• Title/Summary/Keyword: OCT

Search Result 1,422, Processing Time 0.03 seconds

Assessment of retinal degeneration with optical coherence tomography in a dog (Ocular coherence tomography를 이용한 개의 망막변성증 평가)

  • Ji, Dongbeom;Yoo, Sukjong;Seo, Kangmoon;Jeong, Manbok
    • Korean Journal of Veterinary Research
    • /
    • v.53 no.2
    • /
    • pp.137-141
    • /
    • 2013
  • To report retinal image of in a 6-year-old male castrated poodle dog with a 2-month history of nyctalopia using optical coherence tomography (OCT). Ocular reflexes were present in both eyes and slit lamp examination showed anterior subscapular cataract in the right eye. There were fundus abnormalities in both eyes similar to retinal degeneration. Scotopic electroretinograms (ERGs) revealed significantly subabnormal amplitudes and prolonged implicit time, whereas photopic ERGs were better maintained, although far from normal. OCT of affected dogs revealed generalized retinal thinning much more than a normal age-matched dog. Therefore, OCT scanning is considered to be a useful method for retinal evaluation in dogs with retinal degeneration.

Ultrafast Optical Delay Line by Use of a Phase Modulator for OCT Application (OCT용 초고속 위상 변조 광지연단 설계)

  • Hwang, Dae-seok;Oh, Se-Yong;Lee, Ho-Guen;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.438-440
    • /
    • 2005
  • 광위상변조기를 이용하여 OCT용 초고속 광지연단을 설계하고 수치해석을 수행하였다. 수치해석은 electro-optic 위상 변조기에 1310nm, 10ps의 펄스폭을 갖는 레이저 광원을 적용하여 수행하였다. 수치해석결과로 500MHz의 변조 주파수일때 19ps의 시간 지연을 얻었으며, 이는 기존의 기계적 검출방식(수십kHz)의 OCT장치에 비해 1000배이상 빠른 검출이 가능할 것으로 예상된다.

  • PDF

OCT Signal Analysis and Optimization in Dental Medium using Monte-Carlo Simulation (몬테카를로 시뮬레이션을 이용한 치아 조직내 OCT 신호 해석 및 최적화)

  • 황대석;이승용;김신자;류광렬;이호근;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.321-323
    • /
    • 2004
  • We developed the monte-carlo simulation code for analysis of the On signal in dental medium. In calculation, we obtain the two different propagation signals as a function of the probing depth. Signal 2 begins to exceed the signal 1 at a very small probing depth(=60${\mu}{\textrm}{m}$). For reduce the signal, detection area is limited to radius and detection angle. As numerical result, probing depth becomes appoximately 500${\mu}{\textrm}{m}$.

  • PDF

Common-path Optical Coherence Tomography for Biomedical Imaging and Sensing

  • Kang, Jin-U.;Han, Jae-Ho;Liu, Xuan;Zhang, Kang
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.1-13
    • /
    • 2010
  • This paper describes a development of a fiber optic common-path optical coherence tomography (OCT) based imaging and guided system that possess ability to reliably identify optically transparent targets that are on the micron scale; ability to maintain a precise and safe position from the target; ability to provide spectroscopic imaging; ability to imaging biological target in 3-D. The system is based on a high resolution fiber optic Common-Path OCT (CP-OCT) that can be integrated into various mini-probes and tools. The system is capable of obtaining >70K A-scan per second with a resolution better than $3\;{\mu}m$. We have demonstrated that the system is capable of one-dimensional real-time depth tracking, tool motion limiting and motion compensation, oxygen-saturation level imaging, and high resolution 3-D images for various biomedical applications.

Analysis of the Scattering Coefficients of Microspheres Using Spectroscopic Optical Coherence Tomography

  • Song, Woosub;Lee, Seung Seok;Lee, Byeong-il;Choi, Eun Seo
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.278-288
    • /
    • 2021
  • We propose a characterization method for the scattering property of microspheres using spectroscopic optical coherence tomography (OCT). To prove the effectiveness of the proposed method, we prepare solutions of different concentrations using microspheres ranging from 28 to 2300 nm in diameter. Time-frequency analysis is performed on the measured interference spectrum of each solution, and the resulting spectroscopic information is converted into histograms for centroid wavelengths. The histograms present a very sensitive response to changes in the concentration and size of microspheres. We classify them into three categories according to their characteristics. When the histogram of each category is replaced with the corresponding calculated value of the scattering coefficient, each category is mapped to a different scattering-coefficient region. It is expected that the proposed method could be used to investigate the optical characteristics of a biological sample from OCT images, which would be helpful for optical diagnostic and therapeutic applications.

A case of Candida albicans-induced fungal keratitis in a Chihuahua dog - with a focus on optical coherence tomographic features

  • Heejong Cho;Manbok Jeong;Sukjong Yoo
    • Journal of Veterinary Science
    • /
    • v.24 no.2
    • /
    • pp.30.1-30.6
    • /
    • 2023
  • A 4-year-old Chihuahua dog was referred for bilateral corneal ulcers. Slightly raised white fluorescein-positive plaque-like corneal lesions in both eyes appeared as intense hyperreflective areas with posterior shadowing on optical coherence tomography (OCT). Based on corneal cytology and culture, Candida albicans-induced fungal keratitis was diagnosed. Despite treatment, on OCT, endothelial plaques, increased stromal infiltration thickness, vertical shapes of the ulcer edge, and necrotic stromal space were judged to be aggravation of the disease, and surgery was performed. Conjunctival grafting surgery with topical 1% voriconazole effectively resolved fungal keratitis. OCT can provide detailed and objective information related to the disease prognosis.

Early-Stage Diagnosis of Cervix using the Polarization Sensitive Optical Coherence Tomography(A Preliminary Study) (편광 민감 광결맞음 단층 촬영 장치를 이용한 자궁경부의 조기 진단(A Preliminary Study))

  • Kang, Jin-Ho;Lee, Sang-Won;Yoo, Ji-Yeong;Kang, Moon-Sik;Kim, Beop-Min;Yoon, Bo-Sung;Kim, Young-Tae;Cho, Nam-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.367-372
    • /
    • 2007
  • Cervical dysplasia induces morphologic changes in the cervical epithelium which involve changes in the nuclear/cytoplasmic (N/C) ratio. Since the nucleus is one of the significant scattering sources, the N/C ratio change reflects the degree of circular polarization (DOCP) with the depth of signals. Therefore, we used the polarization-sensitive OCT (PS-OCT) technique to measure the polarization changes caused by scattering. Cervical tissues were obtained from a high-grade squamous intraepithelial lesion (H-SIL) of one woman and from low normal women. We obtained the mean of the DOCP as a function of depth in the cervix and quantified the change ratio of the DOCP using slopes that were determined by linear fits in the epithelium layer. We found that DOCP of H-SIL decayed faster than that of normal tissue because of the higher scattering in H-SIL as expected. This result indicates that the PS-OCT system might be useful in measurements of change ratio of DOCP with depth for screening of cervical dysplasia.

Three-dimensional Imaging with an Endoscopic Optical Coherence Tomography System for Detection of Airway Stenosis (기도협착 측정을 위한 내시경 광 결맞음 단층촬영법을 이용한 3차원 이미징)

  • Kwon, Daa young;Oak, Chulho;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.243-248
    • /
    • 2019
  • The respiratory tract is an essential part of the respiratory system involved in the process of respiration. However, if stenosis occurs, it interferes with breathing and can even lead to death. Asthma is a typical example of a reversible cause of airway narrowing, and the number of patients suffering from acute exacerbation is steadily increasing. Therefore, it is important to detect airway narrowing early and prevent the patient's condition from worsening. Optical coherence tomography (OCT), which has high resolution, is suitable for observing the microstructure of tissues. In this study we developed an endoscopic OCT system. We combined a 1300-nm OCT system with a servo motor, which can rotate at a high speed. A catheter was pulled back using a linear stage while imaging with 360° rotation by the motor. The motor was selected considering various requirements, such as torque, rotational speed, and gear ratio of pulleys. An ex vivo rabbit tracheal model was used as a sample, and the sample and catheter were immobilized by acrylic structures. The OCT images provided information about the structures of the mucosa and submucosa. The difference between normal and stenosed parts in the trachea was confirmed by OCT. Furthermore, through a three-dimensional (3-D) reconstruction process, it was possible to identify and diagnose the stenosis in the 3-D image of the airway, as well as the cross-sectional image. This study would be useful not only for diagnosing airway stenosis, but also for realizing 3-D imaging.

Colonizing Aphid Species and Their Seasonal Fluctuations on Some Fruit Trees in Suweon (주요(主要) 과수(果樹)에서 발생(發生)하는 진딧물의 종류(種類)와 발생소장(發生消長)에 관(關)한 연구(硏究))

  • Kim, Seok-Whan;Lee, S.W.;Kim, I.S.;Lee, M.H.
    • Korean journal of applied entomology
    • /
    • v.25 no.4 s.69
    • /
    • pp.209-213
    • /
    • 1986
  • Dominant aphid species and seasonal fluctuations of the colonizing aphids on apple tree, peach tree, and pear tree were examined without insecticide treatment during $1982{\sim}1984$ in Suweon. The dominant species among the colonizing aphids in each fruit tree were Myzus malisuctus in April-June and Aphis citricola in Aug.-Oct. on apple tree; Myzus persicae in early springtime and Hyalopterus pruni in May-Oct. on peach tree; Sappaphis piri in April-June, Oct. and Aphis citricola in July-Sept. on pear tree. M. malisuctus and A. citricola on apple tree showed 3 peaks a year; the former was early June, late Aug. and early Oct., the latter early June, middle Aug. and late Sept. M. persicae on peach tree showed peak on late May to early June, and H. pruni on middle June and middle Oct. S. piri and A. citricola on pear tree showed 2 peaks a year; the former was late May and late Oct., the latter early June and early Sept.

  • PDF

Quantification protocol for spectral-domain OCT using FBGs (광섬유 격자를 이용한 주파수 영역 OCT의 특성 정량화)

  • Eom, Tae-Jung;Kim, Chang-Seok;An, Ye-Chan
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.169-170
    • /
    • 2009
  • We present a quantification protocol to get the alignment factors of a custom-made spectrometer and the nonlinear fitting function between the measured CCD pixel domain and the wavelength domain to apply the spectral-domain optical coherence tomography using fiber Bragg gratings. We have used 4 different center wavelength gratings with a narrow spectral bandwidth (<0.05 nm) and the same reflectivity (>92 %) to calibrate and align the custom-made spectrometer.

  • PDF