• Title/Summary/Keyword: On-device analyzer

Search Result 133, Processing Time 0.026 seconds

Analysing of the recent trends on the constitution diagnosis and treatment device patents (체질진단 및 치료기기 최신 특허동향 분석)

  • Lee, Yu-Jung;Lee, Jeon;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.2 s.20
    • /
    • pp.91-100
    • /
    • 2007
  • In this paper, We tried to analyze the patent trend on constitution diagnosis and treatment related technologies. For this, constitution diagnosis and treatment related technologies divided into 16 sub-technology by the advisory committee. And we analyzed patents applied in Korea, Japan, U.S.A., China, and Europe. The 16 sub-technology consist of pulse analyzer, skin diagnosis, tongue analyzer, face and body detector, face analyzer, voice analyzer, intelligence ontology, meridian diagnosis, infrared thermography, electric stimulation, laser, high and low frequency, physical, magnetic, and ultrasound therapy. As a result we found that patents of constitution diagnosis and treatment in Korea has been growing steadily in both quality and quantity since 1980s. The number of patent the pulse analyzer and low frequency therapy are larger than others. But applied relevant international patents, marketability of the patent and Cites per Patent (CPP) index are shown to be very low. In conclusion, to occupy key original technologies of the Oriental medical device, we need to apply more patent of the whole related technology and international patents.

  • PDF

Fiber-optic Ccurrent Sensor Using a Long-period Fiber Grating Inscribed on a High Birefringent Fiber (복굴절이 큰 광섬유에 제작된 장주기 광섬유 격자를 이용한 광섬유 전류 센서)

  • Lee, Yong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1823-1825
    • /
    • 2007
  • Based on Faraday effect, the variation of current flowing through the conductor can be encoded as that of azimuth angle of light polarization propagating through the fiber coil wound onto the conductor. The amount of current can be obtained by measuring the variation of the light intensity transformed from that of the azimuth angle through a polarization analyzer. In this paper we propose a fiber-optic current sensor system that employs a fiber polarization analyzer as a sensor interrogation device. The fiber polarization analyzer was prepared by inscribing a long-period fiber grating on a high birefringent fiber. At the fixed wavelength of 1522.5 nm, the fabricated fiber device has the polarization extinction ratio of more than 25 dB. The measurement of large current up to 600 Arms was accomplished based on a simple fiber interrogation device and the measurement output of the sensor system showed a good linearity.

Comparison of three types of analyzers for urine protein-to-creatinine ratios in dogs

  • Ji, Sumin;Yang, Yeseul;Jeong, Yeji;Hwang, Sung-Hyun;Kim, Myung-Chul;Kim, Yongbaek
    • Journal of Veterinary Science
    • /
    • v.22 no.1
    • /
    • pp.14.1-14.11
    • /
    • 2021
  • Background: Quantitation of urine protein is important in dogs with chronic kidney disease. Various analyzers are used to measure urine protein-to-creatinine ratios (UPCR). Objectives: This study aimed to compare the UPCR obtained by three types of analyzers (automated wet chemistry analyzer, in-house dry chemistry analyzer, and dipstick reading device) and investigate whether the differences could affect clinical decision process. Methods: Urine samples were collected from 115 dogs. UPCR values were obtained using three analyzers. Bland-Altman and Passing Bablok tests were used to analyze agreement between the UPCR values. Urine samples were classified as normal or proteinuria based on the UPCR values obtained by each analyzer and concordance in the classification evaluated with Cohen's kappa coefficient. Results: Passing and Bablok regression showed that there were proportional as well as constant difference between UPCR values obtained by a dipstick reading device and those obtained by the other analyzers. The concordance in the classification of proteinuria was very high (κ = 0.82) between the automated wet chemistry analyzer and in-house dry chemistry analyzer, while the dipstick reading device showed moderate concordance with the automated wet chemistry analyzer (κ = 0.52) and in-house dry chemistry analyzer (κ = 0.53). Conclusions: Although the urine dipstick test is simple and a widely used point-of-care test, our results indicate that UPCR values obtained by the dipstick test are not appropriate for clinical use. Inter-instrumental variability may affect clinical decision process based on UPCR values and should be emphasized in veterinary practice.

Color Correction in Portable-type Urine Analyzer

  • Kim, Jae-Hyung;Park, Chang-Hee;Lee, Seung-Jin;Jeon, Gye-Rok;Kim, Gi-Ryon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.21-26
    • /
    • 2002
  • Color correction methods of chromaticity coordinates using Color Matching Function (CMF) were studied to develop a device-independent portable-type urine analyzer. The reflection spectra were measured for the degrees of 10 test items of the urine reagent strip (urine strip) to develop a portable-type urine analyzer. A computer simulation was performed to quantitatively distinguish the color reactions of the urine system, by using the spectral power distribution of Light Emitting Diode(LED), the reflection of a urine strip, and spectral sensitivity of a photodiode. To develop a device-independent system, chromaticity coordinates were modified to reduce the color deviations in the urine strip, by using the temperature compensation of LED and the color transformation by CMF. The experimental values obtained by developed urine system exhibited the accuracy above 95% for all color samples.

SOAR : Storage Reliability Analyzer (SOAR : 저장장치를 기반으로 하는 시스템의 신뢰성 분석도구 개발)

  • Kim, Young-Jin;Won, You-Jip;Kim, Ra-Kie
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.6
    • /
    • pp.248-262
    • /
    • 2008
  • As the number of large size multimedia files increases and the importance of individual's digital data grows, storage devices have been advanced to store more data into smaller spaces. In such circumstances, a physical damage in a storage device can destroy large amount of important data. Therefore, it is needed to verify the robustness of various physical faults in storage device before certain systems are used. We developed SOAR(Storage Reliability Analyzer), Storage Reliability Analyzer, to detect physical faults in diverse kinds of HDD hardware components and to recover the systems from those faults. This is a useful tool to verify robustness and reliability of a disk. SOAR uses three unique methods of creating physical damages on a disk and two unique techniques to apply the same feature on file systems. In this paper, we have performed comprehensive tests to verify the robustness and reliability of storage device with SOAR, and from the verification result we could confirm SOAR is a very efficient tool.

Implementation of Protocol Analyzer for ANSI/EIA709.1 Packet on LonWorks Network (LonWorks 네트워크 상의 ANSI/EIA709.1 패킷해석을 위한 프로토콜 분석기의 설계 및 구현)

  • Im, Il-Young;Choi, Gi-Sang;Choi, Gi-Heung
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.413-416
    • /
    • 2007
  • Use ot Intelligent devices that work on the ANSI/EIA 709.1 protocol is increasing. In this study an ANSI/EIA 709.1 protocol analyzer that can monitor and analyze the packets on LonWorks network is designed and developed. The device is based on TMS320LF2407A processor for decoding data packets, and uses XScale processor for sending data to the application program on PC. The application program has various analysis features as well as basic monitoring function. The developed device can be used for debugging purposes in development of any kind of LonWorks devices, and also it is useful in maintenance of LonWorks network or Lon Works devices.

  • PDF

Development of a Guideline for the Application of Diagnostic Devices for Menopausal Syndrome: Literature Review and Questionnaire Survey (갱년기장애 진단기기 사용에 대한 지침 개발 : 문헌검토 및 설문조사)

  • Baek, Seon-Eun;Park, Eun-Ji;Kim, Dong-Il;Lee, In-Seon;Yoo, Jeong-Eun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.30 no.3
    • /
    • pp.65-78
    • /
    • 2017
  • Objectives: This study was aimed to develop a guideline for the application of diagnostic devices for menopausal syndrome. Methods: We conducted a literature review and a questionnaire survey on diagnostic devices including Digital Infrared Thermal Imaging (DITI), pulse diagnosis device, Heart Rate Variability (HRV), body composition analyzer, Yangdorak. Results: We retrieved some clinical values for usage of devices from the articles. Especially, DITI was useful to identify the pattern of body temperature distribution. The respondents answered that they diagnosed menopausal syndrome by using body composition analyzer (62.3%), DITI (60%), HRV (60%), pulse diagnosis device (45.7%), Yangdorak (34.3%). The respondents answered that they don't use diagnostic devices when they diagnosed menopausal syndrome because of absence of device, cost, difficulty of interpretation, substitution of another diagnostic method. After experts survey, it was recommended to use DITI, HRV, body composition analyzer. There was no consensus on the use of pulse diagnosis device, Yangdorak in diagnosing menopausal syndrome. Conclusions: We developed a guideline for the application of diagnostic devices for menopausal syndrome.

The Relationship between Trust, Satisfaction and Perceived Performance of Golf Device Data -Focused on the Golf Swing Analyzer- (골프 디바이스 데이터의 신뢰, 만족 및 인지된 경기력의 관계 -스윙 분석기 중심으로-)

  • Han, Jee-Hoon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.196-207
    • /
    • 2021
  • The purpose of this study is to investigate the relationship between trust, satisfaction and cognitive performance of golf participants in golf device, focusing on the swing analyzer. A total of 328 questionnaires were collected. Collected data were analyzed by SPSSWIN and AMOS program and frequency analysis, confirmatory factor analysis, validity test, correlation analysis and structural equation model analysis were performed. The result of the study were as follows. First, the trust of golf participants in golf device data has a positive effect on satisfaction. Second, the trust of golf participants in golf device data does not affect Perceived performance. Third, the satisfaction of golf participants in golf device data does not affect Perceived performance. In conclusion, golf participants' trust and satisfaction of the golf swing analyzer are irrelevant to the perceived performance. In conclusion, it was found that golf participants trusted the data presented through the golf device and obtained satisfactory results. However, in that it did not affect the perceived performance, golf participants can think that golf devices should be used to play golf rather than thinking that golf devices enhance their performance.

Analysis of Network Log based on Hadoop (하둡 기반 네트워크 로그 시스템)

  • Kim, Jeong-Joon;Park, Jeong-Min;Chung, Sung-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.125-130
    • /
    • 2017
  • Since field control equipment such as PLC has no function to log key event information in the log, it is difficult to analyze the accident. Therefore, it is necessary to secure information that can analyze when a cyber accident occurs by logging the main event information of the field control equipment such as PLC and IED. The protocol analyzer is required to analyze the field control device (the embedded device) communication protocol for event logging. However, the conventional analyzer, such as Wireshark is difficult to process the data identification and extraction of the large variety of protocols for event logging is difficult analysis of the payload data based and classification. In this paper, we developed a system for Big Data based on field control device communication protocol payload data extraction for event logging of large studies.

A Design of BJT-based ESD Protection Device combining SCR for High Voltage Power Clamps

  • Jung, Jin-Woo;Koo, Yong-Seo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.3
    • /
    • pp.339-344
    • /
    • 2014
  • This paper presents a novel bipolar junction transistor (BJT) based electrostatic discharge (ESD) protection device. This protection device was designed for 20V power clamps and fabricated by a process with Bipolar-CMOS-DMOS (BCD) $0.18{\mu}m$. The current-voltage characteristics of this protection device was verified by the transmission line pulse (TLP) system and the DC BV characteristic was verified by using a semiconductor parameter analyzer. From the experimental results, the proposed device has a trigger voltage of 29.1V, holding voltage of 22.4V and low on-resistance of approximately $1.6{\Omega}$. In addition, the test of ESD robustness showed that the ESD successfully passed through human body model (HBM) 8kV. In this paper, the operational mechanism of this protection device was investigated by structural analysis of the proposed device. In addition, the proposed device were obtained as stack structures and verified.