유입변압기용 절연유의 절연파괴특성 (Electrical Breakdown Properties of Insulating Oils for oil-immersed transformer)

  • 이인성;신현택;이종필;이수원;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.605-608
    • /
    • 2001
  • With the intention of investigating the breakdown properties of oil-immersed transformer oils in temperature range of 20∼100[$^{\circ}C$], we are made researches AC breakdown in the gap of 500∼2,500[$\mu\textrm{m}$]. The classification for the physical properties of oil for oil-immersed transformer by FTH and $^1$H-NMR experiments was confirmed to type of mineral oils. As the dependance of breakdown properties due to electrode gap length variation, breakdown voltage was found increasing according to the increase of gap, while dielectric strength was decreasing. As a result the characteristics for AC breakdown, It goes to prove that the breakdown voltage was increased to 90[$^{\circ}C$] but decreased over 90[$^{\circ}C$] in the temperature range. Also, breakdown voltage was found increasing in the increase of gap and the rising of temperature according to Weibull distribution.

  • PDF

유체 온도 변화를 고려한 선 접촉면사이의 탄성유체윤활 해석 (n Analysis of Elastohydrodynamic lubrication in Line Contacts-the effect of temperature variation)

  • 서민호;임윤철
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.364-373
    • /
    • 2001
  • This paper describes the variation of lubricant's temperature effects on elastohydrodynamic lubrication. The Newton-Raphson technique was used to solve the simultaneous system of Reynolds and elasticity equations. To show effects of lubricant's temperature, average temperature across the oil film was calculated using the energy equation. Pressure distribution, film shape, and temperature distribution were obtained for fully flooded conjunctions, and various dimensionless speed parameters while load and material parameters were held constant. Minimum film thickness were obtained for various material properties while load and velocity were held constant. It is drawn that the thermal effects have a strong influence on a minimum film thickness under high rolling velocity and slip ratio.

  • PDF

이중냉각자켓의 냉각유량에 따른 모터내장형 고속주축계의 열특성

  • 최대봉;황주호;임경진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.239-243
    • /
    • 1997
  • The heat generation is the most important problem in the motor integrated spindle. Double cooling jacket in necessary to reduce the thermal displacement and to get the stable temperature disribution for the housing. In this study, the effects of temperature distribution and thermal displacement for the spindle system according to the variation of cooling oil flow rate are investigated experimentally on the motor-integrated spindle with double cooling jacket system. The experimental spindel system is composed with the angular contact steel ball bearings, oil-air lubrication, air or oil jacket cooling system.

상부에 냉각면이 있는 정방형내 이종유체의 저온거동에 관한 실험적 연구 (An Experimental Study on Low-Temperature Behavior of Stratified Fluids in a Square Cavity with Upper Cooling Surface)

  • 이동석;김병철
    • 태양에너지
    • /
    • 제20권1호
    • /
    • pp.55-62
    • /
    • 2000
  • An experimental study on the stratified fluids with water and silicon oil of same volume in the cavity with upper cooling surface was carried out to investigate the flow characteristics, heat transfer through the interface of fluids, and the applications of thermal behaviors in a square cavity. The experiments were performed with variation of initial temperature and cooling surface temperature. The temperature drop of oil was faster than that of water and freezing was initiated from the interface of oil and water and propagated downward. For the water above $4^{\circ}C$, the cooling rate was faster than that below $4^{\circ}C$ and showed almost same temperature distribution but for the water that of below $4^{\circ}C$, it showed the stable stratified temperature distribution. The lower the initial temperature and the higher the cooling surface temperature was, the longer the supercooling duration.

  • PDF

변압기의 고장검출을 위한 유중 코로나 특성 연구 (Transformer diagnosis using characteristics of corona in Oil)

  • 권태원;곽희로;김재철;김응상;박민규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1989년도 추계학술발표회논문집
    • /
    • pp.65-70
    • /
    • 1989
  • This paper presents resarch results on the use of a corona detector and a pulse counter in order to diagnose for oil transformers. Using these experimental apparatus, tests were carried out on a typical transformer oil containing different carbonized paper and various moisture contents to measure the picocoulomb val-ues and pulse count. Through the result of this study it was found that the picocoulomb values and pulse count of corona were depended on the getting stained in transformer oil. The amplitude of the partial discharge amount and the number of pulse were decreased up to 70 [。c] and then was increased as the oil temperature goes up. It was concluded that the determinati-on level for diagnosis of oil transform-er was taken into account the temperatu-er of transformer oil, The use of pulse counter method, which have been taken the same property of voltage and temperature variation for the corona measurement mothod, considera-bly increase insulator avilability.

  • PDF

Thermal Stability and Lifetime Prediction of PAG and POE Oils for a Refrigeration System

  • Park, Keun-Seo;Kang, Byung-Ha;Park, Kyoung-Kuhn;Kim, Suk-Hyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권2호
    • /
    • pp.78-83
    • /
    • 2007
  • An experimental study has been carried out to analyze the thermal stability and to estimate the lifetime of refrigerating lubricants. PAG and POE oil are considered as test oils in this study. The viscosity of PAG and POE oil was measured by the vibration type viscometer while temperature is varied periodically in the range of $0^{\circ}C{\sim}100^{\circ}C$. In order to estimate lifetime of PAG and POE oil with temperature, the viscosity was measured while the test temperature of oils was maintained continuously at $180,\;200\;and\;220^{\circ}C$. The lifetime of oils is estimated as the decrease in viscosity change by 15%. The results indicate that the reduction rates of viscosity of PAG and POE oil are less than 5% after 510 temperature variation cycles. However, when the oils are kept at high temperature, it is found that the lifetimes of PAG oil is seen to be 244, 177 and 89 hours at the test temperature of $180,\;200\;and\;220^{\circ}C$, respectively, where as the lifetimes of POE oil are estimated to be 1,744, 1,007 and 334 hours at the temperature of $180,\;200\;and\;220^{\circ}C$, respectively. Thus, the lifetime of POE oil is found to be much longer than that of PAG oil. The lifetime correlations of PAG and POE oil are also obtained by Arrhenius's equation method in this paper.

석유류 POOL FIRE에 있어서의 열적인 영향(I) (Thermal Effects in the Pool Fire of Fuels(I))

  • 정국삼;강민호;이덕영
    • 한국안전학회지
    • /
    • 제11권1호
    • /
    • pp.75-83
    • /
    • 1996
  • This paper was concerned with pool fire about many used kerosene and diesel oil. In order to know the thermal effects of kerosene and diesel oil, temperature change in the pool fire of these fuels were obtained as a variation of combustion time and the tank's height and diameter by using the data acquisition system, And fuel combustion velocity were derived as a function of the diameter and wall thickness of tanks and combustion time. As a result, when the tank's height was 15㎝, the greater diameter the higher temperature rising regardless of tank's wall thickness and fuels. But, when the tank's height is 30㎝, temperature rising was not higher than 15㎝. Also, temperature rising in the pool fire of kerosene much higher than diesel oil. Kerosene's combustion velocity was about two times faster than diesel oil. And, kerosene's combustion velocity was increased according to the increasing of tank's diameter and combustion time. But, diesel oil's combustion velocity was a little increased or not. Surrounding temperature change of tank with the pool fire was obtained temperature distribution of 0∼35℃ according to the change of tank's diameter and distance from the tank's wall.

  • PDF

6속 자동변속기 밸브바디의 윤활오일유량 분배 특성 연구 (A Study on the Lubrication Flow Distribution in a Six-speed Automatic Transmission Valve Body)

  • 김진용;나병철;이계철
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.79-84
    • /
    • 2011
  • In general, a valve body of the automatic transmission(AT) is controlled by the clutch, the brake and lubricating oil flow in a hydraulic system and lubricant flow for each valve can be adjusted independently. To increase the lifetime of AT, the lubrication flow rate in a valve body for a 6 speed AT based parallel hybrid electric vehicle must be provided with proper oil distribution and control. In this study, we carried out several experiments without the inner parts of AT and with a AT assembly. The variation of the flow rate on oil temperature and pressure between an oil supply port and the outlets of the lubrication port was evaluated and analyzed. In the case of AT without the inner parts, it was evident that as the oil required for an operation of the clutch and brake was discharged from the outlet port, the flow rate from each lubrication port is decreased. However, the flow rate of the AT assembly was slightly increased. In addition, the lubrication flow rate was increased with increasing the oil temperature, and also it was reduced with increasing the oil pressure. Details of the resulting data are discussed.

반능동 제어용 대칭 실린더형 유압 감쇠기의 동적 거동 (Dynamic Behavior of a Symmetric Cylinder Type Hydraulic Damper for Semi-Active Control)

  • 이일영
    • 동력기계공학회지
    • /
    • 제6권2호
    • /
    • pp.82-87
    • /
    • 2002
  • For the dynamic behavior evaluation of a semi-active vibration control system, it is very important to use an accurate mathematical model for the hydraulic damper applied to the control system. In this study, a mathematical model for a symmetric type hydraulic damper was suggested. In this model, the effects of gas volume and oil temperature variation on the bulk modulus of oil were considered. The dynamic behavior of the damper was investigated by experiments and simulations. It was confirmed that the pressure variation, damping force, and mean pressure variation could be estimated with comparatively good precision by the suggested mathematical model. Moreover, it was shown that excessive pressure rise can be generated by the oil expansion due to the heat energy transformed from the exciting energy of the damper for a short period of the damper operation.

  • PDF

Heat Generation Model of Angular Contact Ball Bearing with Oil-Air Lubrication

  • Na, Hee-Hyeong;Rhim, Yoon-Chul
    • KSTLE International Journal
    • /
    • 제1권1호
    • /
    • pp.63-68
    • /
    • 2000
  • Angular contact ball bearings are mainly used in the spindle, which requires high speed and stiffness. The heat generation is studied by experiments and simulations using a pair of angular contact ball bearings. The temperature variation of inner and outer races and the temperature increment distribution are measured by using thermocouples for the rotational speed, preload, viscosity of lubricant. The measured values from experiments are used to estimate the heat conduction rate. The method of oil-air lubrication is used for the experiment. The amount of conduction heat transfer to the test spindle and the convection heat transfer coefficients long the spindle are computed by using inverse method with temperature increment distribution. Total heat generation rate is estimated with the heat partition rate which is calculated from temperatures of inner and outer races. In addition, the empirical factor of oil-air lubrication method for Palmgren's heat generation model is suggested. The empirical friction coefficients, which are obtained from the experiments, depend on the preload condition, and can give us more accurate estimation of the heat generation in ball bearings.