$SF_6$ 가스절연변압기에서 권선의 섹션에 대한 절연내력 연구 (A Study on the Dielectric Strength in Section of Winding in SF6 Gas Transformer)

  • 허우행;하영식;홍정표;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.152-158
    • /
    • 2000
  • This paper deal with the experimental discussion about the impulse and AC dielectric strength of SF6 gas insulated transformer. Test sample is measured the dielectric breakdown voltage about modeling of the first and second section which is the weakest for surge voltage. The AC breakdown voltage is appeared 1.4 times than impulse breakdown voltage, so we can estimate that the impulse breakdown voltage is severe to AC breakdown voltage, and when the impulse is applied, in case of lmm tapping with Nomex paper, the characteristics of dielectric breakdown voltage is same to that in oil immersed transformer when SF6 gas pressure is 2.2kg/$cm^2$G.

  • PDF

회전원통을 이용한 유입 변압기의 유동대전에 관한 연구 (A Study on the Static Electrification for Oil-Immersed Power Transformers Using a Spinning Cylinder)

  • 정용기;권동진;손철근;곽희로
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1993년도 추계학술발표회논문집
    • /
    • pp.83-88
    • /
    • 1993
  • This paper persents the measurement method using a spinning cylinder system for stream-ing electrification of transformer oil. The spinning cylinder system has a simple mechan-ical construction, and requires less oil com-pared to the other methods. Alse, the effects of various admixtures on the static electri-fication and properties of tranformer oil can be easily investigated. Experiments showed that addition of the BTA reduced the streaming electrification and the polarity of static electrification wasconver-ted to negative at 50 ∼ 70[ppm] of BTA

  • PDF

광유 및 식물성 절연유에서 절연지의 열적 열화 특성 평가 (The Evaluation of Thermal Aging for Insulation Paper with Mineral and Vegetable Oil)

  • 이병성;송일근;김동명;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1558-1560
    • /
    • 2004
  • Liquid-immersed pole transformers have utilized an insulation system consisting of natural cellulose-based materials and mineral oil for many years. If the transformers are installed with the abruptly changing load over limitation, its insulation materials are apt to unexpected aging with high temperature. Therefore we have been conscious of developing a transformer that is more thermally stable then conventional types. To measure temperature distribution in the winding of conventional and newly designed transformers, temperature sensors were installed fordirect reading of oil and conductor temperatures at transformers. And we conducted accelerating aging test for these transformers. The measuring data had made use of the design to hybrid insulation system. Also we could find the possibility of this insulation system to apply in pole mounted transformers.

  • PDF

가스센서를 이용한 부분방전특성에 따른 유중수소가스 측정연구 (Measurement Technology of the Dissolved Hydrogen Gas Due to Partial Discharge in Oil using Gas Sensor)

  • 허종철;선종호;강동식;정주영;추영배;박정후
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1784-1789
    • /
    • 2009
  • This paper describes the measurement technology of the dissolved hydrogen gas due to partial discharge in oil using gas sensor. For higher resolution and less error in measurement of the dissolved hydrogen gas in oil, the sensor outputs with ambient temperature which affect the sensor output characteristics should be considered. The sensor output trends with ambient temperature and the properties of the dissolved hydrogen gas in oil with partial discharge characteristic were analyzed through the test results. It was indicated that the sensor peak and the base voltage with measuring time were affected by ambient temperature and the measurement errors of the sensor output by temperature were reduced by using the difference between the peak and the base voltage rather than just the peak voltage. In addition, the hydrogen gas sensor outputs were increased with the increase of partial discharge energy.

유입 변압기에서 폴디드 다이폴형 센서의 부분방전 펄스 검출 특성 (The Detection Characteristics of the Partial Discharge Pluses with Folded Dipole Type Sensors in the Oil Transformers)

  • 김광화;이상화;선종호;강동식;김재철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권10호
    • /
    • pp.485-491
    • /
    • 2006
  • This paper describes that the distribution of electromagnetic field occurred by PD(Partial Discharge) pulse was calculated with simulation program and characteristics of calibration and PD pulses measured with folded dipole types sensors were analyzed. As the distribution of electromagnetic field in simulation was very random the wide band measuring methods were good. Therefore three folded dipole antenna types sensors which had different their widths were designed and made. The signal according to direction and distance between sensor and pulse source in these sensor was measured and the spectrum of surface PD were acquired in the experiment of model transformer. In this result the characteristics of sensor which had middle width was better than others and the main spectrum of PD signals in surface discharge were existed in around 220MHz, 320MHz and from 450MHz to 750MHz.

저손실형 몰드 단권변압기 개발 (A study on the Development of Low-loss Type Mold Autotransformers)

  • 이종수;신명호;문병철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.92-94
    • /
    • 2003
  • The autotransformer currently used on the electric railway system is made of class A insulation material and uses the paper insulation method. As a power converter supplying power to the trolley wire, the autotransformer is one of critical equipment in the railway system. In the autotransformer, load irregularly changes and overload often occurs. These cause overheating of the autotransformer and facilitate deterioration of the autotransformer resulting in burnout accidents due to insulation breakdown. Also, the current autotransformer has poor insolation and short-circuit strength which often badly affect the service life of the transformer, and needs to improve its quality urgently. To overcome one of existing shortcomings of the mold transformer, manufacturers use epoxy resins that have superior flame retardancy to get rid of fro and explosion possibilities during accidents. Currently, new mold transformers are used in indoor distribution facilities with fire-fighting equipments. Coils molded in epoxy resins do not have their insulation performance compromised by humidity, dust, etc enabling easy inspection and maintenance. Comparing to the oil immersed transformer, the mold transformer does not have any concern about environmental pollutions by oil leak or replacement Therefore, to reduce breakdowns and improve reliability of the autotransformer, it is necessary to develop a new mold autotransformer with low loss suitable for our environment to suppress breakdowns of the autotransformer and improve the reliability. This study is about development of a low-loss mold autotransformer necessitated by reasons mentioned earlier.

  • PDF

Study on Decomposition Gas Characteristics and Condition Diagnosis for Gas-Insulated Transformer by Chemical Analysis

  • Kim, Ah-Reum;Kwak, Byeong Sub;Jun, Tae-Hyun;Park, Hyun-Joo
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.447-454
    • /
    • 2020
  • Since SF6 gas was discovered in the early 1900s, it has been widely used as an insulation material for electrical equipment. While various indicators have been developed to diagnose oil-immersed transformers, there are still insufficient indicators for the diagnosis of gas-insulated transformers. When necessary, chemical diagnostic methods can be used for gas-insulated transformers. However, the field suitability and accuracy of those methods for transformer diagnosis have not been verified. In addition, since various types of decomposition gases are generated therein, it is also necessary to establish appropriate analysis methods to cover the variety of gases. In this study, a gas-insulated transformer was diagnosed through the analysis of decomposition gases. Reliability assessments of both simple analysis methods suitable for on-site tests and precise analysis methods for laboratory level tests were performed. Using these methods, a gas analysis was performed for the internal decomposition gases of a 154 kV transformer in operation. In addition, simulated discharge and thermal fault experiments were demonstrated. Each major decomposition gas generation characteristics was identified. The results showed that an approximate diagnosis of the inside of a gas-insulated transformer is possible by analyzing SO2, SOF2, and CO using simple analysis methods on-site. In addition, since there are differences in the types of decomposition gas generation patterns with various solid materials of the internal transformer, a detailed examination should be performed by using precise analysis methods in the laboratory.

Comparative Study of DC Breakdown and Space Charge Characteristics of Insulation Paper Impregnated with Natural Ester and Mineral Oil

  • Hao, Jian;Zou, Run-Hao;Liao, Rui-Jin;Yang, Li-Jun;Liao, Qiang;Zhu, Meng-Zhao
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1682-1691
    • /
    • 2018
  • Natural ester is a suitable substitute for mineral oil and has been widely used in AC transformer in many countries. In order to further application of natural ester in direct current (DC) equipment, it is needed to investigate its long term insulation property under DC condition. In this paper, a thermal ageing experiment was conducted for both mineral oil-paper and natural ester-paper insulation. The DC breakdown and space charge characteristics of insulation paper impregnated with natural ester and mineral oil was compared. Results show that the resistivity of the paper immersed in natural ester and mineral oil both increase as the ageing goes on. While insulation paper impregnated with natural ester has higher resistivity and DC breakdown voltage than the paper impregnated with mineral oil. The DC breakdown voltage for the oil impregnated insulation paper being DC pre-stressing is higher than that without pre-stressing. The average DC breakdown field strength difference between the test with pre-stressing and without pre-stressing clearly shows that there is an apparent enhancement effect for the homo-charge injection on the DC breakdown.

안테나를 이용한 몰드변압기 절연결함 측정기법 연구 (Measurement and Analysis of Insulation Detects of Cast-resin Transformers using Antenna)

  • 최명일;김재진;한가람;전정채;이현옥
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1937-1942
    • /
    • 2016
  • Unlike oil immersed transformers, cast-resin transformers have the solid insulator 'epoxy resin' in sealed structure. Therefore, they reveal a lot of limitations in checking aging conditions and predicting an accident. This study analyzed the characteristics of Cast-resin transformers by the measurement distance and measurement sensitivity with a corona defect sample, using antenna sensor. Therefore, the experiment has proven that the antenna sensor-based measurement method proposed in this study is able to detect the insulation defect location of the cast-resin transformer, unlike conventional measurement methods. It is expected that the result of this study will be used to develop a new type of measuring method in order to measure insulation defects and to use in safety inspection of domestic cast-resin transformers.

유입식변압기 감시진단 기술로드맵 (Technical road map for monitoring and diagnosis of oil immersed transformer)

  • 선종호;이상화;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.13-15
    • /
    • 2005
  • 본 연구에서는 진단연구회에서 게획중인 유입식변압기의 감시진단기술에 관한 로드맵을 설명하고 있다. 유입식변압기의 용량 및 절연기술의 변천과 최근의 절연유 및 고체절연물, 변압기설계기술 연구동향에 대하여 설명하였다. 또한 변압기의 열화기구 및 현재의 감시진단 기술분석을 통한 기술로드맵을 작성하였다. 기술로드맵에서는 유입식변압기의 고장을 신뢰성 있고 효율적으로 수행할 수 있는 센싱기술, 신호처리기술, 데이터분석기술, 장치개발기술 등을 기술하였다.

  • PDF