review made as part of the Integrated Diagnosis System project of the Maiden Reactor Project, MOAS (Maryland Operator Advisory System) was identified as one of the most thorough systems developed thus far. MOAS is an integrated on-line diagnosis system that encompasses diverse functional aspects that are required for an effective process disturbance management: (1) intelligent process monitoring and alarming, (2) on-line sensor data validation and sensor failure diagnosis, (3) on-line hardware (besides sensors) failure diagnosis, and (4) real-time corrective measure synthesis. The MOAS methodology was used at the Maiden Man-Machine Laboratory HAMMLAB of the OECD Maiden Reactor Project. The performance of MOAS, developed in G2 real-time expert system shell for the high-pressure preheaters of the NORS process in the HAMMLAB, was tested against a variety of transient scenarios, including failures of the control valves and sensors, and tube leakage of the preheaters. These tests showed that MOAS successfully carried out its intended functions, i.e., quickly recognizing an occurring disturbance, correctly diagnosing its cause, and presenting advice on its control to the operator. The lessons learned and insights gained during the implementation and performance tests also are discussed.

  • PDF

회전기 고정자 권선에서의 운전 중 절연열화 진단기법 (On-Line Insulation Diagnosis Techniques for Stator Winding of Rotating Machines)

  • 윤대희;황돈하;신병철;김용주;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.89-93
    • /
    • 2000
  • Recently many research activities on the diagnosis of stator winding insulation of large rotating machines have been reported. Capacitive couplers are widely used as sensors for on-line partial discharge (PD) measurement of high voltage rotating machines. This paper presents laboratory test to compare Stator Slot Coupler (SSC), Resistance Temperature Detector (RTD), 80 [pF] coupler and 500 [pF] coupler for on-line PD measurement of rotating machines. And a novel on-line monitoring system for an insulation diagnosis is proposed.

  • PDF

계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가 (Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent)

  • 조한구;한동희;이운용;임기조;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF

전력용 변압기 온라인 유중가스 진단기준치 및 알고리즘에 관한 연구 (Study on the Criterion and Algorithm for On-line Dissolved Gas of a Power Transformer)

  • 권동진;곽주식;곽희로;김재철;진상범
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.206-212
    • /
    • 2005
  • In this paper, criterion and algorithm for on-line dissolved gas of a Power transformer are studied. For the initial diagnosis of a power transformer, the on-line dissolved gas analysis is one of the most important and acceptable item to preventively diagnose a power transformer. But the criterion and algorithm of this item are not established yet in korea. In this paper, criterion and alarm level of the on-line dissolved gas analysis are based on the analysis of on-line data of operating transformers, Korea industrial standard and operation manual for a power transformer as well as accumulated data of the preventive diagnosis systems which have been operated at nine substations of Korea Electric Power Co.(KEPCO) since 1997, Therefore, the criterion and alarm level proposed in this paper are to be well suitable and are adaptable for the domestic operational environments and conditions of the power transformer. Considering that the conventional diagnosis system is capable only of accumulating and monitoring data of the power transformer operation, the criteria and the algorithms make it possible to accomplish an ultimate goal of the preventive diagnosis system. It is expected, therefore, that they will have a beneficial effect on broad applications of the preventive diagnosis system and the achievement of manless substation system in the future.

On-line Diagnosis System with Learning Bayesian Networks for fsEBPR

  • Cheon, Seong-Pyo;Kim, Sung-Shin
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제7권4호
    • /
    • pp.279-284
    • /
    • 2007
  • Nowadays, due to development of automatic control devices and various sensors, one operator can freely handle several remote plants and processes. Automatic diagnosis and warning systems have been adopted in various fields, in order to prepare an operator's absence for patrolling plants. In this paper, a Bayesian networks based on-line diagnosis system is proposed for a wastewater treatment process. Especially, the suggested system is included learning structure, which can continuosly update conditional probabilities in the networks. To evaluate performance of proposed model, we made a lab-scale five-stage step-feed enhanced biological phosphorous removal process plant and applied on-line diagnosis system to this plant in the summer.

Time-Delay Neural Network를 이용한 증류탑의 on-line 고장 진단 (On-line fault diagnosis of a distillation column using time-delay neural network)

  • 이상규;박선원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.1109-1114
    • /
    • 1992
  • Modern chemical processes are becoming more complicated. The sophisticated chemical processes have needed the fault diagnosis pxpert systems that can detect and diagnose the fault diagnosis expert systems that can detect and diagnose the faults of some processes and give and advice to the operator in the event of process faults. We present the Time-Delay Neural Network(TDNN) approach for on-line fautl diagnosis. The on-line fault diagnosis system finds the exact origin of the fault of which the symptom is propagated continuously with time. The proposed method has been applied to a pilot distillation column to show the merits and applicability of the TDNN.

  • PDF

On-line Monitoring of Tribology Parameters and Fault Diagnosis for Disc Brake System

  • Yang Zhao-Jian;Kim Seock-Sam
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2003년도 학술대회지
    • /
    • pp.224-228
    • /
    • 2003
  • The basic Principles and methods of the on-line monitoring of tribology parameters (friction coefficient and wear allowance) and fault diagnosis for the hoist disc brake system were introduced, the method were based on the spring force and oil pressure of the brake system and the hoist kinematics parameters. The experiment on the monitoring and diagnosis of hoist brake system were carried out. The research results showed: the monitoring and diagnosis methods are feasible.

  • PDF

전기설비사고예방을 위한 온라인진단기술 개발의 경제성 분석 (A Study on Economic Analysis of Development of On-line Diagnosis Technique for Preventing Electrical Accidents)

  • 김한상;김광호
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.313-318
    • /
    • 2014
  • In the last couple of decades industrialization and technological development has not only increase in the scale of electrical facilities and it has become more and more complicated and diversified. Furthermore, fires in the electrical transformers, like those that have knocked out power in the country in the past years, are likely to become more common as utility systems begin to show their age. The importance of preventing electrical accidents can never be overemphasized and for this reason, supply of on-line diagnosis system combining information and communication technology(ICT) for the customer's electrical facilities has been increasing recently. The major advantage of on-line diagnosis system is that the device's potential problems could be detected early before a serious deterioration or breakdown occurs. In this paper, We estimated the benefit from the investment in the right of present value of sales, success rate of commercialization regarding R&D investment for development and commercialization of on-line diagnosis technology targeting customer electrical facilities. As a result, the net value added of 29.7 billion won and the increased profit by roughly 7.52 precent are expected.