• 제목/요약/키워드: On line monitoring

검색결과 1,212건 처리시간 0.052초

Monitoring observation of PG0934+013 using The Southern African Large Telescope

  • Park, Dawoo;Woo, Jong-Hak;Romero-Colmenero, Encarni;Crawford, Steven M.;Barth, Aaron J.;Pei, Liuyi
    • 천문학회보
    • /
    • 제38권2호
    • /
    • pp.54-54
    • /
    • 2013
  • We performed spectroscopic and photometric monitoring observations of a QSO, PG0934+013 for a reverberation-mapping analysis, using the 9-m Southern African Large Telescope (SALT) for spectroscopy and the 2-m Faulkes Telescope North and the South for photometry. The monitoring campaign was carried out for 5 month between December 2012 to April 2013, providing 20 spectroscopic epochs and ~40 photometric epochs. Based on the obtained spectra, which typically have a signal-to-noise ratio to 30-60, we performed multicomponent decomposition using various components, i.e., power-law continuum, FeII emission complex, and broad and narrow emission lines, to properly measure the Hbeta line flux. After a flux normalization using [O III] 5007 line luminosity, we obtained a rms spectrum from all epochs, which shows clear variability of Hbeta line. We find that Hbeta line flux decreases by ~20% during the monitoring period while the continuum flux obtained from the aperture photometry based on the imaging data, shows similar variability. The current Hbeta light curve shows monotonic decrease and a reliable cross correlation analysis between Hbeta and continuum light is difficult. Nevertheless, we obtained a preliminary lag measurements as ~24 light days.

  • PDF

13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석 (Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings)

  • 장정호;이동근;이흥호
    • 조명전기설비학회논문지
    • /
    • 제25권11호
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

On-line monitoring system 개발에 관한 음극 액상 글로우 방전의 기초 연구 (Fundamental study of electrolyte cathode atomic discharge for development of on-line monitoring system)

  • 김경미;우영아;조원보;김효진
    • 분석과학
    • /
    • 제15권6호
    • /
    • pp.496-501
    • /
    • 2002
  • Electrolyte cathode atomic discharge (ELCAD)는 용액 중에 포함된 미량 중금속을 연속 자동적으로 측정하기 위한 새로운 광학 측정기로서 플라스마에 의한 중금속들의 방출 강도를 측정하는 원자방출 분광법의 하나이다. 특히 이 방법은 검액을 전처리하지 않고 직접 분석할 수 있기 때문에 온라인 (on-line) 현장분석이 가능하다. ELCAD에서는 분위기 가스로 공기를 이용하고, 양극부분에 백금 전극을 사용하며, 음극에서는 연속적으로 전해질 시료를 주입하면서 플라스마를 형성하면서 미량의 중금속을 분석할 수 있다. 액상 글로우 방전의 기초 특성 연구로는 철의 원자 방출선 세기를 구한 다음 Einstein-Boltzmann식을 사용하여 플라스마 온도를 구한 다음 구리, 납, 철 및 니켈의 미량 분석 및 간섭 현상에 대해서 연구하였고, 검출 한계를 구하였다.

경계스캔 구조를 사용한 시스템의 온라인 버스 모니터링 (On-line Bus Monitoring of a System Using Bondary-Scan)

  • 송동섭;배상민;강성호;박영호
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권12호
    • /
    • pp.675-682
    • /
    • 2000
  • When a system is composed of multi-boards, an efficient bus arbitration method for the data transfer bus must be provided for guaranteeing proper operations. In this paper, a new test methodology is developed which is used for testing on-line bus arbitration. In the new test methodology, events that are occurred during bus arbitration are defined, and expected signals during fault-free bus arbitration are compared with the signals captured during on-line bus arbitration using boundary-scan cells. For this, a new test architecture is proposed which is efficient for the maintenance and the repair of multi-board systems. In addition, the new methodology can be used with off-line interconnect test using boundary-scan.

  • PDF

용존산소와 pH의 동시 검출용 광학 센서 막을 이용한 미생물 발효공정의 온라인 모니터링 (On-line monitoring of microorganism cultivation processes using optical sensing membranes for simultaneous detection of dissolved oxygen and pH)

  • 김춘광;이종일
    • KSBB Journal
    • /
    • 제24권1호
    • /
    • pp.106-112
    • /
    • 2009
  • An optical sensing membrane has been fabricated to measure the concentration of dissolved oxygen(DO) and pH value simultaneously. It has employed HPTS as a pH sensitive dye and a ruthenium(II) complex as a DO sensitive dye. The sensing membrane has been applied to wells in a 24-well microtiter plate. Using the 24-well microtiter plate the concentrations of dissolved oxygen and pH values have been on-line monitored during the cultivations of E.coli DH5${\alpha}$, B.cereus 318 and P.pastoris X-33. On-line monitoring of DO and pH in microorganism cultivation processes showed good performance of the sensing membrane containing 5 mM HPTS and 2 or 5 mg/mL Rudpp.

발전기 고정자 권선의 운전중 부분방전 모니터링 시스템 개발 (Continuous On-Line Partial Discharge Monitoring System for Stator Winding of Generators)

  • 전정우;황돈하;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1734-1736
    • /
    • 1998
  • On-line partial discharge monitoring system for generator stator insulation is developed. This system consists of remote and host units. The remote unit detects partial discharge signals from SSC(Stator Slot Coupler) installed between wedge and stator windings. The host unit monitors the condition of winding insulation. This system will be used as a module of a generator on-line monitoring system utilizing global network.

  • PDF

정면밀링작업에서 절삭력을 이용한 On-Line 표면조도 감시에 관한 연구 (A Study of the on-Line Surface Roughness Monitoring using the Cutting Force in Face Milling Operation)

  • 백대균;고태조;김희술
    • 한국정밀공학회지
    • /
    • 제14권1호
    • /
    • pp.185-193
    • /
    • 1997
  • This paper presents the on-line monitoring of the surface roughness in a face milling operation. The cut- ting force was used to monitor the surface roughness, since the insert run-outs not only deteriorate surface roughness but also change cutting force. AR model and band energy method were taken to extract the fea- tures from the cutting force. The features extracted from AR modelling are more accurate about the moni- toring than those from band energy method, whereas, the computing speed of the former is slow. An artifi- cal neural network discriminated the level of the surface roughness by using the features extracted via signal processing.

  • PDF

무선센서를 이용한 지하전력구의 케이블 접속함 표면온도감시시스템 개발 (A Development of Surface Temperature Monitoring System for Underground Tunnel Cable Joint using Wireless Sensor)

  • 김영일;송재주;신진호;이봉재;조선구
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1879-1884
    • /
    • 2007
  • In the electric power industry, it is important that the supply of energy must be guaranteed. Many power utilities control and supervise the transmission line to avoid power failures. In case of underground tunnel, some troubles are reported in cable joint. To stabilize the power, it is needed to monitor the cable joint. Many researches of cable joint monitoring have been going on by partial discharge measurement and temperature measurement using optical cable. These methods need much cost to install and maintain, so it is only used in critical transmission line. In this research, we use wireless sensor technology, because of its low cost and easy installation. We develop the temperature monitoring system for cable joint. Temperature sensor is installed on the surface of cable joint and sends data to server through router node using wireless network. Generally Ad hoc routing is searched in wireless network. However, in this research, we design the static linear routing mechanism, which is suitable for electric power line monitoring and analyze the life time of the sensor node by measuring the amount of the battery consumption.

고차 시간-주파수 해석과 신경망 회로를 이용한 냉장고 압축기의 건전성 연구 (A Study on Health Monitoring of a Refrigerator Compressor Based on Higher Order Time-Frequency Analysis and Artificial Neural Network)

  • 신태진;이상권;장지욱
    • 한국정밀공학회지
    • /
    • 제29권12호
    • /
    • pp.1313-1320
    • /
    • 2012
  • Condition monitoring of the reciprocating compressor is important task. As a traditional method, health monitoring system of refrigerator depends on decision of a skilled person based on his experience. However, the skilled person cannot monitor all the compressors completely. If a sampled compressor is faulty, thousands of compressors manufactured at that place are regarded as faulty compressors. Therefore it is necessary to monitor all compressors in the production line. In the paper real time health monitoring system is developed based on high order time frequency method and artificial neural network. The system is installed in the mass production line. The result of the application has been very successful, and currently the system is working very well on the production line.

A Framework for Wide-area Monitoring of Tree-related High Impedance Faults in Medium-voltage Networks

  • Bahador, Nooshin;Matinfar, Hamid Reza;Namdari, Farhad
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.1-10
    • /
    • 2018
  • Wide-area monitoring of tree-related high impedance fault (THIF) efficiently contributes to increase reliability of large-scaled network, since the failure to early location of them may results in critical lines tripping and consequently large blackouts. In the first place, this wide-area monitoring of THIF requires managing the placement of sensors across large power grid network according to THIF detection objective. For this purpose, current paper presents a framework in which sensors are distributed according to a predetermined risk map. The proposed risk map determines the possibility of THIF occurrence on every branch in a power network, based on electrical conductivity of trees and their positions to power lines which extracted from spectral data. The obtained possibility value can be considered as a weight coefficient assigned to each branch in sensor placement problem. The next step after sensors deployment is to on-line monitor based on moving data window. In this on-line process, the received data window is evaluated for obtaining a correlation between low frequency and high frequency components of signal. If obtained correlation follows a specified pattern, received signal is considered as a THIF. Thereafter, if several faulted section candidates are found by deployed sensors, the most likely location is chosen from the list of candidates based on predetermined THIF risk map.