A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications (구치용 도재소부금관과 전부도재관에 파절을 일으키는 한국음식에 관한 연구)

  • Kim, Jeong-Ho;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.156-163
    • /
    • 2009
  • Statement of problem: Recently, there have been increased esthetic needs for posterior dental restorations. The failure of posterior dental ceramic restoration are possible not only by the characters of the component materials but also by the type of food. Purpose: The research aim was to compare the in vitro fracture resistance of simulated first molar crowns fabricated using 4 dental ceramic systems, full-porcelain-occlusal-surfaced PFG, half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon and selected Korean foods. Material and methods: Eighty axisymmetric crowns of each system were fabricated to fit a preparation with 1.5- to 2.0-mm occlusal reduction. The center of the occlusal surface on each of 15 specimens per ceramic system was axially loaded to fracture in a Instron 4465, and the maximum load(N) was recorded. Afterwards, selected Korean foods specimens(boiled crab, boiled chicken with bone, boiled beef rib, dried squid, dried anchovy, round candy, walnut shell) were prepared. 15 specimens per each food were placed under the Instron and the maximum fracture loads for them were recorded. The 95% confidence intervals of the characteristic failure load were compared between dental ceramic systems and Korean foods. Afterwards, on the basis of previous results, 14Hz cyclic load was applied on the 4 systems of dental ceramic restorations in MTS. The reults were analyzed by analysis of variance and Post Hoc tests. Results: 95% confidence intervals for mean of fracture load 1. full porcelain occlusal surfaced PFG Crown: 2599.3 to 2809.1 N 2. half porcelain occlusal surfaced PFG Crown: 3689.4 to 3819.8 N 3. Ice Zirkon Crown: 1501.2 to 1867.9 N 4. Empress 2 Crown: 803.2 to 1188.5 N 5. boiled crab: 294.1 to 367.9 N 6. boiled chicken with bone: 357.1 to 408.6 N 7. boiled beef rib: 4077.7 to 4356.0 N 8. dried squid: 147.5 to 190.5 N 9. dried anchovy: 35.6 to 46.5 N 10. round candy: 1900.5 to 2615.8 N 11. walnut shell: 85.7 to 373.1 N under cyclic load(14Hz) in MTS, fracture load and masticatory cycles are: 1. full porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 4796.8-9321.2 cycles under 2224.8 N(round candy)load, no fracture under smaller loads. 2. half porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 881705.1-1143565.7 cycles under 2224.8 N(round candy). no fracture under smaller loads. 3. Ice Zirkon Crown fractured at 95% confidence intervlas of 979993.0-1145773.4 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. 4. Empress 2 Crown fractured at 95% confidence intervals of 564.1-954.7 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. Conclusion: There was a significant difference in fracture resistance between experimental groups. Under single load, Korean foods than can cause fracture to the dental ceramic restorations are boiled beef rib and round candy. Even if there is no fracture under single load, cyclic dynamic load can fracture dental posterior ceramic crowns. Experimental data with 14 Hz dynamic cyclic load are obtained as follows. 1. PFG crown(full porcelain occlusion) was failed after mean 0.03 years under fracture load for round candy(2224.8 N). 2. PFG crown(half porcelain occlusion) was failed after mean 4.1 years under fracture load for round candy(2224.8 N). 3. Ice Zirkon crown was failed after mean 4.3 years under fracture load for boiled chicken with bone(382.9 N). 4. Empress 2 crown was failed after mean 0.003 years under fracture load for boiled chicken with bone(382.9 N).

Influence of bearing surface angle of abutment screw on mechanical stability of joint in the conical seal design implant system (내부 원추형 연결형태 임플란트에서 지대주 나사머리의 좌면각도가 연결부 기계적 안정성에 미치는 영향)

  • Kim, Joo-Hyeun;Huh, Jung-Bo;Yun, Mi-Jung;Kang, Eun-Sook;Heo, Jae-Chan;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.206-214
    • /
    • 2014
  • This study is to evaluate how different bearing surface angles of abutment screw affect the mechanical stability of the joint in the conical seal design implant system. Materials and Methods: Internal connection type regular implants, two-piece cemented type abutments and tungsten carbide/carbon-coated titanium alloy abutment screws were selected. Titanium alloy screws with conical ($45^{\circ}$) and flat ($90^{\circ}$) head designs which fit on to abutment were fabricated. The abutments were tightened to implants with 30 Ncm by digital torque gauge. The loading was applied once to the central axis of abutment. The mean axial displacement was measured using micrometer before and after the tightening and loading (n = 5). The abutment was tightened to implants with 30 Ncm and T-shape stainless steel crown was cemented. Then the change in the amount of reverse-torque was measured after the repeated loading to the central axis, and the place 5 mm away from the central axis. Compressive bending and fatigue strength were measured at the place 5 mm away from the central axis (n = 5). Results: Both groups showed the largest axial displacement when abutment screw tightening and total displacement was greater in the flat head group compared to conical head group (P < 0.05). However, there were no significant differences in reverse torque value, compressive bending and fatigue strength (P > 0.05). Conclusion: Within the limitations of this study, the abutment screw head design had no effect on two groups regarding the joint stability, however the conical head design affected the settlement of abutment resulting in the reduced total displacement.

Comparison on the Fracture Strength Depending on the Fiber Post and Core Build-up (섬유 강화 포스트와 코어 축성 방법에 따른 파절 강도에 관한 비교)

  • Lee, Ja-Hyoung;Shin, Sooyeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.225-235
    • /
    • 2009
  • A common procedure of restoration of endodonticlly treated tooth with fiber-reinforced post is followed by core build-up after post cementation. However, this technique is complex and time-consuming. The aim of this study was to compare fracture strength of premolar, restored with various methods of core fabrications on fiber-reinforced posts and casting metal restoration. Forty five freshly extracted human mandibular premolars were obtained and devided into 5 groups acconding to the type of post and methods of core build-up. In Group A, D.T. $Light-post^{(R)}$ were cemented with $DUO-LINK^{TM}$ and then $LIGHT-CORE^{TM}$ was used for core restoration. In Group B, D.T. $Light-post^{(R)}$ and $DUO-LINK^{TM}$ were used for cementing in the postspace, and $DUO-LINK^{TM}$ was used again for core restoration. In Group C, $Light-post^{(R)}$ bonding and the core build-up were performed simultaneously by using $DUO-LINK^{TM}$. In Group D, $LuxaPost^{(R)}$ was bonded by using $LuxaCore^{(R)}-Dual$. Again, $LuxaCore^{(R)}-Dual$ was used for core restoration. In Group E, $LuxaPost^{(R)}$ bonding and the core build-up were performed simultaneously by using $LuxaCore^{(R)}-Dual$. Axial reduction was formed parallelly as possible and 45 degree bevel was made at buccal occlusal surface. Crowns were fabricated and cemented. Each tooth was embedded in self-curing acrylic resin to the level of 2mm below the CEJ. Specimens were fixed on universal testing machin such that the axis of the tooth was at 45 degree inclination to the horizontal plane, and compressive force was applied at a crosshead speed of 1mm/min until failure occurred. The mean fracture strength was the highest in group A followed by descending order in group B, D, E and C. However, there were no statistically significant differences between groups with regard to the fracture strength. The type of the post or build-up methods of the core does not seem to influence the fracture strength.

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.

The Study of Bone Healing Response According to the Various Surfaces of the Implant in the Mandible of the Mature Dog (성견 하악골에 식립한 다양한 임플란트 표면에서의 골 치유 양상에 관한 연구)

  • Lim, Hyun-Pil;Kim, Yong-Hak;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Choi, Hong-Ran
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.125-137
    • /
    • 2009
  • There are many reports that these implant surface treatments may affect to cellular reaction in the surface of implant. This study was done by installing the 8 type implant with the variable surface treatment, used or developed, in the mandible of the mature dog to evaluate how the method of surface treatment of the implant can affect to the bone healing by analyzing histologically and histomorphometrically and find out bone healing appearance periodically after installing implant. By using the 8 type implants which have the different surface treatment, 72 implants were installed on the mandible of 9 mature dogs, and 3 dogs were sacrificed on every 2, 4, 8 weeks. After making bone fragment by cutting and managing, we analyzed histologically, then compared with BIC(Bone to implant contact) for the histomorphometrical analysis. In the result of histological analysis, there was large amount of bone formation in good state on the adjacent area of implant in the 2 weeks testing group. At 4 weeks, although there was general bone formation, the new bone was separated with the basal bone. At 8 weeks, the new bone became matured and connected tightly to the basal bone. There was no difference in the each surface of 8 implants. In the result of histomorphometrical analysis, 2 weeks group had considerably lower value than 4 and 8 weeks group, and there was no difference between 4 and 8 weeks group. There was no difference in the each surface treatment of implants.

ORTHODONTIC TRACTION OF HORIZONTALLY ERUPTED LOWER LATERAL INCISOR ON THE LINGUAL SIDE (설측으로 수평 맹출한 하악 측절치의 교정적 견인)

  • Mah, Yon-Joo;Sohn, Hyung-Kyu;Choi, Byung-Jai;Lee, Jae-Ho;Kim, Seong-Oh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.117-123
    • /
    • 2010
  • Tooth eruption is the movement of the tooth from the developing place in the alveolar bone to the functional position in the oral cavity. The permanent incisors originate from the dental lamina on the lingual side of preceding deciduous tooth and erupt to the level of the occlusion through the well developed gubernacular cord. Ectopic eruption is a developmental disturbance in the eruption pattern of the permanent dentition. Most of the ectopically erupted lower incisor has been found in lingual side. The ectopically erupted tooth could be repositioned by orthodontic force in the early mixed dentition, which could help preventing the problems of loss of space and the lingual tilting of the lower anterior teeth. An eight-year-old girl visited the department of pediatric dentistry, Yonsei Dental University Hospital, for the evaluation and the treatment of the lower right lateral incisor, which was horizontally erupted in the lingual side, parallel to the mouth floor. Her tongue was placed on the labial side of that tooth. There was no previous dental history of dental caries or trauma on the pre-occupied primary incisor. Clinical and radiographic examinations including the computed tomography(CT), showed no evidence of dilacerations on root. Therefore, we decided to start active orthodontic traction of the lower right lateral incisor. We designed the fixed type of buccal arch wire and the lip bumper with hook for the traction. Button was attached to the lingual side of the ectopically positioned tooth. Elastic was used between the appliance and the button on that tooth. After the tooth become upright over the tongue level, appliance was change to the removable type and periodic check-up with occlusal guidance was followed to monitor the position of the tooth. In this case using the fixed appliance with modified form of lip bumper and hook embedded in acrylic part instead of extraction was very efficient up-righting the ectopically erupted tooth toward the occlusal plane.

The risk factors for implant survival and marginal bone loss: a retrospective long-term study (임플란트 장기간 유지와 변연골 소실에 영향을 주는 요인들에 대한 후향적 연구)

  • Lee, Eun-Woo;Jung, Ha-Na;Jo, Yujin;Kim, Ok-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.2
    • /
    • pp.97-109
    • /
    • 2022
  • Purpose: This study aims to investigate the risk indicators contributing to implant failure, and analyze the relationship between risk indicators and marginal bone loss (MBL) through long-term follow-up over 3 years. Materials and Methods: From 2003 to 2017, patients' medical charts with a history of dental implant surgery at Chonnam National University Dental Hospital were reviewed retrospectively. The patient's demographic variables, and clinical variables were recorded. Periapical radiographs were used to evaluated the changes in MBL around implants. And we analyzed implant survival rates. Multiple regression analysis with backward elimination was conducted to correlate the patient's clinical variables and implant failure and Pearson correlation analysis was performed to the correlated between implant long-term survival rates and MBL and initial stability. Results: In multiple regression analysis, there was a statistically significant negative correlation between abutment connection type (β = -.189, P < .05), with or without SPT (β = -.163, P < .05), diabetes (β = -.164, P < .05), osteoporosis (β = -.211, P < .05) and MBL. Anticoagulant medication influenced the long-term success rate of implants. PTV values at the second implant surgery showed a statistically significant negative correlation with long-term implant survival (P < .05). Conclusion: For the long-term success of the implant, the appropriate abutment connection type must be selected and the periodic SPT is recommended. Systemic diseases such as diabetes and osteoporosis and anticoagulant medication should be considered. Furthermore, since high PTV at the second implant surgery correlated with the long-term survival rates of the implant, initial stability should be carefully considered before undergoing the prosthetic procedure.

A study on the preorthodontic prediction values versus the actual postorthodontic values in Class III surgery patients (골격성 III급 부정교합 환자에서 술전 교정전 예측치와 교정 후 실측치의 차이에 관한 연구)

  • Hwang, Chung-Ju;Kwon, Hee-Jeong
    • The korean journal of orthodontics
    • /
    • v.33 no.1 s.96
    • /
    • pp.1-9
    • /
    • 2003
  • The purpose of this study was to find out and evaluate discrepancies between preorthodontic prediction values and actual postorthodontic values and factors contributing to it in 45 patients(17 male, 28 female) who were diagnosed as skeletal Class III ma)occlusion and received presurgical orthodontic treatment and orthognathic surgery at Yonsei university dental hospital. Lateral cephalograms were analysed at pretreatment(T1), orthodontic Prediction(T2), immediately before surgery(T3) and designated the landmark as coordinates or X and Y axes. The samples were divided according to ALD, upper and lower incisor inclination(Ul to SN, IMPA), COS, extraction, the position of extracted teeth and the statistical significance was tested to find out the factors contributing to the prediction. The results were as follows: 1. Differences between preorthodontic prediction values and actual postorthodontic values(T2-T3) were statistically significant(p<0.05) in the x coordinates of U6mbc, L1x and in y coordinates of U1i, U1x, U6me, U6mbc, L6mbc 2. The accuracy of prediction is relatively higher in horizontal changes compared to vortical changes. 3. The statistical significance(p<0.05) between prediction and actual values is observed more in the landmarks of the maxilla than the mandible. 4. Differences between prediction and actual values of incisor and first molar were statistically significant(p<0.05) according to extraction vs non-extraction, extraction type, ALD in the maxilla and according to ALD, IMPA in the mandible. Discrepancies between preorthodontic prediction values and actual postorthodontic values and factors contributing to the prediction must be considered in treatment planning of Cl III surgical patients to increase the accuracy of prediction. Furthermore future investigations are needed on the prediction of vortical changes.

Flexural strength of various kinds of the resin bridges fabricated with 3D printing (3D 프린팅으로 제작된 여러 종류의 레진브릿지의 굴곡강도에 대한 연구)

  • Park, Sang-Mo;Kim, Seong-Kyun;Park, Ji-Man;Kim, Jang-Hyun;Jeon, Yoon-Tae;Koak, Jai-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.260-268
    • /
    • 2017
  • Purpose: Manufacturing with AM (Additive manufacturing) technique has many advantages; but, due to insufficient study in the area, it is not being widely used in the general clinic. In this study, differences of flexural strength among various materials of 3 unit fixed dental prosthesis were analyzed. Materials and Methods: A metal jig for specimens that had a 3-unit-fixed dental prosthesis figure were fabricated. The jigs were made appropriately to the specifications of the specimens. Three different kinds of materials of specimens which were NC (mathacrylic esther based), DP-1 (Bisphenol A epoxy acrylate type oligomer based), and DT-1 (urethane acrylate based) were printed with DLP machine. Five specimens for each kind of material were printed with an angle of $30^{\circ}$ from the horizontal surface. The specimens were placed on the jig and the flexural strength was measured and recorded using Universal testing machine. The recorded data was analyzed in SPSS using One-way ANOVA and Tukey HSD to determine the significance of the differences of flexural strength among the groups. Results: The flexural strengths of each group were the followings: NC, $1119{\pm}305$ N; DP-1, $619{\pm}150$ N; DT-1, $413{\pm}65N$. Using One-way ANOVA and Tukey Honestly Significant Difference test, significant difference was found between NC and the other groups (P < 0.05), but there was no significant difference between DP-1 and DT-1 (P > 0.05). Conclusion: Higher flexural strength was shown in 3-unit-fixed dental prosthesis that were 3D printed using a DLP machine with NC material.

A study on the smile of Korean Youth compared with twenty years ago (20년전과 비교한 한국청년의 미소 변화에 관한 연구)

  • Beom, Seung-Gyun;Jung, Ji-Hye;Kim, Tae-Young;Lee, Kyung-Eun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.162-168
    • /
    • 2012
  • Purpose: Teeth are generally exposed when people smiling. Moreover, the exposed teeth and soft tissue when smiling becomes an important guideline for esthetically prosthetic restoration. This research is to compare and find out differences of Korean young men's smile living in presence and twenty years ago. Materials and methods: Subjects, 100 young men (50 male and 50 female), were required about several aspects; normally developed physical condition, no psychological or genetic disorders, a fine face with no loss of teeth, no experience in orthodontic or prosthetic treatment, relatively normal occlusion, aged between 20-29. The photos of the subject at rest position and front face when fully smiled were taken three times. 100 photos (50 male and 50 female) were chosen at random from the 240 university students' smile photos taken by Yoon and his colleagues in 1991. By Hulsey's method of measuring smile, several factors; the change of upper lip curvature, the change of the relation between the upper lip and teeth, parallelism between Mx. incisor and lower lip, contact relation between Mx. incisor and lower lip and teeth displayed in a smile, were measured and analyzed. Meanwhile, ten dentists assessed aesthetic evaluation about men and women's smile for twice and recorded and compared smile score. The -test (P<.05) was used to compare the measured value. The difference of smile score was analyzed by t-test (P<.05). Results: The smile score calculated in 2011 (60.22) was higher than that of 1991 (52.80). Among five measurement categories, the noticeable difference was distinguished from two factors; the change of upper lip curvature and contact relation between Mx. incisor and lower lip. Conclusion: The Korean young men's smile has been considerably improved for twenty years. And it is found that the change of upper lip curvature plays an important role, that is, the smile formed with an ascended labial commissure has been increased significantly.